777 resultados para Emergency-room
Resumo:
Chromia (Cr2O3) has been extensively explored for the purpose of developing widespread industrial applications, owing to the convergence of a variety of mechanical, physical and chemical properties in one single oxide material. Various methods have been used for large area synthesis of Cr2O3 films. However, for selective area growth and growth on thermally sensitive materials, laser-assisted chemical vapour deposition (LCVD) can be applied advantageously. Here we report on the growth of single layers of pure Cr2O3 onto sapphire substrates at room temperature by low pressure photolytic LCVD, using UV laser radiation and Cr(CO)(6) as chromium precursor. The feasibility of the LCVD technique to access selective area deposition of chromia thin films is demonstrated. Best results were obtained for a laser fluence of 120 mJ cm(-2) and a partial pressure ratio of O-2 to Cr(CO)(6) of 1.0. Samples grown with these experimental parameters are polycrystalline and their microstructure is characterised by a high density of particles whose size follows a lognormal distribution. Deposition rates of 0.1 nm s(-1) and mean particle sizes of 1.85 mu m were measured for these films. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
This paper starts with the analysis of the unusual inherence mechanism, from two aspects: accumulating and human error. We put forward twelve factors affected the decision of the emergency treatment plan in practice and summarized the evaluation index system combining with literature data. Then we screened out eighteen representative indicators by used the FDM expert questionnaire in the first phase. Hereafter, we calculated the weight of evaluation index and sorted them by the FAHP expert questionnaire, and came up with the frame of the evaluation rule by combined with the experience. In the end, the evaluation principles are concluded.
Resumo:
Energy resources management can play a very relevant role in future power systems in a SmartGrid context, with intensive penetration of distributed generation and storage systems. This paper deals with the importance of resource management in incident situations. The paper presents DemSi, an energy resources management simulator that has been developed by the authors to simulate electrical distribution networks with high distributed generation penetration, storage in network points and customers with demand response contracts. DemSi is used to undertake simulations for an incident scenario, evidencing the advantages of adequately using flexible contracts, storage, and reserve in order to limit incident consequences.
Resumo:
Decision Making is one of the most important activities of the human being. Nowadays decisions imply to consider many different points of view, so decisions are commonly taken by formal or informal groups of persons. Groups exchange ideas or engage in a process of argumentation and counter-argumentation, negotiate, cooperate, collaborate or even discuss techniques and/or methodologies for problem solving. Group Decision Making is a social activity in which the discussion and results consider a combination of rational and emotional aspects. In this paper we will present a Smart Decision Room, LAID (Laboratory of Ambient Intelligence for Decision Making). In LAID environment it is provided the support to meeting room participants in the argumentation and decision making processes, combining rational and emotional aspects.
Resumo:
The measurement of room impulse response (RIR) when there are high background noise levels frequently means one must deal with very low signal-to-noise ratios (SNR). if such is the case, the measurement might yield unreliable results, even when synchronous averaging techniques are used. Furthermore, if there are non-linearities in the apparatus or system time variances, the final SNR can be severely degraded. The test signals used in RIR measurement are often disturbed by non-stationary ambient noise components. A novel approach based on the energy analysis of ambient noise - both in the time and in frequency - was considered. A modified maximum length sequence (MLS) measurement technique. referred to herein as the hybrid MLS technique, was developed for use in room acoustics. The technique consists of reducing the noise energy of the captured sequences before applying the averaging technique in order to improve the overall SNRs and frequency response accuracy. Experiments were conducted under real conditions with different types of underlying ambient noises. Results are shown and discussed. Advantages and disadvantages of the hybrid MLS technique over standard MLS technique are evaluated and discussed. Our findings show that the new technique leads to a significant increase in the overall SNR. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Lighting is one of the most important factors in human interaction with the environment. Poor lighting may increase the risk of accidents and could also cause a variety of symptoms including: rapid fatigue, headaches, eyestrain, tired eyes, dry eyes, ocular surface symptoms (watery and irritated eyes), decreased concentration and stress. Specific disorders: degeneration of the sharpness of vision (blurred and double vision) and slowness in changing focus. Apart from the advantages in the health and welfare for the workers, good lighting also leads to better job performance (faster), less errors, better safety, fewer accidents and less absenteeism. The overall effect is: better productivity. Good lighting includes quantity and quality requirements, and should necessarily be appropriate to the activity/task being carried out, bearing in mind the comfort and visual efficiency of the worker.
Resumo:
The phase behaviour of a number of N-alkylimidazolium salts was studied using polarizing optical microscopy, differential scanning calorimetry and X-ray diffraction. Two of these compounds exhibit lamellar mesophases at temperatures above 50 degrees C. In these systems, the liquid crystalline behaviour may be induced at room temperature by shear. Sheared films of these materials, observed between crossed polarisers, have a morphology that is typical of (wet) liquid foams: they partition into dark domains separated by brighter (birefringent) walls, which are approximately arcs of circle and meet at "Plateau borders" with three or more sides. Where walls meet three at a time, they do so at approximately 120 degrees angles. These patterns coarsen with time and both T1 and T2 processes have been observed, as in foams. The time evolution of domains is also consistent with von Neumann's law. We conjecture that the bright walls are regions of high concentration of defects produced by shear, and that the system is dominated by the interfacial tension between these walls and the uniform domains. The control of self-organised monodomains, as observed in these systems, is expected to play an important role in potential applications.
