554 resultados para germanium


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The conversion coefficients from air kerma to ICRU operational dose equivalent quantities for ENEA’s realization of the X-radiation qualities L10-L35 of the ISO “Low Air Kerma rate” series (L), N10-N40 of the ISO “Narrow spectrum” series (N) and H10-H60 of the ISO “High Air-kerma rate” (H) series and two beams at 5 kV and 7.5 kV were determined by utilising X-ray spectrum measurements. The pulse-height spectra were measured using a planar high-purity germanium spectrometer (HPGe) and unfolded to fluence spectra using a stripping procedure then validate with using Monte Carlo generated data of the spectrometer response. HPGe portable detector has a diameter of 8.5 mm and a thickness of 5 mm. The entrance window of the crystal is collimated by a 0.5 mm thick Aluminum ring to an open diameter of 6.5 mm. The crystal is mounted at a distance of 5 mm from the Berillium window (thickness 25.4 micron). The Monte Carlo method (MCNP-4C) was used to calculate the efficiency, escape and Compton curves of a planar high-purity germanium detector (HPGe) in the 5-60 keV energy. These curves were used for the determination of photon spectra produced by the X-ray machine SEIFERT ISOVOLT 160 kV in order to allow a precise characterization of photon beams in the low energy range, according to the ISO 4037. The detector was modelled with the MCNP computer code and validated with experimental data. To verify the measuring and the stripping procedure, the first and the second half-value layers and the air kerma rate were calculated from the counts spectra and compared with the values measured using an a free-air ionization chamber. For each radiation quality, the spectrum was characterized by the parameters given in ISO 4037-1. The conversion coefficients from the air kerma to the ICRU operational quantities Hp(10), Hp(0.07), H’(0.07) and H*(10) were calculated using monoenergetic conversion coefficients. The results are discussed with respect to ISO 4037-4, and compared with published results for low-energy X-ray spectra. The main motivation for this work was the lack of a treatment of the low photon energy region (from a few keV up to about 60 keV).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In dieser Arbeit wurde der instabile, Neutronenarme Kern 108Sn mit Hilfe der Coulomb-Anregung bei intermediaeren Energien in inverser Kinematik studiert. Diese Methode wurde bisher zur Untersuchung der ersten angeregten 2+ Zustaende und deren E2 Zerfallsraten in Kernen mit Kernladungszahl Z< 30 angewendet. 108Sn ist somit der Kern mit der groeßten Kernladungszahl, bei dem diese Studien bisher stattfanden. Das Ziel dieses Experiments war die Messung der unbekannten reduzierten Uebergangswahrscheinlichkeit B(E2,0+ -> 2+). Der B(E2)-Wert von 0.230(57) e2b2 wurde relativ zu dem bekannten Wert des Isotops 112Sn bestimmt. Das Experiment wurde an der GSI Darmstadt mit Hilfe des RISING Detektors und des Fragmentseperators (FRS) durchgefuehrt. Sekundaere Strahlen (108Sn, 112Sn) mit einer Energie von ca. 150 MeV pro Nukleon wurden auf ein 386 mg/cm2 dickes 197Au Target geschossen. Die Projektilfragmente wurden mit Hilfe des Fragmentseparators selektiert und identifiziert. Zur Selektion des Reaktionskanals und zur Bestimmung des Winkels der gestreuten Fragmente wurde das Teilchenteleskop CATE, das sich hinter dem Target befand, verwendet. Gammastrahlung, die in Koinzidenz mit den Projektilrestkernen emittiert wurde, wurde in den Germanium-Cluster Detektoren des RISING Detektors nachgewiesen. Der gemessene B(E2,0+ -> 2+)-Wert von 108Sn ist in Uebereinstimmung mit neueren Schalenmodellrechnungen, die auf realistischen effektiven Wechselwirkungen basieren und im Rahmen eines verallgemeinerten Seniorit¨ats-Schemas erklaert werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Germaniumdioxid (GeO2) ist ein Glasbildner, der wie das homologe SiO2 ein ungeordnetes tetraedrisches Netzwerk ausbildet. In