1000 resultados para Coeficiente de pressão
Resumo:
The quality of the gasoline utilized for fueling internal combustion engines with spark ignition is directly affected by the gasoline's properties. Thus, the fuel's properties must be in perfect equilibrium to allow the engine to perform optimally, not only insofar as fuel consumption is concerned, but also in order to reduce the emission of pollutants. Vapor pressure and vaporization enthalpy are important properties of a gasoline determining the fuel's behavior under different operating conditions in internal combustion engines. The study reported here involved the development of a device to determine the vapor pressure and the vaporization enthalpy of formulations containing volumes of 5, 15 and 25% of ethanol in four base gasolines (G1, G2, G3 and G4). The chemical composition of these gasolines was determined using a gas chromatographer equipped with a flame ionization detector (FID).
Resumo:
Leaking of diesel oil from gas stations is frequent in Brazil. The presence of polycyclic aromatic hydrocarbons (PAHs), which are highly toxic is an indication of contamination by heavy hydrocarbons from diesel oil. Here were present the determination of the distribution coefficient (Kd) of benzo(a)pyrene (the most carcinogenic of the PAHs) in tropical soils using the sorption isotherm model. The sorption curves acquired for benzo(a)pyrene were of the S-type, probably due to the water/methanol experimental conditions. The sorption curves allowed calculation of the distribution coefficient (Kd). The experimental Kd values were lower than those calculated from literature Koc values (partition coefficient normalized by organic carbon), due mainly to the cosolvency effect and the percentage of organic matter and clay in soil.
Resumo:
In this study a new approach, solid phase micro extraction (SPME), is used in the evaluation of the infinite dilution activity coefficient of the solute in a given solvent. It is the purpose of the current work to demonstrate a different approach to obtain the data needed for studying the solution thermodynamics of binary liquid mixtures as well as for designing multi-component separations. The solutes investigated at the temperature 298.15 K were toluene, ethyl benzene and xylene in the solvent methanol.
Uso da pressão gerada por uma coluna de água para controle da vazão em sistemas de análises em fluxo
Resumo:
This work presents a new approach to control the flow rate in hydrodynamic flow experiments. The combination of air pressure generated by an aquarium air pump and the pressure generated by a water column were used for this purpose. This device supports a stable flow rate without pulsation for a long period of time. Furthermore, the flow rate can be easily controlled at various values in one or more streams. The performance of this approach was investigated using Fe(CN)6(4-) solutions in flowing systems using amperometric and voltammetric detection in wall-jet configuration. The results showed that the performance of the proposed device was better than a commercial peristaltic pump. It suggests that this approach can be used successfully in flow analysis systems.
Resumo:
Vacuum pumps are very useful in physical, chemical and biological experiments. In this communication it is described the design of a compact and low cost water recirculating system employing a water-jet aspirator pump as the vacuum source. The system requires only a water pump, water-jet aspirator pump, commercial PVC water tubes and a drain connection.
Resumo:
The objective of this work was to use the high-pressure homogenizer (HPH) to prepare stable oil/water nanoemulsions presenting narrow particle size distribution. The dispersions were prepared using nonionic surfactants based on ethoxylated ether. The size and distribution of the droplets formed, along with their stability, were determined in a Zetasizer Nano ZS particle size analyzer. The stability and the droplet size distribution in these systems do not present the significant differences with the increase of the processing pressure in the HPH). The processing time can promote the biggest dispersion in the size of particles, thus reducing its stability.
Resumo:
The pollutant transference among reservoirs atmosphere-hydrosphere, relevant to the atmospheric chemistry, depends upon scavenging coefficient (Λ) calculus, which depends on the raindrop size distribution as well as on the rainfall systems, both different to each locality. In this work, the Λ calculus will be evaluated to gas SO2 and particulate matter fine and coarse among five sites in Germany and two in Brazil. The results show three possible classifications in function of Λ, comparable to literature, however with a greater range due to the differences of rainfall system sites. This preliminary study supports future researches
Resumo:
An UV-Ozone reactor was developed with an ignition tube extracted into HID mercury lamp used to irradiation on zinc oxide (ZnO) and fluorinated tin oxide (FTO) films for PLEDs devices. Different exposures times were used. In contact angle measurements revealed better results for ZnO and FTO by 15 and 5 min, respectively. In Diffuse Reflectance Infra-red Fourier Transformed (DRIFT) spectroscopy allowed the observation of water, hydrocarbon and carbon dioxide adsorbed on the untreated TCO surfaces. After the UV-Ozone treatment the contaminants were significantly reduced or eliminated and the PLEDs devices decreased threshold voltages in comparison with respectively untreated TCOs.
