970 resultados para Setup errors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality of temperature and humidity retrievals from the infrared SEVIRI sensors on the geostationary Meteosat Second Generation (MSG) satellites is assessed by means of a one dimensional variational algorithm. The study is performed with the aim of improving the spatial and temporal resolution of available observations to feed analysis systems designed for high resolution regional scale numerical weather prediction (NWP) models. The non-hydrostatic forecast model COSMO (COnsortium for Small scale MOdelling) in the ARPA-SIM operational configuration is used to provide background fields. Only clear sky observations over sea are processed. An optimised 1D–VAR set-up comprising of the two water vapour and the three window channels is selected. It maximises the reduction of errors in the model backgrounds while ensuring ease of operational implementation through accurate bias correction procedures and correct radiative transfer simulations. The 1D–VAR retrieval quality is firstly quantified in relative terms employing statistics to estimate the reduction in the background model errors. Additionally the absolute retrieval accuracy is assessed comparing the analysis with independent radiosonde and satellite observations. The inclusion of satellite data brings a substantial reduction in the warm and dry biases present in the forecast model. Moreover it is shown that the retrieval profiles generated by the 1D–VAR are well correlated with the radiosonde measurements. Subsequently the 1D–VAR technique is applied to two three–dimensional case–studies: a false alarm case–study occurred in Friuli–Venezia–Giulia on the 8th of July 2004 and a heavy precipitation case occurred in Emilia–Romagna region between 9th and 12th of April 2005. The impact of satellite data for these two events is evaluated in terms of increments in the integrated water vapour and saturation water vapour over the column, in the 2 meters temperature and specific humidity and in the surface temperature. To improve the 1D–VAR technique a method to calculate flow–dependent model error covariance matrices is also assessed. The approach employs members from an ensemble forecast system generated by perturbing physical parameterisation schemes inside the model. The improved set–up applied to the case of 8th of July 2004 shows a substantial neutral impact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Experimenten an lasergekühlten, in einer linearen Paulfalle gespeicherten $Ca^+$-Ionen wurde dieLebensdauer des metastabilen $3D_{5/2}$-Niveaus durch Beobachtung von Quantensprüngen einzelner Ionen zu 1100(18)msbestimmt. Systematische Fehler durch quenchende Stöße oder Stark-Mischen durch das Speicherfeld liegen unterhalb dererreichten Genauigkeit. Abweichungen von früheren Messungen konnten durch eine vernachlässigte Abhängigkeit derLebensdauer von der Laserleistung des Rückpumplasers erklärt werden. Das Endergebnis zeigt gute Übereinstimmung mitneueren theoretischen Werten. In weiteren Messungen an zehn Ionen wurde in einigen Messreihen eine deutliche Reduktionder Lebensdauer gegenüber einem einzelnen Ion festgestellt. Dabei wurden mehr koinzidente Zerfälle von zwei und dreiIonen beobachtet als für unabhängige Teilchen zu erwarten. In einem Ionenkristall wurde eine räumliche Trennung atomarer Zustände erreicht. Dabei wurde ein Teil der Ionen einesKristalls aus einigen hundert Ionen in den metastabilen Zustand gepumpt, der von den Kühllasern vollständig entkoppeltist. Durch sympathetische Kühlung werden diese Ionen weiterhin gekühlt und der Kristall schmilzt nicht. Durch denLichtdruck, den die Kühllaser ausgeüben, werden die Ionen nach atomaren Zuständen sortiert, weil die lasergekühltenIonen einen Rückstoß erfahren, die übrigen aber nicht. Für zukünftige Experimente wurden Verbesserungen des experimentellen Aufbaus auf den Weg gebracht. So wurden Methodenund Komponenten für eine verbesserte Frequenzstabilisierung der Diodenlaser entwickelt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D video-fluoroscopy is an accurate but cumbersome technique to estimate natural or prosthetic human joint kinematics. This dissertation proposes innovative methodologies to improve the 3D fluoroscopic analysis reliability and usability. Being based on direct radiographic imaging of the joint, and avoiding soft tissue artefact that limits the accuracy of skin marker based techniques, the fluoroscopic analysis has a potential accuracy of the order of mm/deg or better. It can provide fundamental informations for clinical and methodological applications, but, notwithstanding the number of methodological protocols proposed in the literature, time consuming user interaction is exploited to obtain consistent results. The