991 resultados para Medical Implants
Resumo:
This study sought to assess the extent to which the entry characteristics of students in a graduate-entry medical programme predict the subsequent development of clinical reasoning ability. Subjects comprised 290 students voluntarily recruited from three successive cohorts of the University of Queensland's MBBS Programme. Clinical reasoning was measured once a year over a period of three years using two methods, a set of 10 Clinical Reasoning Problems (CRPs) and the Diagnostic Thinking Inventory (DTI). Data on gender, age at entry into the programme, nature of primary degree, scores on selection criteria (written examination plus interview) and academic performance in the first two years of the programme were recorded for each student, and their association with clinical reasoning skill analysed using univariate and multivariate analysis. Univariate analysis indicated significant associations between CRP score, gender and primary degree with a significant but small association between DTI and interview score. Stage of progression through the programme was also an important predictor of performance on both indicators. Subsequent multivariate analysis suggested that female gender is a positive predictor of CRP score independently of the nature of a subject's primary degree and stage of progression through the programme, although these latter two variables are interdependent. Positive predictors of clinical reasoning skill are stage of progression through the MBBS programme, female gender and interview score. Although the nature of a student's primary degree is important in the early years of the programme, evidence suggests that by graduation differences between students' clinical reasoning skill due to this factor have been resolved.
Resumo:
Objective: To evaluate the feasibility, reliability and acceptability of the mini clinical evaluation exercise (mini-CEX) for performance assessment among international medical graduates (IMGs). Design, setting and participants: Observational study of 209 patient encounters involving 28 IMGs and 35 examiners at three metropolitan teaching hospitals in New South Wales, Victoria and Queensland, September-December 2006. Main outcome measures: The reliability of the mini-CEX was estimated using generatisability (G) analysis, and its acceptability was evaluated by a written survey of the examiners and IMGs. Results: The G coefficient for eight encounters was 0.88, suggesting that the reliability of the mini-CEX was 0.90 for 10 encounters. Almost half of the IMGs (7/16) and most examiners (14/18) were satisfied with the mini-CEX as a learning tool. Most of the IMGs and examiners enjoyed the immediate feedback, which is a strong component of the tool. Conclusion: The mini-CEX is a reliable tool for performance assessment of IMGs, and is acceptable to and well received by both learners and supervisors.
Resumo:
In the recent time CFD tools have become increasingly useful in the engineering design studies especially in the area of aerospace vehicles. This is largely due to the advent of high speed computing platforms in addition to the development of new efficient algorithms. The algorithms based on kinetic schemes have been shown to be very robust and further meshless methods offer certain advantages over the other methods. Preliminary investigations of blood flow visualization through artery using CFD tool have shown encouraging results which further needs to be verified and validated.
Resumo:
Aims: To examine the characteristics, incidence, treatment and outcome of presumed opioid, γ-hydroxybutyrate (GHB) and γ-butyrolactone (GBL) overdoses involving users of illicit drugs in Helsinki. GHB/GBL were included in this study, despite not being opioids, due to the relative ease with which they can cause potentially fatal respiratory depression. The incidence and time interval of recurrent opioid toxicity after prehospital administration of naloxone, an opioid antagonist, was studied in presumed heroin overdose patients. Naloxone has been reported to have many adverse effects and the effects of naloxone administered during an opioid overdose on the cardiovascular system and catecholamine levels in piglets were studied. Materials and methods: Patients included in these published retrospective studies were from the following time periods: Study I: 1995-2002, II: 1997-2000, III: 1995-2000, V: 2006-2007. Presumed opioid overdose patients were examined in studies I, II and III. GHB/GBL overdoses among injecting drug users was examined in study V. Recurrent opioid toxicity after prehospital naloxone administration in heroin overdose patients was examined in study III. The effects of naloxone (80 μg/kg i.v.) on the cardiovascular system and catecholamine levels administered during morphine overdose (8mg/kg i.v.) and under propofol anesthesia with spontaneous breathing were studied in eight piglets (IV). In this thesis, previously unpublished data on the incidence of opioid overdose between 2001-2007 and comparison of the characteristics of buprenorphine and heroin overdose patients encountered in 1995-2005 are also included. Results: Helsinki Emergency Medical Service (EMS) ambulances were dispatched annually to 34,153- 45,118 calls from 1995 to 2007. Of them, 7-8% were coded as intoxications or overdoses. During this time, 436 patients were treated by the EMS for presumed opioid overdose. The