996 resultados para Process Standardization
Resumo:
This paper discusses the results of applied research on the eco-driving domain based on a huge data set produced from a fleet of Lisbon's public transportation buses for a three-year period. This data set is based on events automatically extracted from the control area network bus and enriched with GPS coordinates, weather conditions, and road information. We apply online analytical processing (OLAP) and knowledge discovery (KD) techniques to deal with the high volume of this data set and to determine the major factors that influence the average fuel consumption, and then classify the drivers involved according to their driving efficiency. Consequently, we identify the most appropriate driving practices and styles. Our findings show that introducing simple practices, such as optimal clutch, engine rotation, and engine running in idle, can reduce fuel consumption on average from 3 to 5l/100 km, meaning a saving of 30 l per bus on one day. These findings have been strongly considered in the drivers' training sessions.
Resumo:
Os programas de melhoria contínua dos processos são cada vez mais a aposta das empresas para fazer face ao mercado. Através da implementação destes programas é possível conferir simplicidade e padronização aos processos e consequentemente reduzir os custos com desperdícios internos relacionados com a qualidade dos mesmos. As ferramentas de melhoria da qualidade e as ferramentas associadas ao Lean Thinking representam um pilar importante no sucesso de qualquer programa de melhoria contínua dos processos. Estas ferramentas constituem meios úteis na análise, controlo, organização de dados importantes para a correta tomada de decisão nas organizações. O presente projeto tem como principal objetivo a conceção e implementação de um programa de melhoria da qualidade na Eurico Ferreira, S.A., tendo por base a avaliação da satisfação do cliente e a aplicação dos 5S. Neste contexto, o trabalho teve como fundamentação teórica a Gestão da Qualidade, Lean Thinking e algumas ferramentas de ambas as matérias. Posteriormente foi selecionada a área de negócio da empresa a abordar. Após a seleção, realizou-se um diagnóstico inicial do processo identificando os diversos pontos de melhoria onde foram aplicadas algumas ferramentas do Lean Thinking, nomeadamente o Value Stream Mapping e a metodologia 5S. Com a primeira foi possível construir um mapa do estado atual do processo, no qual estavam representados todos os intervenientes assim como o fluxo de materiais e de informação ao longo do processo. A metodologia 5S permitiu atuar sobre os desperdícios, identificando e implementando diversas melhorias no processo. Concluiu-se que a implementação das ferramentas contribuiu eficientemente para a melhoria contínua da qualidade nos processos, tendo sido decisão da coordenação alargar o âmbito do projeto aos restantes armazéns do centro logístico da empresa. Pode afirmar-se com recurso à satisfação do cliente expressa através da evolução favorável do Service-level agreement que as ferramentas implementadas têm gerado resultados muito positivos no curto prazo.
Resumo:
The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.
Resumo:
Solution enthalpies of 18-crown-6 have been obtained for a set of 14 protic and aprotic solvents at 298.15 K. The complementary use of Solomonov's methodology and a QSPR-based approach allowed the identification of the most significant solvent descriptors that model the interaction enthalpy contribution of the solution process (Delta H-int(A/S)). Results were compared with data previously obtained for 1,4-dioxane. Although the interaction enthalpies of 18-crown-6 correlate well with those of 1,4-dioxane, the magnitude of the most relevant parameters, pi* and beta, is almost three times higher for 18-crown-6. This is rationalized in terms of the impact of the solute's volume in the solution processes of both compounds. (C) 2015 Elsevier B.V. All rights reserved.
Resumo:
Coffee silverskin is a major roasting by-product that could be valued as a source of antioxidant compounds. The effect of the major variables (solvent polarity, temperature and extraction time) affecting the extraction yields of bioactive compounds and antioxidant activity of silverskin extracts was evaluated. The extracts composition varied significantly with the extraction conditions used. A factorial experimental design showed that the use of a hydroalcoholic solvent (50%:50%) at 40 °C for 60 min is a sustainable option to maximize the extraction yield of bioactive compounds and the antioxidant capacity of extracts. Using this set of conditions it was possible to obtain extracts containing total phenolics (302.5 ± 7.1 mg GAE/L), tannins (0.43 ± 0.06 mg TAE/L), and flavonoids (83.0 ± 1.4 mg ECE/L), exhibiting DPPHradical dot scavenging activity (326.0 ± 5.7 mg TE/L) and ferric reducing antioxidant power (1791.9 ± 126.3 mg SFE/L). These conditions allowed, in comparison with other “more effective” for some individual parameters, a cost reduction, saving time and energy.
