727 resultados para Relining denture


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The double system of support, in which the distal-extension removable partial denture adapts, causes inadequate stress around abutment teeth, increasing the possibility of unequal bone resorption. Several ways to reduce or more adequately distribute the stress between abutment teeth and residual ridges have been reported; however, there are no definitive answers to the problem. The purpose of this study was to analyze, by means of photoelasticity, the most favorable stress distribution using three retainers: T bar, rest, proximal plate, I bar (RPI), and circumferential with mesialized rest. Materials and Methods: Three photoelastic models were made simulating a Kennedy Class II inferior arch. Fifteen dentures with long saddles, five of each design, were adjusted to the photoelastic patterns and submitted first to uniformly distributed load, and then to a load localized on the last artificial tooth. The saddles were then shortened and the tests repeated. The quantitative and qualitative analyses of stress intensity were done manually and by photography, respectively. For intragroup analyses the Wilcoxon test for paired samples was used, while for intergroup analyses Friedman and Wilcoxon tests were used to better identify the differences (p < 0.05). Results: The RPI retainer, followed by the T bar, demonstrated the best distribution of load between teeth and residual ridge. The circumferential retainer caused greater concentration of stress between dental apexes. Stress distribution was influenced by the type of retainer, the length of the saddle, and the manner of load application. Conclusions: The long saddles and the uniformly distributed loads demonstrated better distribution of stress on support structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400 000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (alpha = 0 center dot 05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10 center dot 6 +/- 3 center dot 6 and 66 center dot 4 +/- 16 center dot 0, respectively). However, differences were not significant after 400 000 loads (7 center dot 9 +/- 4 center dot 3 and 21 center dot 6 +/- 17 center dot 0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of artificial accelerated aging on dimensional stability of two types of acrylic resins (thermally and chemically activated) submitted to different protocols of storage. Materials and Methods: One hundred specimens were made using a Teflon matrix (1.5cmx0.5mm) with four imprint marks, following the lost-wax casting method. The specimens were divided into ten groups, according to the type of acrylic resin, aging procedure, and storage protocol (30 days). GI: acrylic resins thermally activated, aging, storage in artificial saliva for 16 hours, distilled water for 8 hours; GII: thermal, aging, artificial saliva for 16 hours, dry for 8 hours; GIII: thermal, no aging, artificial saliva for 16 hours, distilled water for 8 hours, GIV: thermal, no aging, artificial saliva for 16 hours, dry for 8 hours; GV: acrylic resins chemically activated, aging, artificial saliva for 16 hours, distilled water for 8 hours; GVI: chemical, aging, artificial saliva for 16 hours, dry for 8 hours; GVII: chemical, no aging, artificial saliva for 16 hours, distilled water for 8 hours; GVIII: chemical, no aging, artificial saliva for 16 hours, dry for 8 hours GIX: thermal, dry for 24 hours; and GX: chemical, dry for 24 hours. All specimens were photographed before and after treatment, and the images were evaluated by software (UTHSCSA-Image Tool) that made distance measurements between the marks in the specimens (mm), calculating the dimensional stability. Data were submitted to statistical analysis (two-way ANOVA, Tukey test, p = 0.05). Results: Statistical analysis showed that the specimens submitted to storage in water presented the largest distance between both axes (major and minor), statistically different (p < 0.05) from control groups. Conclusions: All acrylic resins presented dimensional changes, and the artificial accelerated aging and storage period influenced these alterations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of the incorporation of the antimicrobial monomer methacryloyloxyundecylpyridinium bromide (MUPB) on the hardness, roughness, flexural strength, and color stability of a denture base material. Materials and Methods: Ninety-six disk-shaped (14-mm diameter x 4-mm thick) and 30 rectangular (65 x 10 x 3.3 mm(3)) heat-polymerized acrylic resin specimens were divided into three groups according to the concentration of MUPB (w/w): (A) 0%, (B) 0.3%, (C) 0.6%. Hardness was assessed by a hardness tester equipped with a Vickers diamond penetrator. Flexural strength and surface roughness were tested on a universal testing machine and a surface roughness tester, respectively. Color alterations (Delta E) were measured by a portable spectrophotometer after 12 and 36 days of immersion in water, coffee, or wine. Variables were analyzed by ANOVA/Tukey HSD test (alpha = 0.05). Results: The following mean results (+/-SD) were obtained for hardness (A: 15.6 +/- 0.6, B: 14.6 +/- 1.7, C: 14.8 +/- 0.8 VHN; ANOVA: p = 0.061), flexural strength (A: 111 +/- 17, B: 105 +/- 12, C: 88 +/- 12 MPa; ANOVA: p = 0.008), and roughness (A: 0.20 +/- 0.11, B: 0.20 +/- 0.11, C: 0.24 +/- 0.08 mu m; ANOVA: p = 0.829). Color