941 resultados para Calibrador de dose


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic atrial natriuretic peptide, containing 26 amino acids in the rat sequence, L-364, 343 (Ileu-ANP), was infused intravenously at increasing rates (1-40 micrograms/min) into four normal volunteers. Mean intraarterial blood pressure decreased and heart rate increased in cumulative-dose-dependent fashion. Skin blood flow as measured with a laser Doppler device rose already with a cumulative dose of 55 micrograms Ileu-ANP and further rises were directly related to dose. The only side effects observed were those accompanying symptomatic hypotension at higher doses. These findings provide strong evidence that Ileu-ANP acts as a vasodilator in normal volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate the effects of continuous and acute L-carnitine supplementation of total parenteral nutrition (TPN) on protein and fat oxidation in severe catabolism. A critically ill and severely malnourished male patient received TPN (non protein energy = 41 kcal/kg/day, provided equally as fat and glucose) over 38 days, without L-carnitine for 23 days and with carnitine supplements (15 mg/kg/day) for the following 15 days. Subsequently, he was given carnitine-free enteral nutrition for 60 more days. A four-hour infusion of 100 mg L-carnitine was given on day 11 of each TPN period. Indirect calorimetry was carried out after 11 days of either carnitine-free or supplemented TPN and at the initiation of enteral nutrition. Additional measurements were performed 4 hours and 24 hours after the acute infusions of carnitine. The rate of protein oxidation and the respiratory quotient were found to be higher, and the rate of fat oxidation to be lower, with carnitine-supplemented TPN, than with either carnitine-free TPN or enteral nutrition. Acute infusion of carnitine resulted in an increased rate of protein oxidation and a reduced rate of fat oxidation on both TPN-regimens. These unfavourable effects on protein metabolism may be due to an impairment of fat oxidation by excess amounts of carnitine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Background: Chronic obstructive pulmonary disease (COPD) is characterised by an abnormal inflammatory response mainly to cigarette smoke that flares up during exacerbations of the disease (ECOPD). Reduced activity of histone deacetylases (HDAC) contributes to enhanced inflammation in stable COPD. It was hypothesised that HDAC activity is further reduced during ECOPD and that theophylline, an HDAC activator, potentiates the antiinflammatory effect of steroids in these patients. A study was performed to investigate HDAC activity during ECOPD and the effects of theophylline on the anti-inflammatory effects of steroids in a randomised single-blind controlled study. Methods: 35 patients hospitalised with ECOPD and treated according to international guidelines (including systemic steroids) were randomised to receive or not to receive low-dose oral theophylline (100 mg twice daily). Before treatment and 3 months after discharge, HDAC and nuclear factor-kB (NF-kB) activity in sputum macrophages, the concentration of nitric oxide in exhaled air (eNO) and total antioxidant status (TAS), tumour necrosis factor a (TNFa), interleukin (IL)-6 and IL8 levels in sputum supernatants were measured. Results: Patients receiving standard therapy showed decreased NF-kB activity, eNO concentration and sputum levels of TNFa, IL6 and IL8, as well as increased TAS during recovery of ECOPD, but HDAC activity did not change. The addition of low-dose theophylline increased HDAC activity and further reduced IL8 and TNFa concentrations. Conclusions: During ECOPD, low-dose theophylline increases HDAC activity and improves the anti-inflammatory effects of steroids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Exercise improves insulin resistance and is a first line for the prevention and treatment of type 2 diabetes. The extent, however, to which these responses are dose dependent is not known. The purpose of this study was to examine whether exercise dose was associated with improvements in insulin sensitivity after 4 months of exercise training in previously sedentary adults. METHODS: Fifty-five healthy volunteers participated in a 16-wk supervised endurance exercise intervention with a pre/postintervention design. Insulin sensitivity was assessed by euglycemic hyperinsulinemic clamp, peak oxygen uptake by a graded exercise test, and body composition by dual-energy x-ray absorptiometry. The exercise intervention consisted of three to five sessions per week with a minimum of three sessions supervised. A ramped exercise prescription protocol was used to achieve 75% of peak HR for 45 min per session. Exercise dose, expressed as average kilocalories expended per week, was computed as the product of exercise intensity, duration and frequency. RESULTS: Improved insulin sensitivity was significantly related to exercise dose in a graded dose-response relationship. No evidence of threshold or maximal dose-response effect was observed. Age and gender did not influence this dose-response relationship. Exercise intensity was also significantly related to improvements in insulin sensitivity, whereas frequency was not. CONCLUSIONS: This study identifies a graded dose-response relationship between exercise dose and improvements in insulin sensitivity. The implication of this observation is of importance for the adaptation of exercise prescription in clinical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: BK virus associated nephropathy occurs in 1-10% of kidney transplant recipients and may be a cause of graft loss. This infection is difficult to manage because of the absence of specific therapy. Cidofovir, a DNA polymerase inhibitor approved for the treatment of CMV