876 resultados para Load voltage maximization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direction-selective retinal ganglion cells show an increased activity evoked by light stimuli moving in the preferred direction. This selectivity is governed by direction-selective inhibition from starburst amacrine cells occurring during stimulus movement in the opposite or null direction. To understand the intrinsic membrane properties of starburst cells responsible for direction-selective GABA release, we performed whole-cell recordings from starburst cells in mouse retina. Voltage-clamp recordings revealed prominent voltage-dependent K+ currents. The currents were mostly blocked by 1 mm TEA, activated rapidly at voltages more positive than -20 mV, and deactivated quickly, properties reminiscent of the currents carried by the Kv3 subfamily of K+ channels. Immunoblots confirmed the presence of Kv3.1 and Kv3.2 proteins in retina and immunohistochemistry revealed their expression in starburst cell somata and dendrites. The Kv3-like current in starburst cells was absent in Kv3.1-Kv3.2 knock-out mice. Current-clamp recordings showed that the fast activation of the Kv3 channels provides a voltage-dependent shunt that limits depolarization of the soma to potentials more positive than -20 mV. This provides a mechanism likely to contribute to the electrical isolation of individual starburst cell dendrites, a property thought essential for direction selectivity. This function of Kv3 channels differs from that in other neurons where they facilitate high-frequency repetitive firing. Moreover, we found a gradient in the intensity of Kv3.1b immunolabeling favoring proximal regions of starburst cells. We hypothesize that this Kv3 channel gradient contributes to the preference for centrifugal signal flow in dendrites underlying direction-selective GABA release from starburst amacrine cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the construction of the Saylorville Dam and Reservoir on the Des Moines River, six highway bridges crossing the river were scheduled for removal. One of these, an old pinconnected high-truss single-lane bridge, was selected for a testing program which included ultimate load tests. The purpose of the ultimate load tests, which are summarized in this report, was to relate design and rating procedures presently used in bridge design to the field behavior of this type of truss bridge. The ultimate load tests consisted of ultimate load testing of one span of the bridge, of two I-shaped floorbeams, and of two panels of the timber deck. The theoretical capacity of each of these components is compared with the results from the field tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral neuropathic pain is a disabling condition resulting from nerve injury. It is characterized by the dysregulation of voltage-gated sodium channels (Navs) expressed in dorsal root ganglion (DRG) sensory neurons. The mechanisms underlying the altered expression of Navs remain unknown. This study investigated the role of the E3 ubiquitin ligase NEDD4-2, which is known to ubiquitylate Navs, in the pathogenesis of neuropathic pain in mice. The spared nerve injury (SNI) model of traumatic nerve injury-induced neuropathic pain was used, and an Nav1.7-specific inhibitor, ProTxII, allowed the isolation of Nav1.7-mediated currents. SNI decreased NEDD4-2 expression in DRG cells and increased the amplitude of Nav1.7 and Nav1.8 currents. The redistribution of Nav1.7 channels toward peripheral axons was also observed. Similar changes were observed in the nociceptive DRG neurons of Nedd4L knockout mice (SNS-Nedd4L-/-). SNS-Nedd4L-/- mice exhibited thermal hypersensitivity and an enhanced second pain phase after formalin injection. Restoration of NEDD4-2 expression in DRG neurons using recombinant adenoassociated virus (rAAV2/6) not only reduced Nav1.7 and Nav1.8 current