930 resultados para X-ray computed tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The development of newer diagnostic technologies has reduced the need for invasive electroencephalographic (EEG) studies in identifying the epileptogenic zone, especially in adult patients with mesial temporal lobe epilepsy and hippocampal sclerosis (MTLE-HS). OBJECTIVE: To evaluate ictal single photon emission computed tomography (SPECT) in the evaluation and treatment of patients with MTLE-HS. METHODS: MTLE patients were randomly assigned to those with (SPECT, n = 124) and without ictal SPECT (non-SPECT, n = 116) in an intent-to-treat protocol. Primary end points were the proportion of patients with invasive EEG studies, and those offered surgery. Secondary end points were the length of hospital stay and the proportion of patients with secondarily generalized seizures (SGS) during video-EEG, postsurgical seizure outcome, and hospital cost. RESULTS: The proportion of patients offered surgery was similar in the SPECT (85%) and non-SPECT groups (81%), as well as the proportion that had invasive EEG studies (27% vs 23%). The mean duration of hospital stay was 1 day longer for the SPECT group (P < 0.001). SGS occurred in 51% of the SPECT and 26% of the non-SPECT group (P < 0.001). The cost of the presurgical evaluation was 35% higher for the SPECT compared with the non-SPECT group (P < 0.001). The proportion of patients seizure-free after surgery was similar in the SPECT (59%) compared with non-SPECT group (54%). CONCLUSION: Ictal-SPECT did not add localizing value beyond what was provided by EEG-video telemetry and structural MRI that altered the surgical decision and outcome for MTLE-HS patients. Ictal-SPECT increased hospital stay was associated with increased costs and a higher chance of SGS during video-EEG monitoring. These findings support the notion that a protocol including ictal SPECT is equivalent to one without SPECT in the presurgical evaluation of adult patients with MTLE-HS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The prevention and treatment of diseases related to changes in body composition require accurate methods for the measurement of body composition. However, few studies have dealt specifically with the assessment of body composition of undernourished older subjects by different methodologies. To assess the body composition of undernourished older subjects by two different methods, dual energy x-ray absorptiometry (DXA) and bioelectric impedance (BIA), and to compare results with those of an eutrophic group. The study model was cross-sectional; the study was performed at the University Hospital of the School of Medicine of Ribeiro Preto, University of So Paulo, Brazil. Forty-one male volunteers aged 62 to 91 years. The groups were selected on the basis of anamnesis, physical examination and nutritional assessment according to the Mini Nutritional Assessment (MNA) score. Body composition was assessed by DXA and BIA. Body weight, arm and calf circumference, body mass index (BMI), fat free mass (FFM) and fat mass (FM) were significantly lower in the undernourished group as compared to the eutrophic group. There were no significant differences between FFM and FM mean values determined by DXA and BIA in both groups, but the agreement between methods in the undernourished group was less strong. Our results suggest caution when BIA is to be applied in studies including undernourished older subjects. This study does not support BIA as an accurate method for the individual assessment of body composition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Human immunodeficiency virus (HIV)associated lipodystrophy syndrome (LS) includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. Objective: The aim of the study was to compare different methods to evaluate body composition between Brazilians HIV subjects with (HIV+LIPO+) or without LS (HIV+LIPO-) and healthy subjects (Control). Methods: in a cross-sectional analyses, body composition was measured by bioelectrical impedance analysis (BIA), skinfold thickness (SF) and dual-energy x-ray absorptiometry (DXA) in 10 subjects from HIV+LIPO+ group; 22 subjects from HIV+LIPO- group and 12 from Control group. Results: There were no differences in age and body mass index (BMI) between groups. The fat mass (FM) (%) estimated by SF did not correlate with DXA in HIV+LIPO+ group (r = 0,46/p >0,05) and had fair agreement in both HIV groups (HIV+LIPO+ =0,35/ HIV+ LIPO- = 0,40). BIA had significant correlation in all groups (p < 0,05) and strong agreement, meanly in HIV groups, for FM (HIV+LIPO+ = 0,79/ HIV+LIPO- = 0,85/Control = 0,60) and for fat free mass (FFM) (HIV+LIPO+ = 0,93/ HIV+LIPO- = 0,92 / Control = 0,73). Discussion: Total fat mass can be measured by BIA with good precision, but not by SF in HIV-infected patients with LS. Segmental BIA, triciptal SF, circumferences of arms, waist and legs maybe alternatives that need more studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For some surgical procedures in veterinary dentistry including exodontia, orthognathic