dieser Arbeit werden mit Hilfe von Molekulardynamik-Computersimulationen die Struktur und Dynamik von GeO2 in Abhängigkeit von der Temperatur untersucht. Dazu werden sowohl Simulationen mit einem klassischen Paarpotentialmodell von Oeffner und Elliott als auch ab initio-Simulationen gemäß der Car-Parrinello-Molekulardynamik (CPMD), bei der elektronische Freiheitsgrade mittels Dichtefunktionaltheorie beschrieben werden, durchgeführt. In der klassischen Simulation werden dazu ein Temperaturen zwischen 6100 K und 2530 K betrachtet. Darüberhinaus ermöglichen Abkühlläufe auf T=300 K das Studium der Struktur des Glases. Zum Vergleich werden CPMD-Simulationen für kleinere Systeme mit 60 bzw. 120 Teilchen bei den Temperaturen 3760 K und 3000 K durchgeführt. In den klassischen Simulationen kann die im Experiment bis 1700 K nachgewiesene, im Vergleich zu SiO2 starke, Temperaturabhängigkeit der Dichte auch bei höheren Temperaturen beobachtet werden. Gute Übereinstimmungen der Simulationen mit experimentellen Daten zeigen sich bei der Untersuchung verschiedener struktureller Größen, wie z.B. Paarkorrelationsfunktionen, Winkelverteilungen, Koordinationszahlen und Strukturfaktoren. Es können leichte strukturelle Abweichungen der CPMD-Simulationen von den klassischen Simulationen aufgezeigt werden: 1. Die Paarabstände in CPMD sind durchweg etwas kleiner. 2. Es zeigt sich, daß die Bindungen in den ab initio-Simulationen weicher sind, was sich auch in einer etwas stärkeren Temperaturabhängigkeit der strukturellen Größen im Vergleich zu den klassischen Simulationen niederschlägt. 3. Für CPMD kann ein vermehrtes Auftreten von Dreierringstrukturen gezeigt werden. 4. In der CPMD werden temperaturabhängige Defektstrukturen in Form von Sauerstoffpaaren beobachtet, die vor allem bei 3760 K, kaum jedoch bei 3000 K auftreten. Alle strukturellen Unterschiede zwischen klassischer und CPMD-Simulation sind eindeutig nicht auf Finite-Size-Effekte aufgrund der kleinen Systemgrößen in den CPMD-Simulationen zurückzuführen, d.h. sie sind tatsächlich methodisch bedingt. Bei der Dynamik von GeO2 wird in den klassischen Simulationen ebenfalls eine gute Übereinstimmung mit experimentellen Daten beobachtet, was ein Vergleich der Diffusionskonstanten mit Viskositätsmessungen bei hohen Temperaturen belegt. Die Diffusionskonstanten zeigen teilweise ein verschiedenes Verhalten zum homologen SiO2. Sie folgen in GeO2 bei Temperaturen unter 3000 K einem Arrheniusgesetz mit einer deutlich niedrigeren Aktivierungsenergie. Darüberhinaus werden die Möglichkeiten der Parametrisierung eines neuen klassischen Paarpotentials mittels der Kräfte entlang der CPMD-Trajektorien untersucht. Es zeigt sich, daß derartige Parametrisierungen sehr stark von den gewählten Startparametern abhängen. Ferner führen sämtliche an die Schmelze parametrisierten Potentiale zu zu hohen Dichten im Vergleich zum Experiment. Zum einen liegt dies sehr wahrscheinlich daran,daß für das System GeO2 Kraftdaten allein nicht ausreichen, um grundlegende strukturelle Größen, wie z.B. Paarkorrelationen und Winkelverteilungen, der CPMD-Simulationen gut reproduzieren zu können. Zum anderen ist wohl die Beschreibung mittels Paarpotentialen nicht ausreichend und es ist erforderlich, Merkörperwechselwirkungen in Betracht zu ziehen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Das Element Arsen besitzt eine Reihe von Isotopen, die in nahezu trägerfreier Form (nca) produziert werden können und deshalb in der Radiopharmazie für die Diagnose oder Endoradiotherapie Verwendung finden können. Bei der Positronenemissionstomographie (PET) gibt es eine gewisse Lücke bei der Versorgung mit langlebigen Positronenemittern, die zur Untersuchung von langsamen physiologischen Prozessen wie z.B. der Biodistribution und Anreicherung von Antikörpern in Tumorgewebe eingesetzt werden können. Die beiden Arsenisotope 72As (T1/2 = 26 h, 88 % beta+) und 74As (T1/2 = 17,8 d, 29 % beta+) vereinen eine lange physikalische Halbwertszeit mit einer hohen