999 resultados para Oxygen -- Measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This investigation aimed to elucidate the relative roles of putative brevetoxins, reactive oxygen species and free fatty acids as the toxic principle of the raphidophyte Chattonella marina, using damselfish as the bioassay. Our investigations on Australian C. marina demonstrated an absence or only very low concentrations of brevetoxin-like compounds by radio-receptor binding assay and liquid chromatography-mass spectroscopy techniques. Chattonella is unique in its ability to produce levels of reactive oxygen species 100 times higher than most other algal species. However, high levels of superoxide on their own were found not to cause fish mortalities. Lipid analysis revealed this raphidophyte to contain high concentrations of the polyunsaturated fatty acid eicosapentaenoic acid (EPA; 18-23% of fatty acids), which has demonstrated toxic properties to marine organisms. Using damselfish as a model organism, we demonstrated that the free fatty acid (FFA) form of EPA produced a mortality and fish behavioural response similar to fish exposed to C. marina cells. This effect was not apparent when fish were exposed to other lipid fractions including a triglyceride containing fish oil, docosahexaenoate-enriched ethyl ester, or pure brevetoxin standards. The presence of superoxide together with low concentrations of EPA accelerated fish mortality rate threefold. We conclude that the enhancement of ichthyotoxicity of EPA in the presence of superoxide can account for the high C. marina fish killing potential. (C) 2003 Elsevier B.V All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two methods were compared for determining the concentration of penetrative biomass during growth of Rhizopus oligosporus on an artificial solid substrate consisting of an inert gel and starch as the sole source of carbon and energy. The first method was based on the use of a hand microtome to make sections of approximately 0.2- to 0.4-mm thickness parallel to the substrate surface and the determination of the glucosamine content in each slice. Use of glucosamine measurements to estimate biomass concentrations was shown to be problematic due to the large variations in glucosamine content with mycelial age. The second method was a novel method based on the use of confocal scanning laser microscopy to estimate the fractional volume occupied by the biomass. Although it is not simple to translate fractional volumes into dry weights of hyphae due to the lack of experimentally determined conversion factors, measurement of the fractional volumes in themselves is useful for characterizing fungal penetration into the substrate. Growth of penetrative biomass in the artificial model substrate showed two forms of growth with an indistinct mass in the region close to the substrate surface and a few hyphae penetrating perpendicularly to the surface in regions further away from the substrate surface. The biomass profiles against depth obtained from the confocal microscopy showed two linear regions on log-linear plots, which are possibly related to different oxygen availability at different depths within the substrate. Confocal microscopy has the potential to be a powerful tool in the investigation of fungal growth mechanisms in solid-state fermentation. (C) 2003 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: Muito embora os estudos apontem para um efeito positivo do exercício físico, em especial o treinamento com exercício aeróbio, sobre a pressão arterial e a distensibilidade arterial, pouco se sabe sobre os efeitos do treinamento com exercício de resistência aeróbia sobre a complacência vascular de indivíduos jovens saudáveis. Objetivos: Avaliar o efeito de 16 semanas de treinamento de resistência aeróbia sobre a função vascular e a pressão arterial de indivíduos jovens sedentários. Métodos: Foram avaliados 56 voluntários (de ambos os sexos, na faixa etária de 18 à 29 anos) antes e após 16 semanas de treinamento com corrida 3 vezes por semana. As medidas de pressão arterial foram realizadas de acordo com a VI Diretrizes Brasileiras de Hipertensão e a velocidade de onda de pulso (VOP) foi realizada com a utilização de um gravador automático computadorizado e os resultados foram analisados pelo programa Complior®. Resultados: Dos 56 indivíduos que participaram do presente estudo, 44 eram do sexo masculino (78,5%) e 12 do sexo feminino (21,5 %). Eles apresentaram idade de 22 ± 3 anos, estatura de 1,75 ± 0,07 metros, circunferência de cintura de 79,6 ± 7,8 cm e PAM de 79 ± 6,4 mmHg. O treinamento promoveu redução da FC repouso (69 ± 7,0 vs. 61 ± 7,1; p<0,05) e aumento do VO2pico (43,3 ± 7,3 vs. 50,1 ± 7,2; p<0,05). Entretanto, pressão arterial