surgery, orthopedic surgery, oncologic surgery, and for the placement of dental implants, it is important to know the accurate location of the neurovascular structures within the mandibular canal. The aim of this research was to determine the course of the mandibular canal in the mandible and its relationship with other anatomical structures in brachycephalic dogs using computerized tomography. Mandibles from 10 brachycephalic cadaver dogs were evaluated. Measurements were taken in relation to the lingual, vestibular alveolar crest, and ventral surfaces. These measurements indicated that the mandibular canal descends slightly from the mandibular foramen to the molar area, decreasing the distance of the mandibular canal from the mandibular ventral border The mandibular canal is slightly closer to the lingual surface than the vestibular surface except in the molar tooth region. The mandibular canal continues in a rostral direction occupying the ventral region of the mandibular body, reaching its maximum distance from the alveolar crest at the level of the first molar and fourth premolar teeth. In the third and fourth premolar tooth region, the mandibular canal maintains a similar distance between the vestibular and lingual borders; then, at the level of the second premolar tooth, the distance of the mandibular canal from the lingual and ventral border increases before its termination at the mental, foramen. The study reported here documents the feasibility of using CT to determine the location of the mandibular canal in relation to bony and dental parameters. Although the difference in mandible size of the group of brachycephalic dogs reported here resulted in broad ranges of measurements, it is clear that the MC course may vary between individual dogs. J Vet Dent 26(3); 156 - 163, 2009

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row computed tomographic coronary angiography (CTCA). We studied five HoFH patients (three females, two males, mean age 19.8 +/- 2.9 years, age range 15-23 years, with a mean low density lipoprotein (LDL) cholesterol 618 +/- 211 mg/dL) using 64 slice CTCA. None of the patients showed evidence of ischemia with standard exercise testing. Calcified and mixed atherosclerotic plaques adjacent to or compromising the coronary artery ostia were found in all study subjects. Coronary plaques causing significant obstruction were found in one patient, who had previously undergone coronary artery bypass surgery and aortic valve replacement. Two other patients were noted to have non-obstructive calcified, mixed and non-calcified coronary artery plaques. Our data suggest that CTCA could be a useful non-invasive method for detection of early aortic and coronary atherosclerosis specifically affecting the coronary ostia in HoFH subjects. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of the present study was to test the accuracy of small-volume cone-beam computed tomography (CBCT) scanning in the detection of horizontal root fractures and to assess the influence of a metallic post. Methods: Forty teeth were divided into four groups based on the presence of metallic posts and horizontal root fracture. The teeth were examined by small-volume CBCT scanning at 0.2-mm voxel resolution. Three observers analyzed the samples for the presence of a horizontal root fracture. Sensitivity and specificity were calculated. Results: High values for accuracy (73%-88%) were obtained in the groups without a metallic post, and statistically significant differences were found when the group with a metallic post has been observed (55%-70%). Intraobserver agreement also showed statistically significant differences in the groups with a metallic post. Conclusions: Small-volume CBCT scanning showed high accuracy in detecting horizontal root fracture without a metallic post. However, the presence of a metallic post significantly reduced the specificity and sensitivity of this examination. (J Endod 2011;37:1456-1459)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The calcifying cystic odontogenic tumour (CCOT) is a rare benign cystic neoplasm not infrequently associated with odontoma. This report documents a case of CCOT associated with compound odontoma arising in the anterior maxilla in a 25-year-old woman. Conventional radiographs showed a large calcified mass with poorly visualized radiolucent margins. The extent and condition of the internal structure of the CCOT associated with odontoma was able to be determined based on radiographic findings from cone beam computed tomography. This advanced image technique proved to be extremely useful in the radiographic assessment of this particular neoplasm of the jawbones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim was to verify the concordance of CT evaluation among four radiologists (two oral and maxillofacial and two medical radiologists) at the TN (tumour/node) stage and in the follow-up of oral cavity and oropharyngeal cancer patients. The study also compared differences between clinical and CT examinations in determining the TN stage. Methods: