989 resultados para MOBILE RADIO
Resumo:
In this paper, we study how access pricing affects network competition when subscription demand is elastic and each network uses non-linear prices and can apply termination-based price discrimination. In the case of a fixed per minute termination charge, we find that a reduction of the termination charge below cost has two opposing effects: it softens competition but helps to internalize network externalities. The former reduces mobile penetration while the latter boosts it. We find that firms always prefer termination charge below cost for either motive while the regulator prefers termination below cost only when this boosts penetration. Next, we consider the retail benchmarking approach (Jeon and Hurkens, 2008) that determines termination charges as a function of retail prices and show that this approach allows the regulator to increase penetration without distorting call volumes.
Resumo:
STATEMENT OF PROBLEM: The difficulty of identifying the ownership of lost dentures when found is a common and expensive problem in long term care facilities (LTCFs) and hospitals. PURPOSE: The purpose of this study was to evaluate the reliability of using radiofrequency identification (RFID) in the identification of dentures for LTCF residents after 3 and 6 months. MATERIAL AND METHODS: Thirty-eight residents of 2 LTCFs in Switzerland agreed to participate after providing informed consent. The tag was programmed with the family and first names of the participants and then inserted in the dentures. After placement of the tag, the information was read. A second and third assessment to review the functioning of the tag occurred at 3 and 6 months, and defective tags (if present) were reported and replaced. The data were analyzed with descriptive statistics. RESULTS: At the 3-month assessment of 34 residents (63 tags) 1 tag was unreadable and 62 tags (98.2%) were operational. At 6 months, the tags of 27 of the enrolled residents (50 tags) were available for review. No examined tag was defective at this time period. CONCLUSIONS: Within the limits of this study (number of patients, 6-month time span) RFID appears to be a reliable method of tracking and identifying dentures, with only 1 of 65 devices being unreadable at 3 months and 100% of 50 initially placed tags being readable at the end of the trial.
Resumo:
We re-examine the literature on mobile termination in the presence of network externalities. Externalities arise when firms discriminate between on- and off-net calls or when subscription demand is elastic. This literature predicts that profit decreases and consumer surplus increases in termination charge in a neighborhood of termination cost. This creates a puzzle since in reality we see regulators worldwide pushing termination rates down while being opposed by network operators. We show that this puzzle is resolved when consumers' expectations are assumed passive but required to be fulfilled in equilibrium (as defined by Katz and Shapiro, AER 1985), instead of being rationally responsive to non-equilibrium prices, as assumed until now.
Resumo:
AIMS: Patients with well-tolerated sustained monomorphic ventricular tachycardia (SMVT) and left ventricular ejection fraction (LVEF) over 30% may benefit from a primary strategy of VT ablation without immediate need for a 'back-up' implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: One hundred and sixty-six patients with structural heart disease (SHD), LVEF over 30%, and well-tolerated SMVT (no syncope) underwent primary radiofrequency ablation without ICD implantation at eight European centres. There were 139 men (84%) with mean age 62 ± 15 years and mean LVEF of 50 ± 10%. Fifty-five percent had ischaemic heart disease, 19% non-ischaemic cardiomyopathy, and 12% arrhythmogenic right ventricular cardiomyopathy. Three hundred seventy-eight similar patients were implanted with an ICD during the same period and serve as a control group. All-cause mortality was 12% (20 patients) over a mean follow-up of 32 ± 27 months. Eight patients (40%) died from non-cardiovascular causes, 8 (40%) died from non-arrhythmic cardiovascular causes, and 4 (20%) died suddenly (SD) (2.4% of the population). All-cause mortality in the control group was 12%. Twenty-seven patients (16%) had a non-fatal recurrence at a median time of 5 months, while 20 patients (12%) required an ICD, of whom 4 died (20%). CONCLUSION: Patients with well-tolerated SMVT, SHD, and LVEF > 30% undergoing primary VT ablation without a back-up ICD had a very low rate of arrhythmic death and recurrences were generally non-fatal. These data would support a randomized clinical trial comparing this approach with others incorporating implantation of an ICD as a primary strategy.
