786 resultados para Hand Strength
Resumo:
Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.
Resumo:
Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors’ accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application’s satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.
Resumo:
Introduction and Objectives. Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons’ performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Materials and Methods. Each participant performed 3 laparoscopic tasks—Peg transfer, Wire chaser, Knot—in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Results. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). Conclusion. The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures.
Resumo:
Foi aplicada uma versão reduzida do "Face-Hand Test", o FHT-R, em 91 pessoas com 65 anos ou mais em uma amostra ao acaso de idosos vivendo na comunidade (São Paulo, Brasil), com objetivo de testar a habilidade do instrumento em detectar as síndromes psicorgânicas. Os escores do FHT-R foram comparados com as avaliações de um psiquiatra utilizando uma entrevista semi-estruturada, a "Clinical Interview Schedule". Cinco pessoas foram consideradas como sendo portadoras de distúrbios psicorgânicos e 86 como não sendo portadoras de tais distúrbios. No ponto de corte 0/1 os coeficientes de validação obtidos foram: sensibilidade 60%, especificidade 94%, valor prognóstico positivo 38%, valor prognóstico negativo 98%, e taxa de classificação incorreta 8%. A utilização do Teste em pesquisas epidemiológicas é discutida no corpo do trabalho.
Resumo:
Abstract: Background: Familial amyloidotic polyneuropathy (FAP) is a neurodegenerative disease leading to sensory and motor polyneuropathies, and functional limitations. Liver transplantation is the only treatment for FAP, requiring medication that negatively affects bone and muscle metabolism. The aim of this study was to compare body composition, levels of specific strength, level of physical disability risk, and functional capacity of transplanted FAP patients (FAPTx) with a group of healthy individuals (CON). Methods: A group of patients with 48 FAPTx (28 men, 20 women) was compared with 24 CON individuals (14 men, 10 women). Body composition was assessed by dual-energy X-ray absorptiometry, and total skeletal muscle mass (TBSMM) and skeletal muscle index (SMI) were calculated. Handgrip strength was measured for both hands as was isometric strength of quadriceps. Muscle quality (MQ) was ascertained by the ratio of strength to muscle mass. Functional capacity was assessed by the six-minute walk test. Results: Patients with FAPTx had significantly lower functional capacity, weight, body mass index, total fat mass, TBSMM, SMI, lean mass, muscle strength, MQ, and bone mineral density. Conclusion: Patients with FAPTx appear to be at particularly high risk of functional disability, suggesting an important role for an early and appropriately designed rehabilitation program.
Resumo:
Liver transplantation is the unique treatment for several end-stage diseases. Familial Amiloidotic Polineuropathy (FAP) is a neurodegenerative disease related with systemic deposition of amyloidal fiber mainly on peripheral nervous system, clinically translated by an autonomous sensitive-motor neuropathy with severe functional limitations in some cases. The unique treatment for FAP disease is a liver transplant with a very aggressive medication to muscle metabolism and force production. To our knowledge there are no quantitative characterizations of body composition, strength or functional capacity in this population.
Resumo:
Familial Amyloidotic Polyneuropathy FAP)- A neurodegenerative disease related with systemic deposition of amyloid fibers mainly at the level of the peripheral nervous system. Clinically, the disease is characterized by an autonomous sensitive-motor neuropathy, beginning nearly always in foot, and subsequently involving the hands. Purpose: Compare the levels of hand grip strength (peak force) in FAP patients with (FAPT) or without (FAPNT) liver transplant and in a healthy group (HG).
Resumo:
Purpose: to investigate the relationship between knee muscle strength, balance and functional independence within the first month after stroke. Relevance: cerebral vascular disease is one of the main causes of morbidity, disability and mortality in developed countries. Problems with movement control are frequent after stroke. Lower limb weakness and impaired balance are common problems that are related with the risk of falls and are likely to interfere with the ability to perform daily life activities. Physiotherapy intervention usually starts early after stroke and addresses impairments related to movement and posture in order to improve motor recovery and restore function.
Resumo:
Cerebral vascular disease is one of the main causes of morbidity, disability and mortality in developed countries. Problems with movement control are frequent after stroke. Lower limb weakness and impaired balance are common problems that are related with the risk of falls and are likely to interfere with the ability to perform daily life activities. Physiotherapy intervention usually starts early after stroke and addresses impairments related to movement and posture in order to improve motor recovery and restore function. Purpose: to investigate the relationship between knee muscle strength, balance and functional independence within the first month after stroke.
