969 resultados para SOLUTION PHASE EQUILIBRIA
Resumo:
A simple and fast approach for solid phase extraction is herein described, and used to determine trace amounts of Pb2+ and Cu2+ metal ions. The solid phase support is sodium dodecyl sulfate (SDS)-coated γ-alumina modified with bis(2-hydroxy acetophenone)-1,6-hexanediimine (BHAH) ligand. The adsorbed ions were stripped from the solid phase by 6 mL of 4 M nitric acid as eluent. The eluting solution was analyzed by flame atomic absorption spectrometry (FAAS). The sorption recovery of metal ions was investigated with regard to the effects of pH, amount of ligand, γ-alumina and surfactant and the amount and type of eluent. Complexation of BHAH with Pb2+ or Cu2+ ions was examined via spectrophotometry using the HypSpec program. The detection limit for Cu2+ was 7.9 µg L-1 with a relative standard deviation of 1.67%, while that for Pb2+ was 6.4 µg L-1 with a relative standard deviation of 1.64%. A preconcentration factor of 100 was achieved for these ions. The method was successfully applied to determine analyte concentrations in samples of liver, parsley, cabbage, and water.
Resumo:
In the present work, a simple and rapid ligand-less, in situ, surfactant-based solid phase extraction for the preconcentration of copper in water samples was developed. In this method, a cationic surfactant (n-dodecyltrimethylammonium bromide) was dissolved in an aqueous sample followed by the addition of an appropriate ion-pairing agent (ClO4-). Due to the interaction between the surfactant and ion-pairing agent, solid particles were formed and subsequently used for the adsorption of Cu(OH)2 and CuI. After centrifugation, the sediment was dissolved in 1.0 mL of 1 mol L-1 HNO3 in ethanol and aspirated directly into the flame atomic absorption spectrometer. In order to obtain the optimum conditions, several parameters affecting the performance of the LL-ISS-SPE, including the volumes of DTAB, KClO4, and KI, pH, and potentially interfering ions, were optimized. It was found that KI and phosphate buffer solution (pH = 9) could extract more than 95% of copper ions. The amount of copper ions in the water samples varied from 3.2 to 4.8 ng mL-1, with relative standard deviations of 98.5%-103%. The determination of copper in water samples was linear over a concentration range of 0.5-200.0 ng mL-1. The limit of detection (3Sb/m) was 0.1 ng mL-1 with an enrichment factor of 38.7. The accuracy of the developed method was verified by the determination of copper in two certified reference materials, producing satisfactory results.
Resumo:
A flow injection spectrophotometric procedure with on-line solid-phase reactor containing ion triiodide immobilized in an anion-exchange resin is proposed for the determination of adrenaline (epinephrine) in pharmaceutical products. Adrenaline is oxidized by triiodide ion immobilized in an anionic-exchange resin yielding adrenochrome which is transported by the carrier solution and detected at a wavelength of 488 nm. Adrenaline was determined in three pharmaceutical products in the 6.4 x 10-6 to 3.0 x 10-4 mol L-1 concentration range with a detection limit of 4.8 x 10-7 mol L-1. The recovery of this analyte in three samples ranged from 96.0 to 105 %. The analytical frequency was 80 determinations per hour and the RSDs were less than 1 % for adrenaline concentrations of 6.4 x 10-5 and 2.0 x 10-4 mol L-1 (n=10). A paired t-test showed that all results obtained for adrenaline in commercial formulations using the proposed flow injection procedure and a spectrophotometric batch procedure agree at the 95% confidence level.
