909 resultados para SHORT-CONTACT TIMES


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the study was to use scanning electron microscopy and energy dispersive x-ray spectrometry to assess possible morphologic and chemical changes after performing double-insertion and pullout tests of implants of different shapes and surface treatments. Four different types of implants were used—cylindrical machined-surface implants, cylindrical double-surface–treated porous implants, cylindrical surface-treated porous implants, and tapered surface-treated porous implants—representing a total of 32 screws. The implants were inserted into synthetic bone femurs, totaling 8 samples, before performing each insertion with standardized torque. After each pullout the implants were analyzed by scanning electron microscopy and energy dispersive x-ray spectrometry using a universal testing machine and magnified 35 times. No structural changes were detected on morphological surface characterization, only substrate accumulation. As for composition, there were concentration differences in the titanium, oxygen, and carbon elements. Implants with surface acid treatment undergo greater superficial changes in chemical composition than machined implants, that is, the greater the contact area of the implant with the substrate, the greater the oxide layer change. In addition, prior manipulation can alter the chemical composition of implants, typically to a greater degree in surface-treated implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the effect of implant length (6 mm vs. 11 mm) on osseointegration (bone-toimplant contact) of implants installed into sockets immediately after tooth extraction. Material and methods: In six Labrador dogs, the pulp tissue of the mesial roots of P-3(3) was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemisectioned and the distal roots removed. Recipient sites were prepared in the distal alveolus and a 6 mm or an 11 mm long implant was installed at the test and control sites, respectively. Non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment. Results: No statistically significant differences were found between test and control sites both for hard and soft tissue parameters. The bone-to-implant contact evaluated at the apical region of the implants was similar as well. Although not statistically significant, the location of the top of the bony crest at the buccal aspect was more apical in relation to the implant shoulder at the test compared with the control sites (2.0 +/- 1.4 and 1.2 +/- 1.1 mm, respectively). Conclusions: Shorter implants (6 mm) present with equal osseointegration than do longer implants (11 mm).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We tested the short-term effects of a nonrigid tool, identified as an "anchor system" (e.g., ropes attached to varying weights resting on the floor), on the postural stabilization of blindfolded adults with and without intellectual disabilities (ID). Participants held a pair of anchors one in each hand, under three weight conditions (250 g, 500 g and 1,000 g), while they performed a restricted balance task (standing for 30 s on a balance beam placed on top of a force platform). These conditions were called anchor practice trials. Before and after the practice trials, a condition without anchors was tested. Control practice groups, who practiced blocks of trials without anchors, included individuals with and without ID. The anchor system improved subjects' balance during the standing task, for both groups. For the control groups, the performance of successive trials in the condition without the anchor system showed no improvement in postural stability. The individuals with intellectual disability, as well as their peers without ID, used the haptic cues of nonrigid tools (i.e., the anchor system) to stabilize their posture, and the short-term stabilizing effects appeared to result from their previous use of the anchor system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’imballaggio alimentare si può definire come un sistema coordinato per disporre i beni per il trasporto, la distribuzione, la conservazione, la vendita e l’utilizzo. Uno dei materiali maggiormente impiegati, nell’industria alimentare, per la produzione di imballaggi sono le materie plastiche. Esse sono sostanze organiche derivanti da petrolio greggio, sono composti solidi allo stato finito, ma possono essere modellate allo stato fluido. Un imballaggio alimentare deve svolgere determinate funzioni tra cui: - contenimento del prodotto - protezione del prodotto da agenti esterni - logistica - comunicativa - funzionale - ecologica L'ultimo punto sopracitato è il principale problema delle materie plastiche derivanti dal petrolio greggio. Questi materiali sono difficilmente riciclabili perché spesso un imballaggio è composto da più materiali stratificati o perché si trova a diretto contatto con gli alimenti. Inoltre questi materiali hanno un lungo tempo di degradazione (da 100 a 1000 anni) che ne rendono