user-dependency prevented a reliable quantification of the actual accuracy and precision of the methods, and, consequently, slowed down the translation to the clinical practice. The objective of the present work was to speed up this process introducing methodological improvements in the analysis. In the thesis, the fluoroscopic analysis was characterized in depth, in order to evaluate its pros and cons, and to provide reliable solutions to overcome its limitations. To this aim, an analytical approach was followed. The major sources of error were isolated with in-silico preliminary studies as: (a) geometric distortion and calibration errors, (b) 2D images and 3D models resolutions, (c) incorrect contour extraction, (d) bone model symmetries, (e) optimization algorithm limitations, (f) user errors. The effect of each criticality was quantified, and verified with an in-vivo preliminary study on the elbow joint. The dominant source of error was identified in the limited extent of the convergence domain for the local optimization algorithms, which forced the user to manually specify the starting pose for the estimating process. To solve this problem, two different approaches were followed: to increase the optimal pose convergence basin, the local approach used sequential alignments of the 6 degrees of freedom in order of sensitivity, or a geometrical feature-based estimation of the initial conditions for the optimization; the global approach used an unsupervised memetic algorithm to optimally explore the search domain. The performances of the technique were evaluated with a series of in-silico studies and validated in-vitro with a phantom based comparison with a radiostereometric gold-standard. The accuracy of the method is joint-dependent, and for the intact knee joint, the new unsupervised algorithm guaranteed a maximum error lower than 0.5 mm for in-plane translations, 10 mm for out-of-plane translation, and of 3 deg for rotations in a mono-planar setup; and lower than 0.5 mm for translations and 1 deg for rotations in a bi-planar setups. The bi-planar setup is best suited when accurate results are needed, such as for methodological research studies. The mono-planar analysis may be enough for clinical application when the analysis time and cost may be an issue. A further reduction of the user interaction was obtained for prosthetic joints kinematics. A mixed region-growing and level-set segmentation method was proposed and halved the analysis time, delegating the computational burden to the machine. In-silico and in-vivo studies demonstrated that the reliability of the new semiautomatic method was comparable to a user defined manual gold-standard. The improved fluoroscopic analysis was finally applied to a first in-vivo methodological study on the foot kinematics. Preliminary evaluations showed that the presented methodology represents a feasible gold-standard for the validation of skin marker based foot kinematics protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative branch determination in polyolefins by solid- and melt-state 13C NMR has been investigated. Both methods were optimised toward sensitivity per unit time. While solid-state NMR was shown to give quick albeit only qualitative results, melt-state NMR allowed highly time efficient accurate branch quantification. Comparison of spectra obtained using spectrometers operating at 300, 500 and 700 MHz 1H Larmor frequency, with 4 and 7~mm MAS probeheads, showed that the best sensitivity was achieved at 500 MHz using a 7 mm 13C-1H optimised high temperature probehead. For materials available in large quantities, static melt-state NMR, using large diameter detection coils and high coil filling at 300 MHz, was shown to produce comparable results to melt-state MAS measurements in less time. While the use of J-coupling mediated polarisation transfer techniques was shown to be possible, direct polarisation via single-pulse excitation proved to be more suitable for branch quantification in the melt-state. Artificial line broadening, introduced by FID truncation, was able to be reduced by the use of π pulse-train heteronuclear dipolar decoupling. This decoupling method, when combined with an extended duty-cycle, allowed for significant improvement in resolution. Standard setup, processing and analysis techniques were developed to minimise systematic errors contributing to the measured branch contents. The final optimised melt-state MAS NMR method was shown to allow time efficient quantification of comonomer content and distribution in both polyethylene- and polypropylene-co-α-olefins. The sensitivity of the technique was demonstrated by quantifying branch concentrations of 8 branches per 100,000 CH2 for an industrial ‘linear’ polyethylene in only 13 hours. Even lower degrees