935 resultados para anterior segment length
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)
Resumo:
An anterior open occlusal relationship and diastemata may negatively interfere with the harmony of the smile, often requiring a multidisciplinary intervention. This clinical report presents an integrated orthodontic, periodontal, and restorative solution for an anterior open occlusal relationship associated with multiple diastemata and discusses the most relevant aspects related to Its etiology and treatment planning.
Resumo:
Introduction: In this study, we aimed to evaluate the long-term stability of anterior open-bite treatment with occlusal adjustment and the dentinal sensitivity caused by this procedure in the long term. Methods: The sample comprised 17 open-bite patients who experienced relapse of the negative vertical overbite after orthodontic treatment and were retreated with occlusal adjustment. The cephalometric changes were evaluated on lateral cephalograms obtained before and after the occlusal adjustment and in the long term (mean, 3.4 years after occlusal adjustment). Dentinal sensitivity was also evaluated before the occlusal adjustment, and 1.35 months, 4.61 months, and 3.4 years later. The cephalometric statuses between the 3 evaluations were compared with analysis of variance (ANOVA) and Tukey tests. The percentages of clinically significant relapse were calculated. To compare dentinal sensitivity at the several stages, nonparametric Friedman and Wilcoxon tests were performed. Results: Statistically significant relapse of anterior open bite occurred in 33.3% of the patients. Those who had the procedure before 21 years of age were most likely to experience relapse. Dentinal sensitivity remained within the normal range in the long term. Conclusions: Despite the statistically significant relapse of anterior open bite, clinically significant stability was found in 66.7% of the patients. (Am J Orthod Dentofacial Orthop 2010; 138:14.e1-14.e7)
Resumo:
This case report describes the orthodontic treatment of a patient with a deep-overbite Angle Class I malocclusion, agenesis of a mandibular central incisor, and 2 supernumerary teeth, which caused impaction of the mandibular first premolars. The 15-year-old patient also had a convex profile, maxillary dentoalveolar protrusion, and deficiency of space for the correct alignment of teeth. Therefore, treatment consisted of fixed appliance therapy, cervical headgear, extraction of the supernumeraries and the mandibular and maxillary first premolars, and mesiodistal reduction of the maxillary incisors to solve the arch perimeter discrepancy as much as possible with interproximal stripping. This method of treatment significantly improved the patient`s facial and dental esthetics and provided a good functional occlusion, despite the absence of a mandibular incisor, which generally impairs achieving adequate incisal guidance. (Am J Orthod Dentofacial Orthop 2010;138:109-17)
Resumo:
Introduction: The maxillary anterior teeth are the most important to facial esthetics because they are the first to show on a smile. Therefore, stability of the maxillary anterior teeth alignment is an important issue. The objective of this study was to compare the stability of maxillary anterior tooth alignment in Class I and Class II Division 1 malocclusions. Methods: The sample comprised dental casts of 70 patients with Class I and Class II Division 1 malocclusions and a minimum of 3 mm of maxillary anterior crowding measured by an irregularity index. The patients were treated with extractions and evaluated at pretreatment and posttreatment and at least 5 years after treatment. The sample was divided into 3 groups: group 1, Class I malocclusion treated with 4 first premolar extractions comprising 30 subjects, with an initial age of 13.16 years and 8.59 mm of initial maxillary irregularity; group 2, Class II malocclusion treated with 4 first premolar extractions comprising 20 subjects, with an initial age of 12.95 years and 11.10 mm of maxillary irregularity; and group 3, Class II malocclusion treated with 2 first maxillary premolar extractions comprising 20 subjects, with an initial age of 13.09 years and 9.68 mm of maxillary irregularity. Results: The decrease in the maxillary irregularity index was significantly greater in group 2 than in group 1 during treatment. The stability of maxillary anterior alignment was 88.12% over the long term; 77% of the linear displacement of the anatomic contact points tended to return to their original positions. Conclusions: Stability of maxillary anterior alignment between the 3 groups was similar. The stability of maxillary anterior alignment was high over the long term, but a high percentage of teeth tended to return to their original positions. (Am J Orthod Dentofacial Orthop 2011; 139: 768-74)
Resumo:
Introduction: The purpose of this study was to evaluate the cephalometric and occlusal changes, the functional occlusion, and the dentinal sensitivity of anterior open-bite treatment with occlusal adjustment. Methods: The sample comprised 20 patients who experienced relapse of the anterior open bite (mean, -1.06 mm). Occlusal adjustment was performed until a positive overbite was established. Cephalometric changes were evaluated on lateral cephalograms taken before and after the occlusal adjustment. The functional occlusion analysis consisted of evaluating immediate anterior and canine guidance and the number of teeth in contact before and after the procedure. Dentinal sensitivity was evaluated before, shortly after, and 4.61 months after the occlusal adjustment. Pretreatment and posttreatment cephalometric changes and the number of teeth in contact were compared with dependent t tests. Percentages of anterior and canine guidance before and after the adjustment procedure were compared with the McNemar test. To compare dentinal sensitivity at several stages, the nonparametric Friedman test was used, followed by the Wilcoxon test. Results: Significant increases in overbite and mandibular protrusion were seen, as were significant decreases in apical base discrepancy, facial convexity, and growth pattern angles. The percentages of immediate anterior and canine guidance increased significantly, as did the number of teeth with occlusal contacts. Dentinal sensitivity increased immediately after the adjustment but decreased to normal levels after 4.61 months. Conclusions: Occlusal adjustment is a viable treatment alternative for some open-bite patients; it establishes positive vertical overbite and improves the functional occlusion with only transient dentinal sensitivity.