difficile e costoso lo smaltimento. Per questo nell’ultimo decennio è cominciata la ricerca di un materiale plastico, flessibile alle esigenze industriali e nel contempo biodegradabile. Una prima idea è stata quella di “imitare la natura” cercando di replicare macromolecole già esistenti (derivate da amido e zuccheri) per ottenere una sostanza plastico-simile utilizzabile per gli stessi scopi, ma biodegradabile in circa sei mesi. Queste bioplastiche non hanno preso piede per l’alto costo di produzione e perché risulta impossibile riconvertire impianti di produzione in tutto il mondo in tempi brevi. Una seconda corrente di pensiero ha indirizzato i propri sforzi verso l’utilizzo di speciali additivi aggiunti in minima misura (1%) ai classici materiali plastici e che ne permettono la biodegradazione in un tempo inferiore ai tre anni. Un esempio di questo tipo di additivi è l’ECM Masterbatch Pellets che è un copolimero di EVA (etilene vinil acetato) che aggiunto alle plastiche tradizionali rende il prodotto finale completamente biodegradabile pur mantenendo le proprie caratteristiche. Scopo di questo lavoro di tesi è stato determinare le modificazioni di alcuni parametri qualitativi di nettarine di Romagna(cv.-Alexa®) confezionate-con-film-plastici-tradizionali-e-innovativi. I campioni di nettarine sono stati confezionati in cestini in plastica da 1 kg (sigillati con un film flow-pack macroforato) di tipo tradizionale in polipropilene (campione denominato TRA) o vaschette in polipropilene additivato (campione denominato BIO) e conservati a 4°C e UR 90-95% per 7 giorni per simulare un trasporto refrigerato successivamente i campioni sono stati posti in una camera a 20°C e U.R. 50% per 4 giorni al fine di simulare una conservazione al punto vendita. Al tempo 0 e dopo 4, 7, 9 e 11 giorni sono state effettuate le seguenti analisi: - coefficiente di respirazione è stato misurata la quantità di CO2 prodotta - indice di maturazione espresso come rapporto tra contenuto in solidi solubili e l’acidità titolabile - analisi di immagine computerizzata - consistenza della polpa del frutto è stata misurata attraverso un dinamometro Texture Analyser - contenuto in solidi totali ottenuto mediante gravimetria essiccando i campioni in stufa sottovuoto - caratteristiche sensoriali (Test Accettabilità) Conclusioni In base ai risultati ottenuti i due campioni non hanno fatto registrare dei punteggi significativamente differenti durante tutta la conservazione, specialmente per quanto riguarda i punteggi sensoriali, quindi si conclude che le vaschette biodegradabili additivate non influenzano la conservazione delle nettarine durante la commercializzazione del prodotto limitatamente ai parametri analizzati. Si ritiene opportuno verificare se il processo di degradazione del polimero additivato si inneschi già durante la commercializzazione della frutta e soprattutto verificare se durante tale processo vengano rilasciati dei gas che possono accelerare la maturazione dei frutti (p.e. etilene), in quanto questo spiegherebbe il maggiore tasso di respirazione e la più elevata velocità di maturazione dei frutti conservati in tali vaschette. Alimentary packaging may be defined as a coordinate system to dispose goods for transport, distribution, storage, sale and use. Among materials most used in the alimentary industry, for the production of packaging there are plastics materials. They are organic substances deriving from crude oil, solid compounds in the ended state, but can be moulded in the fluid state. Alimentary packaging has to develop determinated functions such as: - Product conteniment - Product protection from fieleders agents - logistic - communicative - functional - ecologic This last term is the main problem of plastic materials deriving from crude oil. These materials are hardly recyclable because a packaging is often composed by more stratified materials or because it is in direct contact with aliments. Beside these materials have a long degradation time(from 100 to 1000 years) that make disposal difficult and expensive. For this reason in the last decade the research for a new plastic material is begin, to make industrial demands more flexible and, at the same time, to make this material biodegradable: At first, the idea to “imitate the nature” has been thought, trying to reply macromolecules already existents (derived from amid and sugars) to obtain a similar-plastic substance that can be used for the same purposes, but it has to be biodegradable in about six months. These bioplastics haven’t more success bacause of the high production cost and because reconvert production facilities of all over the wolrd results impossible in short times. At second, the idea to use specials addictives has been thought. These addictives has been added in minim measure (1%) to classics plastics materials and that allow the biodegradation in a period of time under three years. An example of this kind of addictives is ECM Masterbatch Pellets which is a coplymer of EVA (Ethylene vinyl