864 resultados para Fixed bed reactor
Drag reduction by polyethylene glycol in the tail arterial bed of normotensive and hypertensive rats
Resumo:
This study was designed to evaluate the effect of drag reducer polymers (DRP) on arteries from normotensive (Wistar) and spontaneously hypertensive rats (SHR). Polyethylene glycol (PEG 4000 at 5000 ppm) was perfused in the tail arterial bed with (E+) and without endothelium (E-) from male, adult Wistar (N = 14) and SHR (N = 13) animals under basal conditions (constant flow at 2.5 mL/min). In these preparations, flow-pressure curves (1.5 to 10 mL/min) were constructed before and 1 h after PEG 4000 perfusion. Afterwards, the tail arterial bed was fixed and the internal diameters of the arteries were then measured by microscopy and drag reduction was assessed based on the values of wall shear stress (WSS) by computational simulation. In Wistar and SHR groups, perfusion of PEG 4000 significantly reduced pulsatile pressure (Wistar/E+: 17.5 ± 2.8; SHR/E+: 16.3 ± 2.7%), WSS (Wistar/E+: 36; SHR/E+: 40%) and the flow-pressure response. The E- reduced the effects of PEG 4000 on arteries from both groups, suggesting that endothelial damage decreased the effect of PEG 4000 as a DRP. Moreover, the effects of PEG 4000 were more pronounced in the tail arterial bed from SHR compared to Wistar rats. In conclusion, these data demonstrated for the first time that PEG 4000 was more effective in reducing the pressure-flow response as well as WSS in the tail arterial bed of hypertensive than of normotensive rats and these effects were amplified by, but not dependent on, endothelial integrity. Thus, these results show an additional mechanism of action of this polymer besides its mechanical effect through the release and/or bioavailability of endothelial factors.
Resumo:
This thesis addresses the coolability of porous debris beds in the context of severe accident management of nuclear power reactors. In a hypothetical severe accident at a Nordic-type boiling water reactor, the lower drywell of the containment is flooded, for the purpose of cooling the core melt discharged from the reactor pressure vessel in a water pool. The melt is fragmented and solidified in the pool, ultimately forming a porous debris bed that generates decay heat. The properties of the bed determine the limiting value for the heat flux that can be removed from the debris to the surrounding water without the risk of re-melting. The coolability of porous debris beds has been investigated experimentally by measuring the dryout power in electrically heated test beds that have different geometries. The geometries represent the debris bed shapes that may form in an accident scenario. The focus is especially on heap-like, realistic geometries which facilitate the multi-dimensional infiltration (flooding) of coolant into the bed. Spherical and irregular particles have been used to simulate the debris. The experiments have been modeled using 2D and 3D simulation codes applicable to fluid flow and heat transfer in porous media. Based on the experimental and simulation results, an interpretation of the dryout behavior in complex debris bed geometries is presented, and the validity of the codes and models for dryout predictions is evaluated. According to the experimental and simulation results, the coolability of the debris bed depends on both the flooding mode and the height of the bed. In the experiments, it was found that multi-dimensional flooding increases the dryout heat flux and coolability in a heap-shaped debris bed by 47–58% compared to the dryout heat flux of a classical, top-flooded bed of the same height. However, heap-like beds are higher than flat, top-flooded beds, which results in the formation of larger steam flux at the top of the bed. This counteracts the effect of the multi-dimensional flooding. Based on the measured dryout heat fluxes, the maximum height of a heap-like bed can only be about 1.5 times the height of a top-flooded, cylindrical bed in order to preserve the direct benefit from the multi-dimensional flooding. In addition, studies were conducted to evaluate the hydrodynamically representative effective particle diameter, which is applied in simulation models to describe debris beds that consist of irregular particles with considerable size variation. The results suggest that the effective diameter is small, closest to the mean diameter based on the number or length of particles.