Resumo:
The maximum realizable power throughput of power electronic converters may be limited or constrained by technical or economical considerations. One solution to this problemis to connect several power converter units in parallel. The parallel connection can be used to increase the current carrying capacity of the overall system beyond the ratings of individual power converter units. Thus, it is possible to use several lower-power converter units, produced in large quantities, as building blocks to construct high-power converters in a modular manner. High-power converters realized by using parallel connection are needed for example in multimegawatt wind power generation systems. Parallel connection of power converter units is also required in emerging applications such as photovoltaic and fuel cell power conversion. The parallel operation of power converter units is not, however, problem free. This is because parallel-operating units are subject to overcurrent stresses, which are caused by unequal load current sharing or currents that flow between the units. Commonly, the term ’circulatingcurrent’ is used to describe both the unequal load current sharing and the currents flowing between the units. Circulating currents, again, are caused by component tolerances and asynchronous operation of the parallel units. Parallel-operating units are also subject to stresses caused by unequal thermal stress distribution. Both of these problemscan, nevertheless, be handled with a proper circulating current control. To design an effective circulating current control system, we need information about circulating current dynamics. The dynamics of the circulating currents can be investigated by developing appropriate mathematical models. In this dissertation, circulating current models aredeveloped for two different types of parallel two-level three-phase inverter configurations. Themodels, which are developed for an arbitrary number of parallel units, provide a framework for analyzing circulating current generation mechanisms and developing circulating current control systems. In addition to developing circulating current models, modulation of parallel inverters is considered. It is illustrated that depending on the parallel inverter configuration and the modulation method applied, common-mode circulating currents may be excited as a consequence of the differential-mode circulating current control. To prevent the common-mode circulating currents that are caused by the modulation, a dual modulator method is introduced. The dual modulator basically consists of two independently operating modulators, the outputs of which eventually constitute the switching commands of the inverter. The two independently operating modulators are referred to as primary and secondary modulators. In its intended usage, the same voltage vector is fed to the primary modulators of each parallel unit, and the inputs of the secondary modulators are obtained from the circulating current controllers. To ensure that voltage commands obtained from the circulating current controllers are realizable, it must be guaranteed that the inverter is not driven into saturation by the primary modulator. The inverter saturation can be prevented by limiting the inputs of the primary and secondary modulators. Because of this, also a limitation algorithm is proposed. The operation of both the proposed dual modulator and the limitation algorithm is verified experimentally.
Resumo:
In this work is proposed a solid phase preconcentration system of Co2+ ions and its posterior determination by GFAAS in which fractional factorial design and response surface methodology (RSM) were used for optimization of the variables associated with preconcentration system performance. The method is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam (PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and its determination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluent concentration and preconcentration and elution flow rates. Results obtained from fractional factorial design 2(5-1) showed that only the variables pH, buffer concentration and interaction (pH X buffer concentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidence level. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit of detection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10 µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and 2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations.
Resumo:
A procedure for separation and preconcentration of trace amounts of Zn(II) from aqueous media is proposed. The procedure is based on the adsorption of Zn2+ on octadecyl bonded silica membrane disk modified with N,N'-disalicylidene-1,2-phenylendiamine at pH 7. The retained zinc ions were then stripped from the disk with a minimal amount of 1.5 mol L-1 hydrochloric acid solution as eluent, and determined by flame atomic absorption spectrometry. Maximum capacity of the membrane disk modified with 5 mg of the ligand was found to be 226 µg Zn2+. The relative standard deviation of zinc for ten replicate extraction of 10 µg zinc from 1000 mL samples was 1.2%. The limit of detection of the proposed method was 14 ng of Zn2+ per 1000 mL. The method was successfully applied to the determination of zinc in natural water samples and accuracy was examined by recovery experiments and independent analysis by graphite furnace atomic absorption spectrometry (GFAAS).
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.
Resumo:
The combination of two low-cost classical procedures based on titrimetric techniques is presented for the determination of pyridoxine hydrochloride in pharmaceuticals samples. Initially some experiments were carried out aiming to determine both pKa1 and pKa2 values, being those compared to values of literature and theoretical procedures. Commercial samples containing pyridoxine hydrochloride were electrochemically analysed by exploiting their acid-base and precipitation reactions. Potentiometric titrations accomplished the reaction between the ionizable hydrogens present in pyridoxine hydrochloride, being NaOH used as titrant; while the conductimetric method was based on the chemical precipitation between the chloride of pyridoxine hydrochloride molecule and Ag+ ions from de silver nitrate, changing the conductivity of the solution. Both methods were applied to the same commercial samples leading to concordant results when compared by statistical tests (95 and 98% confidence levels). Recoveries ranging from 99.0 to 108.1% were observed, showing no significant interference on the results.