amplitudes, but also alleviated SNI-induced mechanical allodynia. These findings demonstrate that NEDD4-2 is a potent posttranslational regulator of Navs and that downregulation of NEDD4-2 leads to the hyperexcitability of DRG neurons and contributes to the genesis of pathological pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increase in VLDL TAG concentration after ingestion of a high-fructose diet is more pronounced in men than in pre-menopausal women. We hypothesised that this may be due to a lower fructose-induced stimulation of de novo lipogenesis (DNL) in pre-menopausal women. To evaluate this hypothesis, nine healthy male and nine healthy female subjects were studied after ingestion of oral loads of fructose enriched with 13C6 fructose. Incorporation of 13C into breath CO2, plasma glucose and plasma VLDL palmitate was monitored to evaluate total fructose oxidation, gluconeogenesis and hepatic DNL, respectively. Substrate oxidation was assessed by indirect calorimetry. After 13C fructose ingestion, 44.0 (sd 3.2)% of labelled carbons were recovered in plasma glucose in males v. 41.9 (sd 2.3)% in females (NS), and 42.9 (sd 3.7)% of labelled carbons were recovered in breath CO2 in males v. 43.0 (sd 4.5)% in females (NS), indicating similar gluconeogenesis from fructose and total fructose oxidation in males and females. The area under the curve for 13C VLDL palmitate tracer-to-tracee ratio was four times lower in females (P < 0.05), indicating a lower DNL. Furthermore, lipid oxidation was significantly suppressed in males (by 16.4 (sd 5.2), P < 0.05), but it was not suppressed in females ( -1.3 (sd 4.7)%). These results support the hypothesis that females may be protected against fructose-induced hypertriglyceridaemia because of a lower stimulation of DNL and a lower suppression of lipid oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the construction of the Saylorville Dam and Reservoir on the Des Moines River, six highway bridges crossing the river were scheduled for removal. Two of these were incorporated into a comprehensive test program to study the behavior of old pin-connected high-truss single-lane bridges. The test program consisted of ultimate load tests, service load tests and a supplementary test program. The results reported in this report cover the service load tests on the two bridges as well as the supplementary tests, both static and fatigue, of eyebar members removed from the two bridges. The field test results of the service loading are compared with theoretical results of the truss analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This main report provides a general discussion of the load testing, structural evaluation, and load rating procedures. Specific details for each bridge are provided in individual report sections. Additional supporting information on load testing, analyses, and load rating are also provided in the attached appendices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Variables influencing serum hepatitis C virus (HCV) RNA levels and genotype distribution in individuals with human immunodeficiency virus (HIV) infection are not well known, nor are factors determining spontaneous clearance after exposure to HCV in this population. METHODS: All HCV antibody (Ab)-positive patients with HIV infection in the EuroSIDA cohort who had stored samples were tested for serum HCV RNA, and HCV genotyping was done for subjects with viremia. Logistic regression was used to identify variables associated with spontaneous HCV clearance and HCV genotype 1. RESULTS: Of 1940 HCV Ab-positive patients, 1496 (77%) were serum HCV RNA positive. Injection drug users (IDUs) were less likely to have spontaneously cleared HCV than were homosexual men (20% vs. 39%; adjusted odds ratio [aOR], 0.36 [95% confidence interval {CI}, 0.24-0.53]), whereas patients positive for hepatitis B surface antigen (HBsAg) were