959 resultados para total hip prostheses


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of different methods and materials should be considered during the planning of implant-supported prostheses. Complications such as fractures of the acrylic resin base, wear and fracture of teeth can occur frequently, creating the need for careful planning for each patient, which can make the selection of the type of treatment more complex. Thus, this article describes the oral rehabilitation of a completely edentulous patient with bimaxillary fixed implant-supported prosthesis, with complaints on aesthetics, loss of vertical dimension and fracture of acrylic resin teeth of the upper arch. After the restoration of vertical dimension, his dentures were replaced with new bimaxillary implant-supported fixed prostheses, ceramic and acrylic resin were used as veneering material for maxilla and mandible, respectively. At the end of the treatment, the patient received bimaxillary flat occlusal splints to protect the teeth and implants of possible parafunctional habits. The approach for the treatment allowed a quick and effective resolution, with aesthetic and functional outcomes very favorable for the patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the association between serum levels of 25(OH) vitamin D-3 with midupper arm muscle circumference (MUAMC), handgrip strength and length of hospital stay (LOS) after hip fracture.Methods: In total, 102 consecutive patients with hip fracture over the age of 65 were admitted to the orthopedic unit and prospectively evaluated. All of the patients were treated according to specific protocols depending on the type of fracture. Anthropometric measurements and handgrip strength were performed, and blood samples were taken for serum biochemistry and 25(OH) vitamin D-3 analysis within the first 72 h of admission. All of the patients were followed during their hospital stay, and the length of stay was recorded.Results: Of the patients, two were excluded because of pathologic fractures. In total, 100 patients with a mean age of 80 +/- 7 y were included in the analysis. Among these patients, 73% were female, and 37% had vitamin D deficiency. The median LOS was 7 (5-11) d. Patients with vitamin D deficiency had lower handgrip strength in univariate analysis. In the multiple linear regression analysis with robust standard error, serum vitamin D levels adjusted by age and sex were associated with handgrip strength but not with MUAMC and LOS after hip fracture.Conclusions: In conclusion, vitamin D serum levels were associated with handgrip strength but not with muscle mass or length of hospital stay after hip fracture. (C) 2015 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The immediate complete denture is a prostheses made prior to teeth extraction, that aims to re-establish the patient aesthetics and function immediately after the removal of the remaining teeth. The objective of this paper is to report the technical procedures during the manufacture of immediate prosthesis. The study reports the clinical steps prior to teeth extraction as well as the surgical and maintenance procedures. The immediate complete denture is a viable rehabilitation method, especially to restore patients’ self-esteem, aesthetics and function promptly. An accurate planning and manufactory beholds better results

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The modalities of treatment with prostheses over implants for total edentulous patients can be divided in fixed and removable prostheses (overdentures). The fixed prostheses modality has proven to offer better results as to the functional aspects and, results in higher longevity. Overdentures are considered as a modality of rehabilitation utilized to compensate the need for better retention, aside from augmenting chewing efficiency. Its use is justified by its facilitated hygiene, reduced surgical and prosthetic costs, reestablishment of labial support and elimination of the possibility of air escape. However, this option presents psychosocial downside, since the fact that it is considered a removable rehabilitation modality does not please the majority of patients. Although many patients prefer a fixed implant-supported prosthesis to a removable overdenture, frequently it is necessary to utilize an implant retained overdenture as an alternative to the treatment, due to anatomical, physiological, aesthetic, hygienic, and financial limitations regarding the patient. The objective of this study was to discuss a clinical case of a partially edentulous patient treated in the Implantodontic Surgery Post-Graduation Course from the Kenedy Dentistry Institute Mozarteum/Famosp Unit – Goiânia-Brazil), and submitted to osseointegrated implants surgical fixation techniques. A modality of differential diagnosis was established after osseointegration period, it aimed at facilitating the choice of a rehabilitation model that could favor the patient’s and professional`s expectations. Therefore the appreciated aspects were function, comfort, aesthetics, and especially the patient satisfaction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context. The Sun shows abundance anomalies relative to most solar twins. If the abundance peculiarities are due to the formation of inner rocky planets, that would mean that only a small fraction of solar type stars may host terrestrial planets. Aims. In this work we study HIP 56948, the best solar twin known to date, to determine with an unparalleled precision how similar it is to the Sun in its physical properties, chemical composition and planet architecture. We explore whether the abundances