944 resultados para high-performance liquid chromatography (HPLC)
Resumo:
Bisphosphonates are drugs that have been widely used in different bone diseases, and have recently been used successfully against many parasites. Various synthetic routes to prepare different types of bisphosphonates have been described, with distinct potency and pharmacological activity. A number of analytical techniques are currently being used to analyze these drugs; among these, the high performance liquid chromatography (HPLC), with different systems of detection, is worth highlighting. However, the development of more sensitive methods is still necessary, once they are essential for bioavailability and bioequivalence studies. This paper reports the major synthesis routes, chemical analysis methodologies and pharmacological applications of bisphosphonates.
Resumo:
This work presents an alternative method for determination of the herbicides tebuthiuron and hexazinone in ground water. The extraction was made with dichloromethane and the analyses by high performance liquid chromatography (HPLC), using reversed-phase column, C-18, mobile phase methanol/water 50:50, v/v, detection and quantification at 247 nm. The following validation parameters were obtained: limit of detection of method 0.02 and 0.03 µg L-1, limit of quantification of method 0.07 and 0.09 µg L-1; linear range limit of quantification of instrument - 300 µg L-1 (r² > 0.998); recoveries from 90.3 to 108.2% and 90.3 to 101.6%; intermediary precision (%RSD) < 8 and < 6%, for hexazinone and tebuthiuron, respectively. The method showed to be efficient and reliable for determination of the herbicides in ground water.
Resumo:
Maltodextrin was produced from cassava and corn starch by enzymatic hydrolysis with alpha-amylase. The cassava starch hydrolysis rate was higher than that of corn starches in maltodextrin production with shorter dextrose equivalent (DE). DE values do not show directly the nature of the obtained oligosaccharides. Maltodextrin produced from cassava and corn starch was analysed by high performance liquid chromatography (HPLC), and the analysis showed that maltodextrin production differs according to the source of the starch. This is important in defining the application of the maltodextrin, according to its desired function.
Resumo:
The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, particularly for the analysis of drugs and metabolites in biological samples, are also discussed.
Resumo:
The analytical method of high performance liquid chromatography (HPLC) for the assay of benznidazole in tablets was developed and validated following the requirements of regulatory agencies. The method used as mobile phase acetonitrile:wather 1:1, a C18 column of 12.5 cm length x 4 mm id, 5 mm particles and lambda=316 nm. The statistical analysis of the results demonstrated that the method satisfies all parameters so as to be considered a safe and efficient analytical alternative of low cost for laboratory routine.
Resumo:
The purpose of this work was to determine the safe shelf life of single-base propellants. The kinetic parameters relative to the consumption of the stabilizer diphenylamine (DPA) added to the propellant were determined as a function of the storage and ageing time. High Performance Liquid Chromatography (HPLC) with spectrophotometric detection was used to determine the DPA percentage before and after the artificial ageing at 60, 70 and 80 ºC. The experimental data were very well adjusted to a pseudo-first order kinetic model and the respective kinetic constants are 8.0-10-3 day-1 (60 ºC); 1.9-10-2 day-1 (70 ºC); 1.2-10-1 day-1 (80 ºC). The activation energy was calculated as 130 kJ mol-1 and the half-time for depletion of the DPA at the hypothetical temperature of 40 ºC of storage was estimated as being 6 years.
Resumo:
A high performance liquid chromatography (HPLC) method has been developed for a rapid determination of nimesulide in dissolution studies. Nimesulide was analyzed using 5 µm Lichrospher® RP-18 column (125 x 4 mm i.d.) and mobile phase acetonitrile: phosphate buffer pH=6.0 (55:45) at a flow-rate of 1.0 mL min-1. Detection was carried out at 300 nm at 25 ºC. The method was applied to analysis of nimesulide in in vitro release studies and showed a rapid and efficient analytical alternative for evaluation of dissolution profile of nimesulide.