acetate) that, once it is added to tradizional plastics, make final product completely biodegradable however maintaining their own attributes. The objective of this thesis work has been to determinate modifications of some Romagna’s Nectarines’ (cv. Alexa®) qualitatives parameters which have been packaged-with traditional and innovative-plastic film. Nectarines’ samples have been packaged in plastic cages of 1 kg (sealed with a macro-drilled flow-pack film) of traditional type in polypropylene (sample named TRA) or trays in polypropylene with addictives (sample named BIO) and conservated at 4°C and UR 90-95% for 7 days to simulate a refrigerated transport. After that, samples have been put in a camera at 20°C and U.R. 50% for 4 days to simulate the conservation in the market point. At the time 0 and after 4, 7, 9 and 11 days have been done the following analaysis: - Respiration coefficient wherewith the amount CO2 producted has been misurated - Maturation index which is expressed as the ratio between solid soluble content and the titratable acidity - Analysis of computing images - Consistence of pulp of the fruit that has been measured through Texture Analyser Dynanometer - Content in total solids gotten throught gravimetry by the drying of samples in vacuum incubator - Sensorial characteristic (Panel Test) Consequences From the gotten results, the two samples have registrated no significative different scores during all the conservation, expecially about the sensorial scores, so it’s possible to conclude that addictived biodegradable trays don’t influence the Nectarines’ conservation during the commercialization of the product qualifiedly to analized parameters. It’s advised to verify if the degradation process of the addicted polymer may begin already during the commercialization of the fruit and in particular to verify if during this process some gases could be released which can accelerate the maturation of fruits (p.e. etylene), because all this will explain the great respiration rate and the high speed of the maturation of fruits conservated in these trays.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plutonium represents the major contribution to the radiotoxicity of spent nuclear fuel over storage times of up to several hundred thousand years. The speciation of plutonium in aquifer systems is important in order to assess the risks of high-level nuclear waste disposal and to acquire a deep knowledge of the mobilization and immobilization behavior of plutonium. In aqueous solutions, plutonium can coexist in four oxidation states and each one of them has different chemical and physical behavior. Tetravalent plutonium is the most abundant under natural conditions. Therefore, detailed speciation studies of tetravalent plutonium in contact with humic substances (HS) and kaolinite as a model clay mineral have been performed in this work. Plutonium is present in the environment at an ultratrace level. Therefore, speciation of Pu at the ultratrace level is mandatory. Capillary electrophoresis (CE) coupled to resonance ionization mass spectrometry (RIMS) was used as a new speciation method. CE-RIMS enables to improve the detection limit for plutonium species by 2 to 3 orders of magnitude compared to the previously developed CE-ICP-MS. For understanding the behavior of Pu(IV) in aqueous systems, redox reactions, complexation, and sorption behavior of plutonium were studied. The redox behavior of plutonium in contact with humic acid (HA) and fulvic acid (FA) was investigated. A relatively fast reduction of Pu(VI) in contact with HS was observed. It was mainly reduced to Pu(IV) and Pu(III) within a couple of weeks. The time dependence of the Pu(IV) complexation with Aldrich HA was investigated and a complex constant (logßLC) between 6.4 - 8.4 of Pu(IV) was determined by means of ultrafiltration taking into account the loading capacity (LC). The sorption of tetravalent plutonium onto kaolinite was investigated as a function of pH in batch experiments under aerobic and anaerobic conditions. The sorption edge was found at about pH = 1 and a maximum sorption at around pH = 8.5. In the presence of CO2 at pH > 8.5, the sorption of plutonium was decreased probably due to the formation of soluble carbonate complexes. For comparison, the sorption of Th(IV) onto kaolinite was also investigated and consistent results were found. The Pu(IV) sorption onto kaolinite was studied by XANES and EXAFS at pH 1, 4, 9 and the sorbed species on kaolinite surface was Pu(IV). Depending on the pH, only 1 - 10 % of the sorbed plutonium is desorbed from kaolinite and released into a fresh solution at the same pH value. Furthermore, the sorption of HS onto kaolinite was studied as a function of pH at varying concentrations of HS, as a prerequisite to understand the more complex ternary system. The sorption of HA onto kaolinite was found to be higher than that of FA. The investigation of the ternary systems (plutonium-kaolinite-humic substances) is performed as a function of