Resumo:
PURPOSE: To evaluate the effectiveness and the safety of orally administered misoprostol in comparison to intravenously infused oxytocin for labor induction in term pregnant women. METHODS: Between 2008 and 2010, a total of 285 term pregnant women whom were candidate for vaginal delivery were assessed for eligibility to enter the study. Twenty five patients were excluded for different reasons; and 260 included women were randomly assigned to one of the two groups according to the method of treatment, misoprostol or oxytocin. The misoprostol group received 25 µg every 2 hours for up to 24 hours for induction. The oxytocin group received an infusion of 10 IU which was gradually increased. The time from induction to delivery and induction to the beginning of the active phase and successful inductions within 12, 18, and 24 hours were recorded. The trial is registered at irct.ir, number IRCT2012061910068N1. RESULTS: Failure of induction, leading to caesarean section was around 38.3% in the oxytocin group and significantly higher than that of the misoprostol group (20.3%) (p<0.001). Despite the more prevalent failure in the oxytocin group, the mean time intervals from induction to active phase and labor of this group were both significantly less than the misoprostol group (10.1±6.1 and 13.2±7.7 versus 12.9±5.4 and 15.6±5.1 hours respectively, both p-values were <0.05). Maternal and fetal complications were comparable between groups except gastrointestinal symptoms which were encountered more frequently in the misoprostol (10.9 versus 3.9%, p=0.03). CONCLUSIONS: Misoprostol is a safe and effective drug with low complications for the induction of labor. Failure is seen less with misoprostol and caesarean sections are less frequently indicated as compared to oxytocin.
Resumo:
The formal calibration procedure of a phase fraction meter is based on registering the outputs resulting from imposed phase fractions at known flow regimes. This can be straightforwardly done in laboratory conditions, but is rarely the case in industrial conditions, and particularly for on-site applications. Thus, there is a clear need for less restrictive calibration methods regarding to the prior knowledge of the complete set of inlet conditions. A new procedure is proposed in this work for the on-site construction of the calibration curve from total flown mass values of the homogeneous dispersed phase. The solution is obtained by minimizing a convenient error functional, assembled with data from redundant tests to handle the intrinsic ill-conditioned nature of the problem. Numerical simulations performed for increasing error levels demonstrate that acceptable calibration curves can be reconstructed, even from total mass measured within a precision of up to 2%. Consequently, the method can readily be applied, especially in on-site calibration problems in which classical procedures fail due to the impossibility of having a strict control of all the input/output parameters.
Resumo:
Lignocellulosic biomasses (e.g., wood and straws) are a potential renewable source for the production of a wide variety of chemicals that could be used to replace those currently produced by petrochemical industry. This would lead to lower greenhouse gas emissions and waste amounts, and to economical savings. There are many possible pathways available for the manufacturing of chemicals from lignocellulosic biomasses. One option is to hydrolyze the cellulose and hemicelluloses of these biomasses into monosaccharides using concentrated sulfuric acid as catalyst. This process is an efficient method for producing monosaccharides which are valuable platforn chemicals. Also other valuable products are formed in the hydrolysis. Unfortunately, the concentrated acid hydrolysis has been deemed unfeasible mainly due to high chemical consumption resulting from the need to remove sulfuric acid from the obtained hydrolysates prior to the downstream processing of the monosaccharides. Traditionally, this has been done by neutralization with lime. This, however, results in high chemical consumption. In addition, the by-products formed in the hydrolysis are not removed and may, thus, hinder the monosaccharide processing. In order to improve the feasibility of the concentrated acid hydrolysis, the chemical consumption should be decreased by recycling of sulfuric acid without neutralization. Furthermore, the monosaccharides and the other products formed in the hydrolysis should be recovered selectively for efficient downstream processing. The selective recovery of the hydrolysis by-products would have additional economical benefits on the process due to their high value. In this work, the use of chromatographic fractionation for the recycling of sulfuric acid and the selective recovery of the main components from the hydrolysates formed in the concentrated acid hydrolysis was investigated. Chromatographic fractionation based on the electrolyte exclusion with gel type strong acid cation exchange resins in acid (H+) form as a stationary phase was studied. A systematic experimental and model-based study regarding the separation task at hand was conducted. The phenomena affecting the separation were determined and their effects elucidated. Mathematical models that take accurately into account these phenomena were derived and used in the simulation of the fractionation process. The main components of the concentrated acid hydrolysates (sulfuric acid, monosaccharides, and acetic acid) were included into this model. Performance of the fractionation process was investigated experimentally and by simulations. Use of different process options was also studied. Sulfuric acid was found to have a significant co-operative effect on the sorption of the other components. This brings about interesting and beneficial effects in the column operations. It is especially beneficial for the separation of sulfuric acid and the monosaccharides. Two different approaches for the modelling of the sorption equilibria were investigated in this work: a simple empirical approach and a thermodynamically consistent approach (the Adsorbed Solution theory). Accurate modelling of the phenomena observed in this work was found to be possible using the