Resumo:
The fractal geometry is used to model of a naturally fractured reservoir and the concept of fractional derivative is applied to the diffusion equation to incorporate the history of fluid flow in naturally fractured reservoirs. The resulting fractally fractional diffusion (FFD) equation is solved analytically in the Laplace space for three outer boundary conditions. The analytical solutions are used to analyze the response of a naturally fractured reservoir considering the anomalous behavior of oil production. Several synthetic examples are provided to illustrate the methodology proposed in this work and to explain the diffusion process in fractally fractured systems.
Resumo:
A Dot-ELISA using a measles virus (MV) antigen obtained by sodium deoxycholate treatment was standardized and evaluated for IgM and IgG antibody detection in measles patients and measles-vaccinated subjects. A total of 192 serum samples were studied, comprising 47 from patients with acute and convalescent measles, 55 from 9-month old children prior to measles vaccination and 41 from children of the same age after vaccination, and 49 from patients with unrelated diseases. The diagnostic performances of the IgG Dot-ELISA and IgG immuno fluorescence test (IFT) were found to be close, varying from 0.97 to 1.00 in sensitivity and the specificities were maximum (1.00). Nevertheless, the sensitivity of the IgM Dot-ELISA (0.85) was higher than that (0.63) of the IgM IFT, although both assays had comparably high (1.00) specificities. The IgM Dot-ELISA in particular proved to be more sensitive in relation to other assays studied by revealing antibodies in 80.0% (12/15) of vaccinated children on the 15th day after immunization. In contrast the IgM IFT, failed to detect antibodies in the same group of vaccinated children. The stability of the MV antigen was longer than that of the IFT antigen, and the reproducibility of the Dot-Elisa was satisfactory.
Resumo:
This work intends to evaluate the (mechanical and durability) performance of concrete made with coarse recycled concrete aggregates (CRCA) obtained using two crushing processes: primary crushing (PC) and primary plus secondary crushing (PSC). This analysis intends to select the most efficient production process of recycled aggregates (RA). The RA used here resulted from precast products (P), with strength classes of 20 MPa, 45 MPa and 65 MPa, and from laboratory-made concrete (L) with the same compressive strengths. The evaluation of concrete was made with the following tests: compressive strength; splitting tensile strength; modulus of elasticity; carbona-tion resistance; chloride penetration resistance; capillary water absorption; and water absorption by immersion. These findings contribute to a solid and innovative basis that allows the precasting industry to use without restrictions the waste it generates. © (2015) Trans Tech Publications, Switzerland.
Resumo:
Dissertation presented to obtain a Ph.D. degree in Engineering and Technology Sciences, Biotechnology at the Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa
Resumo:
ISO 14001 is an International Standard of worldwide acceptance based on the concept that better environmental performance can be achieved when environmental aspects are systematically identified and managed giving a major contribution to Sustainability, through pollution prevention, improved environmental performance and complying with applicable laws. This paper aims to discuss the Sustainability approach through the use of Environmental Management Standards (EMS), the results achieved by organizations that implement and certify those EMS and a special focus on the current process of ISO 14001:2015 revision and the logic behind it.
Resumo:
The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) for the detection of circulating antigens from toxic components of Tityus serrulatus scorpion venom was determined in patients stung by T. serrulatus before antivenom administration. Thirty-seven patients were classified as mild cases and 19 as moderate or severe cases. The control absorbance in the venom assay was provided by serum samples from 100 individuals of same socioeconomic group and geographical area who had never been stung by scorpions or treated with horse antisera. The negative cutoff value (mean + 2 SD) corresponded to a venom concentration of 4.8 ng/ml. Three out of the 100 normal sera were positive, resulting in a specificity of 97%. The sensitivity of the ELISA when all cases of scorpion sting were included was 39.3%. When mild cases were excluded, the sensitivity increased to 94.7%. This study showed that this ELISA can be used for the detection of circulating venom toxic antigens in patients with systemic manifestations following. T. serrulatus sting but cannot be used for clinical studies in mild cases of envenoming since the test does not discriminate mild cases from control patients.