Resumo:
Es presenta un estudi de l’avaluació dels resultats en el tractament de les fractures distals de radi durant el període de temps 2008-2010 a l’Hospital Sant Joan de Reus. A partir del estudi radiogràfic i biomecànic de les fractures i mitjançant la classificació de Fernández s’avalua el tractament realitzat, en termes de funcionalitat i resultat radiogràfic posterior. Els tractament utilitzats van ser: la reducció tancada i immobilització amb guix antebraquiopalmar (ABP), la reducció tancada i fixació percutánia amb agulles de Kirchner, la reducció oberta per abordatge palmar i fixació amb placa volar DVR (Distal Volar Radius). Els resultat s’avaluen amb l’escala de valoració de Gartland modificada. Fent una revisió actualitzada de la literatura i l’evidencia que existeix pel tractament de cada tipus de fractura.
Resumo:
En el nostre projecte, considerem un escenari urbà o interurbà on persones amb dispositius mòbils (smartphones) o vehicles equipats amb interfícies de comunicació, estan interessats en compartir fitxers entre ells o descarregar-los al creuar Punts d’Accés (APs) propers a la carretera. Estudiem la possibilitat d’utilizar la cooperació en les trobades casuals entre nodes per augmentar la velocitat de descàrrega global. Amb aquest objectiu, plantejem algoritmes per a la selecció de quins paquets, per a quins destins i quins transportistes s’escullen en cada moment. Mitjançant extenses simulacions, mostrem com les cooperacions carry&forward dels nodes augmenten significativament la velocitat de descàrrega dels usuaris, i com aquest resultat es manté per a diversos patrons de mobilitat, col•locacions d'AP i càrregues de la xarxa. Per altra banda, aparells com els smartphones, on la targeta de WiFi està encesa contínuament, consumeixen l'energia de la bateria en poques hores. En molts escenaris, una targeta WiFi sempre activa és poc útil, perque sovint no hi ha necessitat de transmissió o recepció. Aquest fet es veu agreujat en les Delay Tolerant Networks (DTN), on els nodes intercanvien dades quan es creuen i en tenen l’oportunitat. Les tècniques de gestió de l’estalvi d’energia permeten extendre la duració de les bateries. El nostre projecte analitza els avantatges i inconvenients que apareixen quan els nodes apaguen períodicament la seva targeta wireless per a estalviar energia en escenaris DTN. Els nostres resultats mostren les condicions en que un node pot desconnectar la bateria sense afectar la probabilitat de contacte amb altres nodes, i les condicions en que aquesta disminueix. Per exemple, es demostra que la vida del node pot ser duplicada mantenint la probabilitat de contacte a 1. I que aquesta disminueix ràpidament en intentar augmentar més la vida útil.
Resumo:
Desenvolupament d'una aplicació web amb projecció a comunitat virtual d’usuaris, que també integra un sistema de transmissió de streaming. Mitjançant aquest sistema els usuaris són capaços d’emetre o d’escoltar un programa radiofònic en temps real o offline.
