914 resultados para Monitoring System


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the context of increasing beam energy and luminosity of the LHC accelerator at CERN, it will be important to accurately measure the Machine Induced Background. A new monitoring system will be installed in the CMS cavern for measuring the beam background at high radius. This detector, called the Beam Halo Monitor, will provide an online, bunch-by-bunch measurement of background induced by beam halo interactions, separately for each beam. The detector is composed of synthetic quartz Cherenkov radiators, coupled to fast UV sensitive photomultiplier tubes. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. The readout electronics of this detector will make use of many components developed for the upgrade of the CMS Hadron Calorimeter electronics, with a dedicated firmware and readout adapted to the beam monitoring requirements. The PMT signal will be digitized by a charge integrating ASIC, providing both the signal rise time and the charge integrated over one bunch crossing. The backend electronics will record bunch-by-bunch histograms, which will be published to CMS and the LHC using the newly designed CMS beam instrumentation specific DAQ. A calibration and monitoring system has been designed to generate triggered pulses of UV light to monitor the efficiency of the system. The experimental results validating the design of the detector, the calibration system and the electronics will be presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Um einen positiven Einfluss auf den Krankheitsverlauf bei Patienten mit Rheumatoider Arthritis zu nehmen, ist die Compliance mit dem Basistherapeutikum Methotrexat unerlässlich. Therapietreue mit Methotrexat kann die Krankheitsprogression verhindern und irreversiblen Knochenerosionen vorbeugen. Methotrexat wird sowohl in subkutaner als auch in peroraler Applikationsform verordnet. Im Rahmen der vorliegenden Arbeit wurde die Compliance mit der Anwendung von Methotrexat Fertigspritzen und Tabletten mit einer elektronischen Messmethode (MEMS™) bestimmt. Hauptziel der Studie war die Bestimmung der Taking Compliance mit Methotrexat. Untersucht wurde hinsichtlich eines Unterschieds zwischen der Applikationsform und der Erkrankungsdauer. Daneben wurde die Dosing Compliance mit peroralem Methotrexat erfasst, sowie Einschätzungen der Patienten bezüglich der Compliance, Funktionskapazität, Lebensqualität und Zufriedenheit erhoben. Die Compliancestudie erfolgte in Kooperation mit dem Netzwerk ADAPTHERA. 74 Studienpatienten wurden 3 Gruppen zugeteilt: Gruppe 1 Methotrexat p.o.; Gruppe 2 Methotrexat s.c. und Erkrankungsdauer <24 Monate; Gruppe 3 Methotrexat s.c. und Erkrankungsdauer >24 Monate. Die Beobachtungsdauer betrug bei peroraler Applikationsform 9 Monate und bei subkutaner 6 Monate. Im Median wurde eine Taking und Dosing Compliance von 100% gemessen. Anhand der subjektiven Einschätzung der Patienten zur Funktionskapazität konnten geringe Einschränkungen für die Patienten im Alltag verzeichnet werden. 25% des Studienkollektivs litt unter einem reduzierten Wohlbefinden. Die Studie konnte zeigen, dass Patienten von einer frühzeitigen Therapie und einer hohen Compliancerate profitieren.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’obiettivo della seguente tesi è quello di illustrare le condizioni in cui avviene il trasferimento di conoscenza da consulente a cliente, e come questo sia il fattore abilitante per l’esistenza e l’utilizzo di tale figura professionale da parte delle organizzazioni. Questa tesi nasce dall’esperienza vissuta durante la partecipazione alla XXIV edizione di Junior Consulting, un programma organizzato da CONSEL - ELIS presso Roma, che ha permesso al sottoscritto di prendere parte al progetto di consulenza “Engineering & Construction - Performance Monitoring System” commissionato da Enel Green Power. L’esigenza manifestata dall’azienda era quella di riuscire ad avere una visione chiara e definita della qualità delle attività svolte dalla funzione Engineering & Construction (E&C) e quindi l’obiettivo del progetto si è concretizzato nella definizione di un set di KPI idoneo a rappresentare una misura delle performance della suddetta funzione. Avendo testato, seppure per pochi mesi, l’attività consulenziale, il candidato ha compiuto uno studio teorico che andasse ad analizzare in dettaglio l’attività del consulente, la sua importanza nel mondo economico, il contesto in cui opera e i principali dibattiti accademici di cui è protagonista negli ultimi anni. Nell’elaborato viene analizzato il caso pratico sulla base degli studi della letteratura, con lo scopo di formulare un modello che descriva l’approccio che il consulente dovrebbe avere, durante lo svolgimento delle sue attività, per la realizzazione del trasferimento di conoscenza. Nel primo capitolo è riportato uno studio relativo all’importanza e agli effetti che le società di consulenza hanno avuto nell’ultimo secolo ed in particolare negli ultimi 30 anni. Nel secondo capitolo è descritto il core asset delle società di consulenza, ovvero la conoscenza, e come questa è strutturata e gestita. Nel terzo capitolo sono analizzate le principali teorie sviluppate sulla figura del consulente, sia l’evoluzione storica che le principali posizioni ancora oggi oggetto di dibattito. Nel quarto capitolo l’attenzione è focalizzata sul trasferimento di conoscenza da consulente a cliente e sulle condizioni in cui questo può avvenire. Nel quinto capitolo è presentato il progetto sopracitato, i cui risultati sono riportati negli allegati 1 e 2. Infine, nel sesto capitolo, è presentato un modello di approccio del consulente ottenuto dall’analisi critica del caso pratico sulla base delle evidenze emerse dallo studio della letteratura.