Resumo:
Advanced Materials, Vol. 17, nº 5
Resumo:
Thin Solid Films, vol. 427, nº 1-2
Resumo:
According to the hedonic price method, a price of a good is related with the characteristics or the services it provides. Within this framework, the aim of this study it is to examine the effect on room rates of different characteristics of hotels in and around the city of Porto, such as star category, size, room and service quality, hotel facilities and location. It was estimated a hedonic price function, using data for 51 hotels. The results enable to identify the attributes that are important to consumers and hoteliers and to which extent. This information can be used by hotel managers to define a price strategy and helpful in new investment decisions.
Resumo:
The aim of the present study was to investigate the detection percentage of tuberculosis among patients that are respiratory symptomatic (TB suspects). In this work, we present the preliminary results of research carried out at "Hospital das Clínicas de Teresópolis Costantino Ottaviano da Fundação Educacional Serra dos Órgãos (FESO)" from November 2003 to April 2004. Among the 40 respiratory symptomatic individuals identified and referred to the Tuberculosis Control Program in Teresópolis, two (5.0%) were characterized as smear-positive. These results confirm reports in the literature and underscore the need for and importance of this strategy.
Resumo:
BACKGROUND: Variations in emergency department admissions have been reported to happen as a result of major sports events. The work presented assessed changes in volume and urgency level of visits to a major Emergency Department in Lisbon during and after the city's football derby. MATERIAL AND METHODS: Volume of attendances and patient urgency level, according to the Manchester Triage System, were retrospectively analyzed for the 2008-2011 period. Data regarding 24-hour periods starting 45 minutes before kick-off was collected, along with data from similar periods on the corresponding weekdays in the previous years, to be used as controls. Data samples were organized according to time frame (during and after the match), urgency level, and paired accordingly. RESULTS: A total of 14 relevant periods (7 match and 7 non-match) were analyzed, corresponding to a total of 5861 admissions. During the match time frame, a 20.6% reduction (p = 0.06) in the total number of attendances was found when compared to non-match days. MTS urgency level sub-analysis only showed a statistically significant reduction (26.5%; p = 0.05) in less urgent admissions (triage levels green-blue). Compared to controls, post-match time frames showed a global increase in admissions (5.6%; p = 0.45), significant only when considering less urgent ones (18.9%; p = 0.05). DISCUSSION: A decrease in the total number of emergency department attendances occurred during the matches, followed by a subsequent increase in the following hours. These variations only reached significance among visits triaged green-blue. CONCLUSION: During major sports events an overall decrease in emergency department admissions seems to take place, especially due to a drop in visits associated with less severe conditions.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Nursing home-acquired pneumonia (NHAP) is one of the most common infections arising amongst nursing home residents, and its incidence is expected to increase as population ages. The NHAP recommendation for empiric broad-spectrum antibiotic therapy, arising from the concept of healthcare-associated pneumonia, has been challenged by recent studies reporting low rates of multidrug-resistant (MDR) bacteria. This single center study analyzes the results of NHAP patients admitted through the Emergency Department (ED) at a tertiary center during the year 2010. There were 116 cases, male gender corresponded to 34.5 % of patients and median age was 84 years old (IQR 77-90). Comorbidities were present in 69.8 % of cases and 48.3 % of patients had used healthcare services during the previous 90 days. In-hospital mortality rate was 46.6 % and median length-of-stay was 9 days. Severity assessment at the Emergency Department provided CURB65 index score and respective mortality (%) results: zero: n = 0; one: n = 7 (0 %); two: n = 18 (38.9 %); three: n = 26 (38.5 %); four: n = 30 (53.3 %); and five; n = 22 (68.2 %); and sepsis n = 50 (34.0 %), severe sepsis n = 43 (48.8 %) and septic shock n = 22 (72.7 %). Significant risk factors for in-hospital mortality in multivariate analysis were polypnea (p = 0.001), age ≥ 75 years (p = 0.02), and severe sepsis or shock (p = 0.03) at the ED. Microbiological testing in 78.4 % of cases was positive in 15.4 % (n = 15): methicillin-resistant Staphylococcus aureus (26.7 %), Pseudomonas aeruginosa (20.0 %), S. pneumoniae (13.3 %), Escherichia coli (13.3 %), others (26.7 %); the rate of MDR bacteria was 53.3 %. This study reveals high rates of mortality and MDR bacteria among NHAP hospital admissions supporting the use of empirical broad-spectrum antibiotic therapy in these patients.