of 3–8 long-chain branches per 100,000 carbons were able to be estimated in just 24 hours for a series of γ-irradiated polypropylene homopolymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes the development of a new body-counter system based on HPGe detectors and installed at IVM of KIT. The goal, achieved, was the improvement of the ability to detect internal contaminations in the human body, especially the ones concerning low-energy emitters and multiple nuclides. The development of the system started with the characterisation of detectors purchased for this specific task, with the optimisation of the different desired measurement configurations following and ending with the installation and check of the results. A new software has been developed to handle the new detectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Progettazione dell'amplificatore, allestimento del banco di misure e misurazione del rumore di drain nei MOSFET di potenza

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electric dipole response of neutron-rich nickel isotopes has been investigated using the LAND setup at GSI in Darmstadt (Germany). Relativistic secondary beams of 56−57Ni and 67−72Ni at approximately 500 AMeV have been generated using projectile fragmentation of stable ions on a 4 g/cm2 Be target and subsequent separation in the magnetic dipole fields of the FRagment Separator (FRS). After reaching the LAND setup in Cave C, the radioactive ions were excited electromagnetically in the electric field of a Pb target. The decay products have been measured in inverse kinematics using various detectors. Neutron-rich 67−69Ni isotopes decay by the emission of neutrons, which are detected in the LAND detector. The present analysis concentrates on the (gamma,n) and (gamma,2n) channels in these nuclei, since the proton and three-neutron thresholds are unlikely to be reached considering the virtual photon spectrum for nickel ions at 500 AMeV. A measurement of the stable 58Ni isotope is used as a benchmark to check the accuracy of the present results with previously published data. The measured (gamma,n) and (gamma,np) channels are compared with an inclusive photoneutron measurement by Fultz and coworkers, which are consistent within the respective errors. The measured excitation energy distributions of 67−69Ni contain a large portion of the Giant Dipole Resonance (GDR) strength predicted by the Thomas-Reiche-Kuhn energy-weighted sum rule, as well as a significant amount of low-lying E1 strength, that cannot be attributed to the GDR alone. The GDR distribution parameters are calculated using well-established semi-empirical systematic models, providing the peak energies and widths. The GDR strength is extracted from the chi-square minimization of the model GDR to the measured data of the (gamma,2n) channel, thereby excluding any influence of eventual low-lying strength. The subtraction of the obtained GDR distribution from the total measured E1 strength provides the low-lying E1 strength distribution, which is attributed to the Pygmy Dipole Resonance (PDR). The extraction of the peak energy, width and strength is performed using a Gaussian function. The minimization of trial Gaussian distributions to the data does not converge towards a sharp minimum. Therefore, the results are presented by a chi-square distribution as a function of all three Gaussian parameters. Various predictions of PDR distributions exist, as well as a recent measurement of the 68Ni pygmy dipole-resonance obtained by virtual photon scattering, to which the present pygmy dipole-resonance distribution is also compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Collinear laser spectroscopy has been used as a tool for nuclear physics for more than 30 years. The unique possibility to extract nuclear properties like spins, radii and nuclear moments in a model-independent manner leads to important physics results to test the predictive power of existing nuclear models. rnThis work presents the construction and the commissioning of a new collinear laser spectroscopy experiment TRIGA-LASER as a part of the TRIGA-SPEC facility at the TRIGA research reactor at the University of Mainz. The goal of the experiment is to study the nuclear structure of radioactive isotopes which will be produced by neutron-induced fission near the reactor core and transported to an ion source by a gas jet system. rnThe versatility of the collinear laser spectroscopy technique will be exploited in the second part of this thesis. The nuclear spin and the magnetic moment of the neutron-deficient isotope Mg-21 will be presented, which were measured by the detection of the beta-decay asymmetry induced by nuclear polarization after optical pumping. A combination of this detection method with the classical fluorescence detection is then used to determine the isotope shifts of the neutron-rich magnesium isotopes from Mg-24 through Mg-32 to study the transition to the ''island of inversion''.