995 resultados para Free distance
Resumo:
Mainland Portugal, on the southwestern edge of the European continent, is located directly north of the boundary between the Eurasian and Nubian plates. It lies in a region of slow lithospheric deformation (< 5 mm yr(-1)), which has generated some of the largest earthquakes in Europe, both intraplate (mainland) and interplate (offshore). Some offshore earthquakes are nucleated on old and cold lithospheric mantle, at depths down to 60 km. The seismicity of mainland Portugal and its adjacent offshore has been repeatedly classified as diffuse. In this paper, we analyse the instrumental earthquake catalogue for western Iberia, which covers the period between 1961 and 2013. Between 2010 and 2012, the catalogue was enriched with data from dense broad-band deployments. We show that although the plate boundary south of Portugal is diffuse, in that deformation is accommodated along several distributed faults rather than along one long linear plate boundary, the seismicity itself is not diffuse. Rather, when located using high-quality data, earthquakes collapse into well-defined clusters and lineations. We identify and characterize the most outstanding clusters and lineations of epicentres and correlate them with geophysical and tectonic features (historical seismicity, topography, geologically mapped faults, Moho depth, free-air gravity, magnetic anomalies and geotectonic units). Both onshore and offshore, clusters and lineations of earthquakes are aligned preferentially NNE-SSW and WNW-ESE. Cumulative seismic moment and epicentre density decrease from south to north, with increasing distance from the plate boundary. Only few earthquake lineations coincide with geologically mapped faults. Clusters and lineations that do not match geologically mapped faults may correspond to previously unmapped faults (e.g. blind faults), rheological boundaries or distributed fracturing inside blocks that are more brittle and therefore break more easily than neighbour blocks. The seismicity map of western Iberia presented in this article opens important questions concerning the regional seismotectonics. This work shows that the study of low-magnitude earthquakes using dense seismic deployments is a powerful tool to study lithospheric deformation in slowly deforming regions, such as western Iberia, where high-magnitude earthquakes occur with long recurrence intervals.
Resumo:
A one-pot template reaction of sodium 2-(2-(dicyanomethylene) hydrazinyl) benzenesulfonate (NaHL1) with water and manganese(II) acetate tetrahydrate led to the mononuclear complex [Mn(H2O)(6)](HL1a)(2)center dot 4H(2)O (1), where (HL1a) -= 2-(SO3-)C6H4(NH)=N=C(C N) (CONH2) is the carboxamide species derived from nucleophilic attack of water on a cyano group of (HL1) . The copper tetramer [Cu-4(H2O)(10)(-) (1 kappa N: kappa O-2: kappa O, 2 kappa N: k(O)-L-2)(2)]center dot 2H(2)O (2) was obtained from reaction of Cu(NO3)(2)center dot 2.5H(2)O with sodium 5-(2( 4,4-dimethyl-2,6-dioxocyclohexylidene) hydrazinyl)-4-hydroxybenzene-1,3-disulfonate (Na2H2L2). Both complexes were characterized by elemental analysis, IR spectroscopy, ESI-MS and single crystal X-ray diffraction. They exhibit a high catalytic activity for the solvent-and additive-free microwave (MW) assisted oxidation of primary and secondary alcohols with tert-butylhydroperoxide, leading to yields of the oxidized products up to 85.5% and TOFs up to 1.90 x 103 h(-1) after 1 h under low power (5-10 W) MW irradiation. Moreover, the heterogeneous catalysts are easily recovered and reused, at least for three consecutive cycles, maintaining 89% of the initial activity and a high selectivity.
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2’-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The Anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented proposal favored Ab/Ag affinity. The immunosensor design was evaluated by Quartz-Crystal microbalance with Dissipation, Atomic Force Microscopy, Electrochemical Impedance Spectroscopy (EIS) and Square-Wave Voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charged transfer resistance across the electrochemical sep-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from Glucose, Urea and Creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.
Resumo:
Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.
Resumo:
A label-free DNA aptamer-based impedance biosensor for the detection of E. coli outer membrane proteins (OMPs) was developed. Two single stranded DNA sequences were tested as recognition elements and compared. The aptamer capture probes were immobilized, with and without 6-mercapto-1-hexanol (MCH) on a gold electrode. Each step of the modification process was characterized by Faradaic impedance spectroscopy (FIS). A linear relationship between the electron-transfer resistance (Ret) and E. coli OMPs concentration was demonstrated in a dynamic detection range of 1 × 10−7–2 × 10−6 M. Moreover, the aptasensor showed selectivity despite the presence of other possible water contaminates and could be regenerated under low pH condition. The developed biosensor shows great potential to be incorporated in a biochip and used for in situ detection of E. coli OMPs in water samples.
Resumo:
Microcystin-LR (MC-LR) is a dangerous toxin found in environmental waters, quantified by high performance liquid chromatography and/or enzyme-linked immunosorbent assays. Quick, low cost and on-site analysis is thus required to ensure human safety and wide screening programs. This work proposes label-free potentiometric sensors made of solid-contact electrodes coated with a surface imprinted polymer on the surface of Multi-Walled Carbon NanoTubes (CNTs) incorporated in a polyvinyl chloride membrane. The imprinting effect was checked by using non-imprinted materials. The MC-LR sensitive sensors were evaluated, characterized and applied successfully in spiked environmental waters. The presented method offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.
