922 resultados para standard letters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Quitting smoking is associated with weight gain, which may threaten motivation to engage or sustain a quit attempt. The pattern of weight gained by smokers treated according to smoking cessation guidelines has been poorly described. We aimed to determine the weight gained after smoking cessation and its predictors, by smokers receiving individual counseling and nicotine replacement therapies for smoking cessation. METHODS: We performed an ancillary analysis of a randomized controlled trial assessing moderate physical activity as an aid for smoking cessation in addition to standard treatment in sedentary adult smokers. We used mixed longitudinal models to describe the evolution of weight over time, thus allowing us to take every participant into account. We also fitted a model to assess the effect of smoking status and reported use of nicotine replacement therapy at each time point. We adjusted for intervention group, sex, age, nicotine dependence, and education. RESULTS: In the whole cohort, weight increased in the first 3 months, and stabilized afterwards. Mean 1-year weight gain was 3.3kg for women and 3.9kg for men (p = .002). Higher nicotine dependence and male sex were associated with more weight gained during abstinence. Age over median was associated with continuing weight gain during relapse. There was a nonsignificant trend toward slower weight gain with use of nicotine replacement therapies. CONCLUSION: Sedentary smokers receiving a standard smoking cessation intervention experience a moderate weight gain, limited to the first 3 months. Older age, male sex, and higher nicotine dependence are predictors of weight gain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Evaluate and correlate individual, work-related and organizational factors that influence adherence to standard precautions among nursing professionals of psychiatric hospitals in São Paulo. METHOD An exploratory cross-sectional study conducted with 35 nursing professionals, using the assessment tool for adherence to standard precautions through the Likert scale, ranging from 1 to 5. RESULTS Knowledge of the precautions received a high score (4.69); adherence received (3.86) and obstacles (3.78), while intermediaries and the scales of organizational factors received low scores (2.61). There was a strong correlation between the magnitude adherence scale and the personal protective equipment availability (r = 0.643; p = 0.000). The training scale for prevention of HIV exposure (p = 0.007) was statistically different between the nurses and nursing assistants. CONCLUSION The organizational factors negatively contributed to adherence to standard precautions, indicating that psychiatric institutions lack safe working conditions, ongoing training and management actions to control infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the effects of a standard influencing care choice. Firm(s) may increase the probability of offering safe products by incurring a cost. Under duopoly, they compete either in prices or in quantities. Under perfect information about safety for consumers, the selected standard that corrects a safety underinvestment is always compatible with competition. Safety over investment only emerges under competition in quantities and relatively low values of the cost. Under imperfect information about safety for consumers, the standard leads to a monopoly situation. However, for relatively large values of the cost, a standard cannot impede the market failure coming from the lack of information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractText BACKGROUND: Profiling sperm DNA present on vaginal swabs taken from rape victims often contributes to identifying and incarcerating rapists. Large amounts of the victim's epithelial cells contaminate the sperm present on swabs, however, and complicate this process. The standard method for obtaining relatively pure sperm DNA from a vaginal swab is to digest the epithelial cells with Proteinase K in order to solubilize the victim's DNA, and to then physically separate the soluble DNA from the intact sperm by pelleting the sperm, removing the victim's fraction, and repeatedly washing the sperm pellet. An alternative approach that does not require washing steps is to digest with Proteinase K, pellet the sperm, remove the victim's fraction, and then digest the residual victim's DNA with a nuclease. METHODS: The nuclease approach has been commercialized in a product, the Erase Sperm Isolation Kit (PTC Labs, Columbia, MO, USA), and five crime laboratories have tested it on semen-spiked female buccal swabs in a direct comparison with their standard methods. Comparisons have also been performed on timed post-coital vaginal swabs and evidence collected from sexual assault cases. RESULTS: For the semen-spiked buccal swabs, Erase outperformed the standard methods in all five laboratories and in most cases was able to provide a clean male profile from buccal swabs spiked with only 1,500 sperm. The vaginal swabs taken after consensual sex and the evidence collected from rape victims showed a similar pattern of Erase providing superior profiles. CONCLUSIONS: In all samples tested, STR profiles of the male DNA fractions obtained with Erase were as good as or better than those obtained using the standard methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The practice of sedation, including monitoring practice for digestive endoscopy, continues to evolve throughout the world. In many countries, including Switzerland, there is a trend towards increased utilization of sedation during both routine and advanced endoscopic procedures. Sedation improves patient satisfaction with endoscopy and also improves the quality of the examination. In addition, a trend can be observed towards an increasing use of propofol as the preferred sedative drug. Here we review the latest published data from surveys describing sedation and monitoring practice in different countries and compare them with our own data from successive nationwide surveys among Swiss gastroenterologists over a period of 20 years. This development between these socioeconomically very similar Western industrialized countries, however, shows some unique and surprising differences. In Germany and Switzerland, propofol use has become increasingly widespread, in Switzerland even to the extent that during the last few years propofol has overtaken benzodiazepine sedation, with an absolute majority of Swiss gastroenterologists using it without the assistance of an anesthesiologist. In addition, the change in Switzerland reflects a successful generalization of nonanesthesiologist-administered propofol (NAAP) sedation from the hospital setting to private practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A list of 681 UBVRI secondary standard stars for CCD photometry is presented. Visual magnitude ranges from 9.7 to 19.4, and the B-V colour index varies from 1.15 to 1.97. The stars are grouped into 11 different fields, each of them is generally observable in a single CCD frame. The stars are located near Landolt UBVRI equatorial standards, accessible to telescopes in both hemispheres, and mainly within the 5 - 8 hours range of right ascension. Photometry, equatorial coordinates and finding charts are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[eng] ISO standard 9001 is one of a set of management tools that libraries have adopted in recent years. This article focuses on libraries in higher education institutions that have received ISO certification of their quality management systems (ISO standard 9001:2000). We examine their reasons for seeking certification and the advantages and difficulties they have encountered in applying this ISO standard. Finally, we consider the future prospects of ISO standard 9001 in university libraries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the safety and efficacy of an intravitreal fluocinolone acetonide (FA) implant compared with standard therapy in subjects with noninfectious posterior uveitis (NIPU). DESIGN: Randomized, controlled, phase 2b/3, open-label, multicenter superiority trial. PARTICIPANTS: Subjects with unilateral or bilateral NIPU. METHODS: One hundred forty subjects received either a 0.59-mg FA intravitreal implant (n = 66) or standard of care (SOC; n = 74) with either systemic prednisolone or equivalent corticosteroid as monotherapy (> or =0.2 mg/kg daily) or, if judged necessary by the investigator, combination therapy with an immunosuppressive agent plus a lower dose of prednisolone or equivalent corticosteroid (> or =0.1 mg/kg daily). MAIN OUTCOME MEASURES: Time to first recurrence of uveitis. RESULTS: Eyes that received the FA intravitreal implant experienced delayed onset of observed recurrence of uveitis (P<0.01) and a lower rate of recurrence of uveitis (18.2% vs. 63.5%; P< or =0.01) compared with SOC study eyes. Adverse events frequently observed in implanted eyes included elevated intraocular pressure (IOP) requiring IOP-lowering surgery (occurring in 21.2% of implanted eyes) and cataracts requiring extraction (occurring in 87.8% of phakic implanted eyes). No treatment-related nonocular adverse events were observed in the implant group, whereas such events occurred in 25.7% of subjects in the SOC group. CONCLUSIONS: The FA intravitreal implant provided better control of inflammation in patients with uveitis compared with systemic therapy. Intraocular pressure and lens clarity of implanted eyes need close monitoring in patients receiving the FA intravitreal implant.