925 resultados para COMBINED HYPERLIPIDEMIA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Timing effects of radioimmunotherapy (RIT) combined with external-beam radiotherapy (RT) were assessed in human colon carcinoma xenografts. Initially, dose effects of fractionated RT and RIT were evaluated separately. Then, 30 Gy RT (10 fractions over 12 days) were combined with three weekly i.v. injections of 200 microCi of 131I-labeled anti-carcinoembryonic antigen monoclonal antibodies in four different treatment schedules. RIT was given either prior to, concurrently, immediately after, or 2 weeks after RT administration. The longest regrowth delay (RD) of 105 days was observed in mice treated by concurrent administration of RT and RIT, whereas the RDs of RT and RIT alone were 34 and 20 days, respectively. The three sequential combination treatments produced significantly shorter RDs ranging from 62 to 70 days. The tumor response represented by the minimal volume (MV) also showed that concurrent administration of RT and RIT gave the best result, with a mean MV of 4.5% as compared to MVs from 26 to 53% for the three sequential treatments. The results were confirmed in a second experiment, in which a RT of 40 Gy was combined with an identical RIT as above (three injections of 200 microCi of 131I-labeled monoclonal antibodies). At comparable toxicity levels, the maximum tolerated RT or RIT alone gave shorter RDs and less tumor shrinkage compared to simultaneous RT+ RIT. These results may be useful for designing clinical protocols of combined RIT and RT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined report on the institutions under the control of the Iowa Department of Corrections for the year ending June 30, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined report on the institutions under the control of the Iowa Department of Human Services for the year ended June 30, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined report on the eight Judicial District Departments of Correctional Services for the year ended June 30, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY OBJECTIVE: To evaluate the safety of a combined heat and moisture exchanger filter (HMEF) for the conditioning of inspired gas in long-term mechanical ventilation (MV). DESIGN: Randomized controlled trial. SETTING: Medical ICU in a large teaching hospital. PATIENTS: One hundred fifteen consecutive patients who required > or = 48 h of MV. INTERVENTIONS: Patients were randomized at intubation time (day 1) to receive inspired gas conditioned either by a water-bath humidifier heated at 32 degrees C (HWBH) or by an HMEF (Hygroster; DAR; Mirandola, Italy). MEASUREMENTS AND MAIN RESULTS: The two study groups were comparable in terms of primary pathologic condition at the time of hospital admission, disease severity as measured by the Simplified Acute Physiology Score, and ICU mortality. They did not differ with respect to ventilator days per patient (mean +/- SD: HMEF, 7.6 +/- 6.5; HWBH, 7.8 +/- 5.8), incidence of endotracheal tube obstruction (HMEF, 0/59; HWBH, 1/56), and incidence of hypothermic episodes (HMEF, five; HWBH, two). In 41 patients receiving MV for > or = 5 days, the morphologic integrity of respiratory epithelium was evaluated on day 1 and day 5, using a cytologic examination of tracheal aspirate smears. The state of ciliated epithelium was scored on a scale from 0 (poorest integrity) to 1,200 (maximum integrity), according to a well-described method. In both patient groups, the scores slightly but significantly decreased from day 1 to day 5 (mean +/- SD: HWBH, from 787 +/- 104 to 745 +/- 88; HMEF, from 813 +/- 79 to 739 +/- 62; p < 0.01 for both groups); there were no statistically significant differences between groups. CONCLUSIONS: These data indicate acceptable safety of HMEFs of the type used in the present study for long-term mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Sorafenib (Sb) is a multiple kinase inhibitor targeting both tumour cell proliferation and angiogenesis that may further act as a potent radiosensitizer by arresting cells in the most radiosensitive cell cycle phase. This phase I open-label, noncontrolled dose escalation study was performed to determine the safety and maximum tolerated dose (MTD) of Sb in combination with radiation therapy (RT) and temozolomide (TMZ) in 17 patients with newly diagnosed high-grade glioma. METHODS: Patients were treated with RT (60 Gy in 2 Gy fractions) combined with TMZ 75 mg m(-2) daily, and Sb administered at three dose levels (200 mg daily, 200 mg BID, and 400 mg BID) starting on day 8 of RT. Thirty days after the end of RT, patients received monthly TMZ (150-200 mg m(-2) D1-5/28) and Sb (400 mg BID). Pharmacokinetic (PK) analyses were performed on day 8 (TMZ) and on day 21 (TMZ&Sb) (Clinicaltrials ID: NCT00884416). RESULTS: The MTD of Sb was established at 200 mg BID. Dose-limiting toxicities included thrombocytopenia (two patients), diarrhoea (one patient) and hypercholesterolaemia (one patient). Sb administration did not affect the mean area under the curve(0-24) and mean Cmax of TMZ and its metabolite 5-amino-imidazole-4-carboxamide (AIC). Tmax of both TMZ and AIC was delayed from 0.75 (TMZ alone) to 1.5 h (combined TMZ/Sb). The median progression-free survival