changes of immersed specimens were significantly influenced by solutions and time (A: 9.1 +/- 3.1, B: 14.8 +/- 7.5, C: 13.3 +/- 6.1 Delta E; ANOVA: p < 0.05). Conclusions: The incorporation of MUPB affects the mechanical properties of a denture base acrylic resin; however, the only significant change was observed for flexural strength and may not be critical. Color changes were slightly higher when resin containing MUPB was immersed in wine for a prolonged time; however, the difference has debatable clinical relevance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Patients who play musical instruments (especially wind and stringed instruments) and vocalists are prone to particular types of orofacial problems. Some problems are caused by playing and some are the result of dental treatment. This paper proposes to give an insight into these problems and practical guidance to general practice dentists. Method: Information in this paper is gathered from studies published in dental, music and occupational health journals, and from discussions with career musicians and music teachers. Results: Orthodontic problems, soft tissue trauma, focal dystonia, denture retention, herpes labialis, dry mouth and temporomandibular joint (TMJ) disorders were identified as orofacial problems of career musicians. Options available for prevention and palliative treatment as well as instrument selection are suggested to overcome these problems. Conclusions: Career musicians express reluctance to attend dentists who are not sensitive to their specific needs. General practitioner dentists who understand how the instruments impact on the orofacial structures and are aware of potential problems faced by musicians are able to offer preventive advice and supportive treatment to these patients, especially those in the early stages of their career.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the association between oral candidiasis in elderly users and nonusers of prosthesis and its predisposing factors. To this end, we performed a cross-sectional study where saliva samples from 48 patients were collected they used prosthesis and 43 patients (control group) who did not use. Among the 91 patients, Candida spp were isolated in 40 (83.3%) who used prosthesis and in 23 (53.5%) in the control group. A statistically significant association was determined between the two groups, the isolation of yeasts and dental prosthesis (p < 0.05, OR = 4.3). The most common etiological agent was Candida albicans (37 isolates), with 23 (62.2%) in the denture group and 14 (37.8%) (control group). Among patients who presented clinical manifestations of oral candidiasis (n = 24), 83.3% (n = 20) belonged to the group that wore dentures, while only 16.7% (n = 4) belonged to the control group. Elderly patients with diabetes had 4.4 times higher estimated risk of developing oral candidiasis when compared with individuals without this condition. There was no statistically significant association between being user prostheses and have diabetes with the onset of candidiasis. No statistically significant association was determined between xerostomia, use of prosthesis and oral candidiasis. The use of prosthetics and poor oral hygiene in elderly patients predisposes to the development of oral candidiasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Exert] This chapter is focused on the activity of silver nanoparticles (SN) as an antifungal agent against Candida albicans and Candida glabrata biofilms, which are involved in oral candidosis. A discussion focusing on the influence of the stabilizing agent, diameter of SN on its antibiofilm activity, influence of chemical stability of SN on Candida biofilms, the effect of SN against adhered cells and biofilms, the effect on extracellular matrix composition and structure of Candida biofilms, the combination of SN with conventional antifungal drugs, and the incorporation of SN into denture acrylic resin is incorporated in the present chapter. Because of the resistance of Candida biofilms to conventional drugs and the positive effect of SN against them, these nanoparticles can be used as an alternative antifungal agent (...).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis is a continuation of the Enterprise-Ireland Research Innovation Fund (RIF) Project entitled’ "Design and Manufacturing of Customised Maxillo-Facial Prostheses" The primary objective of this Internal Research Development Program (IRDP) project was to investigate two fundamental design changes 1 To incorporate the over-denture abutments directly into the implant. 