anomalies may be due to pollution from stellar ejecta or to terrestrial planet formation. Methods. We perform a differential abundance analysis (both in LTE and NLTE) using high resolution (R similar to 100 000) high S/N (600-650) Keck HIRES spectra of the Sun (as reflected from the asteroid Ceres) and HIP 56948. We use precise radial velocity data from the McDonald and Keck observatories to search for planets around this star. Results. We achieve a precision of sigma less than or similar to 0.003 dex for several elements. Including errors in stellar parameters the total uncertainty is as low as sigma similar or equal to 0.005 dex (1%), which is unprecedented in elemental abundance studies. The similarities between HIP 56948 and the Sun are astonishing. HIP 56948 is only 17 +/- 7 K hotter than the Sun, and log g, [Fe/H] and microturbulence velocity are only +0.02 +/- 0.02 dex, +0.02 +/- 0.01 dex and +0.01 +/- 0.01 km s(-1) higher than solar, respectively. Our precise stellar parameters and a differential isochrone analysis shows that HIP 56948 has a mass of 1.02 +/- 0.02 M-circle dot and that it is similar to 1 Gyr younger than the Sun, as constrained by isochrones, chromospheric activity, Li and rotation. Both stars show a chemical abundance pattern that differs from most solar twins, but the refractory elements (those with condensation temperature T-cond greater than or similar to 1000 K) are slightly (similar to 0.01 dex) more depleted in the Sun than in HIP 56948. The trend with T-cond in differential abundances (twins -HIP 56948) can be reproduced very well by adding similar to 3 M-circle plus of a mix of Earth and meteoritic material, to the convection zone of HIP 56948. The element-to-element scatter of the Earth/meteoritic mix for the case of hypothetical rocky planets around HIP 56948 is only 0.0047 dex. From our radial velocity monitoring we find no indications of giant planets interior to or within the habitable zone of HIP 56948. Conclusions. We conclude that HIP 56948 is an excellent candidate to host a planetary system like our own, including the possible presence of inner terrestrial planets. Its striking similarity to the Sun and its mature age makes HIP 56948 a prime target in the quest for other Earths and SETI endeavors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare the existence of radiographic abnormalities in two groups of patients, those with and without hip pain. METHODS: A total 222 patients were evaluated between March 2007 and April 2009; 122 complained of groin pain, and 100 had no symptoms. The individuals in both groups underwent radiographic examinations of the hip using the following views: anteroposterior, Lequesne false profile, Dunn, Dunn 45º, and Ducroquet. RESULTS: A total of 1110 radiographs were evaluated. Female patients were prevalent in both groups (52% symptomatic, 58% asymptomatic). There were statistically significant differences between the groups in age (p<0.0001), weight (p = 0.002) and BMI (p = 0.006). The positive findings in the group with groin pain consisted of the presence of a bump on the femoral head in the anteroposterior view (p<0.0001) or in the Dunn 45º view (p = 0.008). The difference in the a angle in the anteroposterior, Dunn, Dunn 45º, and Ducroquet views for all of the cases studied was p,0.0001. The joint space measurement differed significantly between groups in the Lequesne view (p = 0.007). The Lequesne anteversion angle (ρ) and the femoral offset measurement also differed significantly (p = 0.005 and p = 0.0001, respectively). CONCLUSIONS: We conclude that the best views for diagnosing a femoroacetabular impingement are the anteroposterior pelvic orthostatic, the Dunn 45º, and the Ducroquet views. The following findings correlated with hip pain: a decrease in the femoral offset, an increase in the α angle, an increase in the Lequesne ρ angle, a decrease in the CE angle of Wiberg, a thinner articular space and the presence of a bump on the femoral head-neck transition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last years the number of shoulder arthroplasties has been increasing. Simultaneously the study of their shape, size and strength and the reasons that bring to a possible early explantation have not yet been examined in detail. The research carried out directly on explants is practically nonexistent, this means a poor understanding of the mechanisms leading the patient and so the surgeon, to their removal. The analysis of the mechanisms which are the cause of instability, dislocation, broken, fracture, etc, may lead to a change in the structure or design of the shoulder prostheses and lengthen the life of the implant in situ. The idea was to analyze 22 explants through three methods in order to find roughness, corrosion and surface wear. In the first method, the humeral heads and/or the glenospheres were examined with the interferometer, a machine that through electromagnetic waves gives information about the roughness of the surfaces under examination. The output of the device was a total profile containing both roughness and information on the waves (representing the spatial waves most characteristic on the surface). The most important value is called "roughness average" and brings the average value of the peaks found in the local defects of the surfaces. It was found that 42% of the prostheses had considerable peak values in the area where the damage was caused by the implant and not only by external events, such as possibly the surgeon's hand. One of the problems of interest in the use of metallic biomaterials is their resistance to corrosion. The clinical significance of the degradation of