Resumo:
BACKGROUND: A packed bed bioreactor (PBBR) activated with an indigenous nitrifying bacterial consortia was developed and commercialized for rapid establishment of nitrification in brackish water and marine hatchery systems in the tropics. The present study evaluated nitrification in PBBR integrated into a Penaeus monodon recirculating maturation system under different substrate concentrations and flow rates. RESULTS:Instantnitrificationwasobservedafter integration ofPBBRinto thematuration system.TANandNO2-Nconcentrations were always maintained below0.5 mg L−1 during operation. The TANandNO2-N removalwas significant (P < 0.001) in all the six reactor compartments of the PBBR having the substrates at initial concentrations of 2, 5 and 10 mg L−1. The average volumetric TAN removal rates increased with flow rates from 43.51 (250 L h−1) to 130.44 (2500 L h−1) gTAN m−3 day−1 (P < 0.05). FISH analysis of the biofilms after 70 days of operation gave positive results with probes NSO 190 ((β ammonia oxidizers), NsV 443 (Nitrosospira spp.) NEU (halophilic Nitrosomonas), Ntspa 712 (Phylum Nitrospira) indicating stability of the consortia. CONCLUSION: The PBBR integrated into the P. monodon maturation system exhibited significant nitrification upon operation for 70 days as well as at different substrate concentrations and flow rates. This system can easily be integrated into marine and brackish water aquaculture systems, to establish instantaneous nitrification
Resumo:
The stability of stationary flow of a two-dimensional ice sheet is studied when the ice obeys a power flow law (Glen's flow law). The mass accumulation rate at the top is assumed to depend on elevation and span and the bed supporting the ice sheet consists of an elastic layer lying on a rigid surface. The normal perturbation of the free surface of the ice sheet is a singular eigenvalue problem. The singularity of the perturbation at the front of the ice sheet is considered using matched asymptotic expansions, and the eigenvalue problem is seen to reduce to that with fixed ice front. Numerical solution of the perturbation eigenvalue problem shows that the dependence of accumulation rate on elevation permits the existence of unstable solutions when the equilibrium line is higher than the bed at the ice divide. Alternatively, when the equilibrium line is lower than the bed, there are only stable solutions. Softening of the bed, expressed through a decrease of its elastic modulus, has a stabilising effect on the ice sheet.
Resumo:
This study aimed at evaluating the effect of increasing organic loading rates and of enzyme pretreatment on the stability and efficiency of a hybrid upflow anaerobic sludge blanket reactor (UASBh) treating dairy effluent. The UASBh was submitted to the following average organic loading rates (OLR) 0.98 Kg.m(-3).d(-1), 4.58 Kg.m(-3).d(-1), 8.89 Kg.m(-3).d(-1) and 15.73 Kg.m(-3).d(-1), and with the higher value, the reactor was fed with effluent with and without an enzymatic pretreatment to hydrolyze fats. The hydraulic detention time was 24 h, and the temperature was 30 +/- 2 degrees C. The reactor was equipped with a superior foam bed and showed good efficiency and stability until an OLR of 8.89 Kg.m(-3).d(-1). The foam bed was efficient for solid retention and residual volatile acid concentration consumption. The enzymatic pretreatment did not contribute to the process stability, propitiating loss in both biomass and system efficiency. Specific methanogenic activity tests indicated the presence of inhibition after the sludge had been submitted to the pretreated effluent It was concluded that continuous exposure to the hydrolysis products or to the enzyme caused a dramatic drop in the efficiency and stability of the process, and the single exposure of the biomass to this condition did not inhibit methane formation. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
In the last decade, biological purification of gaseous waste has become an important alternative to many conventional methods of exhaust air treatment. More recently, biofiltration has proved to be an effective and inexpensive method for the treatment of air contaminated with volatile organic compounds (VOCs). A biofilter consists in a reactor packed with a porous solid bed material, where the microorganisms are fixed. During the biofiltration process, polluted air is transported through the biofilter medium where the contaminant is degraded. Within the biofilm, the pollutants in the waste gases are energy and carbon sources for microbial metabolism and are transformed into CO2, water and biomass. The bed material should be characterized by satisfactory mechanical and physical properties as structure, void fraction, specific area and flow resistance. The aim of this research was the biofilter construction and study of the biological degradation of ethanol and toluene, as well as the modeling of the process. Luffa cylindrica is a brazilian fiber that