retinitis, has shown in vitro activity against BK virus and some clinical efficacy when used at low-dose in uncontrolled series. Objective: To assess the efficacy of low-dose Cidofovir in the treatment of BK virus associated nephropathy. Method: Two adult kidney transplant recipients with biopsy-proven BK nephropathy and persistent high viremia (>10,000 copies/ml) despite 3-month reduction of immunosuppressive therapy were treated by Cidofovir 0.5 mg/kg fortnightly for a total of 16 weeks (8 doses). Clinical response was assessed by following BK viremia. Results: No decrease in BK viremia was observed at any point during cidofovir therapy (see figure). Creatinine clearance remained stable during therapy and no side-effects of Cidofovir were observed. Conclusions: Low-dose Cidofovir therapy was not associated with a clearance or with a significant decrease of BK viremia. This pilot study does not confirm previous reports suggesting clinical efficacy of Cidofovir for BK virus associated nephropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D dose reconstruction is a verification of the delivered absorbed dose. Our aim was to describe and evaluate a 3D dose reconstruction method applied to phantoms in the context of narrow beams. A solid water phantom and a phantom containing a bone-equivalent material were irradiated on a 6 MV linac. The transmitted dose was measured by using one array of a 2D ion chamber detector. The dose reconstruction was obtained by an iterative algorithm. A phantom set-up error and organ interfraction motion were simulated to test the algorithm sensitivity. In all configurations convergence was obtained within three iterations. A local reconstructed dose agreement of at least 3% / 3mm with respect to the planned dose was obtained, except in a few points of the penumbra. The reconstructed primary fluences were consistent with the planned ones, which validates the whole reconstruction process. The results validate our method in a simple geometry and for narrow beams. The method is sensitive to a set-up error of a heterogeneous phantom and interfraction heterogeneous organ motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract We report here the long-term outcome of autologous stem cell transplant in peripheral T-cell lymphoma (PTCL). Forty-three consecutive patients with PTCL diagnosed between 2000 and 2011 were treated with high-dose chemotherapy (HDCT) and autologous stem cell transplant (ASCT) in our center. Diagnoses included PTCL-not otherwise specified (n = 19), anaplastic large cell lymphoma (n = 11), angioimmunoblastic T-cell lymphoma (n = 5), enteropathy-associated T-cell lymphoma (n = 5) and other rare subtypes (n = 3). Thirty-six patients with a median age of 50 years (range 22-65) were transplanted in first response and seven after relapse. After a median follow-up of 63 months, estimated overall survival at 12 years was 40%, progression-free survival at 12 years was 34% and event-free survival at 12 years was 30%. On univariate analysis, age less than 50 years and no B symptoms at diagnosis were significantly associated with prolonged overall and progression-free-survival. HDCT/ASCT for peripheral T-cell lymphoma can lead to long-term survival for patients responding to induction chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efavirenz dosage adjustment in several patients with high EFV levels and presenting CNS toxicity have been successfully achieved in Switerland over the past seven years but many others have not beneficiated from dosage reduction owing to the lack of prospective studies evaluating the safety and clinical benefit of reduced dosage regimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Optimal valganciclovir (VGC) dosage and duration for cytomegalovirus (CMV) prophylaxis in kidney transplant recipients remains controversial. This study aimed to determine GCV blood levels and efficacy/safety observed under low-dose oral VGC in kidney transplant recipients. Secondly, to quantify the variability of GCV blood levels, and its potential clinical impact. Methods: In this prospective study, each patient at risk for CMV undergoing kidney transplantation received low-dose VGC (450 mg qd) prophylaxis for 3 months, unless GFR was below 40 mL/min, in which case the dose was adapted to 450 mg every other day. GCV levels, at trough (Ctrough) and at peak (C3h) were measured monthly and CMV viremia was assessed during and after prophylaxis using real time quantitative Polymerase Chain Reaction. Adverse effects were recorded on each GCV sampling. Patients were followed up to one year after transplantation. Results: 38 kidney recipients (19 D+/R+, 11 D+/R-, 8 D-/R+) received 3-month VGC prophylaxis. Most patients (mean GFR of 59 mL/min) received 450 mg qd but the dose was reduced to 450 mg every other day in 6 patients with mean GFR of 22 mL/min. Average GCV C3h and Ctrough (regressed at 24h or 48h) were 3.9 mg/L (CV 33%, range: 1.3-8.2) and 0.4 mg/L (CV 111%, range 0.1-3.3). Population pharmacokinetic analysis showed a fair dispersion of the parameters mainly influenced by renal function. Despite this variability, patients remained aviremic during VGC prophylaxis. Neutropenia and thrombocytopenia (grade 2-4) were reported in 4% and 3% of patients respectively. During follow-up, asymptomatic CMV viremia was reported in 25% patients. One year after transplantation, 12% patients (all D+/R-) had developed a CMV disease, which was treated with a therapeutic 6-week course of oral VGC. Conclusion: Average GCV blood levels after oral administration of low-dose VGC in kidney transplant recipients were comparable to those previously reported with oral GCV prophylaxis, efficacious and well tolerated. Thus, a 3-month course of low-dose VGC is appropriate for the renal function of most kidney transplant recipients.