metal implants has been the purpose of the second method; the interaction between human body and metal components is critical to understand how and why they arrive to corrosion. The percentage of damage in the joints of the prosthetic components has been calculated via high resolution photos and the software ImageJ. The 40% and 50% of the area appeared to have scratches or multiple lines due to mechanical artifacts. The third method of analysis has been made through the use of electron microscopy to quantify the wear surface in polyethylene components. Different joint movements correspond to different mechanisms of damage, which were imprinted in the parts of polyethylene examined. The most affected area was located mainly in the side edges. The results could help the manufacturers to modify the design of the prostheses and thus reduce the number of explants. It could also help surgeons in choosing the model of the prosthesis to be implanted in the patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased total offset and limb shortening. Acetabular offset and height had a greater effect on ROMBI than femoral offset and height. The ROMBI lost with decreased acetabular offset was not fully recoverable with an increase in femoral offset or osteophyte removal. Bony impingement increased and component impingement decreased with decreased acetabular offset and increased head diameter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine the prevalence of cam-type deformities on hip magnetic resonance imaging (MRI) in young males. Methods This was a population-based cross-sectional study in young asymptomatic male individuals who underwent clinical examination and completed a self-report questionnaire. A random sample of participants was invited for MRI of the hip. We graded the maximal offset at the femoral head–neck junction on radial sequences using grades from 0 to 3, where 0 = normal, 1 = possible, 2 = definite, and 3 = severe deformity. The prespecified main analyses were based on definite cam-type deformity grades 2 or 3. We estimated the prevalence of the cam-type deformity adjusted for the sampling process overall and according to the extent of internal rotation. Then we determined the location of the deformity on radial MRI sequences. Results A total of 1,080 subjects were included in the study and 244 asymptomatic males with a mean age of 19.9 years attended MRI. Sixty-seven definite cam-type deformities were detected. The adjusted overall prevalence was 24% (95% confidence interval [95% CI] 19–30%). The prevalence increased with decreasing internal rotation (P < 0.001 for trend). Among those with a clinically decreased internal rotation of <30°, the estimated prevalence was 48% (95% CI 37–59%). Sixty-one of 67 cam-type deformities were located in an anterosuperior position. Conclusion Cam-type deformities can be found on MRI in every fourth young asymptomatic male individual and in every second male with decreased internal rotation. The majority of deformities are located in an anterosuperior position.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The objective of this review was to systematically screen the literature for data related to the survival and complication rates observed with dental or implant double crown abutments and removable prostheses under functional loading for at least 3 years. Materials and Methods: A systematic review of the dental literature from January 1966 to December 2009 was performed in electronic databases (PubMed and Embase) as well as by an extensive hand search to investigate the clinical outcomes of double crown reconstructions. Results: From the total of 2412 titles retrieved from the search, 65 were selected for full-text review. Subsequently, 17 papers were included for data extraction. An estimation of the cumulative survival and complication rates was not feasible due to the lack of detailed information. Tooth survival rates for telescopic abutment teeth ranged from 82.5% to 96.5% after an observation period of 3.4 to 6 years, and for tooth-supported double crown retained dentures from 66.7% to 98.6% after an observation period of 6 to 10 years. The survival rates of implants were between 97.9% and 100% and for telescopic-retained removable dental prostheses with two mandibular implants, 100% after 3.0 and 10.4 years. The major biological complications affecting the tooth abutments were gingival inflammation, periodontal disease, and caries. The most frequent technical complications were loss of cementation and loss of facings. Conclusions: The main findings of this review are: (I) double crown tooth abutments and dentures demonstrated a wide range of survival rates. (II) Implant-supported mandibular overdentures demonstrated a favorable long-term prognosis. (III) A greater need for prosthetic maintenance is required for both tooth-supported and implant-supported reconstructions. (IV) Future areas of research would involve designing appropriate longitudinal studies for comparisons of survival and complication rates of different reconstruction designs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Swiss Federal Office of Public Health demanded a nationwide HTA-registry for cervical total disc arthroplasty (TDA), to decide about its reimbursement. The goal of the SWISSspine registry is to generate evidence about the safety and efficiency of cervical TDA. MATERIALS AND METHODS: Three hundred thirty-two cases treated between 3.2005 and 6.2006 who were eligible for 5 years follow-ups were included in the study. Follow-up rates for 3-6 months, 1, 2 and 5 years were 84.6, 74.4, 50.6 and 64.8 %, respectively. Outcome measures were