980 resultados para INJECTION CALIBRATION SYSTEM


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The usage of intensity modulated radiotherapy (IMRT) treatments necessitates a significant amount of patient-specific quality assurance (QA). This research has investigated the precision and accuracy of Kodak EDR2 film measurements for IMRT verifications, the use of comparisons between 2D dose calculations and measurements to improve treatment plan beam models, and the dosimetric impact of delivery errors. New measurement techniques and software were developed and used clinically at M. D. Anderson Cancer Center. The software implemented two new dose comparison parameters, the 2D normalized agreement test (NAT) and the scalar NAT index. A single-film calibration technique using multileaf collimator (MLC) delivery was developed. EDR2 film's optical density response was found to be sensitive to several factors: radiation time, length of time between exposure and processing, and phantom material. Precision of EDR2 film measurements was found to be better than 1%. For IMRT verification, EDR2 film measurements agreed with ion chamber results to 2%/2mm accuracy for single-beam fluence map verifications and to 5%/2mm for transverse plane measurements of complete plan dose distributions. The same system was used to quantitatively optimize the radiation field offset and MLC transmission beam modeling parameters for Varian MLCs. While scalar dose comparison metrics can work well for optimization purposes, the influence of external parameters on the dose discrepancies must be minimized. The ability of 2D verifications to detect delivery errors was tested with simulated data. The dosimetric characteristics of delivery errors were compared to patient-specific clinical IMRT verifications. For the clinical verifications, the NAT index and percent of pixels failing the gamma index were exponentially distributed and dependent upon the measurement phantom but not the treatment site. Delivery errors affecting all beams in the treatment plan were flagged by the NAT index, although delivery errors impacting only one beam could not be differentiated from routine clinical verification discrepancies. Clinical use of this system will flag outliers, allow physicists to examine their causes, and perhaps improve the level of agreement between radiation dose distribution measurements and calculations. The principles used to design and evaluate this system are extensible to future multidimensional dose measurements and comparisons. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current analysis examined the association of several demographic and behavioral variables with prior HIV testing within a population of injection drug users (IDUs) living in Harris County, Texas in 2005 (n=563). After completing the initial univariate analyses of all potential predictors, a multivariable model was created. This model was designed to guide future intervention efforts. Data used in this analysis were collected by the University of Texas School of Public Health in association with the Houston Department of Health and Human Services for the first IDU cycle of the National HIV Behavioral Surveillance System. About 76% of the IDUs reported previously being tested for HIV. Demographic variables that displayed a significant association with prior testing during the univariate analyses include age, race/ethnicity, birth outside the United States, education level, recent arrest, and current health insurance coverage. Several drug-related and sexual behaviors also demonstrated significant associations with prior testing, including age of first injection drug use, heroin use, methamphetamine use, source of needles or syringes, consistent use of new needles, recent visits to a shooting gallery or similar location, previous alcohol or drug treatment, condom use during their most recent sexual encounter, and having sexual partners who also used injection drugs. Additionally, the univariate analyses revealed that recent use of health or HIV prevention services was associated with previously testing for HIV. The final multivariable model included age, race/ethnicity, recent arrest, previous alcohol or drug treatment, and heroin use. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Injection drug users (IDUs) are at increased risk for HIV transmission due to unique risk behaviors, such as sharing needles. In Houston, IDUs account for 18% of all HIV/AIDS cases among Black males. ^ Objectives. This analysis compared demographic, behavioral, and psychosocial characteristics of needle sharing and non-sharing IDUs in a population of Black males in Harris County, Texas. ^ Methods. Data used for this analysis were from the second IDU cycle of the National HIV Behavioral Surveillance System. This dataset included a sample of 288 Black male IDUs. Univariate and multivariate statistical analysis were performed to determine statistically significant associations of needle sharing in this population and to create a functional model to inform local HIV prevention programs. ^ Results. Half of the participants in this analysis shared needles in the past 12 months. Compared to non-sharers, sharers were more likely to be homeless (OR=3.70, p<0.01) or arrested in the past year (OR=2.31, p<0.01), inject cocaine (OR=2.07, p<0.01), report male-to-male sex in the past year (OR=6.97, p<0.01), and to exchange sex for money or drugs. Sharers were less likely than non-sharers to graduate high school (OR=0.36, p<0.01), earn $5,000 or more a year (OR=1.15, p=0.05), get needles from a medical source (OR=0.59, p=0.03), and ever test for HIV (OR=0.17, p<0.01). Sharers were more likely to report depressive symptoms (OR=3.49, p<0.01), lower scores on the family support scale (mean difference 0.41, p=0.01) and decision-making confidence scale (mean difference 0.38, p<0.01), and greater risk-taking (mean difference -0.49, p<0.01) than non-sharers. In a multivariable logistic regression, sharers were less likely to have graduated high school (OR=0.33, p<0.01) and have been tested for HIV (OR=0.12, p<0.01) and were more likely to have been arrested in the past year (OR=2.3, p<0.01), get needles from a street source (OR=3.87, p<0.01), report male-to-male sex (OR=7.01, p<0.01), and have depressive symptoms (OR=2.36, p=0.02) and increased risk-taking (OR=1.78, p=0.01). ^ Conclusions. IDUs that shared needles are different from those that did not, reporting lower socioeconomic status, increased sexual and risk behaviors, increased depressive symptoms and increased risk-taking. These findings suggest that intervention programs that also address these demographic, behavioral, and psychosocial factors may be more successful in decreasing needle sharing among this population.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-resolution, small-bore PET systems suffer from a tradeoff between system sensitivity, and image quality degradation. In these systems long crystals allow mispositioning of the line of response due to parallax error and this mispositioning causes resolution blurring, but long crystals are necessary for high system sensitivity. One means to allow long crystals without introducing parallax errors is to determine the depth of interaction (DOI) of the gamma ray interaction within the detector module. While DOI has been investigated previously, newly available solid state photomultipliers (SSPMs) well-suited to PET applications and allow new modules for investigation. Depth of interaction in full modules is a relatively new field, and so even if high performance DOI capable modules were available, the appropriate means to characterize and calibrate the modules are not. This work presents an investigation of DOI capable arrays and techniques for characterizing and calibrating those modules. The methods introduced here accurately and reliably characterize and calibrate energy, timing, and event interaction positioning. Additionally presented is a characterization of the spatial resolution of DOI capable modules and a measurement of DOI effects for different angles between detector modules. These arrays have been built into a prototype PET system that delivers better than 2.0 mm resolution with a single-sided-stopping-power in excess of 95% for 511 keV g's. The noise properties of SSPMs scale with the active area of the detector face, and so the best signal-to-noise ratio is possible with parallel readout of each SSPM photodetector pixel rather than multiplexing signals together. This work additionally investigates several algorithms for improving timing performance using timing information from multiple SSPM pixels when light is distributed among several photodetectors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A reliable assessment of relevant substance flows is very important for environmental risk assessments and efficiency analysis of measures to reduce or avoid emissions of micropollutants like drugs to water systems. Accordingly, a detailed preparation of monitoring campaigns should include an accuracy check for the sampling configuration to prove the reliability of the monitoring results and the subsequent data processing. The accuracy of substance flow analyses is expected to be particularly weak for substances having high short-term variations of concentrations in sewage. This is especially the case linked to the observation of substance flows close to source in waste water systems. The verification of a monitoring configuration in a hospital sewer in Luxembourg is in the centre of interest of the case study presented here. A tracer test in the sewer system under observation is an essential element of the suggested accuracy check and provides valuable information for an uncertainty analysis. The results illustrate the importance of accuracy checks as an essential element of the preparation of monitoring campaigns. Moreover the study shows that continuous flow proportional sampling enables a representative observation of short-term peak loads of the iodinated x-ray contrast media iobitridol close to source.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The oceans play a critical role in the Earth's climate, but unfortunately, the extent of this role is only partially understood. One major obstacle is the difficulty associated with making high-quality, globally distributed observations, a feat that is nearly impossible using only ships and other ocean-based platforms. The data collected by satellite-borne ocean color instruments, however, provide environmental scientists a synoptic look at the productivity and variability of the Earth's oceans and atmosphere, respectively, on high-resolution temporal and spatial scales. Three such instruments, the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) onboard ORBIMAGE's OrbView-2 satellite, and two Moderate Resolution Imaging Spectroradiometers (MODIS) onboard the National Aeronautic and Space Administration's (NASA) Terra and Aqua satellites, have been in continuous operation since September 1997, February 2000, and June 2002, respectively. To facilitate the assembly of a suitably accurate data set for climate research, members of the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project and SeaWiFS Project Offices devote significant attention to the calibration and validation of these and other ocean color instruments. This article briefly presents results from the SIMBIOS and SeaWiFS Project Office's (SSPO) satellite ocean color validation activities and describes the SeaWiFS Bio-optical Archive and Storage System (SeaBASS), a state-of-the-art system for archiving, cataloging, and distributing the in situ data used in these activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

