991 resultados para Elevated plus maze test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction and Purpose: Bimatoprost and the fixed combination of latanoprost with timolol maleate are 2 medications widely used to treat glaucoma and ocular hypertension (OHT). The aim of the study is to compare the efficacy of these 2 drugs in reducing intraocular pressure (IOP) after 8 weeks of treatment in patients with primary open angle glaucoma (POAG) or OHT. Methods: In this randomized, open-label trial, 44 patients with POAG or OHT were allocated to receive either bimatoprost (1 drop QD) or latanoprost/timolol (1 drop QD). Primary outcome was the mean diurnal IOP measurement at the 8th week, calculated as the mean IOP measurements taken at 8:00 AM, 10: 00 AM, and 12: 00 PM Secondary outcomes included the baseline change in IOP measured 3 times a day, after the water-drinking test (performed after the last IOP measurement), and the assessment of side effects of each therapy. Results: The mean IOP levels of latanoprost/timolol (13.83, SD = 2.54) was significantly lower than of bimatoprost (16.16, SD = 3.28; P < 0.0001) at week 8. Also, the change in mean IOP values was significantly higher in the latanoprost/timolol group at 10:00 AM (P = 0.013) and 12:00 PM (P = 0.01), but not at 8: 00 AM (P = ns). During the water-drinking test, there was no signifi cant difference in IOP increase (absolute and percentage) between groups; however, there was a signifi cant decrease in mean heart rate in the latanoprost/timolol group. Finally, no signifi cant changes in blood pressure and lung spirometry were observed in either groups. Conclusions: The fixed combination of latanoprost/timolol was significantly superior to bimatoprost alone in reducing IOP in patients with POAG or OHT. Further studies with large sample sizes should be taken to support the superior efficacy of latanoprost/timolol, as well as to better assess its profile of side effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the first measurements of identified hadron production, azimuthal anisotropy, and pion interferometry from Au + Au collisions below the nominal injection energy at the BNL Relativistic Heavy-Ion Collider (RHIC) facility. The data were collected using the large acceptance solenoidal tracker at RHIC (STAR) detector at root s(NN) = 9.2 GeV from a test run of the collider in the year 2008. Midrapidity results on multiplicity density dN/dy in rapidity y, average transverse momentum < p(T)>, particle ratios, elliptic flow, and Hanbury-Brown-Twiss (HBT) radii are consistent with the corresponding results at similar root s(NN) from fixed-target experiments. Directed flow measurements are presented for both midrapidity and forward-rapidity regions. Furthermore the collision centrality dependence of identified particle dN/dy, < p(T)>, and particle ratios are discussed. These results also demonstrate that the capabilities of the STAR detector, although optimized for root s(NN) = 200 GeV, are suitable for the proposed QCD critical-point search and exploration of the QCD phase diagram at RHIC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on solvation studies of polymers, the sum (1: 1) of the electron acceptor (AN) and electron donor (DN) values of solvents has been proposed as an alternative polarity scale. To test this, the electron paramagnetic resonance isotropic hyperfine splitting constant, a parameter known to be dependent on the polarity/proticity of the medium, was correlated with the (AN+DN) term using three paramagnetic probes. The linear regression coefficient calculated for 15 different solvents was approximately 0.9, quite similar to those of other well-known polarity parameters, attesting to the validity of the (AN+DN) term as a novel ""two-parameter"" solvent polarity scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the additive effect of dorzolamide/timolol fixed combination in patients under monotherapy with latanoprost. Patients and Methods: In this prospective, 4-week, randomized, open-label controlled clinical trial, patients with open-angle glaucoma or ocular hypertension, which presented at least 15% intraocular pressure (IOP) reduction after a minimum period of 15 days of monotherapy with latanoprost and whose IOP level was considered above the established target-IOP level were randomized to receive fixed combination