The following clinical and tomographic findings of 15 non-treated oral cavity and oropharyngeal cancer patients were compared: tumour size, bone invasion and lymph node metastases. In another 15 patients, who had previously been treated, a clinical and tomographic analysis comparison for the presence of tumoural recurrence, post-therapeutic changes in muscles and lymph node metastases was performed. The concordances of tomographic evaluation between the radiologists were analysed using the kappa index. Results: Significant agreement was verified between all radiologists for the T stage, but not for the N stage. In the group of treated patients, CT disclosed post-therapeutic changes in muscles, tumour recurrence and lymph node metastases, but no concordance for the detection of lymph node metastases was found between radiologists. In the first group, for all radiologists, no concordance was demonstrated between clinical and tomographic staging. CT was effective for delimitating advanced lesions and for detecting lymph node involvement in N0 stage patients. CT revealed two cases of bone invasion not clinically detected. Conclusions: Interprofessional relationships must be stimulated to improve diagnoses, and to promote a multidisciplinary approach to oral cavity and oropharyngeal cancer. Although CT was important in the diagnosis and follow-up of cancer patients, differences between medical and dental analyses should be acknowledged. Dentomaxillofacial Radiology (2010) 39, 140-148. doi: 10.1259/dmfr/69910245

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the area and volume of bone available for grafting in a donor retromolar region using computed tomography (CT). Materials and Methods: Ten patients previously scanned by multislice CT were selected for evaluation. Images from partially and completely dentate patients at least 18 years of age were included in the study; those from patients with impacted or erupted third molars or intrabony lesions in the study area were not included. Computer software with appropriate tools was used to handle the images. Two calibrated observers made measurements separately. Safety margins in relation to the lingual cortex, the base of mandible, and the alveolar canal were established in each cross-section of the CTs. Measurements were done by using cross-sectional views, and the results were calculated after three-dimensional reconstruction, providing area and volume data. Results: The mean area of bone available for grafting was 8.12 cm(2) ( range, 0.00 to 13.60 cm(2)) and 8.32 cm(2) ( range, 0.00 to 14.30 cm(2)) for observers 1 and 2, respectively. Mean available bone volume for grafting was 0.79 cm(3) ( range, 0.00 to 1.50 cm(3)) for observer 1 and 0.85 cm(3) ( range, 0.00 to 1.60 cm(3)) for observer 2. Interobserver analysis showed substantial agreement. Conclusion: The retromolar region showed a wide variety of anatomic differences among patients. Three-dimensional multislice CT allows reproducible measurements of the area and volume of the retromolar region. Int J Oral Maxillofac Implants 2010; 25: 374-378

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tumoural and cystic lesions are common findings in the daily practice of dental professionals and maxillofacial radiologists. However, simultaneous lesions are rare and represent a diagnostic challenge to overcome. Among tumoural pathologies, odontomas are the most common odontogenic tumour of the jaws. Cystic transformation or development from the tumoural capsule are well recognized in situations such as ameloblastomas originated from a dentigerous cyst. Otherwise, despite literature reports, dentigerous cysts arising from odontomas are very rare and could lead to misdiagnosis. Here, we report a case of a complex odontoma associated with a dentigerous cyst in the maxillary sinus, focussing on the tomographic features and a differential imaging approach to the diagnosis of these lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osny Ferreira-Junior, Luciana Dorigatti de Avila, Marcelo Bonifacio da Silva Sampieri, Eduardo Dias-Ribeiro, Weiliang Chen, Song Fan. Impacted Lower Third Molar Fused with a Supernumerary Tooth-Diagnosis and Treatment Planning Using Cone-Beam Computed Tomography. International Journal of Oral Science, 1(4): 224-228, 2009 This paper reported a case of fusion between an impacted third molar and a supernumerary tooth, in which a surgical intervention was carried out, with the objective of removing the dental elements. The panoramic radiography was complemented by the Donovan`s radiographic technique; but because of the proximity of the dental element to the mandibular ramus, it was not possible to have a final fusion diagnosis. Hence, the Cone-Beam Computed Tomography-which provides precise three-dimensional information-was used to determinate the fusion diagnosis and also to help in the surgical planning. In this case report we observed that the periapical, occlusal and panoramic were not able to show details which could only be examined through the cone-beam computed tomography.