peak incidence of opioid overdoses was in the year 2000 (113 cases), after which they declined to 6-26 cases annually. The annual incidence of buprenorphine related overdoses increased from 4 (4% of opioid overdoses) in the year 2000 to 8 (30% of opioid overdoses) in 2007. The annual number of GHB related overdose patients treated by Helsinki EMS increased from 21 to 73 between 2004-2007. There appeared to be a peak in the incidence of both GHB/GBL and opioid related overdoses on Saturdays. Characteristics of opioid overdose patients The median age of opioid overdose patients was 28 years (22;33, 25- and 75-percentiles), and 84% were male. Buprenorphine overdose patients had more polydrug, such as alcohol and/or benzodiazepines, use in comparison with heroin overdose patients, 70% versus 33%, respectively. Severe respiratory depression was reported less often with buprenorphine overdoses compared to heroin overdoses, in 67.0% versus 85.4%, respectively. Outcome of heroin overdose patients with cardiac arrest Ninety four patients suffered cardiac arrest due to acute drug poisoning/overdose and were thus considered for resuscitation. Resuscitation was attempted in 72 cases. Cardiac arrest was caused by heroin overdose for 19 patients of which three (16%) were discharged alive. Other agents also induced cardiac arrest in 53 patients, of which six (11%) were discharged alive. The arrest was either EMS witnessed or occurring after the emergency call for all survivors of heroin induced cardiac arrest. Characteristics of GHB/GBL overdose patients The records of 100 GHB/GBL related overdose patients from 2006-2007 were retrieved. The median age of GHB/GBL overdose patients encountered on weekend nights was 24 years (22;27, 25- and 75-percentiles) and 49% were male. Polydrug use was reported in 62-80% of the cases. Thirty nine patients were encountered on Friday-Saturday or Saturday-Sunday night between 11 pm-6 am. The remaining sixty one patients were outside this time frame. There was a statistically significant difference between these two groups in history of chronic injecting drug use (33% vs. 59%, respectively, p=0.012). Recurrent heroin toxicity after prehospital naloxone administration Study III included 145 presumed heroin overdose patients. After prehospital care, 84 patients refused further care and were not transported to an Emergency Department (ED). Seventy one (85%) of them were administered naloxone by the EMS. During a 12-h follow up period, none of these patients developed severe recurrent opioid toxicity. The remaining 61 patients were transported to an ED. Prior to transportation, 52 (85%) patients were administered naloxone by the EMS. Fifteen of them were administered naloxone also in the ED and recurrent opioid toxicity was evident either on arrival at the ED or shortly thereafter. Prehospital naloxone was administered either intravenously, intramuscularly (i.m.) or subcutaneously (s.c.). There was a tendency for more frequent recurrent heroin toxicity among the patients with only intravenous administration of prehospital naloxone (13/36) compared with the patients with intramuscular or subcutaneous prehospital naloxone (2/16), p=0.106. The effects of naloxone on the cardiovascular system and catecholamine levels in piglets The administration of morphine to piglets resulted in an obvious respiratory depression, which was reversed by naloxone. Two severely hypoxemic piglets developed cardiac arrest after naloxone administration. In the other six animals, the administration of naloxone did not provoke arrhythmias, cardiac ischemia or visible evidence of pulmonary edema. There was a statistically significant (p=0.012) increase in norepinephrine levels after morphine administration and before naloxone administration: from 1.9 (1.3-2.3) ng/ml at baseline, to 31.7 (8.3-83.0) ng/ml (median, 25 and 75 percentiles parentheses) after morphine administration. After the administration of naloxone, the catecholamine levels continued to increase in only one of the animals. Conclusions: The incidence of buprenorphine related overdoses increased during the study period, but was still lower in comparison to those involving heroin. Injecting drug users have also started to use GHB/GBL. While recreational drug users use GHB/GBL during weekend nights, a GHB/GBL overdose patient encounter during weekdays has a more probable history of injecting drug use. Patients with cardiac arrest after heroin overdose have a poor prognosis. It appears to be safe to leave heroin overdose patients on scene after prehospital treatment with naloxone. Although no statistically significant difference was observed, it seems prudent to administer part of the total naloxone dose s.c. or i.m. to reduce the risk of recurrent respiratory depression. If transported to an ED, an observation period of one to two hours after the last naloxone dose seems adequate. The treating physician must be vigilant, however, due to the high prevalence of polydrug use and high morbidity after non fatal heroin overdose. Furthermore, care should be taken regarding possible chronic disorders and drug rehabilitation should be addressed. In the experimental animal study, two animals developed cardiac arrest after receiving naloxone while in hypoxemia and bradycardia. Further studies are required to assess the effect of naloxone during opioid-induced hypercapnia and hypoxemia in animals addicted to opioids.