Resumo:
Ultra Performance Liquid Chromatography (UPLC) retains the same principles as High Performance Liquid Chromatography (HPLC), but uses 1-2.1 mm i.d. columns with sub-2 µm particles. It is considered the newest advance in analytical separation science. The use of these small particles with mobile phases at high linear velocities increases resolution and detectability and decreases analysis time. Thus, the analyses are faster, the solvent volume is smaller, the efficiency is higher and the detectability is 2-3 times higher when compared with HPLC analysis.
Resumo:
Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC.
Resumo:
Bisphenol A (BPA) is a monomer used in epoxy resin and polycarbonate manufacture. This molecule is considered as an endocrine disruptor that causes different diseases. The human exposition to this non biodegrable substance is increasing in the time; in particular, water is contaminated by industrial remainder flow. In this article heterogeneous photo degradation of a solution of BPA in water solution using a catalytic photo reactor with UV light and titanium dioxide (TiO2) was evaluated. High performance liquid chromatography (HPLC) was used to analyze the photo degradation of BPA solutions. The influence of titanium dioxide amount, BPA concentration, reaction temperature and the catalyst state like suspension and immobilized were also determinated. The highest elimination of BPA was 83.2%, in 240 min, beginning with 0.05 mM of BPA and 100 mg/L of TiO2 in suspension.
Resumo:
This study validated a high performance liquid chromatography (HPLC) method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.
Resumo:
A method using ultrasonication extraction for the determination of 17 polycyclic aromatic hydrocarbons (PAHs), selected by the USEPA and NIOSH as "consent decree" priority pollutants, in soil by High Performance Liquid Chromatography (HPLC) was studied. Separation and detection were completed in 20 min with a C18 columm, acetonitrile-water gradient elution and ultraviolet absorption and fluorescence detections. The detection limits, for a 10 µL of solution injection, were less than 9,917 ng/g in UV detection and less than 1,866 ng/g in fluorescence detection. Several organic solvents were tested for extraction of the 17 PAHs from soils. Acetone was the best solvent among the three solvents tested, and the order of the extraction efficiencies was: acetone>methanol>acetonitrile. Ultrasonication using acetone as solvent extraction was used to evaluate the biodegradation of those compounds in contaminated soil during a vermicomposting process.
Resumo:
The distribution and content of vitamin E isomers was investigated in vegetable oils and raw and cooked egg yolk in commercial restaurants. The analysis of the eight vitamin E isomers was carried out by High Performance Liquid Chromatography (HPLC) with fluorescence detection. The tocopherol and tocotrienol composition of foods varied considerably. Tocopherols were detected in greater quantity and frequency. The α-tocopherol predominated in egg yolks and olive oil while γ-tocopherol was found in high quantities in soybean and canola oils. Cooking did not cause major losses for most of the vitamin E isomers in egg yolks.
Resumo:
The Neem tree, Azadirachta indica, provides many useful compounds that are used as pesticides. However, the efficiency in field of products like neem oil can be committed because they have not been observed reproductive content of secondary metabolic like azadirachtin. Based on reverse-phase high-performance liquid chromatography (HPLC) a new method was developed to permit the rapid quantitative analysis of azadirachtin from seeds, extracts and oil of Neem. In the present study it was evaluated the azadirachtin quantitative variation among various Neem's extracts and seeds showing the importance of quality control for reproduction of the insecticide efficiency, using S. frugiperda as target insect.
Resumo:
This paper reports on a modification of the procedures originally described in the French Pharmacopoeia for the UV-visible spectrometric analysis of flavonoids, and proposes a validation of the method and its application in the determination of total flavonoids from sugarcane (Saccharum officinarum) leaves and vinasse. An analysis of precision and accuracy revealed a low relative standard deviation (< 5.0%) and a good recovery percentages (99.79 and 98.34%). A comparison of the spectrometric results against those obtained by high performance liquid chromatography (HPLC-UV) demonstrated complete compatibility between the modified French Pharmacopoeia (spectrometric) and HPLC-UV methods