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main purpose of ultrarelativistic heavy-ion collisions is the investigation of the QGP. The ALICE experiment situated at the CERN has been specifically designed to study heavy-ion collisions for centre-of-mass energies up to 5.5 per nucleon pair. Extended particle identification capability is one of the main characteristics of the ALICE experiment. In the intermediate momentum region (up to 2.5 GeV/c for pi/K and 4 GeV/c for K/p), charged particles are identified in the ALICE experiment by the Time of Flight (TOF) detector. The ALICE-TOF system is a large-area detector based on the use of Multi-gap Resistive Plate Chamber (MRPC) built with high efficiency, fast response and intrinsic time resolution better than 40 ps. This thesis work, developed with the ALICE-TOF Bologna group, is part of the efforts carried out to adapt the read-out of the detector to the new requirements after the LHC Long Shutdown 2. Tests on the feasibility of a new read-out scheme for the TOF detector have been performed. In fact, the achievement of a continuous read-out also for the TOF detector would not be affordable if one considers the replacement of the TRM cards both for hardware and budget reasons. Actually, the read-out of the TOF is limited at 250 kHz i.e. it would be able to collect up to just a fourth of the maximum collision rate potentially achievable for pp interactions. In this Master’s degree thesis work, I discuss a different read-out system for the ALICE-TOF detector that allows to register all the hits at the interaction rate of 1 MHz foreseen for pp interactions after the 2020, by using the electronics currently available. Such solution would allow the ALICE-TOF detector to collect all the hits generated by pp collisions at 1 MHz interaction rate, which corresponds to an amount four times larger than that initially expected at such frequencies with the triggered read-out system operated at 250 kHz for LHC Run 3. The obtained results confirm that the proposed read-out scheme is a viable option for the ALICE TOF detector. The results also highlighted that it will be advantageous if the ALICE-TOF group also implement an online monitoring system of noisy channels to allow their deactivation in real time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper two models for the simulation of glucose-insulin metabolism of children with Type 1 diabetes are presented. The models are based on the combined use of Compartmental Models (CMs) and artificial Neural Networks (NNs). Data from children with Type 1 diabetes, stored in a database, have been used as input to the models. The data are taken from four children with Type 1 diabetes and contain information about glucose levels taken from continuous glucose monitoring system, insulin intake and food intake, along with corresponding time. The influences of taken insulin on plasma insulin concentration, as well as the effect of food intake on glucose input into the blood from the gut, are estimated from the CMs. The outputs of CMs, along with previous glucose measurements, are fed to a NN, which provides short-term prediction of glucose values. For comparative reasons two different NN architectures have been tested: a Feed-Forward NN (FFNN) trained with the back-propagation algorithm with adaptive learning rate and momentum, and a Recurrent NN (RNN), trained with the Real Time Recurrent Learning (RTRL) algorithm. The results indicate that the best prediction performance can be achieved by the use of RNN.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The recreational use of 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) among adolescents and young adults has become increasingly prevalent in recent years. While evidence suggests that the long-term consequences of MDMA use include neurodegeneration to serotonergic and, possibly, dopaminergic pathways, little is known about susceptibility, such as behavioral sensitization, to MDMA. METHODS: The objectives of this study were to examine the dose-response characteristics of acute and chronic MDMA administration in rats and to determine whether MDMA elicits behavioral sensitization and whether it cross-sensitizes with amphetamine and methylphenidate. Adult male Sprague-Dawley rats were randomly divided into three MDMA dosage groups (2.5 mg/kg, 5.0 mg/kg, and 10.0 mg/kg) and a saline control group (N = 9/group). All three MDMA groups were treated for six consecutive days, followed by a 5-day washout, and subsequently re-challenged with their