Resumo:
O presente trabalho de dissertação teve como objetivo a implementação de metodologias de Lean Management e avaliação do seu impacto no processo de Desenvolvimento de Produto. A abordagem utilizada consistiu em efetuar uma revisão da literatura e levantamento do Estado da Arte para obter a fundamentação teórica necessária à implementação de metodologias Lean. Prosseguiu com o levantamento da situação inicial da organização em estudo ao nível das atividades de desenvolvimento de produto, práticas de gestão documental e operacional e ainda de atividades de suporte através da realização de inquéritos e medições experimentais. Este conhecimento permitiu criar um modelo de referência para a implementação de Lean Management nesta área específica do desenvolvimento de produto. Após implementado, este modelo foi validado pela sua experimentação prática e recolha de indicadores. A implementação deste modelo de referência permitiu introduzir na Unidade de Desenvolvimento de Produto e Sistemas (DPS) da organização INEGI, as bases do pensamento Lean, contribuindo para a criação de um ambiente de Respeito pela Humanidade e de Melhoria Contínua. Neste ambiente foi possível obter ganhos qualitativos e quantitativos nas várias áreas em estudo, contribuindo de forma global para um aumento da eficiência e eficácia da DPS. Prevê-se que este aumento de eficiência represente um aumento da capacidade instalada na Organização, pela redução anual de 2290 horas de desperdício (6.5% da capacidade total da unidade) e pela redução significativa em custos operacionais. Algumas das implementações de melhoria propostas no decorrer deste trabalho, após verificado o seu sucesso, extravasaram a unidade em estudo e foram aplicadas transversalmente à da organização. Foram também obtidos ganhos qualitativos, tais como a normalização de práticas de gestão documental e a centralização e agilização de fluxos de informação. Isso permitiu um aumento de qualidade dos serviços prestados pela redução de correções e retrabalho. Adicionalmente, com o desenvolvimento de uma nova ferramenta que permite a monitorização do estado atual dos projetos a nível da sua percentagem de execução (cumprimento de objetivos), prazos e custos, bem como a estimação das datas de conclusão dos projetos possibilitando o replaneamento do projeto bem como a detecção atempada de desvios. A ferramenta permite também a criação de um histórico que identifica o esforço horário associado à realização das atividades/tarefas das várias áreas de Desenvolvimento de Produto e desta forma pode ser usada como suporte à orçamentação futura de atividades similares. No decorrer do projeto, foram também criados os mecanismos que permitem o cálculo de indicadores das competências técnicas e motivações intrínsecas individuais da equipa DPS. Estes indicadores podem ser usados na definição por parte dos gestores dos projetos da composição das equipas de trabalho, dos executantes de tarefas individuais do projeto e dos destinatários de ações de formação. Com esta informação é expectável que se consiga um maior aproveitamento do potencial humano e como consequência um aumento do desempenho e da satisfação pessoal dos recursos humanos da organização. Este caso de estudo veio demonstrar que o potencial de melhoria dos processos associados ao desenvolvimento de produto através de metodologias de Lean Management é muito significativo, e que estes resultam em ganhos visíveis para a organização bem como para os seus elementos individualmente.
Resumo:
We address a real world scheduling problem concerning the repair process of aircrafts’ engines by TAP - Maintenance & Engineering (TAP-ME). TAP-ME is the maintenance, repair and overhaul organization of TAP Portugal, Portugal’s leading airline, which employs about 4000 persons to provide maintenance and engineering services in aircraft, engines and components. TAP-ME is aiming to optimize its maintenance services, focusing on the reduction of the engines repair turnaround time.
Resumo:
In this talk, we discuss a scheduling problem that originated at TAP - Maintenance & Engineering - the maintenance, repair and overhaul organization of Portugal’s leading airline. In the repair process of aircrafts’ engines, the operations to be scheduled may be executed on a certain workstation by any processor of a given set, and the objective is to minimize the total weighted tardiness. A mixed integer linear programming formulation, based on the flexible job shop scheduling, is presented here, along with computational experiment on a real instance, provided by TAP-ME, from a regular working week. The model was also tested using benchmarking instances available in literature.
Resumo:
Dissertação apresentada para a obtenção do Grau de Doutor em Informática