simple empirical models. The use of the Adsorbed Solution theory is complicated by the nature of the theory and the complexity of the studied system. In addition to the sorption models, a dynamic column model that takes into account the volume changes of the gel type resins as changing resin bed porosity was also derived. Using the chromatography, all the main components of the hydrolysates can be recovered selectively, and the sulfuric acid consumption of the hydrolysis process can be lowered considerably. Investigation of the performance of the chromatographic fractionation showed that the highest separation efficiency in this separation task is obtained with a gel type resin with a high crosslinking degree (8 wt. %); especially when the hydrolysates contain high amounts of acetic acid. In addition, the concentrated acid hydrolysis should be done with as low sulfuric acid concentration as possible to obtain good separation performance. The column loading and flow rate also have large effects on the performance. In this work, it was demonstrated that when recycling of the fractions obtained in the chromatographic fractionation are recycled to preceding unit operations these unit operations should included in the performance evaluation of the fractionation. When this was done, the separation performance and the feasibility of the concentrated acid hydrolysis process were found to improve considerably. Use of multi-column chromatographic fractionation processes, the Japan Organo process and the Multi-Column Recycling Chromatography process, was also investigated. In the studied case, neither of these processes could compete with the single-column batch process in the productivity. However, due to internal recycling steps, the Multi-Column Recycling Chromatography was found to be superior to the batch process when the product yield and the eluent consumption were taken into account.
Resumo:
The objective of this research is to observe the state of customer value management in Outotec Oyj, determine the key development areas and develop a phase model with which to guide the development of a customer value based sales tool. The study was conducted with a constructive research approach with the focus of identifying a problem and developing a solution for the problem. As a basis for the study, the current literature involving customer value assessment and solution and customer value selling was studied. The data was collected by conducting 16 interviews in two rounds within the company and it was analyzed by coding openly. First, seven important development areas were identified, out of which the most critical were “Customer value mindset inside the company” and “Coordination of customer value management activities”. Utilizing these seven areas three functionality requirements, “Preparation”, “Outotec’s value creation and communication” and “Documentation” and three development requirements for a customer value sales tool were identified. The study concluded with the formulation of a phase model for building a customer value based sales tool. The model included five steps that were defined as 1) Enable customer value utilization, 2) Connect with the customer, 3) Create customer value, 4) Define tool to facilitate value selling and 5) Develop sales tool. Further practical activities were also recommended as a guide for executing the phase model.
Resumo:
La présente étude porte sur l’évaluation d’une méthode d’acquisition de la solution de sol présente à l’interface sol-racine, dans la rhizosphère. Cette interface constitue le lieu privilégié de prise en charge par les plantes des contaminants, tels que les métaux traces. Comme les plantes acquièrent ces éléments à partir de la phase liquide, la solution de sol de la rhizosphère est une composante clé pour déterminer la fraction de métaux traces biodisponibles. La microlysimétrie est la méthode in situ la plus appropriée pour aborder les difficultés liées à l’échelle microscopique de la rhizosphère. Ainsi, dans les études sur la biodisponibilité des métaux traces au niveau de la rhizosphère, les microlysimètres (Rhizon©) gagnent en popularité sans, toutefois, avoir fait l’objet d’études exhaustives. L’objectif de cette étude est donc d’évaluer la capacité de ces microlysimètres à préserver l’intégrité chimique de la solution, tout en optimisant leur utilisation. Pour ce faire, les microlysimètres ont été soumis à une série d’expériences en présence de solutions et de sols, où la quantité de solution prélevée et le comportement des métaux traces (Cd, Cu, Ni, Pb, Zn) ont été étudiés. Les résultats montrent que les microlysimètres fonctionnent de façon optimale lorsque le contenu en eau du sol est au-dessus de la capacité au champ et lorsqu’il y a peu de matière organique et d’argile. Les sols sableux ayant un faible contenu en C organique reproduisent mieux le volume prélevé et la solution sous la capacité au champ peut être récoltée. L’utilisation des microlysimètres dans ces sols est donc optimale. Dans les essais en solution, les microlysimètres ont atteint un équilibre avec la solution après 10 h de prélèvement. En respectant ce délai et les conditions optimales préalablement établies (pH acide et COD élevé), les microlysimètres préservent la composition chimique de la solution. Dans les essais en sol, cet équilibre n’a pas été atteint après dix jours et huit prélèvements. Le contenu en matière organique et l’activité microbienne semblent responsables de la modification des concentrations en métaux au cours de ces prélèvements, notamment, dans l’horizon FH où les microlysimètres performent très mal. En revanche, dans l’horizon B, les concentrations tendent à se stabiliser vers la fin de la série de prélèvements en se rapprochant des valeurs de référence. Bien que des valeurs plus élevées s’observent pour les microlysimètres, leurs concentrations en métaux sont comparables à celles des méthodes de référence (extrait à l’eau, lysimètres de terrain avec et sans tension). En somme, les microlysimètres se comportent généralement mieux dans l’horizon B. Même si leur utilisation est plus optimale dans un sol sableux, cet horizon est privilégié pour de futures études sur le terrain avec les microlysimètres.