respective doses of MDMA (day 13). Rats were then given an additional 25-day washout period, and re-challenged (day 38) with similar MDMA doses as before followed by either 0.6 mg/kg amphetamine or 2.5 mg/kg methylphenidate on the next day (day 39). Open-field locomotor activity was recorded using a computerized automated activity monitoring system. RESULTS: Acute injection of 2.5 mg/kg MDMA showed no significant difference in locomotor activity from rats given saline (control group), while animals receiving acute 5.0 mg/kg or 10.0 mg/kg MDMA showed significant increases in locomotor activity. Rats treated chronically with 5.0 mg/kg and 10.0 mg/kg MDMA doses exhibited an augmented response, i.e., behavioral sensitization, on experimental day 13 in at least one locomotor index. On experimental day 38, all three MDMA groups demonstrated sensitization to MDMA in at least one locomotor index. Amphetamine and methylphenidate administration to MDMA-sensitized animals did not elicit any significant change in locomotor activity compared to control animals. CONCLUSION: MDMA sensitized to its own locomotor activating effects but did not elicit any cross-sensitization with amphetamine or methylphenidate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Methylphenidate (MPD) is a psychostimulant commonly prescribed for attention deficit/hyperactivity disorder. The mode of action of the brain circuitry responsible for initiating the animals' behavior in response to psychostimulants is not well understood. There is some evidence that psychostimulants activate the ventral tegmental area (VTA), nucleus accumbens (NAc), and prefrontal cortex (PFC). METHODS: The present study was designed to investigate the acute dose-response of MPD (0.6, 2.5, and 10.0 mg/kg) on locomotor behavior and sensory evoked potentials recorded from the VTA, NAc, and PFC in freely behaving rats previously implanted with permanent electrodes. For locomotor behavior, adult male Wistar-Kyoto (WKY; n = 39) rats were given saline on experimental day 1 and either saline or an acute injection of MPD (0.6, 2.5, or 10.0 mg/kg, i.p.) on experimental day 2. Locomotor activity was recorded for 2-h post injection on both days using an automated, computerized activity monitoring system. Electrophysiological recordings were also performed in the adult male WKY rats (n = 10). Five to seven days after the rats had recovered from the implantation of electrodes, each rat was placed in a sound-insulated, electrophysiological test chamber where its sensory evoked field potentials were recorded before and after saline and 0.6, 2.5, and 10.0 mg/kg MPD injection. Time interval between injections was 90 min. RESULTS: Results showed an increase in locomotion with dose-response characteristics, while a dose-response decrease in amplitude of the components of sensory evoked field responses of the VTA, NAc, and PFC neurons. For example, the P3 component of the sensory evoked field response of the VTA decreased by 19.8% +/- 7.4% from baseline after treatment of 0.6 mg/kg MPD, 37.8% +/- 5.9% after 2.5 mg/kg MPD, and 56.5% +/- 3.9% after 10 mg/kg MPD. Greater attenuation from baseline was observed in the NAc and PFC. Differences in the intensity of MPD-induced attenuation were also found among these brain areas. CONCLUSION: These results suggest that an acute treatment of MPD produces electrophysiologically detectable alterations at the neuronal level, as well as observable, behavioral responses. The present study is the first to investigate the acute dose-response effects of MPD on behavior in terms of locomotor activity and in the brain involving the sensory inputs of VTA, NAc, and PFC neurons in intact, non-anesthetized, freely behaving rats previously implanted with permanent electrodes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Methylphenidate (MPD), commonly known as Ritalin, is the most frequently prescribed drug to treat children and adults with attention deficit hyperactivity disorder (ADHD). Adolescence is a period of development involving numerous neuroplasticities throughout the central nervous system (CNS). Exposure to a psychostimulant such as MPD during this crucial period of neurodevelopment may cause transient or permanent changes in the CNS. Genetic variability may also influence these differences. Thus, the objective of the present study was to determine whether acute and chronic administration of MPD (0.6, 2.5, or 10.0mg/kg, i.p.) elicit effects among adolescent WKY, SHR, and SD rats and to compare whether there were strain differences. An automated, computerized, open-field activity monitoring system was used to study the dose-response characteristics of acute and repeated MPD administration throughout the 11-day experimental protocol. Results showed that all three adolescent rat groups exhibited dose-response characteristics following acute and chronic MPD administration, as well as strain differences. These strain differences depended on the MPD dose and locomotor index. Chronic treatment of MPD in these animals did not elicit behavioral sensitization, a phenomenon described in adult rats that is characterized by the progressive augmentation