965 resultados para Direct measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis evaluates different sites for a weather measurement system and a suitable PV- simulation for University of Surabaya (UBAYA) in Indonesia/Java. The weather station is able to monitor all common weather phenomena including solar insolation. It is planned to use the data for scientific and educational purposes in the renewable energy studies. During evaluation and installation it falls into place that official specifications from global meteorological organizations could not be meet for some sensors caused by the conditions of UBAYA campus. After arranging the hardware the weather at the site was monitored for period of time. A comparison with different official sources from ground based and satellite bases measurements showed differences in wind and solar radiation. In some cases the monthly average solar insolation was deviating 42 % for satellite-based measurements. For the ground based it was less than 10 %. The average wind speed has a difference of 33 % compared to a source, which evaluated the wind power in Surabaya. The wind direction shows instabilities towards east compared with data from local weather station at the airport. PSET has the chance to get some investments to investigate photovoltaic on there own roof. With several simulations a suitable roof direction and the yearly and monthly outputs are shown. With a 7.7 kWpeak PV installation with the latest crystalline technology on the market 8.82 MWh/year could be achieved with weather data from 2012. Thin film technology could increase the value up to 9.13 MWh/year. However, the roofs have enough area to install PV. Finally the low price of electricity in Indonesia makes it not worth to feed in the energy into the public grid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The systematic measurement of HIV/AIDS-related discrimination is imperative within the current rhetoric that holds discrimination as one of the two ‘biggest' barriers to HIV/AIDS pandemic intervention. This paper provides a methodological critique of the UNAIDS (2000b) Protocol for the Identification of Discrimination against People Living with HIV (the Protocol) . Specifically, the paper focuses on the Protocol's capacity to accurately identify and measure institutional levels of HIV-related discrimination that allows data that are reliable and comparable across time and contexts. Conceptual issues including the Protocol's objective as an indicator versus a direct measure of discrimination and the role of the Protocol as a tool of research versus a tool of advocacy are explored. Design issues such as the operationalization of discrimination, appropriateness of indicator content, sampling and data collection strategies and issues of scoring are also evaluated. It is hoped that the matters outlined will provide readers with ways of critically reflecting and evaluating the findings of the research papers presented in this Special Issue, as well as pointing to ways of improving research design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this study are (1) to establish a reliable and valid quality-of-life (QOL) questionnaire for Chinese patients with head and neck (H&N) cancer who are treated with radiation therapy and (2) to evaluate the impact of the immediate side effects of treatment on the QOL of these patients. The 39-item "Quality of Life Radiation Therapy Instrument with Head and Neck Companion Module" (QOL-RTI/H&N) was translated into Chinese. In the reliability evaluation phase (study module 1), the questionnaire was administered twice to 56 H&N cancer patients, 7 days apart, during the second and third week of radiation therapy. In the validity evaluation phase (study module 2), 138 patients completed the QOL-RTI/H&N before starting and at the end of radiation therapy. Sixty-nine of these 138 patients also completed the QOL-RTI/H&N during the second week of their radiation therapy, at the same time as completing the Functional Assessment of Cancer Therapy-Head and Neck (FACT-H&N) questionnaire. Cronbach alpha coefficients were 0.88 for the general-tool QOL-RTI and 0.90 for the H&N subscale. Test-retest reliability was satisfactory with intraclass correlation coefficients of 0.89 for the general-tool QOL-RTI and 0.75 for the H&N subscale. The instrument can discriminate between patients with stage I or II disease and those with stage III or IV disease (P < .05). Concurrent validity was established by the good agreement with the FACT-H&N (r = 0.86, P < .001). A highly significant deterioration was in the QOL from the baseline to the end of treatment (mean difference for general tool = 1.95, P < .001; mean difference for H&N subscale = 4.85, P < .001). The Chinese QOL-RTI/H&N is a reliable and valid tool for determining the QOL in H&N cancer patients receiving radiation therapy. The immediate side effects of treatment had a significantly negative impact on the patients' QOL. The impact was relatively large for the functional and treatment-site aspects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis describes the utilisation of chemiluminescence (chemically generated light) for clinical diagnosis and process monitoring. Innovative instrumentation was developed for the direct monitoring of toxin levels in patients undergoing haemodialysis. This unique approach enables the efficacy of individual treatments to be continuously assessed thus enhancing patient outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The degree of light penetration along the length of the fibre of a simulated Merino fleece was measured using a fibre optic probe to investigate the relationship between light exposure and photodamage to the wool fibre. The percentage of the total direct sunlight that reached the base of the 100-mm long, simulated, closed Merino fleece was ~1% and the section of the fibre from the root to 60 mm from the root was protected from exposure. The light intensity at the base of the fibre was increased to 2% when the density of the simulated fleece was halved. Wool was scoured and the yellowness and intensity of methylene blue staining was measured to estimate the extent of damage to wool staples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Direct measurements of the force between two molecularly smooth mica sheets immersed in cyclohexane show not a monotonic van der Waals attraction, but an oscillatory function of distance, where the spacing between successive minima corresponds to the molecular diameter of cyclohexane. As surface separation increases the oscillations become less pronounced, and beyond 5 nm (typically seven or eight oscillations) they are no longer detected. These results accord with theoretical ideas on structural forces resulting from the inhomogeneous arrangement of molecules of the liquid near the solid surface. In n-octane the force law does not show the same pronounced oscillations, except at very small separations where repulsive barriers are found. These are attributed to the difficulty of removing the last layers of adsorbed molecules of the liquid from the mica surfaces, and they reduce the mice-mica adhesion significantly. Small amounts of water in the hydrocarbon liquids condense to form a bridge between the surfaces at small separations, causing a very strong adhesion between them. Some implications of these results for the stability of colloids in organic media are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automated laparoscopic instrument capable of non-invasive measurement of tip/tissue interaction forces for direct application in robotic assisted minimally invasive surgery systems_ is introduced in this paper. It has the capability to measure normal grasping forces as well as lateral interaction forces without any sensor mounted on the tip jaws. Further to non-invasive actuation of the tip, the proposed instrument is also able to change the grasping direction during surgical operation. Modular design of the instrument allows conversion between surgical modalities (e.g., grasping, cutting, and dissecting). The main focus of this paper is on evaluation of the grasping force capability of the proposed instrument. The mathematical formulation of fenestrated insert is presented and its non-linear behaviour is studied. In order to measure the stiffness of soft tissues, a device was developed that is also described in this paper. Tissue characterisation experiments were conducted and results are presented and analysed here. The experimental results verify the capability of the proposed instrument in accurately measuring grasping forces and in characterising artificial tissue samples of varying stiffness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Invoking a resource-based view (RBV), this study investigates relationships between management control systems (MCSs) use, including information use from performance measurement systems (PMSs), and organisational capabilities in the context of academic units of Australian universities. Increased competition and attention to distinctive capabilities amongst universities, particularly at their strategic operating unit level of a Faculty1 or School2, provides the setting for application of this theoretic perspective. Based on a questionnaire survey of all Faculty Deans and Heads of Schools in all 39 universities in Australia, evidence is provided on relationships between diagnostic and interactive use of MCSs, attention given to imposed and discretionary types of PMS information, the strength of capabilities of the academic unit and, in turn, overall performance of the academic unit. Highlights of findings are that Heads/Deans conceived capabilities of their unit in functional dimensions, not in generic dimensions as found in prior literature; interactive MCS use and imposed performance measures, respectively, direct relate to several types of capabilities and indirectly to performance of the academic unit, but diagnostic MCS use does not. The findings have practical implications for styles of control systems use and performance information use by management in universities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)