neck and arm pain, medication, quality of life, intraoperative and postoperative complication and revision rates. In addition, segmental mobility, ossification, adjacent and distant segment degeneration were analyzed at the 5-year follow-up. RESULTS: There was significant, clinically relevant and lasting reduction of neck (preop/postop 60/21 VAS points) and arm pain (preop/postop VAS 67/17) and a consequently decreased analgesics consumption and quality of life improvement (preop/postop 0.39/0.82 EQ-5D points) until the 5-year follow-up. The rates for intraoperative and early postoperative complications were 0.6 and 7.2 %, respectively. In 0.6 % an early and in 3.9 % a late revision surgery was performed. At the 5-year follow-up, the average range of motion of the mobile segments (88.2 %) was 10.2°. In 40.7 % of the patients osteophytes at least potentially affecting range of motion were seen. CONCLUSIONS: Cervical TDA appeared as safe and efficient in long-term pain alleviation, consequent reduction of pain killer consumption and in improvement of quality of life. The improvement is stable over the 5 years postoperative period. The vast majority of treated segments remained mobile after 5 years, although 40.7 % of patients showed osteophytes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Define links between psychosocial parameters and metabolic variables in obese females before and after a low-calorie diet. METHOD: Nine female obese patients (age 36.1 +/- 7.1 years, body mass index [BMI] > 30 kg/m2) were investigated before and after a 6-week low-calorie diet accompanied by behavior therapy. Blood lipids, insulin sensitivity (Bergman protocol), fat distribution (by dual-energy X-ray absorptiometry [DEXA]), as well as psychological parameters such as depression, anger, anxiety, symptom load, and well-being, were assessed before and after the dieting period. RESULTS: The females lost 9.6 +/- 2.8 kg (p < .0001) of body weight, their BMI was reduced by 3.5 +/- 0.3 kg/m2 (p < .0001), and insulin sensitivity increased from 3.0 +/- 1.8 to 4.3 +/- 1.5 mg/kg (p = .05). Their abdominal fat content decreased from 22.3 +/- 5.5 to 18.9 +/- 4.5 kg (p < .0001). In parallel, psychological parameters such as irritability (p < .05) and cognitive control (p < .0001) increased, whereas feelings of hunger (p < .05), externality (p < .05), interpersonal sensitivity (p < .01), paranoid ideation (p < .05), psychoticism (p < .01), and global severity index (p < .01) decreased. Prospectively, differences in body fat (percent) were correlated to nervousness (p < .05). Waist-to-hip ratio (WHR) differences were significantly correlated to sociability (p < .05) and inversely to emotional instability (p < .05), whereas emotional instability was inversely correlated to differences in insulin sensitivity (p < .01). DISCUSSION: Weight reduction may lead to better somatic risk factor control. Women with more nervousness and better sociability at the beginning of a diet period may lose more weight than others.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SWISSspine is a so-called pragmatic trial for assessment of safety and efficiency of total disc arthroplasty (TDA). It follows the new health technology assessment (HTA) principle of "coverage with evidence development". It is the first mandatory HTA registry of its kind in the history of Swiss orthopaedic surgery. Its goal is the generation of evidence for a decision by the Swiss federal office of health about reimbursement of the concerned technologies and treatments by the basic health insurance of Switzerland. During the time between March 2005 and 2008, 427 interventions with implantation of 497 lumbar total disc arthroplasties have been documented. Data was collected in a prospective, observational multicenter mode. The preliminary timeframe for the registry was 3 years and has already been extended. Data collection happens pre- and perioperatively, at the 3 months and 1-year follow-up and annually thereafter. Surgery, implant and follow-up case report forms are administered by spinal surgeons. Comorbidity questionnaires, NASS and EQ-5D forms are completed by the patients. Significant and clinically relevant reduction of low back pain VAS (70.3-29.4 points preop to 1-year postop, p < 0.0001) leg pain VAS (55.5-19.1 points preop to 1-year postop, p < 0.001), improvement of quality of life (EQ-5D, 0.32-0.73 points preop to 1-year postop, p < 0.001) and reduction of pain killer consumption was revealed at the 1-year follow-up. There were 14 (3.9%) complications and 7 (2.0%) revisions within the same hospitalization reported for monosegmental TDA; there were 6 (8.6%) complications and 8 (11.4%) revisions for bisegmental surgery. There were 35 patients (9.8%) with complications during followup in monosegmental and 9 (12.9%) in bisegmental surgery and 11 (3.1%) revisions with 1 [corrected] new hospitalization in monosegmental and 1 (1.4%) in bisegmental surgery. Regression analysis suggested a preoperative VAS "threshold value" of about 44 points for increased likelihood of a minimum clinically relevant back pain improvement. In a short-term perspective, lumbar TDA appears as a relatively safe and efficient procedure concerning pain reduction and improvement of quality of life. Nevertheless, no prediction about the long-term goals of TDA can be made yet. The SWISSspine registry proofs to be an excellent tool for collection of observational data in a nationwide framework whereby advantages and deficits of its design must be considered. It can act as a model for similar projects in other health-care domains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.