940 resultados para life cycle assessment bio-fuel cell biomass waste LCA biowaste valorization
Resumo:
A stand-alone power system is an autonomous system that supplies electricity to the user load without being connected to the electric grid. This kind of decentralized system is frequently located in remote and inaccessible areas. It is essential for about one third of the world population which are living in developed or isolated regions and have no access to an electricity utility grid. The most people live in remote and rural areas, with low population density, lacking even the basic infrastructure. The utility grid extension to these locations is not a cost effective option and sometimes technically not feasible. The purpose of this thesis is the modelling and simulation of a stand-alone hybrid power system, referred to as “hydrogen Photovoltaic-Fuel Cell (PVFC) hybrid system”. It couples a photovoltaic generator (PV), an alkaline water electrolyser, a storage gas tank, a proton exchange membrane fuel cell (PEMFC), and power conditioning units (PCU) to give different system topologies. The system is intended to be an environmentally friendly solution since it tries maximising the use of a renewable energy source. Electricity is produced by a PV generator to meet the requirements of a user load. Whenever there is enough solar radiation, the user load can be powered totally by the PV electricity. During periods of low solar radiation, auxiliary electricity is required. An alkaline high pressure water electrolyser is powered by the excess energy from the PV generator to produce hydrogen and oxygen at a pressure of maximum 30bar. Gases are stored without compression for short- (hourly or daily) and long- (seasonal) term. A proton exchange membrane (PEM) fuel cell is used to keep the system’s reliability at the same level as for the conventional system while decreasing the environmental impact of the whole system. The PEM fuel cell consumes gases which are produced by an electrolyser to meet the user load demand when the PV generator energy is deficient, so that it works as an auxiliary generator. Power conditioning units are appropriate for the conversion and dispatch the energy between the components of the system. No batteries are used in this system since they represent the weakest when used in PV systems due to their need for sophisticated control and their short lifetime. The model library, ISET Alternative Power Library (ISET-APL), is designed by the Institute of Solar Energy supply Technology (ISET) and used for the simulation of the hybrid system. The physical, analytical and/or empirical equations of each component are programmed and implemented separately in this library for the simulation software program Simplorer by C++ language. The model parameters are derived from manufacturer’s performance data sheets or measurements obtained from literature. The identification and validation of the major hydrogen PVFC hybrid system component models are evaluated according to the measured data of the components, from the manufacturer’s data sheet or from actual system operation. Then, the overall system is simulated, at intervals of one hour each, by using solar radiation as the primary energy input and hydrogen as energy storage for one year operation. A comparison between different topologies, such as DC or AC coupled systems, is carried out on the basis of energy point of view at two locations with different geographical latitudes, in Kassel/Germany (Europe) and in Cairo/Egypt (North Africa). The main conclusion in this work is that the simulation method of the system study under different conditions could successfully be used to give good visualization and comparison between those topologies for the overall performance of the system. The operational performance of the system is not only depending on component efficiency but also on system design and consumption behaviour. The worst case of this system is the low efficiency of the storage subsystem made of the electrolyser, the gas storage tank, and the fuel cell as it is around 25-34% at Cairo and 29-37% at Kassel. Therefore, the research for this system should be concentrated in the subsystem components development especially the fuel cell.
Resumo:
Este trabajo se centra en el análisis de las actividades desarrolladas en torno a los servicios de procesos de impresión que ofrece la organización DATAPOINT de Colombia SAS para identificar los puntos críticos en la gestión de los residuos de impresión y las decisiones tomadas por parte de los involucrados durante todo el proceso (proveedores, clientes y la empresa), con el fin de revisar medidas y estrategias que permitan fortalecer la gestión integral de residuos de impresión a partir de una revisión y comparación de las mejores prácticas planteadas por los actores del sector. También se efectuaron recomendaciones con acciones de mejora que se podrían desarrollar con el fin de mitigar el impacto ambiental generado por estos residuos. Con la finalidad de cumplir con lo planteado se realizó inicialmente un estudio sobre la organización, sus clientes y proveedores para entender de manera integral la cadena de valor en torno a los tóner y su gestión inversa, (explicar) al igual que el entorno normativo tanto de manera nacional como internacional. Posteriormente, se identificaron los puntos de mejora comparando lo planteado por el proveedor versus lo ejecutado por los involucrados en el proceso, labor se realizó en campo con los clientes para entender la situación actual, sus necesidades y en que basan la toma de decisiones relacionada con el manejo de los residuos de impresión. Finalmente se listaran una serie de acciones de mejora y recomendaciones las cuales pueden ser incorporadas a los procesos críticos de DATAPOINT.