was used as the filtering material of the present work. The parameters and conditions studied were: composition of nutrients solution; effect of microflorae strains, namely Pseudomanas putida and Rhodococcus rhodochrous; waste gas composition; air flow rate; and inlet load of VOCs. The biofilter operated in diffusion regime and the best results for remotion capacity were obtained when a microorganisms consortion of Pseudomanas putida and Rhodococcus rhodochrous,were used, with a gas flow rate of 1 m3.h-1 and molar ratio nitrogene/phosphore N/P=2 in the nutrients solution. The maximum remotion capacity for ethanol was around 90 g.m-3.h-1 and 50 g.m-3.h-1 to toluene. It was proved that toluene has inhibitory effect on the ethanol remotion When the two VOCs were present in the same waste gas, there was a decrease of 40% in ethanol remotion capacity. Luffa cylindrica does not present considerable pressure drop. Ottengraf and van Lith models were used to represent the results obtained for ethanol and toluene, respectively. The application of the transient model indicated a satisfactory approximation between the experimental results obtained for ethanol and toluene vapors biofiltration and the ones predicted it
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work aims to study the thermodynamic, ecological and fluid-dynamic aspects of a circulating fluidized bed gasifier using sugar cane bagasse as biomass, in order to estimate a model of its normal operation. In the initial stage was analysed the composition of biomass selected (sugar cane bagasse) and its lower heating value (LHV) was calculated. The energy balance of the gasifier was done, being the volumetric flow of air, synthesis gas and biomass estimated. Also the power produced by this gasifier was theoretically estimated. Then the circulating fluidized bed gasifier was designed for operation with approximately 100 kg/h of processed biomass. Cross-sectional area of the reactor, feeder size, diameter of the exit zone of the gases and minimum height of the expanded bed were selected. Some bed gasifier hydrodynamic factors were also studied. The minimum fluidization velocity, fluidization terminal velocity, and average fluidizing velocity were calculated, in order to understand the fluid-dynamic behaviour of gasification of this fuel. It was obtained a theoretical model that can support a possible prototype of circulating fluidized bed gasifier biomass. Finally, there were studied the ecological aspects of the gasifier, through an overall methodology. Ecological efficiencies were estimated for two scenarios: first considering the carbon cycle and thereafter disregarding the carbon cycle. In both cases, it can be proved the ecological viability of the project. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study aimed to develop, implement and evaluate the performance of a new type of bioreactor for anaerobic treatment of wastewater using different filling materials like trickling filters post-reactor. This bioreactor has mixed characteristics of the UASB reactors and horizontal flow from the point of view of removal of BOD (Biochemical Oxygen Demand) ssed (settled solids), TS (Total Solids), SS (Suspended Solid), SD (Dissolved Solids) and turbidity. The experimental model consists of a bioreactor with a volume of 12 m³, 2/3 filled by fluidized bed and 1/3 for fixed. The fluidized bed is made of polystyrene plates used as a system percolation and compartmentalized trickling filters, where each compartment was filled with a support medium with different characteristics (gravel number 4, plastic rings of polystyrene, PET and HDPE) . In addition, the output of a filter system was installed three entries filled with activated carbon. The bioreactor was installed in private residence in the city of Igarapava-SP (20° 02'40.18"S and 47° 45'01.36" W). The system was highly efficient as the removal of organic contaminant load 92% on average reducing the BOD, a significant result when compared to other anaerobic systems. For the other parameters, the mean reduction was 96% for turbidity, 99% ssed, 67.5% ST, 57% SD and 88% of SS. As for its operation the system was capable of operating in continuous flow without the need for maintenance during the entire period of evaluation and without energy, as it operates taking advantage of the natural slope of the terrain where it is installed. The environmental impacts were minimized due to the preservation of local vegetation allowing the ecosystem to remain unchanged beyond the prototype was completely sealed preventing exhalation of odors and therefore not causing inconvenience to neighboring populations. Given these facts it was concluded that the prototype is shown to be highly feasible deployed as a new alternative for treatment of sewage in rural and urban settings (individual homes, condos, farms, ranches, etc.) Due to ease of design and operability, and sustainability at all stages of execution.