more likely to have spontaneously cleared HCV than were those negative for HBsAg (43% vs. 21%; aOR, 2.91 [95% CI, 1.94-4.38]). Of patients with HCV viremia, 786 (53%) carried HCV genotype 1, and 53 (4%), 440 (29%), and 217 (15%) carried HCV genotype 2, 3, and 4, respectively. A greater HCV RNA level was associated with a greater chance of being infected with HCV genotype 1 (aOR, 1.60 per 1 log higher [95% CI, 1.36-1.88]). CONCLUSIONS: More than three-quarters of the HIV- and HCV Ab-positive patients in EuroSIDA showed active HCV replication. Viremia was more frequent in IDUs and, conversely, was less common in HBsAg-positive patients. Of the patients with HCV viremia analyzed, 53% were found to carry HCV genotype 1, and this genotype was associated with greater serum HCV RNA levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The supply voltage decrease and powerconsumption increase of modern ICs made the requirements for low voltage fluctuation caused by packaging and on-chip parasitic impedances more difficult to achieve. Most of the research works on the area assume that all the nodes of the chip are fed at thesame voltage, in such a way that the main cause of disturbance or fluctuation is the parasitic impedance of packaging. In the paper an approach to analyze the effect of high and fast current demands on the on-chip power supply network. First an approach to model the entire network by considering a homogeneous conductive foil is presented. The modification of the timing parameters of flipflops caused by spatial voltage drops through the IC surface are also investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sähkökäytön valintaan vaikuttavat useat eri tekijät. Sähkökäytön valinnan perusteena voidaan käyttää tietoa prosessin tai toimilaitteen fysikaalisesta käyttäytymisestä. Valinnan perusteena voi olla myös riittävän suorituskyvyn tarve prosessissa. Tässä työssä tutustutaan sähkökäytön valintaan vaikuttaviin tekijöihinja sähkökäytön mitoitukseen. Työssä on keskitytty yleisempien pienjännitemoottorityyppien ja niiden säätöjen käsittelyyn. Useissa prosesseissa vaaditaan monen moottorin käyttöä saman kuorman liikuttamisessa. Monimoottorikäyttöjen ohjauksen tuntemus auttaa ongelmatilanteiden ratkaisussa ja antaa perusteet monimoottorikäytön valinnalle. Tässä työssä käsitellään monimoottorikäyttöjen pyörimisnopeuserojen ja vääntömomenttien epätasaisuuteen liittyviä ongelmia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Taajuusmuuttajaohjatuissa nosturikäytöissä taakkaa laskettaessa syntyvä energia on muutettava lämmöksi jarruvastuksissa tai syötettävä takaisin sähköverkkoon esimerkiksi verkkovaihtosuuntaajalla. Verkkovaihtosuuntaajaa on tyypillisesti käytetty suurissa satamanostureissa, joiden tehontarve on yli 1000 kW. Työssä tutkitaan useista yhteiseen välipiiriin rinnankytketyistä nimellisteholtaan 250 kW:n verkkovaihtosuuntaajista koostuvan verkkoonjarrutuslaitteiston soveltuvuutta nosturikäyttöön. Lisäksi johdetaan yhtälöt verkkoonjarrutuslaitteiston virran laskemiseksi, kun nosturin mekaaniset arvot tunnetaan. Viidestä erityyppisestä nosturista esitellään esimerkkitoteutus rinnankytketyillä verkkovaihtosuuntaajilla. Aiemmin vastusjarruttavina toteutettujen nostureiden kustannuksia verrataan verkkovaihtosuuntaajilla toteutettuihin ratkaisuihin. Esimerkkinostureista esitetään nosturin työsykliin perustuva arvio verkkoonjarrutuksen tuomasta energian säästöstä. Tehtyjen mittausten perusteella käytetty menetelmä verkkovaihtosuuntaajien rinnan kytkemiseksi osoittautui nosturikäytössä toimivaksi. Kustannuslaskelmien perusteella verkkovaihtosuuntaajalla toteutetusta nosturista tulee materiaalikustannuksiltaan vastusjarruttavaa kalliimpi, vaikka paljon tilaa vievät vastuskaapit voidaankin jättää pois.