sistólica (107 ± 9,4 vs. 110 ± 10), pressão arterial diastólica (63 ± 5,7 vs. 62 ± 5,5), pressão de pulso (44 ± 7,0 vs. 48 ± 7,0) e VOP (6,5 ± 1,1 vs. 6,5 ± 1,1) não apresentaram alteração após o treinamento físico (p>0,05). Conclusões: Podemos concluir que 16 semanas de treinamento de resistência aeróbia foram capazes de aumentar a aptidão cardiorrespiratória, porém não provocaram alterações sobre a velocidade de onda de pulso e pressão arterial em voluntários saudáveis e sedentários. Sugere-se que a ausência de adaptações vasculares após o treinamento seja devido às características da amostra – indivíduos jovens e saudáveis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance measurement of police services is complicated by ambiguous and complex goal- and objectives-setting, and by the difficulties of measuring outputs. This article looks at the organizational and management changes being made in Portuguese police forces. The authors fill a gap in the literature on performance measurement in Portugal by taking a national approach to the study of how law enforcement agencies are introducing new management accounting changes. The article therefore widens the debate on performance measurement and performance improvements in law enforcement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Websites are, nowadays, the face of institutions, but they are often neglected, especially when it comes to contents. In the present paper, we put forth an investigation work whose final goal is the development of a model for the measurement of data quality in institutional websites for health units. To that end, we have carried out a bibliographic review of the available approaches for the evaluation of website content quality, in order to identify the most recurrent dimensions and the attributes, and we are currently carrying out a Delphi Method process, presently in its second stage, with the purpose of reaching an adequate set of attributes for the measurement of content quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many public organisations have been under great pressure in recent years to increase the efficiency and transparency of outputs, to rationalise the use of public resources, and to increase the quality of service delivery. In this context, public organisations were encouraged to introduce the New Public Management reforms with the goal of improving the efficiency and effectiveness of the performance organisation through a new public management model. This new public management model is based on measurement by outputs and outcomes, a clear definition of responsibilities, the transparency and accountability of governmental activities, and on a greater value for citizens. What type of performance measurement systems are used in police services? Based on the literature, we see that multidimensional models, such as the Balanced Scorecard, are important in many public organisations, like municipalities, universities, and hospitals. Police services are characterised by complex, diverse objectives and stakeholders. Therefore, performance measurement of these public services calls for a specific analysis. Based on a nationwide survey of all police chiefs of the Portuguese police force, we find that employee performance measurement is the main form of measurement. Also, we propose a strategic map for the Portuguese police service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to obtain evidence on the size of the impact of the Hong Kong/68 variant of influenza A2 virus on the population of São Paulo, Brazil, serum samples taken in 1967 before this variant appeared and during successive years after it appeared were examined for their antibody content. Haemagglutination-inhibition tests performed on a total of 2726 serum samples from adults showed a sharp decrease in 1969 of the proportion of sera without antibody to the Hong Kong/68 variant and a corresponding mercase in the proportion with high titres. It was concluded that about three-quarters of the adult population became infected at some time after the variant appeared, the majority in the first year of prevalence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of Social Responsibility (SR) is higher if this business variable is related with other ones of strategic nature in business activity (competitive success that the company achieved, performance that the firms develop and innovations that they carries out). The hypothesis is that organizations that focus on SR are those who get higher outputs and innovate more, achieving greater competitive success. A scale for measuring the orientation to SR has defined in order to determine the degree of relationship between above elements. This instrument is original because previous