B/Ca ratios in Cibicides mundulus and Cibicides wuellerstorfi have been shown to correlate with the degree of calcite saturation in seawater (D[CO32-]). In the South Pacific, a region of high importance in the global carbon cycle, these species are not continuously present in down-core records. Small numbers of epibenthic foraminifera in samples present an additional challenge, which can be overcome by using laser ablation-inductively coupled-mass spectrometry (LA-ICP-MS). We present a laser ablation based core-top calibration for Cibicides cf. wuellerstorfi, a C. wuellerstorfi morphotype that is abundant in the South Pacific and extend the existing global core top calibration for C. mundulus and C. wuellerstorfi to this region. B/Ca in C. cf. wuellerstorfi are linearly correlated with D[CO32-] and possibly display a higher sensitivity to calcite saturation changes than C. wuellerstorfi. Trace element profiles through C. wuellerstorfi and C. mundulus reveal an intra-shell B/Ca variation of ±36% around the mean shell value. Mg/Ca and B/Ca display opposite trends along the shell. Both phenomena likely result from ontogenetic effects. Intra-shell variability equals intra-sample variability, mean sample B/Ca values can thus be reliably calculated from averaged spot results of single specimen. In the global B/Ca-D[CO32-] range, we observe an inverse relationship between water mass age and D[CO32-].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Tara Oceans Expedition (2009-2013) sampled the world oceans on board a 36 m long schooner, collecting environmental data and organisms from viruses to planktonic metazoans for later analyses using modern sequencing and state-of-the-art imaging technologies. Tara Oceans Data are particularly suited to study the genetic, morphological and functional diversity of plankton. The present data set provides continuous measurements made with a WETLabs Eco-FL sensor mounted on the flowthrough system between June 4th, 2011 and March 30th, 2012. Data was recorded approximately every 10s. Two issues affected the data: 1. Periods when the water 0.2µm filtered water were used as blanks and 2. Periods where fluorescence was affected by non-photochemical quenching (NPQ, chlorophyll fluorescence is reduced when cells are exposed to light, e.g. Falkowski and Raven, 1997). Median data and their standard deviation were binned to 5min bins with period of light/dark indicated by an added variable (so that NPQ affected data could be neglected if the user so chooses). Data was first calibrated using HPLC data collected on the Tara (there were 36 data within 30min of each other). Fewer were available when there was no evident NPQ and the resulting scale factor was 0.0106 mg Chl m-3/count. To increase the calibration match-ups we used the AC-S data which provided a robust estimate of Chlorophyll (e.g. Boss et al., 2013). Scale factor computed over a much larger range of values than HPLC was 0.0088 mg Chl m-3/count (compared to 0.0079 mg Chl m-3/count based on manufacturer). In the archived data the fluorometer data is merged with the TSG, raw data is provided as well as manufacturer calibration constants, blank computed from filtered measurements and chlorophyll calibrated using the AC-S. For a full description of the processing of the Eco-FL please see Taillandier, 2015.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Tara Oceans Expedition (2009-2013) sampled the world oceans on board a 36 m long schooner, collecting environmental data and organisms from viruses to planktonic metazoans for later analyses using modern sequencing and state-of-the-art imaging technologies. Tara Oceans Data are particularly suited to study the genetic, morphological and functional diversity of plankton. The present data set provides continuous pH measurements made during 2013 expedition with a Satlantic SeaFET instrument that was connected to the flowthrough system. Data calibration was performed according to Bresnahan et al. (2014) (using spectrophotometric pH measurements on discrete samples (Clayton and Byrne 1993). pH_internal values were taken to calibrate the data (rather than pH_external) because of the better calibration coefficient (there was no trend associated with it). The equations of Clayton and Byrne (1993) was used to compute pH from the measured absorbance values at the temperature of measurement. The data was converted to in situ temperature using the "CO2-sys" program which can be downloaded from http://cdiac.ornl.gov/ftp/co2sys/.