The effect of residence time and aeration on coal recovery within the high density zone of a flotation machine
Contribuinte(s) |
Graeme J. Jameson |
---|---|
Data(s) |
01/01/2005
|
Resumo |
The high intensity zone within the Jameson Cell is the downcomer. It is largely external and separated from the flotation tank. This, together with operation of the downcomer under vacuum, rather than at elevated pressure and the absence of moving parts, allows ready access to the high intensity zone for measurement and analysis. Experimentation was conducted allowing measurements of recovery for residence times of between 20 milliseconds and ten seconds within the downcomer of a Jameson Cell. The affect of aeration rate on the recovery of different particle sizes was also studied. |
Identificador | |
Idioma(s) |
eng |
Publicador |
Australasian Institute of Mining and Metallurgy (AusIMM) |
Palavras-Chave | #Jameson Cell #high intensity zone #downcomer #aeration rate #E1 #290702 Mineral Processing #640300 First Stage Treatment of Ores and Minerals |
Tipo |
Conference Paper |