scales do not exist in the literature which could measure, on the one hand, the three classics sub-constructs theoretically accepted that SR is made up and, on the other hand, the relationship between SR and the other variables. As a result of causal relationships analysis we conclude with a scale of 21 indicators, validated scale with a sample of firms belonging to the Autonomous Community of Extremadura and it is the first empirical validation of these dimensions we know so far, in this context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the photodiode capacitance dependence on imposed light and applied voltage using different devices. The first device is a double amorphous silicon pin-pin photodiode; the second one a crystalline pin diode and the last one a single pin amorphous silicon diode. Double amorphous silicon diodes can be used as (de)multiplexer devices for optical communications. For short range applications, using plastic optical fibres, the WDM (wavelength-division multiplexing) technique can be used in the visible light range to encode multiple signals. Experimental results consist on measurements of the photodiode capacitance under different conditions of imposed light and applied voltage. The relation between the capacitive effects of the double diode and the quality of the semiconductor internal junction will be analysed. The dynamics of charge accumulations will be measured when the photodiode is illuminated by a pulsed monochromatic light.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asthma is a chronic inflammatory disorder of the respiratory airways affecting people of all ages, and constitutes a serious public health problem worldwide (6). Such a chronic inflammation is invariably associated with injury and repair of the bronchial epithelium known as remodelling (11). Inflammation, remodelling, and altered neural control of the airways are responsible for both recurrent exacerbations of asthma and increasingly permanent airflow obstruction (11, 29, 34). Excessive airway narrowing is caused by altered smooth muscle behaviour, in close interaction with swelling of the airway walls, parenchyma retractile forces, and enhanced intraluminal secretions (29, 38). All these functional and structural changes are associated with the characteristic symptoms of asthma – cough, chest tightness, and wheezing –and have a significant impact on patients’ daily lives, on their families and also on society (1, 24, 29). Recent epidemiological studies show an increase in the prevalence of asthma, mainly in industrial countries (12, 25, 37). The reasons for this increase may depend on host factors (e.g., genetic disposition) or on environmental factors like air pollution or contact with allergens (6, 22, 29). Physical exercise is probably the most common trigger for brief episodes of symptoms, and is assumed to induce airflow limitations in most asthmatic children and young adults (16, 24, 29, 33). Exercise-induced asthma (EIA) is defined as an intermittent narrowing of the airways, generally associated with respiratory symptoms (chest tightness, cough, wheezing and dyspnoea), occurring after 3 to 10 minutes of vigorous exercise with a maximal severity during 5 to 15 minutes after the end of the exercise (9, 14, 16, 24, 33). The definitive diagnosis of EIA is confirmed by the measurement of pre- and post-exercise expiratory flows documenting either a 15% fall in the forced expiratory volume in 1 second (FEV1), or a ≥15 to 20% fall in peak expiratory flow (PEF) (9, 24, 29). Some types of physical exercise have been associated with the occurrence of bronchial symptoms and asthma (5, 15, 17). For instance, demanding activities such as basketball or soccer could cause more severe attacks than less vigorous ones such as baseball or jogging (33). The mechanisms of exercise-induced airflow limitations seem to be related to changes in the respiratory mucosa induced by hyperventilation (9, 29). The heat loss from the airways during exercise, and possibly its post-exercise rewarming may contribute to the exercise-induced bronchoconstriction (EIB) (27). Additionally, the concomitant dehydration from the respiratory mucosa during exercise leads to an increased interstitial osmolarity, which may also contribute to bronchoconstriction (4, 36). So, the risk of EIB in asthmatically predisposed subjects seems to be higher with greater ventilation rates and the cooler and drier the inspired air is (23). The incidence of EIA in physically demanding coldweather sports like competitive figure skating and ice hockey has been found to occur in up to 30 to 35% of the participants (32). In contrast, swimming is often recommended to asthmatic individuals, because it improves the functionality of