978 resultados para Generation Time Effect


Relevância:

40.00% 40.00%

Publicador:

Resumo:

At head of title: State of Indiana. Dept. of Public Instruction ...

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bibliography: leaves 39-41.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Observation of the occurrence of protective muscle activity is advocated in assessment of the peripheral nervous system by means of neural provocation tests. However, no studies have yet demonstrated abnormal force generation in a patient population. Objectives: To analyze whether aberrations in shoulder girdle-elevation force during neural tissue provocation testing for the median nerve (NTPTI) can be demonstrated, and whether possible aberrations can be normalized following cervical mobilization. Study Design: A single-blind randomized comparative controlled study. Setting: Laboratory setting annex in a manual therapy teaching practice. Participants: Twenty patients with unilateral or bilateral neurogenic cervicobrachial pain. Methods: During the NTPTI, we used a load cell and electrogoniometer to record continuously the shoulder-girdle elevation force in relation to the available range of elbow extension. Following randomization, we analyzed the immediate treatment effects of a cervical contralateral lateral glide mobilization technique (experimental group) and therapeutic ultrasound (control group). Results: On the involved side, the shoulder-girdle elevation force occur-red earlier, and the amount of force at the end of the test was substantially, though not significantly, greater than that on the uninvolved side at the corresponding range of motion. Together with a significant reduction in pain perception after cervical mobilization, a clear tendency toward normalization of the force curve could be observed, namely, a significant decrease in force generation and a delayed onset. The control group demonstrated no differences. Conclusions: Aberrations in force generation during neural, provocation testing are present in patients with neurogenic pain and can be normalized with appropriate treatment modalities.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study explores whether the introduction of selectively trained radiographers reporting Accident and Emergency (A&E) X-ray examinations or the appendicular skeleton affected the availability of reports for A&E and General Practitioner (GP) examinations at it typical district general hospital. This was achieved by analysing monthly data on A&E and GP examinations for 1993 1997 using structural time-series models. Parameters to capture stochastic seasonal effects and stochastic time trends were included ill the models. The main outcome measures were changes in the number, proportion and timeliness of A&E and GP examinations reported. Radiographer reporting X-ray examinations requested by A&E was associated with it 12% (p = 0.050) increase in the number of A&E examinations reported and it 37% (p

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A supersweet sweet corn hybrid, Pacific H5, was grown under field conditions in South-East Queensland to study the effects of harvest time and drying conditions on seed quality. Cobs were harvested at different times to obtain seed with two moisture percentage ranges (20-30% and 40-50%) and dried to 12% moisture under different combinations of drying temperatures (30 degrees C, 40 degrees C and 50 degrees C) and air velocities (1.25 m/s, 2.75 m/s and 4.30 m/s). Dried seed was stored at 30 degrees C with bimonthly monitoring of seed quality for 12 months. For standard as well as cold test germinations, statistical analysis yielded significant main effects for temperature, air velocity and harvest moisture content and significant interactions for drying temperature by harvest moisture and drying temperature by air velocity. Germination at the beginning of storage was unaffected by drying temperatures up to 40 degrees C regardless of harvest moisture but was lower at 50 degrees C for higher moisture. However, germination at the end of the storage period of 12 months was greatest for seed harvested at higher moisture and dried at temperatures up to 40 degrees C. Germination was not affected by air velocity for drying temperatures up to 40 degrees C but at 50 degrees C it generally decreased with increase in air velocity. To slow down seed deterioration during storage, it is recommended that sweet corn seed should be harvested at a higher moisture range (40-50%) and dried at 40 degrees C and 4.30 m/s air velocity. The drying temperature can be raised to 50 degrees C for seed harvested at a low moisture range (20-30%) provided the air velocity is kept low (1.25 m/s).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The high intensity zone within the Jameson Cell is the downcomer. It is largely external and separated from the flotation tank. This, together with operation of the downcomer under vacuum, rather than at elevated pressure and the absence of moving parts, allows ready access to the high intensity zone for measurement and analysis. Experimentation was conducted allowing measurements of recovery for residence times of between 20 milliseconds and ten seconds within the downcomer of a Jameson Cell. The affect of aeration rate on the recovery of different particle sizes was also studied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Each year growers are faced with the decision of when to harvest individual blocks of sugarcane throughout the harvest season. This decision influences the yield of the current crop and can affect the yield in the following season. Growers must therefore decide which blocks to harvest early and which to harvest later in the harvest season. Usually, the latest harvested cane is the lowest yielding the following year (the �late harvest� effect). Block productivity data from Tully were used to determine the effects of harvest timing on cane yield of the current and subsequent crop. The results are tabulated to provide a ready reference to these time of harvest effects on the current and future crop in either a single year or over the full crop cycle for the Tully district.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: To assess the repeatability of Eger macular stressometer (EMS) measures of photostress recovery and determine their association with other measures of visual function. Methods: EMS photostress recovery time was measured in 90 patients with bilateral exudative age related macular degeneration (AMD), 19 with bilateral atrophic AMD and 47 with both forms of the condition (mean age 79 (SD 13) years). Measurements were made on two occasions separated by 1 year. Intrasession repeatability was assessed by repeating the measures after a 10 minute recovery period at the first visit. Distance visual acuity was measured with a logMAR chart, near visual acuity with a MNRead chart at 25 cm, contrast sensitivity with a Pelli-Robson chart, and the presence of central visual disturbance assessed with an Amsler grid. A questionnaire was used to assess self reported difficulties with glare recovery. Results: The average EMS recovery time was 11.0 (SD 8.9) seconds, decreasing by 1.6 (5.2) seconds on repeated measurement (p<0.05). EMS photostress recovery was not correlated with visual function measures or subjective difficulties with lights (p>0.05). EMS photostress recovery time did not predict those whose vision decreased over the following year compared with those among whom it remained stable. Conclusions: The EMS test is not a useful tool in determining the severity or progression of AMD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To assess repeatability and reproducibility, to determine normative data, and to investigate the effect of age-related macular disease, compared with normals, on photostress recovery time measured using the Eger Macular Stressometer (EMS). Method: The study population comprised 49 healthy eyes of 49 participants. Four EMS measurements were taken in two sessions separated by 1 h by two practitioners, with reversal of order in the second session. EMS readings were also taken from 17 age-related maculopathy (ARM), and 12 age-related macular degeneration (AMD), affected eyes. Results: EMS readings are repeatable to within ± 7 s. There is a statistically significant difference between controls and ARM affected eyes (t = 2.169, p = 0.045), and AMD affected eyes (t = 2.817, p = 0.016). The EMS is highly specific, and demonstrates sensitivity of 29% for ARM, and 50% for AMD. Conclusions: The EMS may be a useful screening test for ARM, however, direct illumination of the macula of greater intensity and longer duration may yield less variable results. © 2004 The College of Optometrists.