Resumo:
Experimental studies in nude mice with human colon-carcinoma grafts demonstrated the therapeutic efficiency of F(ab')2 fragments to carcinoembryonic antigen (CEA) labeled with a high dose of 131Iodine. A phase I/II study was designed to determine the maximum tolerated dose of 131I-labeled F(ab')2 fragments (131I-F(ab')2) from anti-CEA monoclonal antibody F6, its limiting organ toxicity and tumor uptake. Ten patients with non-resectable liver metastases from colorectal cancer (9 detected by CT scan and 1 by laparotomy) were treated with 131I-F(ab')2, doses ranging from 87 mCi to 300 mCi for the first 5 patients, with a constant 300-mCi dose for the last 5 patients. For all the patients, autologous bone marrow was harvested and stored before treatment. Circulating CEA ranged from 2 to 126 ng/ml. No severe adverse events were observed during or immediately following infusion of therapeutic doses. The 9 patients with radiologic evidence of liver metastases showed uptake of 131I-F(ab')2 in the metastases, as observed by single-photon-emission tomography. The only toxicity was hematologic, and no severe aplasia was observed when up to 250 mCi was infused. At the 300-mCi dose, 5 out of 6 patients presented grade-3 or -4 hematologic toxicity, with a nadir for neutrophils and thrombocytes ranging from 25 to 35 days after infusion. In these 5 cases, bone marrow was re-infused. No clinical complications were observed during aplasia. The tumor response could be evaluated in 9 out of 10 patients. One patient showed a partial response of one small liver metastasis (2 cm in diameter) and a stable evolution of the other metastases, 2 patients had stable disease, and 6 showed tumor progression at the time of evaluation (2 or 3 months after injection) by CT scan. This phase-I/II study demonstrated that a dose of 300 mCi of 131I-F(ab')2 from the anti-CEA Mab F6 is well tolerated with bone-marrow rescue, whereas a dose of 200 mCi can be infused without severe bone-marrow toxicity.
Resumo:
While mobile technologies can provide great personalized services for mobile users, they also threaten their privacy. Such personalization-privacy paradox are particularly salient for context aware technology based mobile applications where user's behaviors, movement and habits can be associated with a consumer's personal identity. In this thesis, I studied the privacy issues in the mobile context, particularly focus on an adaptive privacy management system design for context-aware mobile devices, and explore the role of personalization and control over user's personal data. This allowed me to make multiple contributions, both theoretical and practical. In the theoretical world, I propose and prototype an adaptive Single-Sign On solution that use user's context information to protect user's private information for smartphone. To validate this solution, I first proved that user's context is a unique user identifier and context awareness technology can increase user's perceived ease of use of the system and service provider's authentication security. I then followed a design science research paradigm and implemented this solution into a mobile application called "Privacy Manager". I evaluated the utility by several focus group interviews, and overall the proposed solution fulfilled the expected function and users expressed their intentions to use this application. To better understand the personalization-privacy paradox, I built on the theoretical foundations of privacy calculus and technology acceptance model to conceptualize the theory of users' mobile privacy management. I also examined the role of personalization and control ability on my model and how these two elements interact with privacy calculus and mobile technology model. In the practical realm, this thesis contributes to the understanding of the tradeoff between the benefit of personalized services and user's privacy concerns it may cause. By pointing out new opportunities to rethink how user's context information can protect private data, it also suggests new elements for privacy related business models.
Resumo:
El presente TFC se centra en la creación de un sistema de información geográfica destinado a dispositivos móviles (Ipads, Smartphones ¿) y dedicado al senderismo, utilizando para ello varias aplicaciones de código abierto ofrecidas en la actualidad.
Resumo:
Treball de Fi de Carrera de .NET amb una pda i un web service.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
The movement of Open Educational Resources (OER) is one of the most important trends that are helping education through the Internet worldwide. "Tecnológico de Monterrey" (http://tecvirtual.itesm.mx/) in Mexico, with other Mexican higher education institutions, is creating an Internet/web based repository of OERs and Mobile Resources for the instruction and development of educational researchers at undergraduate, Master's and Doctoral level. There is a lack of open educational resources and material available at the Internet that can help and assist the development and education of educational researchers in Spanish speaking countries. This OER repository is part of a project that is experimenting new technology for the delivery of OERs from one repository (http://catedra.ruv.itesm.mx/) through an indexed OER catalog (http://www.temoa.info/) to mobile devices (Ipod, Iphone, MP3, MP4). This paper presentation will describe and comment about this project: outcomes, best practices, difficulties and technological constraints.
Resumo:
The estimation of camera egomotion is a well established problem in computer vision. Many approaches have been proposed based on both the discrete and the differential epipolar constraint. The discrete case is mainly used in self-calibrated stereoscopic systems, whereas the differential case deals with a unique moving camera. The article surveys several methods for mobile robot egomotion estimation covering more than 0.5 million samples using synthetic data. Results from real data are also given