Resumo:
Liver transplantation is the unique treatment for several end stage diseases. Familial Amiloidotic Polineuropathy (FAP) is a neurodegenerative disease related with systemic deposition of amyloidal fibre mainly on peripheral nervous system, clinically translated by an autonomous sensitive-motor neuropathy with severe functional limitations in some cases. The unique treatment for FAP disease is a liver transplant with a very aggressive medication to muscle metabolism and force production. To our knowledge there are no quantitative characterizations of body composition, strength or functional capacity in this population. The purpose of this study was to compare levels of specific strength (isometric strength adjusted by lean mass or muscle quality) and functional capacity (meters in 6 minutes walk test) between FAP patients after a liver transplant (4.1±2 months after transplant surgery) (FAPT) and a healthy group (HG).
Resumo:
Introdução – Avaliar a força de preensão mostrou ser de primordial importância pela sua relação com a capacidade funcional dos indivíduos, permitindo determinar níveis de risco para incapacidade futura e, assim, estabelecer estratégias de prevenção. Grande parte dos estudos utiliza o dinamómetro hidráulico JAMAR que fornece o valor da força isométrica obtida durante a execução do movimento de preensão palmar. Contudo, existem outros dinamómetros disponíveis, como é o caso do dinamómetro portátil computorizado E‑Link (Biometrics) que fornece o valor da força máxima (peak force), para além de outras variáveis, como a taxa de fadiga. Não existem, contudo, estudos que nos permitam aceitar e comparar ou não os valores obtidos com os dois equipamentos e porventura utilizá‑los indistintamente. Objetivos – Avaliar a concordância entre as medições da força de preensão (força máxima ou peak force em Kg) obtida a partir de dois equipamentos diferentes (dinamómetros portáteis): um computorizado (E‑Link, Biometrics) e outro hidráulico (JAMAR). Metodologia – Foram avaliados 29 indivíduos (13H; 16M; 22±7 anos; 23,2±3,3 kg/m2) em 2 dias consecutivos, na mesma altura do dia. A posição de teste escolhida foi a recomendada pela Associação Americana de Terapeutas Ocupacionais e foi escolhido o melhor resultado de entre 3 tentativas para a mão dominante. Realizou‑se uma análise correlacional entre os valores obtidos na variável analisada em cada equipamento (coeficiente de Spearman) e uma análise de Bland & Altman para verificar a concordância entre as duas medições. Resultados – O coeficiente de correlação entre as duas medições foi elevado (rS= 0,956; p<0,001) e, pela análise de Bland & Altman, os valores obtidos encontram‑se todos dentro do intervalo da média±2SD. Conclusões – As duas medições mostraram ser concordantes, revelando que os dinamómetros testados podem ser comparáveis ou utilizados indistintamente em diferentes estudos e populações. ABSTRACT: Introduction – Assess grip strength has proved to be of vital importance because of its relationship with functional capacity of individuals, in order to determine levels of risk for future disability and thereby establish prevention strategies. Most studies use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement. However, there are other dynamometers available, such as portable computerized dynamometer E‑Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue. There are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. Purpose – To evaluate the agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E‑Link, Biometrics) and a hydraulic (JAMAR). Methodology – 29 subjects (13H, 16M, 22 ± 7 years, 23.2 ± 3.3 kg/m2) were assessed on two consecutive days at the same time of day. The test position chosen was recommended by the American Association of Occupational Therapists and was considered the best result from three attempts for the dominant hand. A correlation was studied between values obtained in the variable analyzed in each equipment (Spearman coefficient) and Bland‑Altman analysis to assess the agreement between the two measurements. Results – The correlation coefficient between the two measurements was high (rs = 0,956, p <0,001) and Bland & Altman analysis of the values obtained are all within the range of mean±2SD. Conclusions – The two measurements were shown to be concordant, revealing that the tested dynamometers can be comparable or used interchangeably in different studies and populations.
Resumo:
A síndrome do túnel carpiano (STC) é considerada a neuropatia compressiva mais comum na população. É causada pela compressão directa sobre o nervo mediano no interior do túnel carpiano, que origina parestesias, dor na mão e disfunção muscular. Como consequência destes sintomas, os indivíduos vêem comprometida a sua funcionalidade ao nível das ocupações e, por consequência, alterado o seu desempenho ocupacional. Este trabalho tem como objectivo principal verificar de que forma a utilização da tala nocturna influencia a funcionalidade do indivíduo com STC. Concomitantemente pretende-se definir em que medida alterações das forças de preensão palmar e de pinças se relaciona com o uso da tala. Por último, identificar quais as variáveis sócio - demográficas e as que caracterizam a patologia que estão relacionadas com o problema em estudo e aos valores obtidos com as escalas do Boston Carpal Tunnel Questionnaire (BQTC), nos indivíduos dos grupos controlo e experimental. A amostra é constituída por 22 indivíduos no grupo controlo e 24 no grupo experimental, com diagnóstico de STC ligeiro e moderado. Foram aplicados o BCTQ, o dinamómetro e o pinch meter de Jamar. Os resultados deste estudo mostram uma diminuição significativa da sintomatologia da STC, após a aplicação da tala, nos momentos de reavaliação e follow up, (p=0,000 e p=0,004), assim como um aumento significativo da funcionalidade nos dois momentos (p=0,000 e p=0,004). Deste estudo conclui-se que a utilização da tala nocturna beneficia os indivíduos com STC ligeiro e moderado.
