998 resultados para Análise de flutuação sem tendências


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Changes in heart rate during rest-exercise transition can be characterized by the application of mathematical calculations, such as deltas 0-10 and 0-30 seconds to infer on the parasympathetic nervous system and linear regression and delta applied to data range from 60 to 240 seconds to infer on the sympathetic nervous system. The objective of this study was to test the hypothesis that young and middle-aged subjects have different heart rate responses in exercise of moderate and intense intensity, with different mathematical calculations. METHODS: Seven middle-aged men and ten young men apparently healthy were subject to constant load tests (intense and moderate) in cycle ergometer. The heart rate data were submitted to analysis of deltas (0-10, 0-30 and 60-240 seconds) and simple linear regression (60-240 seconds). The parameters obtained from simple linear regression analysis were: intercept and slope angle. We used the Shapiro-Wilk test to check the distribution of data and the t test for unpaired comparisons between groups. The level of statistical significance was 5%. RESULTS: The value of the intercept and delta 0-10 seconds was lower in middle age in two loads tested and the inclination angle was lower in moderate exercise in middle age. CONCLUSION: The young subjects present greater magnitude of vagal withdrawal in the initial stage of the HR response during constant load exercise and higher speed of adjustment of sympathetic response in moderate exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extract of stevia leaves (Stevia rebaudiana Bertoni) is the only sweetener utilized in sucrose substitution which can be produced totally in Brazil. The objective of this study, was determine the temporal characteristic of sweet and bitter taste of stevia and compare with sucrose at 3 and 10% in the same equi-sweet. The time-intensity curves (T-I) for each substance were collected through the software Sistema de Coleta de Dados Tempo-Intensidade - SCDTI for Windows, where the judges recorded through of mouse the perception of each stimuli inside function of time, for each sample. The parameters of T-I curves collected were: time for intensity maxim (TImax), intensity maxim (Imax), time of decay (Td), time of plato (Platô), area under curve (Area) and total time of stimuli duration (Ttot). The parameters Td, Ttot, Area e Plato of T-I curves, for stimuli sweet in both sweetness level, were significativelly superior for stevia, while Timax e Imax were significativelly inferior (p£0,05), at differences between value for both substances were superior DESS at 10%. Sucrose didn?t present any record for simuli bitter as 3 as 10%, while stevia presented a characteristic T-I curve with intensity and total time of stimuli duration dependent of concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazilian regulations prohibit the addition of cocoa butter replacements to chocolate, in total or partial substitution. The objective of the present work was to check the quality standards of four of coating bitter Brasilian chocolate bars and five of coating milk chocolate bars, commercialized in Campinas. In order to check the possible addition of substitutes, the triacylglycerol composition was determined, and the results were analysed by Padley & Timms mathematical method. The triacylglycerol composition of each sample was determined by high temperature gas chromatography (HTGC). The presence of cocoa butter replacements was not detected in the brands of coating chocolate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Descriptive terminology and sensory profile of three varieties of brazilian varietal white wines (cultivars Riesling, Gewürztraminer and Chardonnay) were developed by a methodology based on the Quantitative Descriptive Analysis (QDA). The sensory panel consensually defined the sensory descriptors, their respective reference materials and the descriptive evaluation ballot. Ten individuals were selected as judges based on their discrimination, reproducibility and individual consensus with the sensory panel. Twelve descriptors were generated showing similarities and differences among the wine samples. Each descriptor was evaluated using a nine-centimeters non-structured scale with the intensity terms anchored at its ends. The collected data were analysed by ANOVA, Tukey test and Principal Component Analysis (PCA). The results showed a great difference within the sensory profile of Riesling and Gewürztraminer wines, whereas Chardonnay wines showed a lesser variation. PCA separated samples into two groups: a first group formed by wines higher in sweetness and fruitty flavor and aroma; and a second group of wines higher in sourness, adstringency, bitterness, alcoholic and fermented flavors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the mean critical fusion frequency and the short-term fluctuation, to analyze the influence of age, gender, and the learning effect in healthy subjects undergoing flicker perimetry. METHODS: Study 1 - 95 healthy subjects underwent flicker perimetry once in one eye. Mean critical fusion frequency values were compared between genders, and the influence of age was evaluated using linear regression analysis. Study 2 - 20 healthy subjects underwent flicker perimetry 5 times in one eye. The first 3 sessions were separated by an interval of 1 to 30 days, whereas the last 3 sessions were performed within the same day. The first 3 sessions were used to investigate the presence of a learning effect, whereas the last 3 tests were used to calculate short-term fluctuation. RESULTS: Study 1 - Linear regression analysis demonstrated that mean global, foveal, central, and critical fusion frequency per quadrant significantly decreased with age (p<0.05).There were no statistically significant differences in mean critical fusion frequency values between males and females (p>0.05), with the exception of the central area and inferonasal quadrant (p=0.049 and p=0.011, respectively), where the values were lower in females. Study 2 - Mean global (p=0.014), central (p=0.008), and peripheral (p=0.03) critical fusion frequency were significantly lower in the first session compared to the second and third sessions. The mean global short-term fluctuation was 5.06±1.13 Hz, the mean interindividual and intraindividual variabilities were 11.2±2.8% and 6.4±1.5%, respectively. CONCLUSION: This study suggests that, in healthy subjects, critical fusion frequency decreases with age, that flicker perimetry is associated with a learning effect, and that a moderately high short-term fluctuation is expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física