pH, concentration of HS, and the sequences of adding the reactants. The presence of HS strongly influences the sorption of Pu(IV) onto kaolinite over the entire pH range. For comparison, the influence of HS on the sorption of Th(IV) onto kaolinite was also investigated and a good agreement with the results of Pu(IV) was obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work of the present thesis is focused on the implementation of microelectronic voltage sensing devices, with the purpose of transmitting and extracting analog information between devices of different nature at short distances or upon contact. Initally, chip-to-chip communication has been studied, and circuitry for 3D capacitive coupling has been implemented. Such circuits allow the communication between dies fabricated in different technologies. Due to their novelty, they are not standardized and currently not supported by standard CAD tools. In order to overcome such burden, a novel approach for the characterization of such communicating links has been proposed. This results in shorter design times and increased accuracy. Communication between an integrated circuit (IC) and a probe card has been extensively studied as well. Today wafer probing is a costly test procedure with many drawbacks, which could be overcome by a different communication approach such as capacitive coupling. For this reason wireless wafer probing has been investigated as an alternative approach to standard on-contact wafer probing. Interfaces between integrated circuits and biological systems have also been investigated. Active electrodes for simultaneous electroencephalography (EEG) and electrical impedance tomography (EIT) have been implemented for the first time in a 0.35 um process. Number of wires has been minimized by sharing the analog outputs and supply on a single wire, thus implementing electrodes that require only 4 wires for their operation. Minimization of wires reduces the cable weight and thus limits the patient's discomfort. The physical channel for communication between an IC and a biological medium is represented by the electrode itself. As this is a very crucial point for biopotential acquisitions, large efforts have been carried in order to investigate the different electrode technologies and geometries and an electromagnetic model is presented in order to characterize the properties of the electrode to skin interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine whether a real high speed-short term competition influences clinicopathological data focusing on muscle enzymes, iron profile and Acute Phase Proteins. 30 Thoroughbred racing horses (15 geldings and 15 females) aged between 4-12 years (mean 7 years), were used for the study. All the animals performed a high speed-short term competition for a total distance of 154 m in about 12 seconds, repeated 8 times, within approximately one hour (Niballo Horse Race). Blood samples were obtained 24 hours before and within 30 minutes after the end of the races. On all samples were performed a complete blood count (CBC), biochemical and haemostatic profiles. The post-race concentrations for the single parameter were corrected using an estimation of the plasma volume contraction according to the individual Alb concentration. Data were analysed with descriptive statistics and the percentage of variation from the baseline values were recorded. Pre- and post-race results were compared with non-parametric statistics (Mann Whitney U test). A difference was considered significant at p<0.05. A significant plasma volume contraction after the race was detected (Hct, Alb; p<0.01). Other relevant findings were increased concentrations of muscular enzymes (CK, LDH; p<0.01), Crt (p<0.01), significant increased uric acid (p<0.01), a significant decrease of haptoglobin (p<0.01) associated to an increase of ferritin concentrations (p<0.01), significant decrease of fibrinogen (p<0.05) accompanied by a non-significant increase of D-Dimers concentrations (p=0.08). This competition produced relevant abnormalities on clinical pathology in galloping horses. This study confirms a significant muscular damage, oxidative stress, intravascular haemolysis and subclinical hemostatic alterations. Further studies are needed to better understand the pathogenesis, the medical relevance and the impact on performance of these alterations in equine sport medicine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Light pseudoscalar bosons, such as the axion that was originally proposed as a solution of the strong CP problem, would cause a new spin-dependent short-range interaction. In this thesis, an experiment is presented to search for axion mediated short-range interaction between a nucleon and the spin of a polarized bound neutron. This interaction cause a shift in the precession frequency of nuclear spin-polarized gases in the presence of an unpolarized mass. To get rid of magnetic field drifts co-located, nuclear spin polarized 3He and 129Xe atoms were used. The free nuclear