909 resultados para guided wave ultrasonics
Resumo:
In this paper we design and develop several filtering strategies for the analysis of data generated by a resonant bar gravitational wave (GW) antenna, with the goal of assessing the presence (or absence) therein of long-duration monochromatic GW signals, as well as the eventual amplitude and frequency of the signals, within the sensitivity band of the detector. Such signals are most likely generated in the fast rotation of slightly asymmetric spinning stars. We develop practical procedures, together with a study of their statistical properties, which will provide us with useful information on the performance of each technique. The selection of candidate events will then be established according to threshold-crossing probabilities, based on the Neyman-Pearson criterion. In particular, it will be shown that our approach, based on phase estimation, presents a better signal-to-noise ratio than does pure spectral analysis, the most common approach.
Resumo:
[spa] En este trabajo se analiza la relación entre la heterogeneidad étnica y la redistribución, utilizando la reciente y masiva llegada de inmigrantes a España. En concreto, se estudia el efecto de los cambios en la densidad de inmigrantes, observada entre 1998 y 2006, sobre los cambios en el gasto social municipal. La densidad de inmigrantes se instrumenta utilizando los patrones de establecimiento por país de origen para asignar los flujos predichos de inmigrantes a cada municipio. Los resultados evidencian que el gasto social incrementó menos en los municipios con mayores incrementos en la densidad de inmigrantes. También se proporciona evidencia de la existencia de una relación positiva entre la densidad de inmigrantes y el porcentaje de voto obtenidos por los partidos de derecha. Por tanto, estos resultados son consistentes con las teorías que predicen una relación negativa entre la heterogeneidad étnica y la redistribución.
Resumo:
[spa] En este trabajo se analiza la relación entre la heterogeneidad étnica y la redistribución, utilizando la reciente y masiva llegada de inmigrantes a España. En concreto, se estudia el efecto de los cambios en la densidad de inmigrantes, observada entre 1998 y 2006, sobre los cambios en el gasto social municipal. La densidad de inmigrantes se instrumenta utilizando los patrones de establecimiento por país de origen para asignar los flujos predichos de inmigrantes a cada municipio. Los resultados evidencian que el gasto social incrementó menos en los municipios con mayores incrementos en la densidad de inmigrantes. También se proporciona evidencia de la existencia de una relación positiva entre la densidad de inmigrantes y el porcentaje de voto obtenidos por los partidos de derecha. Por tanto, estos resultados son consistentes con las teorías que predicen una relación negativa entre la heterogeneidad étnica y la redistribución.
Resumo:
Simulaattorit ovat yksinkertaistettuja malleja tietyistä järjestelmän osioista. Niitä käytetään mallintamaan testattavan osion ympärillä olevien muiden osioiden ulkoista toimintaa, jotta testattavalle osiolle saadaan oikeanlainen toimintaympäristö aikaiseksi. Tilakoneita käytetään mallintamaan ohjelmistojen tai niiden osien toimintaa. Sanomaohjatuissa tilakoneissa tilojen vaihdot perustuvat saapuviin sanomiin. Tässä työssä esitellään erään ohjelmiston alijärjestelmän testaamisessa käytettävä arkkitehtuuri, joka perustuu suurelta osin simulaattoreiden käyttöön muiden alijärjestelmien mallintamisessa. Testattava ohjelmisto koostuu enimmäkseen tilakoneista, jotka vaihtavat keskenään sanomia ja ohjaavat näin toistensa tilasiirtymiä. Työn testausympäristö on suunniteltu juuri tämänkaltaisen ohjelmiston testaamiseen. Työssä esiteltävää testausympäristöä myöskin käytettiin useamman kuukauden ajan ja se todettiin toimivaksi. Joitakin testausympäristön käyttöohjeita, käyttökokemuksia sekä siihen liittyviä parannusehdotuksia käydään läpi työn loppuosassa. Erityisesti havaittiin miten tärkeää on testata implementaatiota jo luokka tasolla ennen alijärjestelmä tason testaukseen siirtymistä sekä päädyttiin siihen, että suunnitteluvaiheen pitäisi olla lähemmin liitoksissa alijärjestelmätestaukseen.
Resumo:
n this work we analyze the behavior of complex information in Fresnel domain taking into account the limited capability to display complex transmittance values of current liquid crystal devices, when used as holographic displays. In order to do this analysis we compute the reconstruction of Fresnel holograms at several distances using the different parts of the complex distribution (real and imaginary parts, amplitude and phase) as well as using the full complex information adjusted with a method that combines two configurations of the devices in an adding architecture. The RMS error between the amplitude of these reconstructions and the original amplitude is used to evaluate the quality of the information displayed. The results of the error analysis show different behavior for the reconstructions using the different parts of the complex distribution and using the combined method of two devices. Better reconstructions are obtained when using two devices whose configurations densely cover the complex plane when they are added. Simulated and experimental results are also presented.