Resumo:
Batch combustion of fixed beds of coal, bagasse and blends thereof took place in a pre-heated two-stage electric laboratory furnace, under high-heating rates. The average input fuel/air equivalence ratios were similar for all fuels. The primary and secondary furnace temperatures were varied from 800 degrees C to 1000 degrees C. The effects of fuel blending, combustion staging, and operating furnace temperatures on the emissions from the two fuels were assessed. Furnace effluents were analyzed for carbon dioxide and for products of incomplete combustion (PIC) including CO, volatile and semi-volatile hydrocarbons, as well as particulate matter. Results showed that whereas CO2 was generated during both the observed sequential volatile matter and char combustion phases of the fuels, PICs were only generated during the volatile matter combustion phase. CO2 emissions were the highest from coal, whereas CO and other PIC emissions were the highest from bagasse. Under this particular combustion configuration, combustion of the volatile matter of the blends resulted in lower yields of PIC, than combustion of the volatiles of the neat fuels. Though CO and unburned hydrocarbons from coal as well as from the blends did not exhibit a clear trend with furnace temperature, such emissions from bagasse clearly increased with temperature. The presence of the secondary furnace (afterburner) typically reduced PIC, by promoting further oxidation of the primary furnace effluents. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
O processo MBBR/IFAS, Moving Bed Biofilm Reactor/Integrated Fixed Film Activated Sludge, é uma tecnologia recente para o tratamento de esgoto que incorpora tanto biomassa em suspensão como aderida. Seus parâmetros de controle são os mesmos aplicados ao processo de lodo ativado, observadas algumas especificidades. Como objetivo principal deste trabalho, apresenta-se uma análise comparativa entre os custos de implantação de uma unidade IFAS e de lodo ativado operando sob alta taxa, na faixa convencional e com aeração prolongada, para populações de 50.000 e 500.000 habitantes. Os resultados mostraram que, sob as hipóteses assumidas para a implantação dos reatores, o custo do processo de lodo ativado foi de 36% até 100% do custo do processo IFAS, dependendo da carga orgânica aplicada, do preço do terreno ou do custo do meio suporte.
Resumo:
Le acque di vegetazione (AV) costituiscono un serio problema di carattere ambientale, sia a causa della loro elevata produzione sia per l’ elevato contenuto di COD che oscilla fra 50 e 150 g/l. Le AV sono considerate un refluo a tasso inquinante fra i più elevati nell’ambito dell’industria agroalimentare e la loro tossicità è determinata in massima parte dalla componente fenolica. Il presente lavoro si propone di studiare e ottimizzare un processo non solo di smaltimento di tale refluo ma anche di una sua valorizzazione, utlizzandolo come materia prima per la produzione di acidi grassi e quindi di PHA, polimeri biodegradabili utilizzabili in varie applicazioni. A tale scopo sono stati utilizzati due bioreattori anaerobici a biomassa adesa, di identica configurazione, con cui si sono condotti due esperimenti in continuo a diverse temperature e carichi organici al fine di studiare l’influenza di tali parametri sul processo. Il primo esperimento è stato condotto a 35°C e carico organico pari a 12,39 g/Ld, il secondo a 25°C e carico organico pari a 8,40 g/Ld. Si è scelto di allestire e mettere in opera un processo a cellule immobilizzate in quanto questa tecnologia si è rivelata vantaggiosa nel trattamento continuo di reflui ad alto contenuto di COD e carichi variabili. Inoltre si è scelto di lavorare in continuo poiché tale condizione, per debiti tempi di ritenzione idraulica, consente di minimizzare la metanogenesi, mediata da microrganismi con basse velocità specifiche di crescita. Per costituire il letto fisso dei due reattori si sono utilizzati due diversi tipi di supporto, in modo da poter studiare anche l’influenza di tale parametro, in particolare si è fatto uso di carbone attivo granulare (GAC) e filtri ceramici Vukopor S10 (VS). Confrontando i risultati si è visto che la massima quantità di VFA prodotta nell’ambito del presente studio si ha nel VS mantenuto