respiratory muscles and, moreover, it seems to have a concomitant beneficial effect on the prevalence of asthma exacerbations (14, 26), supporting the idea that the risk of EIB would be smaller in warm and humid environments. This topic, however, remains controversial since the chlorified water of swimming pools has been suspected as a potential trigger factor for some asthmatic patients (7, 8, 20, 21). In fact, the higher asthma incidence observed in industrialised countries has recently been linked to the exposition to chloride (7, 8, 30). Although clinical and epidemiological data suggest an influence of humidity and temperature of the inspired air on the bronchial response of asthmatic subjects during exercise, some of those studies did not accurately control the intensity of the exercise (2, 13), raising speculation of whether the experienced exercise overload was comparable for all subjects. Additionally, most of the studies did not include a control group (2, 10, 19, 39), which may lead to doubts about whether asthma per se has conditioned the observed results. Moreover, since the main targeted age group of these studies has been adults (10, 19, 39), any extrapolation to childhood/adolescence might be questionable regarding the different lung maturation. Considering the higher incidence of asthma in youngsters (30) and the fact that only the works of Amirav and coworkers (2, 3) have focused on this age group, a scarcity of scientific data can be identified. Additionally, since the main environmental trigger factors, i.e., temperature and humidity, were tested separately (10, 28, 39) it would be useful to analyse these two variables simultaneously because of their synergic effect on water and heat loss by the airways (31, 33). It also appears important to estimate the airway responsiveness to exercise within moderate environmental ranges of temperature and humidity, trying to avoid extreme temperatures and humidity conditions used by others (2, 3). So, the aim of this study was to analyse the influence of moderate changes in air temperature and humidity simultaneously on the acute ventilatory response to exercise in asthmatic children. To overcome the above referred to methodological limitations, we used a 15 minute progressive exercise trial on a cycle ergometer at 3 different workload intensities, and we collected data related to heart rate, respiratory quotient, minute ventilation and oxygen uptake in order to ensure that physiological exercise repercussions were the same in both environments. The tests were done in a “normal” climatic environment (in a gymnasium) and in a hot and humid environment (swimming pool); for the latter, direct chloride exposition was avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: A cirurgia abdominal acarreta grande risco de complicações pulmonares pós-operatórias. As alterações pós-cirúrgicas abdominais, reflectem-se na dinâmica ventilatória, de modo particular nos volumes e capacidades pulmonares, e na capacidade de tosse. Objectivos: Compreender qual a variação dos volumes e capacidades pulmonares e da capacidade de tosse antes e depois da cirurgia abdominal (estômago e cólon), e qual a correlação dessa variação com o nível de dor percepcionada. Desenho do estudo: Unicêntrico, prospectivo e observacional. Amostra: 10 indivíduos, propostos para cirurgia abdominal – estômago e cólon. Metodologia: Dois momentos de avaliação: um nas 24h préoperatórias em que se mediu a capacidade vital forçada (CVF) e o volume expirado máximo no primeiro segundo (VEMS1) com espirometria, e do pico de fluxo de tosse (PCF); e um segundo momento nas 24h pós-operatórias onde se repetiram as medições do primeiro momento com o acréscimo da avaliação da dor. Resultados: No pós-operatorio imediato há uma diminuição significativa da CVF de 44,30%±17,24 (p=0,005), do VEMS1 de 35,50%±28,47 (p=0,009) e do PCF de 38,97%±38,66 (p=0,012). Não se verificou nenhuma relação entre a dor percepcionada na realização das manobras de espirometria e tosse com diminuição a da CVF e do VEMS1 e do PCF respectivamente. O sexo apresentou uma relação significativa com a variação da CRF e do VEMS1 (p=0,046 e p=0,008 respectivamente). A frequência respiratória apresentou um aumento significativo no pós-operatório de 10±11,22 cpm (p=0,019). A saturação periférica de oxigénio apresentou uma diminuição significativa no pós-operatório de 3,52±2,47 (p=0,011) Conclusão: No estudo efectuado fica demonstrado o impacto negativo da cirurgia abdominal na dinâmica respiratória. A diminuição dos valores da CVF, do VEMS1 e do PCF podem contribuir de forma significativa para o aumento do risco de complicações respiratória pós-operatórias. No entanto seria importante a realização deste estudo com uma amostra maior.