Resumo:
The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.
Resumo:
Objective: The purpose of this study was to evaluate the papilla level adjacent to single-tooth implants in the maxillary anterior region in individuals with cleft lip, alveolus, and palate to verify whether there is correlation among the vertical distance, horizontal distance, dental/prosthetic crown shape, and periodontal/peri-implant biotype with the presence of interproximal papilla. Design: Cross-sectional. Setting: Hospital for Rehabilitation of Craniofacial Anomalies, University of Sao Paulo (HRAC/USP). Patients: 77 papillae in 40 patients. Interventions: The periodontal/peri-implant biotype was clinically evaluated and characterized as thin or thick. Intraoral photographs were used to evaluate the presence or absence of papilla. Main Outcome Measures: Classification in scores (0 to 3) and determination of length (CL) and width (CW) of crowns adjacent to papillae. The CW/CL ratio was calculated for each crown in order to characterize it as square-shaped or triangular-shaped. The vertical and horizontal distances were obtained by radiographic evaluation. Results: The correlations between vertical distance and papilla score and horizontal distance and papilla score were statistically significant (p= .02 and p = .01). There was no significant difference between crown shape and periodontal/peri-implant biotype in distinct correlations with the papilla score (p = .41 and p = .07). Conclusion: The results suggest that the vertical and horizontal distances may have independent or combined relationship with the existence of interproximal papilla; the periodontal/peri-implant biotype (phenotype) was not correlated with the presence or absence of papilla, as well as the shape of the dental/prosthetic crown.
Resumo:
The dorsal surface of the tongue of the bullfrog, Rana catesbeiana, has simple columnar epithelium with a few ciliated cells and goblet cells. The entire surface is covered with numerous filiform papillae and few fungiform. Filiform papillae have a simple columnar epithelium with secretory cells, while the fungiform have a sensory disc on their upper surface the lined by a stratified columnar epithelium with basal, peripheral, glandular and receptor cells. Over the dorsal lingual surface there are numerous winding tubular glands, which penetrate deeply into the muscle of the tongue, mingling with the fibers. The gland epithelium is cylindrical with secretory and supporting cells. The first are absolute on the basis of the gland and the latter are rare in the upper third. The ventral surface of the tongue is lined by a stratified epithelium, with the presence of goblet cells, with ciliated cells among them. Morphometrically, lingual glands varies in length, according to their location: shorter in the anterior region of the tongue (330 mu m) than in the posterior region (450 mu m). Secretory cells of the anterior lingual glands are smaller (1457.7 mm(3)) than the posterior ones (2645.9 mu m(3)). The same can be said of the cell nuclei, 130.0 mu m(3) for the anterior glands and 202.3 mu m(3) for the posterior ones. Secretory cells of the lingual glands contain substances rich in protein and neutral mucopolysaccharides, which characterize the seromucous type. Goblet cells of the dorsal and ventral surface epithelia secrete neutral mucopolysaccharides and proteins, and can be characterized as type G1 cells, and the supporting cells of the superficial glands of the fungiform papillae secrete a mucus rich in neutral mucopolysaccharides, sulfomucins and sialomucins.