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityössä on kehitetty kaksitasoisen jännitevälipiirillisen taajuusmuuttajan häviöiden simulointiin käytettävä simulointimalli osaksi säädettävän sähkömoottorikäytön simulointityökalua, jolla voidaan analysoida eri säätöalgoritmien, kuormituksen ja kytkentätaajuuden vaikutusta taajuusmuuttajan häviöihin. Aluksi on selvitetty yksityiskohtaisesti taajuusmuuttajan häviölähteet ja häviöiden fysikaalinen tausta. Taajuusmuuttajassa käytettäville komponenteille on esitetty simulointimalleja. Taajuusmuuttajan malli ja häviöiden laskenta-algoritmit on toteutettu C-kielellä. Taajuusmuuttajan malli vastaa perusrakenteeltaan ACS800-02-0260-5 - taajuusmuuttajaa. ACS800-02-0260-5 -taajuusmuuttajan häviöitä on simuloitu erilaisissa kuormitustilanteissa, ja simulointien tueksi taajuusmuuttajan häviöt on pyritty selvittämään laboratoriomittauksin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän työn tavoitteena on tarkastella keskijänniteverkonja sähköasemien kehittämistarpeita kahdella kohdealueella Kymenlaakson Sähköverkko Oy:n verkossa. Tarkastelun pohjatiedoiksi selvitettiin verkon sähköinen nykytila, luotettavuus, verkon topologia, kuormitusten jakautuminen ja muodostettiintulevaisuuden kuormitusennusteet. Lisäksi tarkasteltiin sähköasemien korvattavuus. Keskeiseksi työn sisällöksi muodostui kevytsähköasemien eri sijoituspaikkojen kannattavuustarkastelut, ottaen huomioon uuden keskijännitesyöttöpisteen vaikutukset keskijänniteverkon vahvistustarpeisiin, häviöihin ja käyttövarmuuteen. Laskelmat suoritettiin elinkaarikustannusperiaatteella huomioiden investointien, keskeytyksestä aiheutuneen haitan, häviöiden, kunnossapidon javiankorjauksen kustannukset. Työn tuloksena saatiin investointistrategiaehdotukset, joiden pohjalta verkkoyhtiö voi tehdä lähitulevaisuuden ratkaisuja sekä valmistautua tuleviin investointeihin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin ilmastonmuutoksen vaikutusta sähköverkkoliiketoimintaan. Ilmastonmuutosennusteet laadittiin RCAOilmastomallin antamien laskelmien perusteella. Ilmastomuuttujien ennusteet tehtiin ajanjaksolle 2016 - 2045 ja ennusteiden vertailujaksona käytettiin ajanjaksoa 1960 - 1990. Ennusteet laadittiin sadannalle, lämpötilalle, kuuraantumiselle, huurteelle, ukkoselle, routaantumiselle ja tuulisuudelle. Ilmastomuuttujien vaikutukset arvioitiin sekä tekniseltä että taloudelliselta kannalta. Ilmastonmuutoksen myötä on odotettavissa, että ilmastomuuttujien aiheuttamat rasitukset verkkoliiketoimintaa kohtaan tulevat olemaan niistä saatuja hyötyjä suuremmat. Vikamäärien kasvu on merkittävin ja haastavin ilmastonmuutoksen aiheuttama haitta. Ukkonen, lumikuormat ja tuuli tulevat aiheuttamaan nykyistä enemmän vikoja erityisesti keskijänniteverkoissa avojohdoille ellei verkkoja kehitetä vikavarmemmiksi. Lämpötilan nousun seurauksena lämmitystarve laskee ja jäähdytystarve nousee. Tämä näkyy merkittävimmin voimakkaasti lämpötilariippuvaisten käyttäjäryhmien sähkönkulutuksessa ja huippukuormissa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän työn tavoitteena oli laatia KSS Energia Oy:n keskijänniteverkon kehittämissuunnitelma. Tätä varten selvitettiin verkon nykytila ja sen toimivuus korvaustilanteissa. Suunnitelmaa varten laadittiin verkoston vuoteen 2020 asti ulottuva kuormitusennuste. Kehittämissuunnitelmassa paikannettiin alueet, joilla kuormitettavuus, korvattavuus tai oikosulkukestoisuus olisivat toimivansähkönjakelun esteinä tulevaisuudessa. Työn painopistealueiksi muodostuivat Vuolenkosken, Paimenpolun ja Valkealan alueet. Näiden alueiden kasvavan tehontarpeen tyydyttämiseksi selvitettiin uusien sähköasemien rakentamisvaihtoehtoja. Suunnitelmassa tarkasteltiin ja vertailtiin kolmen uuden sähköaseman rakentamista keskijänniteverkon saneerausvaihtoehtoon. Työssä selvitettiin myös miten alueen kuormituksen kasvun aiheuttama lisätehontarpeen jakelu voidaan hoitaa. Näiden alueiden kuormituksen kasvu edellyttää uusien sähköasemien rakentamista seuraavien 10vuoden kuluessa.