Positronenemissionsrate und sind daher geeignete Kandidaten. Da das Verhalten von radioaktivem Arsen und seine Verwendung in der molekularen Bildgebung international relativ wenig bearbeitet sind, wurde die Radiochemie des Arsens von der Isotopenproduktion an Kernreaktor und Zyklotron, über die Entwicklung von Abtrennungsmethoden für Germanium und Arsen, bis hin zur Entwicklung einer soliden Markierungschemie für Antikörper weiterentwickelt. Die in dieser Arbeit bearbeiteten Felder sind: 1. Die Isotopenproduktion der relevanten Arsenisotope (72/74/77As) wurde an Kernreaktor und Zyklotron durch Bestrahlung von GeO2- und Germaniummetalltargets durchgeführt. Pro 6 h Bestrahlung von 100 mg Germanium konnten ca. 2 MBq 77As am TRIGA Reaktor in Mainz hergestellt werden. Am Zyklotron des DKFZ in Heidelberg konnten unter optimierten Bedingungen bei der Bestrahlung von Germaniummetall (EP = 15 Mev, 20 µA, 200 µAh) ca. 4 GBq 72As und ca. 400 MBq 74As produziert werden. 2. Die Entwicklung neuer Abtrennungsmethoden für nca 72/74/77As von makroskopischen Mengen Germanium wurde vorangetrieben. Für die Aufarbeitung von GeO2- und Germaniummetalltargets kamen insgesamt 8 verschiedene Methoden wie Festphasenextraktion, Flüssig-Flüssig-Extraktion, Destillation, Anionenaustauschchromatographie zum Einsatz. Die erzielten Ausbeuten lagen dabei zwischen 31 und 56 %. Es wurden Abtrennungsfaktoren des Germaniums zwischen 1000 und 1•10E6 erreicht. Alle erfolgreichen Abtrennungsmethoden lieferten *As(III) in 500 µl PBS-Puffer bei pH 7. Diese Form des Radioarsens ist für die Markierung von SH-modifizierten Molekülen, wie z.B. Antikörpern geeignet. 3. Die Entwicklung von Methoden zur Bestimmung des Oxidationszustandes von nca *As in organischem, neutralem wässrigen, oder stark sauren Medium mittels Radio-DC und Anionenaustauschchromatographie wurde durchgeführt und führte zu einem besseren Verständnis der Redoxchemie des nca *As. 4. SH-modifizierte Antikörper wurden mit 72/74/77As(III) markiert. Dabei wurden zwei Methoden (Modifizierung mit SATA und TCEP) miteinander verglichen. Während das *As(III) bei Verwendung von TCEP in Ausbeuten > 90 % mit dem Antikörper reagierte, wurde für SATA-modifizierte Antikörper in Abhängigkeit von der verwendeten Abtrennungsmethode eine breite Spanne von 0 % bis > 90 % beobachtet. 5. Es wurden Phantommessungen mit 18F, 72As und 74As am µ-PET-Scanner durchgeführt, um erste Aussagen über die zu erwartende Auflösung der Arsenisotope zu erhalten. Die Auflösung von 74As ist mit 18F vergleichbar, während die von 72As erkennbar schlechter ist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hypernuclear physics is currently attracting renewed interest, due tornthe important role of hypernuclei spectroscopy rn(hyperon-hyperon and hyperon-nucleon interactions) rnas a unique toolrnto describe the baryon-baryon interactions in a unified way and to rnunderstand the origin of their short-range.rnrnHypernuclear research will be one of the main topics addressed by the {sc PANDA} experimentrnat the planned Facility for Antiproton and Ion Research {sc FAIR}.rnThanks to the use of stored $overline{p}$ beams, copiousrnproduction of double $Lambda$ hypernuclei is expected at thern{sc PANDA} experiment, which will enable high precision $gamma$rnspectroscopy of such nuclei for the first time.rnAt {sc PANDA} excited states of $Xi^-$ hypernuclei will be usedrnas a basis for the formation of double $Lambda$ hypernuclei.rnFor their detection, a devoted hypernuclear detector setup is planned. This setup consists ofrna primary nuclear target for the production of $Xi^{-}+overline{Xi}$ pairs, a secondary active targetrnfor the hypernuclei formation and the identification of associated decay products and a germanium array detector to perform $gamma$ spectroscopy.rnrnIn the present work, the feasibility of performing high precision $gamma$rnspectroscopy of double $Lambda$ hypernuclei at the {sc PANDA} experiment has been studiedrnby means of a Monte Carlo simulation. For