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La messa a punto di tecniche come il patch clamp e la creazione di doppi strati lipidici artificiali (artificial bilayers) ha permesso di effettuare studi su canali ionici per valutarne la permeabilità, la selettività ionica, la dipendenza dal voltaggio e la cinetica, sia in ambito di ricerca, per analizzarne il funzionamento specifico, sia in quello farmaceutico, per studiare la risposta cellulare a nuovi farmaci prodotti. Tali tecniche possono essere inoltre impiegate nella realizzazione di biosensori, combinando così i vantaggi di specificità e sensibilità dei sistemi biologici alla veloce risposta quantitativa degli strumenti elettrochimici. I segnali in corrente che vengono rilevati con questi metodi sono dell’ordine dei pA e richiedono perciò l’utilizzo di strumentazioni molto costose e ingombranti per amplificarli, analizzarli ed elaborarli correttamente. Il gruppo di ricerca afferente al professor Tartagni della facoltà di ingegneria di Cesena ha sviluppato un sistema miniaturizzato che possiede molte delle caratteristiche richieste per questi studi. L’obiettivo della tesi riguarda la caratterizzazione sperimentale di tale sistema con prove di laboratorio eseguite in uno spazio ridotto e senza l’impiego di ulteriori strumentazioni ad eccezione del PC. In particolare le prove effettuate prevedono la realizzazione di membrane lipidiche artificiali seguita dall’inserimento e dallo studio del comportamento di due particolari canali ionici comunemente utilizzati per questa tipologia di studi: la gramicidina A, per la facilità d’inserimento nella membrana e per la bassa conduttanza del singolo canale, e l’α-emolisina, per l’attuale impiego nella progettazione e realizzazione di biosensori. Il presente lavoro si sviluppa in quattro capitoli di seguito brevemente riassunti. Nel primo vengono illustrate la struttura e le funzioni svolte dalla membrana cellulare, rivolgendo particolare attenzione ai fosfolipidi e alle proteine di membrana; viene inoltre descritta la struttura dei canali ionici utilizzati per gli esperimenti. Il secondo capitolo comprende una descrizione del metodo utilizzato per realizzare i doppi strati lipidici artificiali, con riferimento all’analogo elettrico che ne risulta, ed una presentazione della strumentazione utilizzata per le prove di laboratorio. Il terzo e il quarto capitolo sono dedicati all’elaborazione dei dati raccolti sperimentalmente: in particolare vengono prima analizzati quelli specifici dell’amplificatore, quali quelli inerenti il rumore che si somma al segnale utile da analizzare e la variabilità inter-prototipo, successivamente si studiano le prestazioni dell’amplificatore miniaturizzato in reali condizioni sperimentali e dopo aver inserito i canali proteici all’interno dei bilayers lipidici.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In questo lavoro ci si propone di descrivere la realizzazione di un sistema laser con cavit´a esterna e di un apparato da ultra-alto-vuoto, che verranno impiegati in un esperimento di miscele di atomi ultrafreddi che utilizza due specie atomiche di bosoni: 87Rb e 41K. Speciale attenzione viene rivolta verso le caratteristiche dello schema utilizzato e sul sistema di controllo in temperatura, che rendono questo sistema laser particolarmente stabile in frequenza e insensibile alle vibrazioni e variazioni di temperatura. Si sono poi analizzate le propriet´a dei materiali impiegati e delle procedure sperimentali adottate per la realizzazione del nuovo apparato da vuoto, al fine di garantire migliori prestazioni rispetto al sistema attualmente in uso.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ion traps have been established as a powerful tool for ion cooling and laser spectroscopy experiments since a long time ago. SpecTrap, one of the precision experiments associated to the HITRAP facility at GSI, is implementing a Penning trap for studies of large bunches of externally produced highly charged ions. The extremely strong electric and magnetic fields that exist around the nuclei of heavy elements drastically change their electronic properties, such as energy level spacings and radiative lifetimes. The electrons can therefore serve as sensitive probes for nuclear properties such as size, magnetic moment and spatial distribution of charge and magnetization. The energies of forbidden fine and hyperfine structure transitions in such ions strongly depend on the nuclear charge and shift from the microwave domain into the optical domain. Thus, they become accessible for laser spectroscopy and its potentially high accuracy. A number of such measurements has been performed in storage rings and electron beam ion traps and yielded results with relative accuracies in the 10