of timolol/dorzolamide twice daily in one of eyes. The fellow eye was kept under monotherapy and was included in the control group. A modified diurnal tension curve (mDTC) followed by the water drinking test were performed in the baseline and week 4 visits to evaluate IOP profile between groups. Results: Forty-nine per-protocol patients were analyzed. After latanoprost monotherapy run-in period, IOP levels were significantly reduced (P<0.001) in both control and study groups to 15.34 +/- 2.96 mm Hg and 15.24 +/- 2.84 mm Hg (30.8% and 32.2% IOP reduction, respectively; P=0.552). At week 4, mean baseline diurnal IOP levels were 15.60 +/- 3.09 and 14.44 +/- 3.03 (7.4% difference; P=0.01). Mean baseline IOP modified diurnal tension curve peak after latanoprost run-in period were 17.47 +/- 3.68 mm Hg and 17.02 +/- 3.35 mm Hg (control and study eyes, respectively; P=0.530). At week 4 visit, mean water-drinking test peaks were significantly reduced in the study eye group in comparison with the control group: 19.02 +/- 3.81 mm Hg and 20.39 +/- 4.19 mm Hg, respectively (6.7% reduction; P=0.039). Conclusions: In our sample, dorzolamide 2%/timolol 0.5% fixed combination as add-on therapy in patients with open-angle glaucoma or ocular hypertension under monotherapy with latanoprost with IOP already in mid-teens levels may further enhance pressure reduction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare the efficacy and tolerability of the fixed combination of timolol maleate 0.5%/brimonidine tartrate 0.2% versus fixed combination of timolol maleate 0.5%/dorzolamide 2% in patients with elevated intraocular pressure (IOP) over 8 weeks. Patients and Methods: This 8-week, multicentric. interventional, randomized, open-label, parallel group study was conducted Lit 4 centers in Brazil and 1 center in Argentina. Patients with open-angle glaucoma or ocular hypertension were randomized to receive bilaterally fixed combination of brimonidine/timolol maleate 0.5% or fixed combination of dorzolamide 2%/timolol 0.5% twice daily at 8:00 AM and 8:00 PM. A modified diurnal tension curve (8:00 AM 10:30 AM, 02:00 PM, and 4:00 PM) followed by the water drinking test (WDT), which estimates IOP peak of diurnal tension curve, were performed in the baseline and week-8 visits. Adverse events data were recorded at each visit. Results: A total of 210 patients were randomized (brimonidine/timolol, n = 111; dorzolamide/timolol, n = 99). Mean baseline IOP was 23.43 +/- 3.22 mm Hg and 23.43 +/- 4.06 mm Hg in the patients treated with brimonidine/timolol and dorzolamide/timolol, respectively (P = 0.993). Mean diurnal IOP reduction after 8 weeks were 7.02 +/- 3.06 mm Hg and 6.91 +/- 3.67 mm Hg. respectively (P = 0.811). The adjusted difference between groups (analysis of covariance) Lit week 8 was not statistically significant (P = 0.847). Mean baseline WDT peak was 27.79 +/- 4.29 mm Hg in the brimonidine/timolol group and 27.68 +/- 5.46 mm Hg in the dorzolamide/timolol group. After 8 weeks of treatment, mean WDT peaks were 20.94 +/- 3.76 mm Hg (P < 0.001) and 20.98 +/- 4.19 (P < 0.001), respectively. The adjusted difference between groups (analysis of covariance) was not statistically significant (P = 0.469). No statistical difference in terms of adverse events was Found between groups. Conclusions: Both fixed combinations were capable of significantly reducing the mean diurnal IOP, mean diurnal peak, and mean WDT peak after 8 weeks of treatment. Also, both fixed combinations are well tolerated with few side effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the flow rate of 3 endodontic sealers: Sealer 26, AH Plus, and MTA Obtura. Study design. According to the method proposed by the American Dental Association (ADA specification no. 57), the sealers were placed between 2 glass slabs under a weight of 120 g. The diameters of the formed discs were measured with a digital paquimeter. The test was repeated 5 times for each sealer. Results. The results were expressed as arithmetic means, and the statistical analysis was performed through Tukey test. AH Plus showed significantly superior flow rate compared with Sealer 26 and MTA Obtura. There was no statistically significant difference between flow rates presented by Sealer 26 and MTA Obtura. Conclusion. Within the limitations of this in vitro study, it was concluded that all of the the endodontic sealers tested presented greater flow than the minimum recommended in the ADA 57 specification. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;109:e47-e49)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>Aim To assess the physicochemical properties and the surface morphology of AH Plus, Epiphany, and Epiphany SE root canal sealers. Methodology Five samples of each material were employed for each test according to ANSI/ADA specification 57. The samples were assigned to four groups: (i) AH Plus; (ii) Epiphany; (iii) Epiphany + Thinning Resin; (iv) Epiphany SE. The distilled water used during the solubility test was submitted to spectrometry to verify the release of calcium ions. The morphologies of the external surface and the cross-section of the samples were analysed by means of a scanning electron microscope (SEM). Statistical analysis was performed by using One-Way anova and post hoc Tukey-Kramer tests with the null hypothesis set as 5%. Results Setting time, flow and radiopacity results were in accordance with ANSI/ADA requirements whereas the dimensional change of all sealers and solubility of Epiphany did not fulfil ANSI/ADA protocols. AH Plus and Epiphany SE were similar in terms of flow, radiopacity, solubility and dimensional change. The spectrometry test revealed significant calcium ion release from Epiphany with and without the thinning resin. SEM analysis revealed essentially a homogeneous surface with compact layer and some rough areas. Conclusions Setting time, flow, and radiopacity tests conformed to ANSI/ADA standardization. The dimensional change in all groups and the solubility of Epiphany were greater than values considered acceptable, with higher amounts of calcium ion release. Epiphany SE revealed more organized, compacted, and homogeneous polymers in a reduced resin matrix when compared with the other groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To evaluate the bond strength of AH Plus and Epiphany sealers to human root canal dentine irradiated with a 980 nm diode laser at different power and frequency parameters, using the push-out test. Methodology Sixty canine roots were sectioned below the cementoenamel junction to provide 4-mm-thick dentine discs that had their root canals prepared with a tapered bur and irrigated with sodium hypochlorite, ethylenediaminetetraacetic acid and distilled water. The specimens were assigned to five groups (n = 12): one control (no laser) and four experimental groups that were submitted to 980 nm diode laser irradiation at different power (1.5 and 3.0 W) and frequency (continuous wave and 100 Hz) parameters. Half of specimens in each group had their canals filled with AH Plus sealer and half with Epiphany. The push-out test was performed and data (MPa) were analysed statistically by ANOVA and Tukey`s test (P < 0.05). The specimens were split longitudinally and examined under SEM to assess the failure modes after sealer displacement. Results The specimens irradiated with the diode laser and filled with AH Plus had significantly higher bond strength values (8.69 +/- 2.44) than those irradiated and filled with Epiphany (3.28 +/- 1.58) and the nonirradiated controls (3.86 +/- 0.60). The specimens filled with Epiphany did not differ significantly to each other or to the control (1.75 +/- 0.69). There was a predominance of adhesive failures at Epiphany-dentine interface (77%) and mixed failures at AH Plus-dentine interface (67%). Conclusions The 980 nm diode laser irradiation of root canal dentine increased the bond strength of AH Plus sealer, but did not affect the adhesion of Epiphany sealer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le test ELISA-TÉTANOS (Biosys, France) a été utilisé pour le titrage des anti-corps tétaniques (sensibilité = 0,0025 UI/ml) en sérums humains de donneurs de sang, 566 hommes et 108 femmes, âges de 18 à 58 ans, moyenne de 29 ans, provenant de São Paulo, SP, Brésil. L'OMS, acceptant seulement la séroneutralisation sur souris (NT), la méthode de référence, pour les études sur la protection contre le tétanos, préconise le titre de 0,01 UI/ml comme minimum protecteur. BOURLEAUD & HUET ont proposé la limite de 0,06 UI/ml quand s'emploie le test ELISA, en attendant à une certaine discordance inévitable entre les méthodes. Parmi les 674 sérums étudiés, 178 (26,41%) n'ont pas présenté d'anticorps (< 0,0025 UI/ml); 413 (61,28%) ont présenté des résultats égaux ou supérieurs à 0,01 UI/ml et en 232 (34,42%) les titres ont été égaux ou supérieurs à 0,06 UI/ml. Le pourcentage d'individus protégés a été inversement proportionnel à 1'âge: environ 50% dans le groupe le plus jeune (hommes de 18 à 35 ans et femmes de 18 à 23 ans) contre environ 10% dans le groupe de plus de 42 ans ont présenté des titres sûrement protecteurs (> 0,06 UI/ml).