Resumo:
The fast development of distance learning tools such as Open Educational Resources (OER) and Massive Open Online Courses (MOOC or MOOCs) are indicators of a shift in the way in which digital teaching and learning are understood. MOOC are a new style of online classes that allow any person with web access, anywhere, usually free of charge, to participate through video lectures, computer graded tests and discussion forums. They have been capturing the attention of many higher education institutions around the world. This paper will give us an overview of the “Introduction to Differential Calculus” a MOOC Project, created by an engaged volunteer team of Mathematics lecturers from four schools of the Polytechnic Institute of Oporto (IPP). The MOOC theories and their popularity are presented and complemented by a discussion of some MOOC definitions and their inherent advantages and disadvantages. It will also explore what MOOC mean for Mathematics education. The Project development is revealed by focusing on used MOOC structure, as well as the quite a lot of types of course materials produced. It ends with a presentation of a short discussion about problems and challenges met throughout the development of the project. It is also our goal to contribute for a change in the way teaching and learning Mathematics is seen and practiced nowadays, trying to make education more accessible to as many people as possible and increase our institution (IPP) recognition.
Resumo:
Paper presented at Geo-Spatial Crossroad GI_Forum, Salzburg, Austria.
Resumo:
Ao longo dos últimos anos, os scanners 3D têm tido uma utilização crescente nas mais variadas áreas. Desde a Medicina à Arqueologia, passando pelos vários tipos de indústria, ´e possível identificar aplicações destes sistemas. Essa crescente utilização deve-se, entre vários factores, ao aumento dos recursos computacionais, à simplicidade e `a diversidade das técnicas existentes, e `as vantagens dos scanners 3D comparativamente com outros sistemas. Estas vantagens são evidentes em áreas como a Medicina Forense, onde a fotografia, tradicionalmente utilizada para documentar objectos e provas, reduz a informação adquirida a duas dimensões. Apesar das vantagens associadas aos scanners 3D, um factor negativo é o preço elevado. No âmbito deste trabalho pretendeu-se desenvolver um scanner 3D de luz estruturada económico e eficaz, e um conjunto de algoritmos para o controlo do scanner, para a reconstrução de superfícies de estruturas analisadas, e para a validação dos resultados obtidos. O scanner 3D implementado ´e constituído por uma câmara e por um projector de vídeo ”off-the-shelf”, e por uma plataforma rotativa desenvolvida neste trabalho. A função da plataforma rotativa consiste em automatizar o scanner de modo a diminuir a interação dos utilizadores. Os algoritmos foram desenvolvidos recorrendo a pacotes de software open-source e a ferramentas gratuitas. O scanner 3D foi utilizado para adquirir informação 3D de um crânio, e o algoritmo para reconstrução de superfícies permitiu obter superfícies virtuais do crânio. Através do algoritmo de validação, as superfícies obtidas foram comparadas com uma superfície do mesmo crânio, obtida por tomografia computorizada (TC). O algoritmo de validação forneceu um mapa de distâncias entre regiões correspondentes nas duas superfícies, que permitiu quantificar a qualidade das superfícies obtidas. Com base no trabalho desenvolvido e nos resultados obtidos, é possível afirmar que foi criada uma base funcional para o varrimento de superfícies 3D de estruturas, apta para desenvolvimento futuro, mostrando que é possível obter alternativas aos métodos comerciais usando poucos recursos financeiros.
Resumo:
In cases of extensive damage to the foot, with significant bone loss, it is generally accepted that reconstruction must include bone flaps or grafts either in the emergency setting or subsequently. In this report, we describe the case of an 18-year-old student with an avulsion injury of the dorsum of his right foot. Consequently, he lost most of the soft tissue over the dorsum of the foot and the cuboid, navicular, and cuneiform bones. A latissimus dorsi free flap was used to reconstruct the defect. A functional pseudoarthrosis developed between the remaining bones of the foot, and the patient experienced satisfactory foot function after rehabilitation. For this reason, no additional reconstructive procedure was undertaken. This case suggests that it might be adequate to use the latissimus dorsi muscle flap more liberally than previously reported in the reconstruction of extensive defects of the dorsum of the foot, including cases with significant bone loss. This option could avoid the morbidity and inconvenience of a second surgery and the need to harvest a bone flap or graft.
Resumo:
Context: Inclusion of antioxidants in topical formulations can contribute to minimize oxidative stress in the skin, which has been associated with photoaging, several dermatosis and cancer. Objective: A Castanea sativa leaf extract with established antioxidant activity was incorporated into a semisolid surfactant-free formulation. The objective of this study was to perform a comprehensive characterization of this formulation. Materials and methods: Physical, microbiological and functional stability were evaluated during 6 months storage at 20 °C and 40 °C. Microstructure elucidation (cryo-SEM), in vitro release and in vivo moisturizing effect (Corneometer® CM 825) were also assessed. Results and discussion: Minor changes were observed in the textural and rheological properties of the formulation when stored at 20 °C for 6 months and the antioxidant activity of the plant extract remained constant throughout the storage period. Microbiological quality was confirmed at the end of the study. Under accelerated conditions, higher modifications of the evaluated parameters were observed. Cryo-SEM analysis revealed the presence of oil droplets dispersed into a gelified external phase. The release rate of the antioxidant compounds (610 ± 70 µgh−0.5) followed Higuchi model. A significant in vivo moisturizing effect was demonstrated, that lasted at least 4 h after product’s application. Conclusion: The physical, functional and microbiological stability of the antioxidant formulation was established. Specific storage conditions should be recommended considering the influence of temperature on the stability. A skin hydration effect and good skin tolerance were also found which suggests that this preparation can be useful in the prevention or treatment of oxidative stress-mediated dysfunctions.