845 resultados para Device fabrication
Resumo:
Parastomal hernia (PSH) is the most frequent long-term stoma complication with serious negative effects on quality of life. Surgical revision is often required and has a substantial morbidity and recurrence rate. The development of PSH requires revisional surgery with a substantial perioperative morbidity and high failure rate in the long-term follow-up. Prophylactic parastomal mesh insertion during stoma creation has the potential to reduce the rate of PSH, but carries the risk of early and late mesh-related complications such as infection, fibrosis, mesh shrinkage, and/or bowel erosion. We developed a new stomaplasty ring (KORING), which is easy to implant, avoids potential mesh-related complications, and has a high potential of long-term prevention of PSH. Here we describe the technique and the first use.
Resumo:
Työn tavoitteena oli kuvata piirilevyvalmistaja Aspocomp Oy:n Espoon tehtaan tämän hetkinen tuotannonohjausperiaate ja tunnistaa siinä esiintyvät puutteet sekä kehittää vaihtoehtoinen tuotannonohjausperiaate piirilevyvalmistukseen. Vaihtoehtoisen ohjausperiaatteen lähtökohtana oli tuotannonohjauksen sopeuttaminen vaativaan ja jatkuvasti muuttuvaan liiketoimintaympäristöön. Työn teoreettinen osa keskittyi tuotannonohjauksen eri lähestymistapoihin. Kirjallisuuskatsauksessa esitetään eri tuotannonohjausperiaatteiden keskeiset sisällöt, jotka muodostavat rungon toimivalle tuotannonohjauskäytännölle. Työn kokeellinen osa keskittyi Espoon piirilevytehtaan tuotannonohjausperiaatteen selvittämiseen. Espoon piirilevytehtaan nykyisessä tuotannonohjausperiaatteessa havaittujen ongelmakohtien ja liiketoimintaympäristön vaatimusten perusteella kehitettiin vaihtoehtoinen tuotannonohjaustapa. Vaihtoehtoisen tuotannonohjaustavan päämääränä oli läpimenoajan lyhentäminen sekä tuotannon parempi hallittavuus. Vaihtoehtoinen toimintamalli tavoitteiden saavuttamiseksi perustuu pullonkaulateoriaan, jossa keskeisin muutos nykyiseen toimintamalliin oli puolivalmisteiden varastointi toimitusajan lyhentämiseksi sekä tuotantovolyymin heilahdusten vaikutusten vähentämiseksi. Työn kokeellisessa osassa ilmeni, että kysynnän muutokset ja kapasiteetin suunnittelun puute aiheuttivat ongelmia piirilevytehtaan tuotannonohjauksessa.
Resumo:
CORBA (Common Object Request Broker Architecture) on laajalle levinnyt ja teollisuudessa yleisesti käytetty hajautetun tietojenkäsittelyn arkkitehtuuri. CORBA skaalautuu eri kokoisiin tarpeisiin ja sitä voidaan hyödynntää myös sulautetuissa langattomissa laitteissa. Oleellista sulautetussa ympäristössä on rakentaa rajapinnat kevytrakenteisiksi, pysyviksi ja helposti laajennettaviksi ilman että yhteensopivuus aikaisempiin rajapintoihin olisi vaarassa. Langattomissa laitteissa resurssit, kuten muistin määrä ja prosessointiteho, ovat hyvin rajalliset, joten rajapinta tulee suunnitella ja toteuttaa optimaalisesti. Palveluiden tulee ottaa huomioon myös langattomuuden rajoitukset, kuten hitaat tiedonsiirtonopeudet ja tiedonsiirron yhteydettömän luonteen. Työssä suunniteltiin ja toteutettiin CORBA-rajapinta GSM-päätelaitteeseen, jonka on todettu täyttävän sille asetetut tavoitteet. Rajapinta tarjoaa kaikki yleisimmät GSM-terminaalin ominaisuudet ja on laajennettavissa tulevia tuotteita ja verkkotekniikoita varten. Laajennettavuutta saavutetaan esimerkiksi kuvaamalla terminaalin ominaisuudet yleisellä kuvauskielellä, kuten XML:lla (Extensible Markup Language).