Resumo:
Mestrado em Fisioterapia.
Resumo:
A Síndrome do Canal Cárpico (SCC) é a neuropatia compressiva mais comum do membro superior, causada pela compressão direta sobre o nervo mediano no interior do canal cárpico.Os resultados deste estudo mostram em cada um dos grupos, após a intervenção, uma melhoria estatisticamente significativa da sintomatologia no G-AFN (p=0,02) e no GTRN/ EAA (p=0,004) e uma melhoria estatisticamente significativa do estado funcional no G-AFN (p=0,022). Verificamos também em cada um dos grupos, após a intervenção, uma melhoria estatisticamente significativa na “Força de preensão” (p=0,005), na “Pinça polegar/dedo indicador” (p=0,021), na “Pinça polegar/dedo médio” (p=0,026) e “Pinça polegar/dedo anular” (p=0,026) no G-AFN, e uma melhoria estatisticamente significativa na “Pinça polegar/indicador” (p=0,016), na “Pinça polegar/dedo médio” (p=0,035), na “Pinça polegar/dedo anular” (p=0,010), na “Pinça trípode” (p=0,005) e na “Pinça lateral” (p=0,051) no G-TRN/EAA. Após a intervenção, não verificamos diferenças estatisticamente significativas nos valores das escalas de gravidade de sintomas (p=0,853) e de estado funcional (p=0,148) entre os grupos, mas diferenças estatisticamente significativas nos valores dos testes neurofisiológicos (p=0,047) e força de preensão da mão (p=0,005). Do estudo, concluímos que a utilização da intervenção articular/fascial/neural (AFN) e a intervenção com tala de repouso noturna e exercícios de auto alongamento (TRN/EAA), beneficia os indivíduos com SCC não severa, como nos casos incipientes, ligeiros ou moderados. Os indivíduos com esta condição clínica apresentam sintomatologia caraterística de dor, parestesia, especialmente noturna e disfunção muscular da mão. Tais manifestações originam perda funcional com implicações nas áreas de desempenho ocupacional, nomeadamente, nas atividades da vida diária, produtivas e de lazer. O tratamento conservador na SCC não severa, como nos casos incipientes, ligeiros e moderados, apesar de controverso, é recomendado. O tema suscita o nosso interesse, razão pela qual nos propomos realizar um estudo experimental em indivíduos com o diagnóstico clínico de SCC não severa e aplicar num grupo a intervenção articular, fascial e neural (AFN) e noutro grupo a intervenção com tala de repouso noturna e exercícios de auto alongamento (TRN/EAA). O estudo tem como principais objetivos, por um lado, verificar o impacto das intervenções em cada um dos grupos e, por outro lado, comparar o seu impacto entre os grupos, no que respeita à gravidade de sintomas, ao estado funcional, à força de preensão da mão e força de pinças finas. Fomos também comparar os resultados dos testes neurofisiológicos (Velocidade de Condução Motora) antes e depois da intervenção AFN e da intervenção com TRN/EAA, e averiguar o seu impacto nos valores da latência motora distal e da velocidade de condução sensitiva, entre os grupos. Identificamos também quais as variáveis sócio demográficas e as que caraterizam a patologia que estão relacionadas com o problema em estudo e com os valores obtidos com as escalas do Boston Carpal Tunnel Questionnaire (BCTQ), no grupo articular, fascial e neural (G-AFN) e no grupo com tala de repouso noturna e exercícios de auto alongamento (G-TRN/EAA). Para a concretização do estudo, recorremos a uma amostra de 23 indivíduos de ambos os sexos do Hospital Curry Cabral, Empresa Pública Empresarial -Centro Hospitalar de Lisboa Central (HCC, EPE -CHLC).
Resumo:
Analisar: níveis de fadiga, força de preensão, HRQoL, níveis de actividade física. Será que se alteram em doentes PAF após o transplante de fígado? Dado que os níveis de actividade física se encontram abaixo dos valores mínimos recomendados deveria ser encontrada uma estratégia de aumento do tempo dispendido na actividade física leve a moderada idealmente no PRÉ TRANSPLANTE.