was 7.9 months (95% confidence interval (CI): 5.4-14.55), and the median overall survival was 17.8 months (95% CI: 14.7-25.6). CONCLUSIONS: Although Sb can be combined with RT and TMZ, significant side effects and moderate outcome results do not support further clinical development in malignant gliomas. The robust PK data of the TMZ/Sb combination could be useful in other cancer settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the design, calibration, and performance of surface forces apparatus with the capability of illumination of the contact interface for spectroscopic investigation using optical techniques. The apparatus can be placed in the path of a Nd-YAG laser for studies of the linear response or the second harmonic and sum-frequency generation from a material confined between the two surfaces. In addition to the standard fringes of equal chromatic order technique, which we have digitized for accurate and fast analysis, the distance of separation can be measured with a fiber-optic interferometer during spectroscopic measurements (2 Å resolution and 10 ms response time). The sample approach is accomplished through application of a motor drive, piezoelectric actuator, or electromagnetic lever deflection for variable degrees of range, sensitivity, and response time. To demonstrate the operation of the instrument, the stepwise expulsion of discrete layers of octamethylcyclotetrasiloxane from the contact is shown. Lateral forces may also be studied by using piezoelectric bimorphs to induce and direct the motion of one surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined liver-kidney transplantation is considered a low risk for immunologic complication. We report an unusual case of identical ABO liver-kidney recipient without preformed anti-human leukocyte antigen (HLA) antibodies, transplanted across a T- and B-cell-negative cross-match and complicated by early acute humoral and cellular rejection, first in the liver then in the kidney. While analyzing the immunologic complications in our cohort of 12 low-risk combined liver-kidney recipients, only one recipient experienced a rejection episode without detection of anti-HLA antibody over time. Although humoral or cellular rejection is rare after combined kidney-liver transplantation, our data suggest that even in low-risk recipients, the liver does not always systematically protect the kidney from acute rejection. Indeed, the detection of C4d in the liver should be carefully followed after combined liver-kidney transplantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumor progression is facilitated by regulatory T cells (Treg) and restricted by effector T cells. In this study, we document parallel regulation of CD8(+) T cells and Foxp3(+) Tregs by programmed death-1 (PD-1, PDCD1). In addition, we identify an additional role of CTL antigen-4 (CTLA-4) inhibitory receptor in further promoting dysfunction of CD8(+) T effector cells in tumor models (CT26 colon carcinoma and ID8-VEGF ovarian carcinoma). Two thirds of CD8(+) tumor-infiltrating lymphocytes (TIL) expressed PD-1, whereas one third to half of CD8(+) TIL coexpressed PD-1 and CTLA-4. Double-positive (PD-1(+)CTLA-4(+)) CD8(+) TIL had characteristics of more severe dysfunction than single-positive (PD-1(+) or CTLA-4(+)) TIL, including an inability to proliferate and secrete effector cytokines. Blockade of both PD-1 and CTLA-4 resulted in reversal of CD8(+) TIL dysfunction and led to tumor rejection in two thirds of mice. Double blockade was associated with increased proliferation of antigen-specific effector CD8(+) and CD4(+) T cells, antigen-specific cytokine release, inhibition of suppressive functions of Tregs, and upregulation of key signaling molecules critical for T-cell function. When used in combination with GVAX vaccination (consisting of granulocyte macrophage colony-stimulating factor-expressing irradiated tumor cells), inhibitory pathway blockade induced rejection of CT26 tumors in 100% of mice and ID8-VEGF tumors in 75% of mice. Our study indicates that PD-1 signaling in tumors is required for both suppressing effector T cells and maintaining tumor Tregs, and that PD-1/PD-L1 pathway (CD274) blockade augments tumor inhibition by increasing effector T-cell activity, thereby attenuating Treg suppression. Cancer Res; 73(12); 3591-603. ©2013 AACR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Airway stenting is a common endoscopic procedure that is used to treat a variety of central airway lesions. Obstructions or fistulas involving the carina or nearby tracheobronchial structures require the use of specially designed stents, commonly referred to as Y-stents. Conventional methods of endobronchial Y-stent delivery are all characterized by a blind and apneic period during the procedure that carries the risk of stent misplacement or ventilation/oxygenation problems or both. Using combined suspension laryngoscopy, flexible bronchoscopy, and jet ventilation, we describe a technique that makes challenging bronchoscopic interventions--such as self-expandable Y-shaped airway stent delivery--easy, precise, and safe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined report on the institutions under the control of the Iowa Department of Corrections for the five years ended June 30, 2011