Resumo:
The habit of "drinking smoke" , meaning tobacco smoking, caused a true controversy in early modern England. The new substance was used both for its alleged therapeutic properties as well as its narcotic effects. The dispute over tobacco continues the line of written controversies which were an important means of communication in the sixteenth and seventeenth century Europe. The tobacco controversy is special among medical controversies because the recreational use of tobacco soon spread and outweighed its medicinal use, ultimately causing a social and cultural crisis in England. This study examines how language is used in polemic discourse and argumentation. The material consists of medical texts arguing for and against tobacco in early modern England. The texts were compiled into an electronic corpus of tobacco texts (1577 1670) representing different genres and styles of writing. With the help of the corpus, the tobacco controversy is described and analyzed in the context of early modern medicine. A variety of methods suitable for the study of conflict discourse were used to assess internal and external text variation. The linguistic features examined include personal pronouns, intertextuality, structural components, and statistically derived keywords. A common thread in the work is persuasive language use manifested, for example, in the form of emotive adjectives and the generic use of pronouns; the latter is especially pronounced in the dichotomy between us and them. Controversies have not been studied in this manner before but the methods applied have supplemented each other and proven their suitability in the study of conflictive discourse. These methods can also be applied to present-day materials.
Resumo:
Empirical research available on technology transfer initiatives is either North American or European. Literature over the last two decades shows various research objectives such as identifying the variables to be measured and statistical methods to be used in the context of studying university based technology transfer initiatives. AUTM survey data from years 1996 to 2008 provides insightful patterns about the North American technology transfer initiatives, we use this data in our paper. This paper has three sections namely, a comparison of North American Universities with (n=1129) and without Medical Schools (n=786), an analysis of the top 75th percentile of these samples and a DEA analysis of these samples. We use 20 variables. Researchers have attempted to classify university based technology transfer initiative variables into multi-stages, namely, disclosures, patents and license agreements. Using the same approach, however with minor variations, three stages are defined in this paper. The first stage is to do with inputs from R&D expenditure and outputs namely, invention disclosures. The second stage is to do with invention disclosures being the input and patents issued being the output. The third stage is to do with patents issued as an input and technology transfers as outcomes.
Resumo:
Electrical Impedance Tomography (EIT) is a computerized medical imaging technique which reconstructs the electrical impedance images of a domain under test from the boundary voltage-current data measured by an EIT electronic instrumentation using an image reconstruction algorithm. Being a computed tomography technique, EIT injects a constant current to the patient's body through the surface electrodes surrounding the domain to be imaged (Omega) and tries to calculate the spatial distribution of electrical conductivity or resistivity of the closed conducting domain using the potentials developed at the domain boundary (partial derivative Omega). Practical phantoms are essentially required to study, test and calibrate a medical EIT system for certifying the system before applying it on patients for diagnostic imaging. Therefore, the EIT phantoms are essentially required to generate boundary data for studying and assessing the instrumentation and inverse solvers a in EIT. For proper assessment of an inverse solver of a 2D EIT system, a perfect 2D practical phantom is required. As the practical phantoms are the assemblies of the objects with 3D geometries, the developing of a practical 2D-phantom is a great challenge and therefore, the boundary data generated from the practical phantoms with 3D geometry are found inappropriate for assessing a 2D inverse solver. Furthermore, the boundary data errors contributed by the instrumentation are also difficult to separate from the errors developed by the 3D phantoms. Hence, the errorless boundary data are found essential to assess the inverse solver in 2D EIT. In this direction, a MatLAB-based Virtual Phantom for 2D EIT (MatVP2DEIT) is developed to generate accurate boundary data for assessing the 2D-EIT inverse solvers and the image reconstruction accuracy. MatVP2DEIT is a MatLAB-based computer program which simulates a phantom in computer and generates the boundary potential data as the outputs by using the combinations of different phantom parameters as the inputs to the program. Phantom diameter, inhomogeneity geometry (shape, size and position), number of inhomogeneities, applied current magnitude, background resistivity, inhomogeneity resistivity all are set as the phantom variables which are provided as the input parameters to the MatVP2DEIT for simulating different