Resumo:
Les sels d’imidazolium ont un rôle important dans certaines protéines et acides nucléiques et ont été utilisés à de nombreuses reprises dans des assemblages supramoléculaires en raison de leurs propriétés uniques. Les sels de diimidazolium dérivés sont toutefois moins connus. Ils ont pour l’instant uniquement été utilisés comme des précurseurs de carbènes N-hétérocycliques. Ils sont donc à la base de plusieurs catalyseurs utilisés pour des réactions de couplage croisés mais leurs propriétés sont toutefois méconnues dans le cadre de la chimie supramoléculaire. Cette classe de composés a nottament attiré notre attention en raison de la facilité de modification de leurs propriétés physico-chimiques par modification de leur structure chimique. L’objectif général des travaux présentés dans cette thèse est l’étude des propriétés supramoléculaires des sels de diimidazolium disubstitués en solution (aqueuse ou organique), ainsi qu’en phase solide ou cristal-liquide. L’influence de l’espaceur entre les deux noyaux imidazolium ainsi que l’influence des substituants latéraux et des contre-ions a été étudiée. Dans un premier temps, les propriétés de complexation des sels de diimidazolium à des macrocycles sont étudiées. Les sels bromure sont étudiés en solution aqueuse avec plusieurs cyclodextrines et le cucurbit[7]uril, et les sels hexafluorophosphate sont étudiés en solution organique pour leur complexation avec l’éther couronne DB24C8 et un calix[4]arène. Cette nouvelle classe de composés a montré de très bonnes propriétés de complexation à ces différents macrocycles en solution et a également permis de contrôler différents assemblages supramoléculaires à l’interface air-eau. Dans un deuxième temps, l’étude des sels de phénylènediimidazolium a permis de modifier les propriétés de complexation en solution pour obtenir la formation de complexes multiples avec le cucurbit[7]util en solution aqueuse. Cette même famille de composés a également permis la formation de cristaux liquides ioniques lorsque les substituants sont des chaînes alkyles plus longues. La résolution de plusieurs structures cristallines de différents sels de diimidazolium a finalement permis de comprendre la nature des interactions intermoléculaires à l’état cristallin. La recherche présentée dans cette thèse a donc permis une étude détaillée des propriétés supramoléculaires des sels de diimidazolium dans tous les états de la matière qui leur sont accessibles.