2 To remove the restraining wings by the addition of screws, which affix the. implant to the dense material of the jawbone. The prosthetic was redesigned using the ANSYS Finite Element Analysis software program and analysed to* • Reduce the internal von Mises stress distribution The new prosthetic had a -63.63 % lower von Mises stress distribution when compared with the original prosthetic. • Examine the screw preload effects. A maximum relative displacement of 22 6 * lO^mm between the bone and screw was determined, which is well below the critical threshold of micromotion which prevents osseointegration • Investigate the prosthetic-bone contact interface. Three models of the screw, prosthesis, and bone, were studied. (Axisymmetnc, quarter volume, and full volume), a recommended preload torque of 0 32 Nm was applied to the prosthetic and a maximum von Mises stress of 1.988 MPa was predicted • Study the overdenture removal forces. This analysis could not be completed because the correct plastic multilinear properties of the denture material could not be established The redesigned prosthetic was successfully manufactured on a 3-axis milling machine with an indexing system The prosthetic was examined for dimensional quality and strength The research established the feasibility of the new design and associated manufacturing method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: The difficulty of identifying the ownership of lost dentures when found is a common and expensive problem in long term care facilities (LTCFs) and hospitals. PURPOSE: The purpose of this study was to evaluate the reliability of using radiofrequency identification (RFID) in the identification of dentures for LTCF residents after 3 and 6 months. MATERIAL AND METHODS: Thirty-eight residents of 2 LTCFs in Switzerland agreed to participate after providing informed consent. The tag was programmed with the family and first names of the participants and then inserted in the dentures. After placement of the tag, the information was read. A second and third assessment to review the functioning of the tag occurred at 3 and 6 months, and defective tags (if present) were reported and replaced. The data were analyzed with descriptive statistics. RESULTS: At the 3-month assessment of 34 residents (63 tags) 1 tag was unreadable and 62 tags (98.2%) were operational. At 6 months, the tags of 27 of the enrolled residents (50 tags) were available for review. No examined tag was defective at this time period. CONCLUSIONS: Within the limits of this study (number of patients, 6-month time span) RFID appears to be a reliable method of tracking and identifying dentures, with only 1 of 65 devices being unreadable at 3 months and 100% of 50 initially placed tags being readable at the end of the trial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to compare the use of different variables to measure the clinical wear of two denture tooth materials in two analysis centers. METHODS: Twelve edentulous patients were provided with full dentures. Two different denture tooth materials (experimental material and control) were placed randomly in accordance with the split-mouth design. For wear measurements, impressions were made after an adjustment phase of 1-2 weeks and after 6, 12, 18, and 24 months. The occlusal wear of the posterior denture teeth of 11 subjects was assessed in two study centers by use of plaster replicas and 3D laser-scanning methods. In both centers sequential scans of the occlusal surfaces were digitized and superimposed. Wear was described by use of four different variables. Statistical analysis was performed after log-transformation of the wear data by use of the Pearson and Lin correlation and by use of a mixed linear model. RESULTS: Mean occlusal vertical wear of the denture teeth after 24 months was between 120μm and 212μm, depending on wear variable and material. For three of the four variables, wear of the experimental material was statistically significantly less than that of the control. Comparison of the two study centers, however, revealed correlation of the wear variables was only moderate whereas strong correlation was observed among the different wear variables evaluated by each center. SIGNIFICANCE: Moderate correlation was observed for clinical wear measurements by optical 3D laser scanning in two different study centers. For the two denture tooth materials, wear measurements limited to the attrition zones led to the same qualitative assessment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bisphosphonate related osteonecrosis of the jaw (BRONJ) is defined as exposed necrotic bone appearing in the jaws of patients treated by systemic IV or oral BPs never irradiated in the head and neck area and that has persisted for more than 8 weeks. More than 90% of cases of osteonecrosis of the jaw have been in patients with cancer who received IV-BPs. The estimate of cumulative incidence of BRONJ in cancer patients with IV-BPs ranges from 0.8% to 18.6%. The pathogenesis of BRONJ appeared related to the potent osteoblast-inhibiting properties of BPs which act by blocking osteoclast recruitment, decreasing osteoclast activity and promoting osteoclast apoptosis. Dental extractions are the most potent local risk factor. Cancer patients wearing a denture could also be at increased risk of BRONJ. Non-healing mucosal breaches caused by dentures could be a portal for the oral flora to access bone, while the oral mucosa of patients on IV-BPs could also be defective. Whether periodontal disease is a risk factor for BRONJ remains controversial. Preventive measures are fundamental. Nevertheless, some teams have questioned its cost-effectiveness. The perceived limitations of surgical therapy of BRONJ led to the restriction of aggressive surgery to symptomatic patients with stage 3 BRONJ. The evidence-based literature on BRONJ is growing but there are still many controversial aspects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients. PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables. MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05). RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject. CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.