Resumo:
The changing incidence of adenocarcinomas, particularly in the oesophagus and gastric cardia, has led to the rapid expansion of screening programmes aimed at detecting the precursor lesion of dysplasia before adenocarcinoma develops. The pathologist now has an important role in first diagnosing patients at risk for developing dysplasia, and then correctly classifying dysplasia when it occurs. Barrett's oesophagus has had different diagnostic criteria in previous years but is currently diagnosed by the presence of intestinal metaplasia of any length in the true oesophagus. Intestinal metaplasia confined only to the gastro-oesophageal junction or cardia is of uncertain significance but is probably common, with less risk of progressing to dysplasia or malignancy. In the stomach, patients with autoimmune atrophic gastritis and Helicobacter-associated multifocal atrophic gastritis have an increased risk of adenocarcinoma, but screening protocols are not well-developed compared with those used for Barrett's oesophagus. Dysplasia of glandular epithelium can be classified using well-described criteria. Low grade dysplasia is the most common type and regresses or remains stable in the majority of patients. High grade dysplasia is more ominous clinically, with a propensity to coexist with or progress to adenocarcinoma.
Resumo:
For all in greater than or equal to 3, the Oberwolfach problem is solved for the case where the 2-factors consist of two cycles of lengths in and m + 1, and for the case where the 2-factors consist of two cycles of lengths m and m + 2.
Resumo:
This study continues the collection of data on the anterior adhesive areas and secretions of monopisthocotylean monogenean (flatworm) parasites and begins an investigation of their phylogenetic usefulness. Here, two species of parasitic worms from an elasmobranch, Troglocephalus rhinobatidis (Monocotylidae: Dasybatotreminae) and Neoheterocotyle rhinobatidis (Monocotylidae: Heterocotylinae), are compared and contrasted. It has been suggested in recent literature that these two taxa are more closely related than is currently recognised. Our data support this view. Both species have multiple apertures on the ventral anterior margin through which adhesive is secreted. Two types of secretion exit from multiple adjacent duct endings terminating in each aperture: rod-shaped (S1) and spherical-shaped (S2) bodies. S1 bodies of both species show nano-banding of similar size and are membrane bound. Ultrastructure of the glands, ducts, duct endings and secreted adhesive is similar for both species, but aperture shape differs. Away from the adhesive areas, tegumental inclusions are found to differ between the two species and another, apparently non-adhesive, secretion is found in N. rhinobatidis.
Resumo:
Sperm ultrastructure in three representative species of the marine bivalve family Spondylidae (spiny or thorny oysters) is examined and compared with available data on other bivalves, especially other families of the subclass Pteriomorphia. Spondylid spermatozoa are of the externally fertilizing aquasperm. type (ect-aquasperm). The acrosomal vesicle is conical with a deep basal invagination extending almost the full length of the vesicle. Vesicle contents are divisible into an inner, highly electron-dense anterior layer and a less dense posterior layer. The anterior layer is folded back on itself posteriorly and exhibits radiating plates (best developed peripherally). The vesicle rests on, and is partially embedded in, an extensive granular deposit of subacrosomal. material at the nuclear apex. This deposit extends partly into acrosomal vesicle invagination and also fills a broad depression in the anterior of the nucleus. No pre-formed axial rod (perforatorium) is present. The nucleus is round-pyriform and its contents coarsely fibrogranular. At the base of the nucleus, four broad depressions partially accommodate the midpiece mitochondria. The midpiece consists the four spherical mitochondria and the proximal and distal centrioles. The centrioles are arranged at approximately 90degrees to each other, and each consists of nine, angularly-oriented, microtubular triplets embedded in a granular matrix. A short, periodically banded rootlet connects the proximal centriole to the nuclear fossa, whereas the distal centriole, which forms the basal body to the flagellar axoneme, is anchored to the plasma membrane by nine terminally forked satellite fibres. Extensive deposits of putative glycogen rosettes surround the centrioles and mitochondria. The flagellum consists of a 9+2 axoneme sheathed by the plasma membrane. Spondylid spermatozoa strongly resemble those of the Pectinidae, further confirming the traditional view (based on comparative anatomy and shell morphology) of a close relationship between the Spondylidae and the Pectinidae. Differences in acrosomal shape and dimensions were noted between the three species examined, indicating potential taxonomic utility for comparative sperm ultrastructure within the Spondylidae.