Resumo:
La gestion des ressources, équipements, équipes de travail, et autres, devrait être prise en compte lors de la conception de tout plan réalisable pour le problème de conception de réseaux de services. Cependant, les travaux de recherche portant sur la gestion des ressources et la conception de réseaux de services restent limités. La présente thèse a pour objectif de combler cette lacune en faisant l’examen de problèmes de conception de réseaux de services prenant en compte la gestion des ressources. Pour ce faire, cette thèse se décline en trois études portant sur la conception de réseaux. La première étude considère le problème de capacitated multi-commodity fixed cost network design with design-balance constraints(DBCMND). La structure multi-produits avec capacité sur les arcs du DBCMND, de même que ses contraintes design-balance, font qu’il apparaît comme sous-problème dans de nombreux problèmes reliés à la conception de réseaux de services, d’où l’intérêt d’étudier le DBCMND dans le contexte de cette thèse. Nous proposons une nouvelle approche pour résoudre ce problème combinant la recherche tabou, la recomposition de chemin, et une procédure d’intensification de la recherche dans une région particulière de l’espace de solutions. Dans un premier temps la recherche tabou identifie de bonnes solutions réalisables. Ensuite la recomposition de chemin est utilisée pour augmenter le nombre de solutions réalisables. Les solutions trouvées par ces deux méta-heuristiques permettent d’identifier un sous-ensemble d’arcs qui ont de bonnes chances d’avoir un statut ouvert ou fermé dans une solution optimale. Le statut de ces arcs est alors fixé selon la valeur qui prédomine dans les solutions trouvées préalablement. Enfin, nous utilisons la puissance d’un solveur de programmation mixte en nombres entiers pour intensifier la recherche sur le problème restreint par le statut fixé ouvert/fermé de certains arcs. Les tests montrent que cette approche est capable de trouver de bonnes solutions aux problèmes de grandes tailles dans des temps raisonnables. Cette recherche est publiée dans la revue scientifique Journal of heuristics. La deuxième étude introduit la gestion des ressources au niveau de la conception de réseaux de services en prenant en compte explicitement le nombre fini de véhicules utilisés à chaque terminal pour le transport de produits. Une approche de solution faisant appel au slope-scaling, la génération de colonnes et des heuristiques basées sur une formulation en cycles est ainsi proposée. La génération de colonnes résout une relaxation linéaire du problème de conception de réseaux, générant des colonnes qui sont ensuite utilisées par le slope-scaling. Le slope-scaling résout une approximation linéaire du problème de conception de réseaux, d’où l’utilisation d’une heuristique pour convertir les solutions obtenues par le slope-scaling en solutions réalisables pour le problème original. L’algorithme se termine avec une procédure de perturbation qui améliore les solutions réalisables. Les tests montrent que l’algorithme proposé est capable de trouver de bonnes solutions au problème de conception de réseaux de services avec un nombre fixe des ressources à chaque terminal. Les résultats de cette recherche seront publiés dans la revue scientifique Transportation Science. La troisième étude élargie nos considérations sur la gestion des ressources en prenant en compte l’achat ou la location de nouvelles ressources de même que le repositionnement de ressources existantes. Nous faisons les hypothèses suivantes: une unité de ressource est nécessaire pour faire fonctionner un service, chaque ressource doit retourner à son terminal d’origine, il existe un nombre fixe de ressources à chaque terminal, et la longueur du circuit des ressources est limitée. Nous considérons les alternatives suivantes dans la gestion des ressources: 1) repositionnement de ressources entre les terminaux pour tenir compte des changements de la demande, 2) achat et/ou location de nouvelles ressources et leur distribution à différents terminaux, 3) externalisation de certains services. Nous présentons une formulation intégrée combinant les décisions reliées à la gestion des ressources avec les décisions reliées à la conception des réseaux de services. Nous présentons également une méthode de résolution matheuristique combinant le slope-scaling et la génération de colonnes. Nous discutons des performances de cette méthode de résolution, et nous faisons une analyse de l’impact de différentes décisions de gestion des ressources dans le contexte de la conception de réseaux de services. Cette étude sera présentée au XII International Symposium On Locational Decision, en conjonction avec XXI Meeting of EURO Working Group on Locational Analysis, Naples/Capri (Italy), 2014. En résumé, trois études différentes sont considérées dans la présente thèse. La première porte sur une nouvelle méthode de solution pour le "capacitated multi-commodity fixed cost network design with design-balance constraints". Nous y proposons une matheuristique comprenant la recherche tabou, la recomposition de chemin, et l’optimisation exacte. Dans la deuxième étude, nous présentons un nouveau modèle de conception de réseaux de services prenant en compte un nombre fini de ressources à chaque terminal. Nous y proposons une matheuristique avancée basée sur la formulation en cycles comprenant le slope-scaling, la génération de colonnes, des heuristiques et l’optimisation exacte. Enfin, nous étudions l’allocation des ressources dans la conception de réseaux de services en introduisant des formulations qui modèlent le repositionnement, l’acquisition et la location de ressources, et l’externalisation de certains services. À cet égard, un cadre de solution slope-scaling développé à partir d’une formulation en cycles est proposé. Ce dernier comporte la génération de colonnes et une heuristique. Les méthodes proposées dans ces trois études ont montré leur capacité à trouver de bonnes solutions.