968 resultados para Counting


Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is still imperative to develop a parasitological technique highly sensitive for diagnosing schistosomiasis in epidemiological and individual surveys. A simple and cheap hatching device with a collecting container was manufactured and tested under experimental conditions. Twelve Kato-Katz slides were performed as golden standard for comparison. Quantitative results can be carried out by counting miracidia in a plate and parasite load can be calculated (miracidia/gram of feces). Statistically significant values were higher in the hatching test. More sensitive results, with statistical significance, were achieved using 1.5 g of feces (which corresponds to 36 Kato-Katz slides) than by using the Kato-Katz method. Advantages of this technique and its limitations are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To evaluate whether ki-67 labelling index (LI) has independent prognostic value for survival of patients with bladder urothelial tumours graded according to the 2004 World Health Organisation classification. Methods: Ki-67 LI was evaluated in 164 cases using the grid counting method. Non-invasive (stage Ta) tumours were: papilloma (n = 5), papillary urothelial neoplasia of low malignant potential (PUNLMP; n = 26), and low (LG; n = 34) or high grade (HG; n = 15) papillary urothelial carcinoma. Early invasive (stage T1) tumours were: LG (n = 58) and HG (n = 26) carcinoma. Statistical analysis included Fisher and x2 tests, and mean comparisons by ANOVA and t test. Univariate and multivariate survival analyses were performed according to the Kaplan–Meier method with log rank test and Cox’s proportional hazard method. Results: Mean ki-67 LI increased from papilloma to PUNLMP, LG, and HG in stage Ta (p,0.0001) and from LG to HG in stage T1 (p = 0.013) tumours. High tumour proliferation (.13%) was related to greater tumour size (p = 0.036), recurrence (p = 0.036), progression (p = 0.035), survival (p = 0.054), and high p53 accumulation (p = 0.015). Ki-67 LI and tumour size were independent predictors of disease free survival (DFS), but only ki-67 LI was related to progression free survival (PFS). Cancer specific overall survival (OS) was related to ki-67 LI, tumour size, and p27kip1 downregulation. Ki-67 LI was the main independent predictor of DFS (p = 0.0005), PFS (p = 0.0162), and cancer specific OS (p = 00195). Conclusion: Tumour proliferation measured by Ki-67 LI is related to tumour recurrence, stage progression, and is an independent predictor of DFS, PFS, and cancer specific OS in TaT1 bladder urothelial cell carcinoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Euphorbia plants grow in many gardens. Their milky latex is, however, a strong irritant which may induce various ocular lesions from keratoconjunctivitis to severe uveitis. HISTORY AND SIGNS: A 86-year-old woman developed a unilateral severe anterior chamber inflammation associated with descemtic folds after direct contact with sap of Euphorbia. Visual acuity was limited to counting fingers. Her eye was operated from filtering surgery ten years previously. The patient was closely followed to rule out the diagnosis of bacterial endophthalmitis. THERAPY AND OUTCOME: Symptoms progressively resolved after topical administration of 3 mg/mL ofloxacine and 1 % prednisolone acetate. CONCLUSIONS: Euphorbia sap toxicity may take different forms from keratoconjunctivitis to severe uveitis. Euphorbia sap-induced uveitis should be kept in mind when the patient has seen in contact with freshly cut plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a mode of nude mice bearing a human colon carcinoma xenograft, the biodistribution and tumor localization of metatetrahydroxyphenylchlorin (m-THPC) coupled to polyethylene glycol (PEG) were compared with those of the free form of this photosensitizer used in photodynamic therapy (PDT). At different times after i.v. injection of both forms of 125I-labeled photosensitizer, m-THPC-PEG gave on average a 2-fold higher tumor uptake than free m-THPC. In addition, at early times after injection, m-THPC-PEG showed a 2-fold longer blood circulating half-life and a 4-fold lower liver uptake than free m-THPC. The tumor to normal tissue ratios of radioactivity concentrations were always higher for m-THPC-PEG than for free m-THPC at any time point studied from 2 to 96 hr post-injection. Significant coefficients of correlation between direct fluorescence measurements and radioactivity counting were obtained within each organ tested. Fluorescence microscopy studies showed that m-THPC-PEG was preferentially localized near the tumor vessels, whereas m-THPC was more diffusely distributed inside the tumor tissue. To verify whether m-THPC-PEG conjugate remained phototoxic in vivo, PDT experiments were performed 72 hr after injection and showed that m-THPC-PEG was as potent as free m-THPC in the induction of tumor regression provided that the irradiation does for m-THPC-PEG conjugate was adapted to a well-tolerated 2-fold higher level. The overall results demonstrate first the possibility of improving the in vivo tumor localization of a hydrophobic dye used for PDT by coupling it to PEG and second that a photosensitizer conjugated to a macromolecule can remain phototoxic in vivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The haematological changes and release of soluble mediators, particularly C-reactive protein (CRP) and nitric oxide (NO), during uncomplicated malaria have not been well studied, especially in Brazilian areas in which the disease is endemic. Therefore, the present study examined these factors in acute (day 0) and convalescent phase (day 15) patients infected with Plasmodium falciparum and Plasmodium vivax malaria in the Brazilian Amazon. Haematologic parameters were measured using automated cell counting, CRP levels were measured with ELISA and NO plasma levels were measured by the Griess reaction. Our data indicate that individuals with uncomplicated P. vivax and P. falciparum infection presented similar inflammatory profiles with respect to white blood cells, with high band cell production and a considerable degree of thrombocytopaenia during the acute phase of infection. Higher CRP levels were detected in acute P. vivax infection than in acute P. falciparum infection, while higher NO was detected in patients with acute and convalescent P. falciparum infections. Although changes in these mediators cannot predict malaria infection, the haematological aspects associated with malaria infection, especially the roles of platelets and band cells, need to be investigated further.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mice infected with Schistosoma mansoni were treated with oxamniquine, praziquantel, artesunate at the pre-patent phase, aiming at observing schistogram alterations. Half of the animals were perfused five days post-treatment for counting and classification of immature worms, based on pre-established morphological criteria (schistogram); the remaining animals were evaluated 42 or 100 days after infection and perfusion of the portal-system was performed for collection and counting of adult worms and oogram. It was observed that oxamniquine and artesunate treatment administered at the pre-postural phase causes significant reduction in the number of immature and adult worms. However, there was little reduction with praziquantel when used at the dose of 400 mg/kg for treatments administered 14, 15, 21 or 23 days post-infection. Artesunate was responsible for significant alterations in development of young worms, as well as for a higher number of worms presenting intestinal damages. Immature adult worms were detected in mice treated with artesunate or oxamniquine at the pre-patent phase of infection and recovered by perfusion 100 days after infection. Schistogram proved to be a very useful tool for experimental evaluation of the activity of antischistosomal drugs and a good model to identify the most sensitive stages to drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the performances of a double focusing magnetic beta spectrometer. The energy resolution was measured using conversion peaks of Cs-137 and Ba-133 at 0.73% for 624 keV, and 1.33% for 124 keV. The counting efficiency as a function of the energy was estimated using a P-32 source and was used to correct the measured spectra of Cs-137. The result was compared with the theoretical spectrum and we found a good agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION According to genome wide association (GWA) studies as well as candidate gene approaches, Behçet's disease (BD) is associated with human leukocyte antigen (HLA)-A and HLA-B gene regions. The HLA-B51 has been consistently associated with the disease, but the role of other HLA class I molecules remains controversial. Recently, variants in non-HLA genes have also been associated with BD. The aims of this study were to further investigate the influence of the HLA region in BD and to explore the relationship with non-HLA genes recently described to be associated in other populations. METHODS This study included 304 BD patients and 313 ethnically matched controls. HLA-A and HLA-B low resolution typing was carried out by PCR-SSOP Luminex. Eleven tag single nucleotide polymorphisms (SNPs) located outside of the HLA-region, previously described associated with the disease in GWA studies and having a minor allele frequency in Caucasians greater than 0.15 were genotyped using TaqMan assays. Phenotypic and genotypic frequencies were estimated by direct counting and distributions were compared using the χ(2) test. RESULTS In addition to HLA-B*51, HLA-B*57 was found as a risk factor in BD, whereas, B*35 was found to be protective. Other HLA-A and B specificities were suggestive of association with the disease as risk (A*02 and A*24) or protective factors (A*03 and B*58). Regarding the non-HLA genes, the three SNPs located in IL23R and one of the SNPs in IL10 were found to be significantly associated with susceptibility to BD in our population. CONCLUSION Different HLA specificities are associated with Behçet's disease in addition to B*51. Other non-HLA genes, such as IL23R and IL-10, play a role in the susceptibility to the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El model actual de consum comporta el malbaratament de recursos, potenciant l’ús desmesurat de materials i productes no reutilitzables, convertint-los en residu. Aquesta generació creixent de residus comporta la necessitat de gestionar-los de manera eficient o impedir generar-los, per minimitzar els impactes ambientals i econòmics. En aquest projecte es pretén actuar en la prevenció de la generació de residus a Sitges, concretament en la promoció d’actuacions de prevenció de residus en esdeveniments. L’estudi analitza la situació actual del municipi en quant a prevenció de residus i, tenint en compte el tipus de residus generats en els esdeveniments, proposa mesures per reduir-los considerant el seu cost econòmic, comptabilitzant les despeses amb i sense l’aplicació de les mesures, i el benefici d’aquestes llarg termini.