Resumo:
The University of Barcelona is developing a pilot-scale hot wire chemical vapor deposition (HW-CVD) set up for the deposition of nano-crystalline silicon (nc-Si:H) on 10 cm × 10 cm glass substrate at high deposition rate. The system manages 12 thin wires of 0.15-0.2 mm diameter in a very dense configuration. This permits depositing very uniform films, with inhomogeneities lower than 2.5%, at high deposition rate (1.5-3 nm/s), and maintaining the substrate temperature relatively low (250 °C). The wire configuration design, based on radicals' diffusion simulation, is exposed and the predicted homogeneity is validated with optical transmission scanning measurements of the deposited samples. Different deposition series were carried out by varying the substrate temperature, the silane to hydrogen dilution and the deposition pressure. By means of Fourier transform infrared spectroscopy (FTIR), the evolution in time of the nc-Si:H vibrational modes was monitored. Particular importance has been given to the study of the material stability against post-deposition oxidation.
Resumo:
Polysilicon thin film transistors (TFT) are of great interest in the field of large area microelectronics, especially because of their application as active elements in flat panel displays. Different deposition techniques are in tough competition with the objective to obtain device-quality polysilicon thin films at low temperature. In this paper we present the preliminary results obtained with the fabrication of TFT deposited by hot-wire chemical vapor deposition (HWCVD). Some results concerned with the structural characterization of the material and electrical performance of the device are presented.
Resumo:
We described for the first time the amino acid substitutions conferring rifampicin resistance in eight Propionibacterium acnes strains isolated from patients with biofilm or device-related infections. We identified different mutations in cluster I and one mutation, never reported, in cluster II of the rpoB gene (I480V) associated with the most frequent one in cluster I (S442L). Half of the patients previously received treatment with rifampicin.
Resumo:
OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.
Resumo:
Testing of a complex software is time consuming. Automated tools are available quite a lot for desktop applications, but for embedded systems a custom-made tool is required Building a complete test framework is a complicated task. Therefore, the test platform was built on top of an already existing tool, CANoe. CANoe is a tool for CAN bus analysis and node simulation. The functionality of CANoe was extended with LabVIEW DLL. The LabVIEW software was used for simulating hardware components of the embedded device As a result of the study, a platform was created where tests could be automated. Of the current test plan, 10 percent were automated and up to 60 percent could be automated with the current functionality.
Resumo:
In this thesis theoretical and technological aspects of fiber Bragg gratings (FBG) are considered. The fabrication of uniform and chirped fiber Bragg gratings using phase mask technique has been exploited throughout this study. Different requires of FBG inscription were considered and implemented experimentally to find economical and effective procedure. The hydrogen loading was used as a method for enhancement the photosensitivity of the fiber. The minimum loading time for uniform and chirped fiber Bragg gratings was determined as 3 days and 7 days at T = 50°C and hydrogen pressure 140 bar, respectively. The post-inscription annealing was considered to avoid excess losses induced by the hydrogen. The wavelength evolution during annealing was measured. The strain and temperature sensor application of FBG was considered. The wavelength shifts caused by tension and temperature were studied for both uniform and chirp fiber Bragg gratings.
Resumo:
Raspberry Pi is a low-cost computer created with educational purposes. It uses Linux and, most of times, freeware applications, particularly a software for viewing DICOM images. With an external monitor, the supported resolution (1920 × 1200 pixels) allows for the set up of simple viewing workstations at a reduced cost.
Resumo:
In this technical note, we describe the construction of a low-cost computer controlled device for layer-by-layer film fabrication. The software allows to control multiple material deposition, washing and drying steps and the time for each operation. To test the device, we produced and characterized self-assembled films of conductive polymers by alternating poly(o-methoxyaniline) (POMA) and poly(3-thiophene acetic acid) (PTAA) via the layer-by-layer technique.
Resumo:
Due to font problem on the tilte field the titlte of the thesis is corrected here. The title of the thesis is: Magnetic Perovskites Sr2FeMoO6 and La(1-x)Ca(x)MnO3: Synthesis, Fabrication and Characterization of Nanosized Powders and Thin Films
Resumo:
Here we investigate the formation of superficial micro- and nanostructures in poly(ethylene-2,6-naphthalate) (PEN), with a view to their use in biomedical device applications, and compare its performance with a polymer commonly used for the fabrication of these devices, poly(methyl methacrylate) (PMMA). The PEN is found to replicate both micro- and nanostructures in its surface, albeit requiring more forceful replication conditions than PMMA, producing a slight increase in surface hydrophilicity. This ability to form micro/nanostructures, allied to biocompatibility and good optical transparency, suggests that PEN could be a useful material for production of, or for incorporation into, transparent devices for biomedical applications. Such devices will be able to be autoclaved, due to the polymer's high temperature stability, and will be useful for applications where forceful experimental conditions are required, due to a superior chemical resistance over PMMA.