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The diagnosis of dengue and the differentiation between primary and secondary infections are important for monitoring the spread of the epidemic and identifying the risk of severe forms of the disease. The detection of immunoglobulin (Ig)M and IgG antibodies is the main technique for the laboratory diagnosis of dengue. The present study assessed the application of a rapid test for dengue concerning detection of new cases, reinfection recognition, and estimation of the epidemic attack rate. METHODS: This was a retrospective, cross-sectional, descriptive study on dengue using the Fortaleza Health Municipal Department database. The results from 1,530 tested samples, from 2005-2006, were compared with data from epidemiological studies of dengue outbreaks in 1996, 2003, and 2010. RESULTS: The rapid test confirmed 52% recent infections in the tested patients with clinical suspicion of dengue: 40% detected using IgM and 12% of new cases using IgG in the non-reactive IgM results. The positive IgM plus negative IgG (IgM+ plus IgG-) results showed that 38% of those patients had a recent primary dengue infection, while the positive IgG plus either positive or negative IgM (IgG+ plus IgM+/-) results indicated that 62% had dengue for at least a second time (recent secondary infections). This proportion of reinfections permitted us to estimate the attack rate as >62% of the population sample. CONCLUSIONS: The rapid test for dengue has enhanced our ability to detect new infections and to characterize them into primary and secondary infections, permitting the estimation of the minimal attack rate for a population during an outbreak.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The objective was to describe the results of the injection of immotile spermatozoa with flexible tails when only immotile spermatozoa are present in the semen sample. METHODS: A retrospective study was conducted to analyze the procedure results for 10 couples who participated in our intracytoplasmic sperm injection program. The sperm tail was considered flexible when it moved up and down independently of the head movement, and it was considered inflexible when the movement occurred together (tail plus head). The fertilization and pregnancy rate were analyzed. RESULTS: The normal fertilization rate (presence of 2 pronuclei) was 30.3% (40/132), and the abnormal fertilization rate (presence of less than or more than 2 pronuclei) was 6.81% (9/132). A total of 52 embryos were obtained with 9 transfer procedures performed (pregnancy rate: 11.12%). CONCLUSIONS: The sperm tail flexibility test (STFT) is an easy and cost-effective way for selecting viable immotile spermatozoa and can be used as an alternative method for determining the viability of spermatozoa. This test seems to be a simple and risk-free method when compared to the swelling test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reinforcement mechanisms at the cross section level assured by fibres bridging the cracks in steel fibre reinforced self-compacting concrete (SFRSCC) can be significantly amplified at structural level when the SFRSCC is applied in structures with high support redundancy, such is the case of elevated slab systems. To evaluate the potentialities of SFRSCC as the fundamental material of elevated slab systems, a ¼ scale SFRSCC prototype of a residential building was designed, built and tested. The extensive experimental program includes material tests for characterizing the relevant properties of SFRSCC, as well as structural tests for assessing the performance of the prototype at serviceability and ultimate limit conditions. Three distinct approaches where adopted to derive the constitutive laws of the SFRSCC in tension that were used in finite element material nonlinear analysis to evaluate the reliability of these approaches in the prediction of the load carrying capacity of the prototype.