Resumo:
In this work a new method (SPME-GC/FID) was developed to analyze the activity of binary liquid mixtures. The purpose is to demonstrate that SPME is capable to be used to determinate activity coefficients at infinite dilution knowing the fiber properties, with a lower cost than the conventional methods encountered in literature such as GLC. The activity coefficients at infinite dilution in furfural for n-hexane, n-heptane and cyclohexane at 298.15 K was determined using SPME and deviations of literature data was about 7%.
Resumo:
The use of fatty acids (FAs) as amphiphiles is very important because they have a behaving similar to surfactants. The formulation for the preferential partition of these species was studied by varying the amount of salt at constant acid concentration. As the salt concentration increases, a Winsor I→III→II transition is observed for all the systems studied. Furthermore, the electrolyte concentration required to obtain the optimum formulation varies inversely with the chain length of the acid. The partition coefficient of the surfactant allows one to obtain thermodynamic information on the acid transfer process between the phases of the system.
Resumo:
The aim of this study was to investigate the sorption and desorption of thiamethoxam in contrasting soils under the effect of organic acids. The results showed that MTo sorption had higher Kd. The presence of organic acids increased sorption and reduced desorption of thiamethoxam at MTo. The opposite was observed for the LVdf where the presence of 400 µmol L-1 of acid reduced the sorption of thiamethoxam in a concentration of 20 µmol L-1, not influencing desorption. The dynamics of organic acids with minerals from the soil particles were clarified by infrared analysis.
Resumo:
Extraction/concentration is a crucial step for the analysis of organic compounds at trace level concentrations and dispersed in complex matrices. Solid-phase extraction (SPE) is one of the techniques used for this purpose. In this work, a low cost apparatus for SPE was developed that uses nitrogen under positive pressure and ensures the maintenance of the sample flow, while also allows the simultaneous extraction of different samples without cross-contamination and sample contact with plastic materials. For the system set up, easily accessible materials were used such as hypodermic needles, stainless steel tubes, rubber stoppers, and 3-way valves from serum delivery apparatus.
Resumo:
A new method using the headspace solid phase microextraction (HS-SPME) technique was used to evaluate the infinite dilute activity coefficient (γ1∞) in an alcohol/water/salt system. The studied systems were ethanol and water with NaCl and NH4Cl at salt concentrations of 5, 10, 15, and 30% m/v and temperatures of 303.15 and 313.15 K. The method was used to investigate the salt effect on vapor/liquid equilibrium in an ethanol/water system, yielding satisfactory results. The study focused on the rich side in ethanol. The data were compared with the literature infinite dilution data determined by other methods such as differential ebulliometry (EBUL), differential static cell equilibrium (STAT), and gas-liquid chromatography with no gas phase correction (GC). In this study, NaCl showed better separation rates than NH4Cl.
Resumo:
Pressão interna, volume livre, refração molar e propriedades termodinâmicas de excesso de misturas líquidas binárias de dimetil sulfóxido + tiofeno e dimetil sulfóxido + piridina a 298.15K foram calculadas a partir de medidas experimentais de densidades, tensão superficial e índice de refração. A relação entre a pressão interna, volume molar de excesso, refração molar, e a interação molecular dos sistemas binários é examinada.
Resumo:
O objetivo deste trabalho foi determinar o coeficiente de expansão térmica do biodiesel a partir de dados experimentais de densidade em função da temperatura. Para tanto, foram utilizados alguns fundamentos da termodinâmica. O valor obtido para o coeficiente de expansão térmica após regressão linear para o biodiesel foi de 8,49 × 10-4 ºC-1, com um coeficiente de correlação igual a 0,9978.