Resumo:
Resumen basado en el de la publicación
Resumo:
The life-cycle of shallow frontal waves and the impact of deformation strain on their development is investigated using the idealised version of the Met Office non-hydrostatic Unified Model which includes the same physics and dynamics as the operational forecast model. Frontal wave development occurs in two stages; first, a deformation strain is applied to a front and a positive potential vorticity (PV) strip forms, generated by latent heat release in the frontal updraft; second, as the deformation strain is reduced the PV strip breaks up into individual anomalies. The circulations associated with the PV anomalies cause shallow frontal waves to form. The structure of the simulated frontal waves is consistent with the conceptual model of a frontal cyclone. Deeper frontal waves are simulated if the stability of the atmosphere is reduced. Deformation strain rates of different strengths are applied to the PV strip to determine whether a deformation strain threshold exists above which frontal wave development is suppressed. An objective method of frontal wave activity is defined and frontal wave development was found to be suppressed by deformation strain rates $\ge 0.4\times10^{-5}\mbox{s}^{-1}$. This value compares well with observed deformation strain rate thresholds and the analytical solution for the minimum deformation strain rate needed to suppress barotropic frontal wave development. The deformation strain rate threshold is dependent on the strength of the PV strip with strong PV strips able to overcome stronger deformation strain rates (leading to frontal wave development) than weaker PV strips.
Environmental impact assessment of forest and mining waste interactions in the Tamar River catchment
Resumo:
Two control and eight field-contaminated, metal-polluted soils were inoculated with Eisenia fetida (Savigny, 1826). Three, 7, 14, 21, 28 and 42 days after inoculation, earthworm survival, body weight, cocoon production and hatching rate were measured. Seventeen metals were analysed in E.fetida tissue, bulk soil and soil solution. Soil organic carbon content, texture, pH and cation exchange capacity were also measured. Cocoon production and hatching rate were more sensitive to adverse conditions than survival or weight change. Soil properties other than metal concentration impacted toxicity. The most toxic soils were organic-poor (1-10 g C kg(-1)), sandy soils (c. 74% sand), with intermediate metal concentrations (e.g. 7150-13, 100 mg Ph kg(-1), 2970-53,400 mg Zn kg(-1)). Significant relationships between soil properties and the life cycle parameters were determined. The best coefficients of correlation were generally found for texture, pH, Ag, Cd, Mg, Pb, Tl, and Zn both singularly and in multivariate regressions. Studies that use metal-amended artificial soils are not useful to predict toxicity of field multi-contaminated soils. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
This paper provides some insights on the quasi-biennial oscillation (QBO) modulated 11-year solar cycle (11-yr SC) signals in Northern Hemisphere (NH) winter temperature and zonal wind. Daily ERA-40 Reanalysis and ECMWF Operational data for the period of 1958-2006 were used to examine the seasonal evolution of the QBO-solar cycle relationship at various pressure levels up to the stratopause. The results show that the solar signals in the NH winter extratropics are indeed QBO-phase dependent, moving poleward and downward as winter progresses with a faster descent rate under westerly QBO than under easterly QBO. In the stratosphere, the signals are highly significant in late January to early March and have a life span of 30-50 days. Under westerly QBO, the stratospheric solar signals clearly lead and connect to those in the troposphere in late March and early April where they have a life span of 10 days. As the structure changes considerably from the upper stratosphere to the lower troposphere, the exact month when the maximum solar signals occur depends largely on the altitude chosen. For the low-latitude stratosphere, our analysis supports a vertical double-peaked structure of positive signature of the 11-yr SC in temperature, and demonstrates that this structure is further modulated by the QBO. These solar signals have a longer life span (3-4 months) in comparison to those in the extratropics. The solar signals in the lower stratosphere are stronger in early winter but weaker in late winter, while the reverse holds in the upper stratosphere.
Resumo:
Abstract 1.7.4