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exposure to fine particles and noise has been linked to cardiovascular diseases and elevated cardiovascular mortality affecting the worldwide population. Residence and/or work in proximity to emission sources as for example road traffic leads to an elevated exposure and a higher risk for adverse health effects. Highway maintenance workers spend most of their work time in traffic and are exposed regularly to particles and noise. The aims of this thesis were to provide a better understanding of the workers' mixed exposure to particles and noise and to assess cardiopulmonary short term health effects in relation to this exposure. Exposure and health data were collected in collaboration with 8 maintenance centers of the Swiss Road Maintenance Services located in the cantons Bern, Fribourg and Vaud in western Switzerland. Repeated measurements with 18 subjects were conducted during 50 non-consecutive work shifts between Mai 2010 and February 2012, equally distributed over all seasons. In the first part of this thesis we tested and validated measurements of ultrafine particles with a miniature diffusion size classifier (miniDiSC) - a novel particle counting device that was used for the exposure assessment during highway maintenance work. We found that particle numbers and average particle size measured by the miniDiSC were highly correlated with data from the P-TRAK, a condensation particle counter (CPC), as well as from a scanning mobility particle sizer (SMPS). However, the miniDiSC measured significantly more particles than the P-TRAK and significantly less than the SMPS in its full size range. Our data suggests that the instrument specific cutoffs were the main reason for the different particle counts. The first main objective of this thesis was to investigate the exposure of highway maintenance workers to air pollutants and noise, in relation to the different maintenance activities. We have seen that the workers are regularly exposed to high particle and noise levels. This was a consequence of close proximity to highway traffic and the use of motorized working equipment such as brush cutters, chain saws, generators and pneumatic hammers during which the highest exposure levels occurred. Although exposure to air pollutants were not critical if compared to occupational exposure limits, the elevated exposure to particles and noise may lead to a higher risk for cardiovascular diseases in this worker population. The second main objective was to investigate cardiopulmonary short-term health effects in relation to the particle and noise exposure during highway maintenance work. We observed a PM2.5 related increase of the acute-phase inflammation markers C-reactive protein and serum amyloid A and a decrease of TNFa. Heart rate variability increased as a consequence of particle as well as noise exposure. Increased high frequency power indicated a stronger parasympathetic influence on the heart. Elevated noise levels during recreational time, after work, were related to increased blood pressure. Our data confirmed that highway maintenance workers are exposed to elevated levels of particles and noise as compared to the average population. This exposure poses a cardiovascular health risk and it is therefore important to make efforts to better protect the workers health. The use of cleaner machines during maintenance work would be a major step to improve the workers' situation. Furthermore, regulatory policies with the aim of reducing combustion and non-combustion emissions from road traffic are important for the protection of workers in traffic environments and the entire population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this issue of Genes & Development, Revyakin and colleagues (pp. 1691-1702) measure the relation between individual RNA polymerase II transcription events and transcription factor assembly by counting RNA transcripts retained on the template DNA using single-molecule fluorescence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The future of elections seems to be electronic voting systems du to its advantatges over the traditional voting. Nowadays, there are some different paradigms to ensure the security and reliability of e-voting. This document is part of a wider project which presents an e-Voting platform based on elliptic curve cryptography. It uses an hybrid combination of two of the main e-Voting paradigms to guarantee privacy and security in the counting phase, these are precisely, the mixnets and the homomorphic protocols. This document is focused in the description of the system and the maths and programming needed to solve the homomorphic part of it. In later chapters, there is a comparison between a simple mixing system and our system proposal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.