spin precession frequencies were measured in a homogeneous magnetic guiding field of about 350nT using LTc SQUID detectors. The whole setup was housed in a magnetically shielded room at the Physikalisch Technische Bundesanstalt (PTB) in Berlin. With this setup long nuclear spin-coherence times, respectively, transverse relaxation times of 5h for 129Xe and 53h for 3He could be achieved. The results of the last run in September 2010 are presented which give new upper limits on the scalar-pseudoscalar coupling of axion-like particles in the axion-mass window from 10^(-2) eV to 10^(-6) eV. The laboratory upper bounds were improved by up to 4 orders of magnitude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Delivery of therapeutic nucleic acid based drugs is still very demanding and difficult to manage and monitor. For this reason, a precise method for the monitoring of RNAi pathways is necessary. This thesis explores a new approach for sensing of potentially therapeutic nucleic acids, using the interaction of so called prodyes with intracellular enzymes in a prodrug manner. To realize this concept, some non-fluorescent, fluorescein based asymmetric dyes were synthesized and their spectroscopic characteristics were studied. Azide-alkyne Click chemistry was applied for conjugation purposes, using a new protocol at weak acidic pH to get intact prodye constructs. Both, an electrophoretic mobility shift assay with polyacrylamide gels and in-cuvette experiments showed remarkable OFF-to-ON behavior of these new siRNA constructs under physiological conditions. After salt-free purification, subsequent hybridization to double-stranded ribonucleic acids and nanoformulation to lipoplexes, the prodye conjugated siRNA was examined in cellular uptake studies for First Contact Imaging. The investigated siRNA-prodye conjugates showed strong sensitivity to esterases, being hydrolyzed at the biolabile function and developing a strong fluorescence which was verified in bulk. As an optimization, a new profluorescent molecule system was designed and synthesized, which has a carbonate as biolabile 6’ protecting group and a highly water soluble 3’ clickable linker. This new non-fluorescent but colored prodye showed 12 - 320 times increased fluorescence intensities between OFF- and ON- states, depending to the deprotection method. This is the first reported molecule model of an asymmetric profluorescent fluorescein, having the very favorable 3’ &amp;amp; 6’ functions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In contact shots, all the materials emerging from the muzzle (combustion gases, soot, powder grains, and metals from the primer) will be driven into the depth of the entrance wound and the following sections of the bullet track. The so-called "pocket" ("powder cavity") under the skin containing soot and gunpowder particles is regarded as a significant indicator of a contact entrance wound since one would expect that the quantity of GSR deposited along the bullet's path rapidly declines towards the exit hole. Nevertheless, experience has shown that soot, powder particles, and carboxyhemoglobin may be found not only in the initial part of the wound channel, but also far away from the entrance and even at the exit. In order to investigate the propagation of GSRs under standardized conditions, contact test shots were fired against composite models of pig skin and 25-cm-long gelatin blocks using 9-mm Luger pistol cartridges with two different primers (Sinoxid® and Sintox®). Subsequently, 1-cm-thick layers of the gelatin blocks were examined as to their primer element contents (lead, barium, and antimony as discharge residues of Sinoxid® as well as zinc and titanium from Sintox®) by means of X-ray fluorescence spectroscopy. As expected, the highest element concentrations were found in the initial parts of the bullet tracks, but also the distal sections contained detectable amounts of the respective primer elements. The same was true for amorphous soot and unburned/partly burned powder particles, which could be demonstrated even at the exit site. With the help of a high-speed motion camera it was shown that for a short time the temporary cavitation extends from the entrance to the exit thus facilitating the unlimited spread of discharge residues along the whole bullet path.