a 25°C: in tale condizione si arriva infatti ad un valore di VFA prodotti pari a 524,668 mgCOD/L. Inoltre l’effluente in uscita risulta più concentrato in termini di VFA rispetto a quello in entrata: nell’alimentazione la percentuale di materiale organico presente sottoforma di acidi grassi volatili era del 54 % e tale percentuale, in uscita dai reattori, ha raggiunto il 59 %. Il VS25 rappresenta anche la condizione in cui il COD degradato si è trasformato in percentuale minore a metano (2,35 %) e questo a prova del fatto che l’acidogenesi ha prevalso sulla metanogenesi. Anche nella condizione più favorevole alla produzione di VFA però, si è riusciti ad ottenere una loro concentrazione in uscita (3,43 g/L) inferiore rispetto a quella di tentativo (8,5 g/L di VFA) per il processo di produzione di PHA, sviluppato da un gruppo di ricerca dell’università “La Sapienza” di Roma, relativa ad un medium sintetico. Si può constatare che la modesta produzione di VFA non è dovuta all’eccessiva degradazione del COD, essendo questa nel VS25 appena pari al 6,23%, ma piuttosto è dovuta a una scarsa concentrazione di VFA in uscita. Questo è di buon auspicio nell’ottica di ottimizzare il processo migliorandone le prestazioni, poiché è possibile aumentare tale concentrazione aumentando la conversione di COD in VFA che nel VS25 è pari a solo 5,87%. Per aumentare tale valore si può agire su vari parametri, quali la temperatura e il carico organico. Si è visto che il processo di acidogenesi è favorito, per il VS, per basse temperature e alti carichi organici. Per quanto riguarda il reattore impaccato con carbone attivo la produzione di VFA è molto ridotta per tutti i valori di temperatura e carichi organici utilizzati. Si può quindi pensare a un’applicazione diversa di tale tipo di reattore, ad esempio per la produzione di metano e quindi di energia.
Resumo:
En este trabajo se llevó a cabo el tratamiento de vinazas mediante dos tecnologías anaerobias. Se dividió en cuatro estudios técnicos. El primero fue el arranque y estabilización del reactor UASB (Upflow Anaerobic Sludge Blanket), en dónde se evaluó la estabilización mediante la eficiencia de remoción de DQO y la granulación del lodo. El segundo estudio evaluó el rendimiento del reactor UASB frente a diferentes Cva. El tercer estudio evaluó el efecto del TRH sobre la eficiencia del reactor UASB, y el cuarto de ellos fue evaluar el rendimiento del RABF (Reactor Anaerobio de Biomasa Fija). El reactor UASB de 2,6 L de capacidad, fue arrancado por lotes, con seis ensayos utilizando vinaza como sustrato. Se obtuvieron eficiencias de remoción en DQO en un rango de 79-91%, en los seis lotes. Se obtuvo formación de gránulos con diámetro (Ø) de 0,85-1,15 mm y un coeficiente de esfericidad (Є) de 0,7-0,77. Se logró la granulación de lodos tras 2 meses de operación. Alcanzada la estabilización del reactor UASB, se siguió una operación en flujo continuo. Las Cva probadas de 1, 2, 4 y 6 gDQO/L.d para el reactor UASB dan una respuesta bastante favorable con respecto al rendimiento del reactor, ya que presento eficiencias de remoción de DQOs del 51 hasta el 76%, eficiencias similares a los reportados por la literatura. En el estudio de TRH se operó con Cva de 6 gDQO/L.d y los TRH fueron de 24, 12 ,5 ,3 y 1 día. El % de eliminación de DQO fue de 51, 60, 57, 60 y 63 % remoción en DQOsoluble, respectivamente. Se alcanzó una producción de biogás máximo de 5.283 ml/d, pero al reducir el TRH se observó una reducción proporcional del volumen total de biogás. El %CH4 contenido en el biogás aumento al disminuir el TRH, reflejando valores de 80 al 92 % de CH4. El RABF con un volumen de 8,2 L, utilizo tubos de plástico corrugado como medio de soporte para las bacterias. Se aplicaron las siguientes Cva; 0,5, 1, 3 y 6 gDQO/L.d. El reactor RABF presento una excelente remoción de la materia orgánica (80% DQOs), una producción de biogás estable, y un contenido en CH4 del biogás muy interesante. Sin embargo, para una Cva superior a 3 gDQO/L.d empezó un comportamiento inesperado de reducción de capacidad. Las condiciones hidrodinámicas del reactor UASB son decisivas para la formación de los gránulos, condición previa para iniciar el flujo continuo. Al operar el reactor UASB en modo continuo, se pudo