this issue, the designing and simulation of the devoted detector setup as well as of the mechanism to produce double $Lambda$ hypernuclei have been optimizedrntogether with the performance of the whole system. rnIn addition, the production yields of double hypernuclei in excitedrnparticle stable states have been evaluated within a statistical decay model.rnrnA strategy for the unique assignment of various newly observed $gamma$-transitions rnto specific double hypernuclei has been successfully implemented by combining the predicted energy spectra rnof each target with the measurement of two pion momenta from the subsequent weak decays of a double hypernucleus.rn% Indeed, based on these Monte Carlo simulation, the analysis of the statistical decay of $^{13}_{Lambda{}Lambda}$B has been performed. rn% As result, three $gamma$-transitions associated to the double hypernuclei $^{11}_{Lambda{}Lambda}$Bern% and to the single hyperfragments $^{4}_{Lambda}$H and $^{9}_{Lambda}$Be, have been well identified.rnrnFor the background handling a method based on time measurement has also been implemented.rnHowever, the percentage of tagged events related to the production of $Xi^{-}+overline{Xi}$ pairs, variesrnbetween 20% and 30% of the total number of produced events of this type. As a consequence, further considerations have to be made to increase the tagging efficiency by a factor of 2.rnrnThe contribution of the background reactions to the radiation damage on the germanium detectorsrnhas also been studied within the simulation. Additionally, a test to check the degradation of the energyrnresolution of the germanium detectors in the presence of a magnetic field has also been performed.rnNo significant degradation of the energy resolution or in the electronics was observed. A correlationrnbetween rise time and the pulse shape has been used to correct the measured energy. rnrnBased on the present results, one can say that the performance of $gamma$ spectroscopy of double $Lambda$ hypernuclei at the {sc PANDA} experiment seems feasible.rnA further improvement of the statistics is needed for the background rejection studies. Moreover, a more realistic layout of the hypernuclear detectors has been suggested using the results of these studies to accomplish a better balance between the physical and the technical requirements.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurde ein neuartiger Experimentaufbau -- das γ3 Experiment -- zur Messung von photoneninduzierten Kern-Dipolanregungen in stabilen Isotopen konzipiert und an der High Intensity γ-Ray Source (HIγS) an der Duke University installiert.rnDie hohe Energieauflösung und die hohe Nachweiseffizienz des Detektoraufbaus, welcher aus einer Kombination von LaBr Szintillatoren und hochreinen Germanium-Detektoren besteht, erlaubt erstmals die effiziente Messung von γ-γ-Koinzidenzen in Verbindung mit der Methode der Kernresonanzfluoreszenz.rnDiese Methode eröffnet den Zugang zum Zerfallsverhalten der angeregten Dipolzustände als zusätzlicher Observablen, die ein detaillierteres Verständnis der zugrunde liegenden Struktur dieser Anregungen ermöglicht.rnDer Detektoraufbau wurde bereits erfolgreich im Rahmen von zwei Experimentkampagnen in 2012 und 2013 für die Untersuchung von 13 verschiedenen Isotopen verwendet. Im Fokus dieser Arbeit stand die Analyse der Pygmy-Dipolresonanz (PDR) im Kern 140Ce im Energiebereich von 5,2 MeV bis 8,3 MeV basierend auf den mit dem γ3 Experimentaufbau gemessenen Daten. Insbesondere das Zerfallsverhalten der Zustände, die an der PDR beteiligt sind, wurde untersucht. Der Experimentaufbau, die Details der Analyse sowie die Resultate werden in der vorliegenden Arbeit präsentiert. Desweiteren erlaubt ein Vergleich der Ergebnisse mit theoretischen Rechnungen im quasi-particle phonon model (QPM) eine Interpretation des beobachteten Zerfallsverhaltens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are many elements which are detrimental to the current efficiency in the