Resumo:
Probabilistic inversion methods based on Markov chain Monte Carlo (MCMC) simulation are well suited to quantify parameter and model uncertainty of nonlinear inverse problems. Yet, application of such methods to CPU-intensive forward models can be a daunting task, particularly if the parameter space is high dimensional. Here, we present a 2-D pixel-based MCMC inversion of plane-wave electromagnetic (EM) data. Using synthetic data, we investigate how model parameter uncertainty depends on model structure constraints using different norms of the likelihood function and the model constraints, and study the added benefits of joint inversion of EM and electrical resistivity tomography (ERT) data. Our results demonstrate that model structure constraints are necessary to stabilize the MCMC inversion results of a highly discretized model. These constraints decrease model parameter uncertainty and facilitate model interpretation. A drawback is that these constraints may lead to posterior distributions that do not fully include the true underlying model, because some of its features exhibit a low sensitivity to the EM data, and hence are difficult to resolve. This problem can be partly mitigated if the plane-wave EM data is augmented with ERT observations. The hierarchical Bayesian inverse formulation introduced and used herein is able to successfully recover the probabilistic properties of the measurement data errors and a model regularization weight. Application of the proposed inversion methodology to field data from an aquifer demonstrates that the posterior mean model realization is very similar to that derived from a deterministic inversion with similar model constraints.
Resumo:
BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.
Resumo:
Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. All cases were planned and operated upon with the guided surgery technique. Results: A total of 122 implants were placed in 14 males and 5 females. The intraoperative surgical complications comprised a lack of primary stability, while the postoperative complications consisted of infections and a lack of implant osteointegration. Ten implants failed. The prosthetic complications in turn comprised loosening of the provisional prosthesis screws, prosthesis tooth fracture, and a lack of passive fit of the immediate prosthesis. The degree of patient satisfaction was evaluated using a verbal scale. Conclusions: Implant restoration with the guided surgery technique and immediate functional loading is a predictable procedure, provided patient selection and the surgical technique are adequate, affording lesser postoperative morbidity and increased patient satisfaction thanks to the immediate restoration of esthetics and function
Resumo:
Ultrasound image reconstruction from the echoes received by an ultrasound probe after the transmission of diverging waves is an active area of research because of its capacity to insonify at ultra-high frame rate with large regions of interest using small phased arrays as the ones used in echocardiography. Current state-of-the-art techniques are based on the emission of diverging waves and the use of delay and sum strategies applied on the received signals to reconstruct the desired image (DW/DAS). Recently, we have introduced the concept of Ultrasound Fourier Slice Imaging (UFSI) theory for the reconstruction of ultrafast imaging for linear acquisition. In this study, we extend this theory to sectorial acquisition thanks to the introduction of an explicit and invertible spatial transform. Starting from a diverging wave, we show that the direct use of UFSI theory along with the application of the proposed spatial transform allows reconstructing the insonified medium in the conventional Cartesian space. Simulations and experiments reveal the capacity of this new approach in obtaining competitive quality of ultrafast imaging when compared with the current reference method.
Resumo:
We systematically reviewed 25 randomised controlled trials of ultrasound-guided brachial plexus blockade that recruited 1948 participants: either one approach vs another (axillary, infraclavicular or supraclavicular); or one injection vs multiple injections. There were no differences in the rates of successful blockade with approach, relative risk (95% CI): axillary vs infraclavicular, 1.0 (1.0-1.1), p = 0.97; axillary vs supraclavicular, 1.0 (1.0-1.1), p = 0.68; and infraclavicular vs supraclavicular, 1.0 (1.0-1.1), p = 0.32. There was no difference in the rate of successful blockade with the number of injections, relative risk (95% CI) 1.0 (1.0-1.0), p = 0.69, for one vs multiple injections. The rate of procedural paraesthesia was less with one injection than multiple injections, relative risk (95% CI) 0.6 (0.4-0.9), p = 0.004.
Resumo:
OBJECTIVE: To determine the number of punctures in fine-needle aspiration biopsies required for a safe cytological analysis of thyroid nodules. MATERIALS AND METHODS: Cross-sectional study with focus on diagnosis. The study population included 94 patients. RESULTS: The mean age of the patients participating in the study was 52 years (standard-deviation = 13.7) and 90.4% of them were women. Considering each puncture as an independent event, the first puncture has showed conclusive results in 78.7% of cases, the second, in 81.6%, and the third, in 71.8% of cases. With a view to the increasing chance of a conclusive diagnosis at each new puncture, two punctures have showed conclusive results in 89.5% of cases, and three punctures, in 90.6% of cases with at least one conclusive result. CONCLUSION: Two punctures in fine-needle aspiration biopsies of thyroid nodules have lead to diagnosis in 89.5% of cases in the study sample, suggesting that there is no need for multiple punctures to safely obtain the diagnosis of thyroid nodules.
Resumo:
To sustain a lifelong ability to initiate organs, plants retain pools of undifferentiated cells with a preserved proliferation capacity. The root pericycle represents a unique tissue with conditional meristematic activity, and its tight control determines initiation of lateral organs. Here we show that the meristematic activity of the pericycle is constrained by the interaction with the adjacent endodermis. Release of these restraints by elimination of endodermal cells by single-cell ablation triggers the pericycle to re-enter the cell cycle. We found that endodermis removal substitutes for the phytohormone auxin-dependent initiation of the pericycle meristematic activity. However, auxin is indispensable to steer the cell division plane orientation of new organ-defining divisions. We propose a dual, spatiotemporally distinct role for auxin during lateral root initiation. In the endodermis, auxin releases constraints arising from cell-to-cell interactions that compromise the pericycle meristematic activity, whereas, in the pericycle, auxin defines the orientation of the cell division plane to initiate lateral roots.
Resumo:
Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.
Resumo:
Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.