phantom configurations. A constant current injection is simulated at the phantom boundary with different current injection protocols and boundary potential data are calculated. Boundary data sets are generated with different phantom configurations obtained with the different combinations of the phantom variables and the resistivity images are reconstructed using EIDORS. Boundary data of the virtual phantoms, containing inhomogeneities with complex geometries, are also generated for different current injection patterns using MatVP2DEIT and the resistivity imaging is studied. The effect of regularization method on the image reconstruction is also studied with the data generated by MatVP2DEIT. Resistivity images are evaluated by studying the resistivity parameters and contrast parameters estimated from the elemental resistivity profiles of the reconstructed phantom domain. Results show that the MatVP2DEIT generates accurate boundary data for different types of single or multiple objects which are efficient and accurate enough to reconstruct the resistivity images in EIDORS. The spatial resolution studies show that, the resistivity imaging conducted with the boundary data generated by MatVP2DEIT with 2048 elements, can reconstruct two circular inhomogeneities placed with a minimum distance (boundary to boundary) of 2 mm. It is also observed that, in MatVP2DEIT with 2048 elements, the boundary data generated for a phantom with a circular inhomogeneity of a diameter less than 7% of that of the phantom domain can produce resistivity images in EIDORS with a 1968 element mesh. Results also show that the MatVP2DEIT accurately generates the boundary data for neighbouring, opposite reference and trigonometric current patterns which are very suitable for resistivity reconstruction studies. MatVP2DEIT generated data are also found suitable for studying the effect of the different regularization methods on reconstruction process. Comparing the reconstructed image with an original geometry made in MatVP2DEIT, it would be easier to study the resistivity imaging procedures as well as the inverse solver performance. Using the proposed MatVP2DEIT software with modified domains, the cross sectional anatomy of a number of body parts can be simulated in PC and the impedance image reconstruction of human anatomy can be studied.
Resumo:
Mg and its alloys become natural biomaterials as the elemental Mg is found in the human body in abundance and their mechanical properties being akin to the natural bone as well as due to their inherent bioabsorbable/bioresorbable property. This paper discusses the development of new Mg alloys and their corrosion characteristics in detail. The latest advancements in coating of Mg alloys to control their degradation rate are also reviewed along with the future challenges that need to be addressed.
Resumo:
Fiber Bragg Grating (FBG) sensors have become one of the most widely used sensors in the recent times for a variety of applications in the fields of aerospace, civil, automotive, etc. It has been recently realized that FBGs and etched FBGs can play an important role in biomedical applications. This article provides a brief overview of the recent advancements in the application of FBG sensors in bio-mechanical, bio-sensing and bio-medical fields.
Resumo:
Understanding technology evolution through periodic landscaping is an important stage of strategic planning in R&D Management. In fields like that of healthcare, where the initial R&D investment is huge and good medical product serve patients better, these activities become crucial. Approximately five percentage of the world population has hearing disabilities. Current hearing aid products meet less than ten percent of the global needs. Patent data and classifications on cochlear implants from 1977-2010, show the landscapes and evolution in the area of such implant. We attempt to highlight emergence and disappearance of patent classes over period of time showing variations in cochlear implant technologies. A network analysis technique is used to explore and capture technology evolution in patent classes showing what emerged or disappeared over time. Dominant classes are identified. The sporadic influence of university research in cochlear implants is also discussed.
Resumo:
Unmet clinical needs remain the primary driving force for innovations in medical devices. While appropriate mechanisms to protect these innovative outcomes are essential, the performance of clinical trials to ensure safety is also mandated before the invention is ready for public use. Literature explaining the relationship between patenting activities and clinical trials of medical devices is scarce. Linking patent ownership to clinical trials may imply product leadership and value chain control. In this paper, we use patent data from Indian Patent Office (IPO), PCT, and data from Clinical Trials Registry of India (CTRI) to identify whether patent assignees have any role in leading as primary sponsors of clinical trials. A total of 42 primary sponsors are identified from the CTRI database in India. Number of patents awarded to these primary sponsors in the particular medical device, total number of patents awarded to the primary sponsor in all technologies, total number of patents in the specific medical device technology provides an indication of leadership and control in the value chain.