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Introduction Vertebroplasty (VP) is a cost-efficient alternative to kyphoplasty; however, regarding safety and vertebral body (VB) height restoration, it is considered inferior. We assessed the safety and efficacy of VP in alleviating pain, improving quality of life (QoL) and restoring alignment. Methods In a prospective monocenter case series from May 2007 until July 2008, there were 1,408 vertebroplasties performed during 319 interventions in 306 patients with traumatic, lytic and osteoporotic fractures. The 249 interventions in 233 patients performed because of osteoporotic vertebral fractures were analyzed regarding demographics, treatment and radiographic details, pain alleviation (VAS), QoL improvement (NASS and EQ-5D), complications and predictors for new fractures requiring a reoperation. Results The osteoporotic patient sample consisted of 76.7% (179) females with a median age of 80 years. A total of 54 males had a median age of 77 years. On average, there were 1.8 VBs fractured and 5 VBs treated. The preoperative pain was assessed by the visual analog scale (VAS) and decreased from 54.9 to 40.4 pts after 2 months and 31.2 pts after 6 months. Accordingly, the QoL on the EQ-5D measure (−0.6 to 1) improved from 0.35 pts before surgery to 0.56 pts after 2 and to 0.68 pts after 6 months. The preoperative Beck Index (anterior height/posterior height) improved from a mean of 0.64 preoperative to 0.76 postoperative, remained stable at 2 months and slightly deteriorated to 0.72 at 6 months postoperatively. There were cement leakages in 26% of the fractured VBs and in 1.4% of the prophylactically cemented VBs; there were symptoms in 4.3%, and most of them were temporary hypotension and one pulmonary cement embolism that remained asymptomatic. The univariate regression model revealed a tendency for a reduced risk for new or refractures on radiographs (OR = 2.61, 95% CI 0.92–7.38, p = 0.12) and reoperations (OR = 2.9, 95% CI 0.94–8.949, p = 0.1) when prophylactic augmentation was performed. The final multivariate regression model revealed male patients to have an about three times higher refracture risk (radiographic) (OR = 2.78, p = 0.02) at 6 months after surgery. Patients with a lumbar index fracture had an about three to five times higher refracture/reoperation risk than patients with a thoracic (OR = 0.33/0.35, p = 0.009/0.01) or thoracolumbar (OR = 0.32/0.22, p = 0.099/0.01) index fracture. Conclusion If routinely used, VP is a safe and efficacious treatment option for osteoporotic vertebral fractures with regard to pain relief and improvement of the QoL. Even segmental realignment can be partially achieved with proper patient positioning. Certain patient or fracture characteristics increase the risk for early radiographic refractures or new fractures, or a reoperation; a consequent prophylactic augmentation showed protective tendencies, but the study was underpowered for a final conclusion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Glycoprotein VI (GPVI) is a key platelet receptor which mediates plaque-induced platelet activation and consecutive atherothrombosis, but GPVI is also involved in platelet-mediated atheroprogression. Therefore, interference in GPVI-mediated platelet activation has the potential to combine short-term and long-term beneficial effects, specificity and safety especially regarding bleeding complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the results of a unique "natural experiment" of the operation and cessation of a broadcast transmitter with its short-wave electromagnetic fields (6-22 MHz) on sleep quality and melatonin cycle in a general human population sample. In 1998, 54 volunteers (21 men, 33 women) were followed for 1 week each before and after shut-down of the short-wave radio transmitter at Schwarzenburg (Switzerland). Salivary melatonin was sampled five times a day and total daily excretion and acrophase were estimated using complex cosinor analysis. Sleep quality was recorded daily using a visual analogue scale. Before shut down, self-rated sleep quality was reduced by 3.9 units (95% CI: 1.7-6.0) per mA/m increase in magnetic field exposure. The corresponding decrease in melatonin excretion was 10% (95% CI: -32 to 20%). After shutdown, sleep quality improved by 1.7 units (95% CI: 0.1-3.4) per mA/m decrease in magnetic field exposure. Melatonin excretion increased by 15% (95% CI: -3 to 36%) compared to baseline values suggesting a rebound effect. Stratified analyses showed an exposure effect on melatonin excretion in poor sleepers (26% increase; 95% CI: 8-47%) but not in good sleepers. Change in sleep quality and melatonin excretion was related to the extent of magnetic field reduction after the transmitter's shut down in poor but not good sleepers. However, blinding of exposure was not possible in this observational study and this may have affected the outcome measurements in a direct or indirect (psychological) way.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Geometrical dependencies are being researched for analytical representation of the probability density function (pdf) for the travel time between a random, and a known or another random point in Tchebyshev’s metric. In the most popular case - a rectangular area of service - the pdf of this random variable depends directly on the position of the server. Two approaches have been introduced for the exact analytical calculation of the pdf: Ad-hoc approach – useful for a ‘manual’ solving of a specific case; by superposition – an algorithmic approach for the general case. The main concept of each approach is explained, and a short comparison is done to prove the faithfulness.