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this dissertation is to show the power of contrastive analysis in successfully predicting the errors a language learner will make by means of a concrete case study. First, there is a description of what language transfer is and why it is important in the matter of second language acquisition. Second, a brief explanation of the history and development of contrastive analysis will be offered. Third, the focus of the thesis will move to an analysis of errors usually made by language learners. To conclude, the dissertation will focus on the concrete case study of a Russian learner of English: after an analysis of the errors the student is likely to make, a recorded conversation will be examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diese Arbeit befasst sich mit der photoinduzierten Erzeugung neutraler Pionen, sehr nahe an der Schwellenenergie. Dabei werden zwei Ziele verfolgt: Zum einen die Überprüfung von Vorhersagen dieser effektiven Theorien und Modelle, zum anderen werden hier erstmals alle relevanten Partialwellenamplituden modellunabhängig aus gemessenen Observablen bestimmt. Diese Methode soll in Zukunft auch bei höheren Energien im Bereich der Nukleonresonanzen Anwendung finden. rnrnKonkret wird die Durchführung und Analyse eines Experiments vorgestellt, welches am Mainzer Mikrotron (MAMI) in den Jahren 2010 bis 2013 mit zirkular polarisiertem Photonenstrahl stattfand. Der Photonenstrahl wurde an einer Anlage zur Erzeugung energiemarkierter Bremsstrahlung aus dem Elektronenstrahl von MAMI gewonnen. Zum Nachweis der Reaktionsprodukte diente das hermetische 4pi CB/TAPS-Detektorsystem. Erstmalig standen bei derartigen Messungen auch transversal polarisierte Protonen zur Verfügung. Dazu wird Butanol in einer speziellen Apparatur dynamisch polarisiert. Molekularer Wasserstoff lässt sich aufgrund der para-Konfiguration nicht polarisieren. Wegen der Verwendung von Butanol als Targetmaterial, bei dem weniger als 5% aller erzeugten Pionen an polarisierten Protonen produziert wurden, ist die Behandlung des Untergrunds eine zentrale Aufgabe. rnrnEs werden zwei Methoden der Untergrundseparation vorgestellt, wovon die bessere in der Analyse angewendet wurde. Abschließend findet eine ausführliche Bewertung systematischer Fehler statt.rnrnDie erstmalige Verwendung transversal polarisierter Protonen ermöglicht den Zugang zu bisher nicht gemessenen Spin"=Freiheitsgraden. In Kombination mit einem komplementären Vorläufer-Experiment aus dem Jahr 2008 mit linear polarisiertem Photonenstrahl konnten aus den gewonnenen Daten erstmals alle komplexen s- und p-Partialwellenamplituden modellunabhängig bestimmt werden. rnrnDarüber hinaus wurden im Rahmen dieser Arbeit wesentliche Verbesserungen am apparativen Aufbau erzielt. Beispiele sind ein Elektronenstrahl-Polarimeter, ein zellularer CB-Multiplizitätstrigger, sowie signifikante Verbesserungen der Datennahmeelektronik und des Triggersystems, die teilweise in dieser Arbeit vorgestellt werden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this dissertation is to provide a translation from English into Italian of an extract from the research report “The Nature of Errors Made by Drivers”. The research was conducted by the MUARC (the Monash University Accident Research Centre) and published in June 2011 by Austroads, the association of Australasian road transport and traffic agencies. The excerpt chosen for translation is the third chapter, which provides an overview of the on-road pilot study conducted to analyse why drivers make mistakes during their everyday drive, including the methodology employed and the results obtained. This work is divided into six sections. It opens with an introduction on the topic and the formal structure of the report, followed by the first chapter, which provides an overview of the main features of the languages for special purposes and the specialised texts, an analysis of the text type and a presentation of the extract chosen for translation. In the second chapter the linguistic and extralinguistic resources available to specialised translators are presented, focussing on the ones used to translate the text. The third chapter is dedicated to the source text and its translation, while the fourth one provides an analysis of the strategies chosen to translate the text and a comment on the solutions to problematic passages. Finally, the last section – the conclusion – provides a comment on the entire work and on the professional activity of translators. The work closes with an appendix, which contains a glossary of the terms extracted from the translated text.