electrolysis of zinc sulphate solution. Fortunately the majority of these elements are easily removed in the purification process and cause no further trouble. The elements that are likely to cause trouble in ordinary plant operations are antimony, arsenic, cobalt, nickel, manganese and germanium. The following tests were made to determine the mutual effect on the current efficiency when several of the impurities were present in the electrolyte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recycling of oceanic crust into the deep mantle via subduction is a widely accepted mechanism for creating compositional heterogeneity in the upper mantle and for explaining the distinct geochemistry of mantle plumes. The oxygen isotope ratios (d18O) of some ocean island basalts (OIB) span values both above and below that of unmetasomatised upper mantle (5.5 ± 0.4 per mil) and provide support for this hypothesis, as it is widely assumed that most variations in d18O are produced by near-surface low-temperature processes. Here we show a significant linear relationship between d18O and stable iron isotope ratios (d57Fe) in a suite of pristine eclogite xenoliths. The d18O values of both bulk samples and garnets range from values within error of normal mantle to significantly lighter values. The observed range and correlation between d18O and d57Fe is unlikely to be inherited from oceanic crust, as d57Fe values determined for samples of hydrothermally altered oceanic crust do not differ significantly from the mantle value and show no correlation with d18O. It is proposed that the correlated d57Fe and d18O variations in this particular eclogite suite are predominantly related to isotopic fractionation by disequilibrium partial melting although modification by melt percolation processes cannot be ruled out. Fractionation of Fe and O isotopes by removal of partial melt enriched in isotopically heavy Fe and O is supported by negative correlations between bulk sample d57Fe and Cr content and bulk sample and garnet d18O and Sc contents, as Cr and Sc are elements that become enriched in garnet- and pyroxene-bearing melt residues. Melt extraction could take place either during subduction, where the eclogites represent the residues of melted oceanic lithosphere, or could take place during long-term residence within the lithospheric mantle, in which case the protoliths of the eclogites could be of either crustal or mantle origin. This modification of both d57Fe and d18O by melting processes and specifically the production of low-d18O signatures in mafic rocks implies that some of the isotopically light d18O values observed in OIB and eclogite xenoliths may not necessarily reflect near-surface processes or components.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In-situ proton-microprobe analyses are presented for glasses, plagioclases, pyroxenes, olivines, and spinels in eleven samples from Sites 834-836, 839, and 841 (vitrophyric rhyolite), plus a Tongan dacite. Elements analyzed are Mn, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, Pb, and Sn (in spinels only). The data are used to calculate two sets of partition coefficients, one set based on the ratio of element in mineral/element in coexisting glass. The second set of coefficients, thought to be more robust, is corrected by application of the Rayleigh fractionation equations, which requires additional use of modal data. Data are presented for phenocryst core-rim phases and microphenocryst-groundmass phases from a few samples. Comparison with published coefficients reveals an overall consistency with those presented here, but with some notable anomalies. Examples are relatively high Zr values for pyroxenes and abnormally low Mn values in olivines and clinopyroxenes from Site 839 lavas. Some anomalies may reflect kinetic effects, but interpretation of the coefficients is complicated, especially in olivines from Sites 836 and 839, by possible crystal-liquid disequilibrium resulting from mixing processes.