evaluar las mejores condiciones de operación para este tipo de residuo (vinaza). La Cva de 6 gDQO/L.d para el reactor UASB alimentado con vinaza bruta representa el límite de su capacidad. Sin embargo, al aumentar la Cva se genera una mayor producción de biogás y metano. La eficiencia de remoción de la DQO soluble es independiente del TRH, para una Cva de 6 g DQO/L•d y las condiciones de TRH probadas (24, 12, 5, 3 y 1 días). Los valores de remoción de DQO alcanzados son un poco superior a los valores de biodegradabilidad anaerobia de la vinaza observados de 50 %. De manera general, la reducción del TRH o bien la dilución de la vinaza no presenta un efecto significativo sobre la remoción de la materia orgánica soluble, pero si lo presenta en la remoción de sulfatos reduciendo indirectamente su toxicidad. El soporte termoplástico inoculado en el RABF y alimentado con vinaza bruta, actuó como un filtro, además de obtener buenos resultados en eliminación de DQO, pero dada las dimensiones y la altura del relleno se frena la evacuación del metano. This work was carried out by treatment vinasses with two anaerobic technologies. It was divided into four technical studies. The first was the start up and stabilization Upflow Anaerobic Sludge Blanket (UASB) reactor, where the stability was evaluated by the removal efficiency of COD and sludge granulation. The second study evaluated the performance of the UASB reactor against different OLR. The third study evaluated the effect of HRT on the efficiency of the UASB reactor, and the fourth of which was evaluate the performance Fixed Biomass Anaerobic (FBA) reactor. The UASB reactor of 2,6 L capacity, was started in batch, with six assays using vinasse as substrate. Were obtained removal efficiencies of COD in the range of 79- 91% in the six batches. Forming granules were obtained with a diameter (Ø) of 0,85- 1,15 mm and sphericity coefficient (Є) of 0,7 to 0,77. Sludge granulation was achieved after 2 months of operation. Once stabilization is achieved of the UASB reactor, it was followed by a continuous flow operation. The OLR tested 1, 2, 4 and 6 gCOD/L.d for UASB reactor gives a very favorable response regarding the performance of the reactor, as presented COD5 removal efficiencies of 51 to 76%, similar efficiencies those reported in the literature The HRT study was operated with an OLR of 6 gCOD/L.d and HRT were 24, 12, 5, 3 and 1 day. The removal efficiency was 51, 60, 57, 60 and 63% in soluble COD, respectively. It reached a maximum biogas production of 5.283 ml / d, but by reducing the HRT showed a proportional reduction in the total volume of biogas. The %CH4 content in the biogas increased with decreasing TRH, reflecting values of 80 to 92% of CH4. The FBA reactor with a volume of 8,2 L, used corrugated plastic tubes as carrier for bacteria transportation. The following OLR was applied, 0,5, 1, 3 and 6 gCOD/L.d. The FBA reactor showed an excellent removal of organic matter (80% CODS), a stable biogas production, and CH4 content very interesting. However, for more than 3 gCOD/L.d OLR began with unexpected behavior of capacity reduction. The UASB reactor hydrodynamic conditions are decisive for the formation of the granules, precondition to start the continuous flow. By operating the UASB reactor in continuous mode, it was possible to evaluate the best operating conditions for this type of waste (vinasse). The OLR of 6 gCOD/L.d for the UASB reactor fed with raw vinasse represents the limit of its capacity. However, with increasing OLR creates increased biogas production and methane. The removal efficiency of soluble COD is independent of HRT for OLR of 6 gCOD/L.d and HRT conditions tested (24, 12, 5, 3 and 1 day). COD Removal values achieved are slightly higher than the values of the vinasse anaerobic biodegradability of observed at 50%. Generally, reduction of HRT or vinasse dilution does not present a significant effect on the removal of the soluble organic matter; however if it occurs in the removal of sulfate reducing indirectly its toxicity. The thermoplastic support inoculated in FBA reactor and fed with raw vinasse, acted as a filter, in addition to obtaining good results in COD removal, but given the size and height of the filling slows evacuation of methane.