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Tara Oceans Expedition (2009-2013) sampled the world oceans on board a 36 m long schooner, collecting environmental data and organisms from viruses to planktonic metazoans for later analyses using modern sequencing and state-of-the-art imaging technologies. Tara Oceans Data are particularly suited to study the genetic, morphological and functional diversity of plankton. The present data set provides continuous measurements of partial pressure of carbon dioxide (pCO2), using a ProOceanus CO2-Pro instrument mounted on the flowthrough system. This automatic sensor is fitted with an equilibrator made of gas permeable silicone membrane and an internal detection loop with a non-dispersive infrared detector of PPSystems SBA-4 CO2 analyzer. A zero-CO2 baseline is provided for the subsequent measurements circulating the internal gas through a CO2 absorption chamber containing soda lime or Ascarite. The frequency of this automatic zero point calibration was set to be 24 hours. All data recorded during zeroing processes were discarded with the 15-minute data after each calibration. The output of CO2-Pro is the mole fraction of CO2 in the measured water and the pCO2 is obtained using the measured total pressure of the internal wet gas. The fugacity of CO2 (fCO2) in the surface seawater, whose difference with the atmospheric CO2 fugacity is proportional to the air-sea CO2 fluxes, is obtained by correcting the pCO2 for non-ideal CO2 gas concentration according to Weiss (1974). The fCO2 computed using CO2-Pro measurements was corrected to the sea surface condition by considering the temperature effect on fCO2 (Takahashi et al., 1993). The surface seawater observations that were initially estimated with a 15 seconds frequency were averaged every 5-min cycle. The performance of CO2-Pro was adjusted by comparing the sensor outputs against the thermodynamic carbonate calculation of pCO2 using the carbonic system constants of Millero et al. (2006) from the determinations of total inorganic carbon (CT ) and total alkalinity (AT ) in discrete samples collected at sea surface. AT was determined using an automated open cell potentiometric titration (Haraldsson et al. 1997). CT was determined with an automated coulometric titration (Johnson et al. 1985; 1987), using the MIDSOMMA system (Mintrop, 2005). fCO2 data are flagged according to the WOCE guidelines following Pierrot et al. (2009) identifying recommended values and questionable measurements giving additional information about the reasons of the questionability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main purpose of robot calibration is the correction of the possible errors in the robot parameters. This paper presents a method for a kinematic calibration of a parallel robot that is equipped with one camera in hand. In order to preserve the mechanical configuration of the robot, the camera is utilized to acquire incremental positions of the end effector from a spherical object that is fixed in the word reference frame. The positions of the end effector are related to incremental positions of resolvers of the motors of the robot, and a kinematic model of the robot is used to find a new group of parameters which minimizes errors in the kinematic equations. Additionally, properties of the spherical object and intrinsic camera parameters are utilized to model the projection of the object in the image and improving spatial measurements. Finally, the robotic system is designed to carry out tracking tasks and the calibration of the robot is validated by means of integrating the errors of the visual controller.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A generic bio-inspired adaptive architecture for image compression suitable to be implemented in embedded systems is presented. The architecture allows the system to be tuned during its calibration phase. An evolutionary algorithm is responsible of making the system evolve towards the required performance. A prototype has been implemented in a Xilinx Virtex-5 FPGA featuring an adaptive wavelet transform core directed at improving image compression for specific types of images. An Evolution Strategy has been chosen as the search algorithm and its typical genetic operators adapted to allow for a hardware friendly implementation. HW/SW partitioning issues are also considered after a high level description of the algorithm is profiled which validates the proposed resource allocation in the device fabric. To check the robustness of the system and its adaptation capabilities, different types of images have been selected as validation patterns. A direct application of such a system is its deployment in an unknown environment during design time, letting the calibration phase adjust the system parameters so that it performs efcient image compression. Also, this prototype implementation may serve as an accelerator for the automatic design of evolved transform coefficients which are later on synthesized and implemented in a non-adaptive system in the final implementation device, whether it is a HW or SW based computing device. The architecture has been built in a modular way so that it can be easily extended to adapt other types of image processing cores. Details on this pluggable component point of view are also given in the paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Los estudios realizados hasta el momento para la determinación de la calidad de medida del instrumental geodésico han estado dirigidos, fundamentalmente, a las medidas angulares y de distancias. Sin embargo, en los últimos años se ha impuesto la tendencia generalizada de utilizar equipos GNSS (Global Navigation Satellite System) en el campo de las aplicaciones geomáticas