of the locomotor response to repeated administration of the drug. These results suggest that the animal's age at time of drug treatment and strain/genetic variability play a crucial role in the acute and chronic effect of MPD and in the development of behavioral sensitization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Zur Versachlichung der Diskussion über die TK-Studie zum Effekt eines Qualitätsmonitorings in der ambulanten Psychotherapie hat der wissenschaftliche Beirat die Ergebnisse aus seiner Sichtweise dargestellt. Zur Hauptfragestellung wird der Abschlussbericht zitiert, der bestätigt, dass es sich um eine konfirmatorische Untersuchung handelte. Im Kern sollte sie die Hypothesen zur Überlegenheit des TK-Modells gegenüber dem Verfahren der Gutachterverfahren überprüfen. Beim TK-Modell handelt es sich um eine „Komplexintervention“, die aus mehreren Bausteinen bestand. Die Studienergebnisse lassen somit nur die Aussage zu, dass diese Komplexintervention in ihrer Kombination keine Überlegenheit gezeigt hat. Ob einzelne Bausteine Wirksamkeit hatten, bedarf weiterer Forschung. Schließlich werden das Repräsentativitäts- und das Selektivitätsproblem der Studie bzw. der verwertbaren Stichproben erläutert und mit Verweis auf die Literatur wird deren Relevanz dargelegt.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stratospheric ozone is of major interest as it absorbs most harmful UV radiation from the sun, allowing life on Earth. Ground-based microwave remote sensing is the only method that allows for the measurement of ozone profiles up to the mesopause, over 24 hours and under different weather conditions with high time resolution. In this paper a novel ground-based microwave radiometer is presented. It is called GROMOS-C (GRound based Ozone MOnitoring System for Campaigns), and it has been designed to measure the vertical profile of ozone distribution in the middle atmosphere by observing ozone emission spectra at a frequency of 110.836 GHz. The instrument is designed in a compact way which makes it transportable and suitable for outdoor use in campaigns, an advantageous feature that is lacking in present day ozone radiometers. It is operated through remote control. GROMOS-C is a total power radiometer which uses a pre-amplified heterodyne receiver, and a digital fast Fourier transform spectrometer for the spectral analysis. Among its main new features, the incorporation of different calibration loads stands out; this includes a noise diode and a new type of blackbody target specifically designed for this instrument, based on Peltier elements. The calibration scheme does not depend on the use of liquid nitrogen; therefore GROMOS-C can be operated at remote places with no maintenance requirements. In addition, the instrument can be switched in frequency to observe the CO line at 115 GHz. A description of the main characteristics of GROMOS-C is included in this paper, as well as the results of a first campaign at the High Altitude Research Station at Jungfraujoch (HFSJ), Switzerland. The validation is performed by comparison of the retrieved profiles against equivalent profiles from MLS (Microwave Limb Sounding) satellite data, ECMWF (European Centre for Medium-Range Weather Forecast) model data, as well as our nearby NDACC (Network for the Detection of Atmospheric Composition Change) ozone radiometer measuring at Bern.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chronic administration of psychomotor stimulants has been reported to produce behavioral sensitization to its effects on motor activity. This adaptation may be related to the pathophysiology of recurrent psychiatric disorders. Since disturbances in circadian rhythms are also found in many of these disorders, the relationship between sensitization and chronobiological factors became of interest. Therefore, a computerized monitoring system investigated the following: whether repeated exposure to methylphenidate (MPD) and amphetamine (AMP) could produce sensitization to its locomotor effects in the rat; whether sensitization to MPD and AMP was dependent on the circadian time of drug administration; whether the baseline levels of locomotor activity would be effected by repeated exposure to MPD and AMP; whether the expression of a sensitized response could be affected by the photoperiod; and whether MK-801, a non-competitive NMDA antagonist, could disrupt the development of sensitization to MPD. Dawley rats were housed in test cages and motor activity was recorded continuously for 16 days. The first 2 days served as baseline for each rat, and on day 3 each rat received a saline injection. The locomotor response to 0.6, 2.5, or 10 mg/kg of MPD was tested on day 4, followed by five days of single injections of 2.5 mg/kg MPD (days 5–9). After five days without injection (days 10–14) rats were re-challenged (day 15) with the same doses they received on day 4. There were three separate dose groups ran at four different times of administration, 08:00, 14:00, 20:00, or 02:00 (i.e. 12 groups). The same protocol was conducted with AMP with the doses of 0.3, 0.6, and 1.2 mg/kg given on day 4 and 15, and 0.6 mg/kg AMP as the repeated dose on days 5 to 9. In the second set of experiments only sensitization to MPD was investigated. The expression of the sensitized response was dose-dependent and mainly observed with challenge of the lower dose groups. The development of sensitization to MPD and ANT was differentially time-dependent. For MPD, the most robust sensitization occurred during the light phase, with no sensitization during the middle of the dark phase. (Abstract shortened by UMI.) ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Very few studies have described MUP-1 concentrations and measured prevalence of Laboratory Animal Allergy (LAA) at such a diverse institution as the private medical school (MS) that is the focus of this study. Air sampling was performed in three dissimilar animal research facilities at MS and quantitated using a commercially available ELISA. Descriptive data was obtained from an anonymous laboratory animal allergy survey given to both animal facility employees and the researchers who utilize these facilities alike. Logistic regression analysis was then implemented to investigate specific factors that may be predictive of developing LAA as well as factors influencing the reporting of LAA symptoms to the occupational health program. Concentrations of MUP-1 detected ranged from below detectable levels (BDL) to a peak of 22.64 ng/m3 . Overall, 68 employees with symptoms claimed they improved while away from work and only 25 employees reported their symptoms to occupational health. Being Vietnamese, a smoker, not wearing a mask, and working in any facility longer than one year were all significant predictors of having LAA symptoms. This study suggests a LAA monitoring system that relies on self-reporting can be inadequate in estimating LAA problems. In addition, efforts need to be made to target training and educational materials for non-native English speaking employees to overcome language and cultural barriers and address their specific needs. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction. Despite the ban of lead-containing gasoline and paint, childhood lead poisoning remains a public health issue. Furthermore, a Medicaid-eligible child is 8 times more likely to have an elevated blood lead level (EBLL) than a non-Medicaid child, which is the primary reason for the early detection lead screening mandate for ages 12 and 24 months among the Medicaid population. Based on field observations, there was evidence that suggested a screening compliance issue. Objective. The purpose of this study was to analyze blood lead screening compliance in previously lead poisoned Medicaid children and test for an association between timely lead screening and timely childhood immunizations. The mean months between follow-up tests were also examined for a significant difference between the non-compliant and compliant lead screened children. Methods. Access to the surveillance data of all childhood lead poisoned cases in Bexar County was granted by the San Antonio Metropolitan Health District. A database was constructed and analyzed using descriptive statistics, logistic regression methods and non-parametric tests. Lead screening at 12 months of age was analyzed separately from lead screening at 24 months. The small portion of the population who were also related were included in one analysis and removed from a second analysis to check for significance. Gender, ethnicity, age of home, and having a sibling with an EBLL were ruled out as confounders for the association tests but ethnicity and age of home were adjusted in the nonparametric tests. Results. There was a strong significant association between lead screening compliance at 12 months and childhood immunization compliance, with or without including related children (p<0.00). However, there was no significant association between the two variables at the age of 24 months. Furthermore, there was no significant difference between the median of the mean months of follow-up blood tests among the non-compliant and compliant lead screened population for at the 12 month screening group but there was a significant difference at the 24 month screening group (p<0.01). Discussion. Descriptive statistics showed that 61% and 56% of the previously lead poisoned Medicaid population did not receive their 12 and 24 month mandated lead screening on time, respectively. This suggests that their elevated blood lead level may have been diagnosed earlier in their childhood. Furthermore, a child who is compliant with their lead screening at 12 months of age is 2.36 times more likely to also receive their childhood immunizations on time compared to a child who was not compliant with their 12 month screening. Even though there was no statistical significant association found for the 24 month group, the public health significance of a screening compliance issue is no less important. The Texas Medicaid program needs to enforce lead screening compliance because it is evident that there has been no monitoring system in place. Further recommendations include a need for an increased focus on parental education and the importance of taking their children for wellness exams on time.^