sin que se haya establecido una metodología que permita obtener la corrección de calibración y su incertidumbre para estos equipos. La finalidad de esta Tesis es establecer los requisitos que debe satisfacer una red para ser considerada Red Patrón con trazabilidad metrológica, así como la metodología para la verificación y calibración de instrumental GNSS en redes patrón. Para ello, se ha diseñado y elaborado un procedimiento técnico de calibración de equipos GNSS en el que se han definido las contribuciones a la incertidumbre de medida. El procedimiento, que se ha aplicado en diferentes redes para distintos equipos, ha permitido obtener la incertidumbre expandida de dichos equipos siguiendo las recomendaciones de la Guide to the Expression of Uncertainty in Measurement del Joint Committee for Guides in Metrology. Asimismo, se han determinado mediante técnicas de observación por satélite las coordenadas tridimensionales de las bases que conforman las redes consideradas en la investigación, y se han desarrollado simulaciones en función de diversos valores de las desviaciones típicas experimentales de los puntos fijos que se han utilizado en el ajuste mínimo cuadrático de los vectores o líneas base. Los resultados obtenidos han puesto de manifiesto la importancia que tiene el conocimiento de las desviaciones típicas experimentales en el cálculo de incertidumbres de las coordenadas tridimensionales de las bases. Basándose en estudios y observaciones de gran calidad técnica, llevados a cabo en estas redes con anterioridad, se ha realizado un exhaustivo análisis que ha permitido determinar las condiciones que debe satisfacer una red patrón. Además, se han diseñado procedimientos técnicos de calibración que permiten calcular la incertidumbre expandida de medida de los instrumentos geodésicos que proporcionan ángulos y distancias obtenidas por métodos electromagnéticos, ya que dichos instrumentos son los que van a permitir la diseminación de la trazabilidad metrológica a las redes patrón para la verificación y calibración de los equipos GNSS. De este modo, ha sido posible la determinación de las correcciones de calibración local de equipos GNSS de alta exactitud en las redes patrón. En esta Tesis se ha obtenido la incertidumbre de la corrección de calibración mediante dos metodologías diferentes; en la primera se ha aplicado la propagación de incertidumbres, mientras que en la segunda se ha aplicado el método de Monte Carlo de simulación de variables aleatorias. El análisis de los resultados obtenidos confirma la validez de ambas metodologías para la determinación de la incertidumbre de calibración de instrumental GNSS. ABSTRACT The studies carried out so far for the determination of the quality of measurement of geodetic instruments have been aimed, primarily, to measure angles and distances. However, in recent years it has been accepted to use GNSS (Global Navigation Satellite System) equipment in the field of Geomatic applications, for data capture, without establishing a methodology that allows obtaining the calibration correction and its uncertainty. The purpose of this Thesis is to establish the requirements that a network must meet to be considered a StandardNetwork with metrological traceability, as well as the methodology for the verification and calibration of GNSS instrumental in those standard networks. To do this, a technical calibration procedure has been designed, developed and defined for GNSS equipment determining the contributions to the uncertainty of measurement. The procedure, which has been applied in different networks for different equipment, has alloweddetermining the expanded uncertainty of such equipment following the recommendations of the Guide to the Expression of Uncertainty in Measurement of the Joint Committee for Guides in Metrology. In addition, the three-dimensional coordinates of the bases which constitute the networks considered in the investigationhave been determined by satellite-based techniques. There have been several developed simulations based on different values of experimental standard deviations of the fixed points that have been used in the least squares vectors or base lines calculations. The results have shown the importance that the knowledge of experimental standard deviations has in the calculation of uncertainties of the three-dimensional coordinates of the bases. Based on high technical quality studies and observations carried out in these networks previously, it has been possible to make an exhaustive analysis that has allowed determining the requirements that a standard network must meet. In addition, technical calibration procedures have been developed to allow the uncertainty estimation of measurement carried outby geodetic instruments that provide angles and distances obtained by electromagnetic methods. These instruments provide the metrological traceability to standard networks used for verification and calibration of GNSS equipment. As a result, it has been possible the estimation of local calibration corrections for high accuracy GNSS equipment in standardnetworks. In this Thesis, the uncertainty of calibration correction has been calculated using two different methodologies: the first one by applying the law of propagation of uncertainty, while the second has applied the propagation of distributions using the Monte Carlo method. The analysis of the obtained results confirms the validity of both methodologies for estimating the calibration uncertainty of GNSS equipment.