949 resultados para Reduced-basis method
Resumo:
Objective. To assess the immunogenicity and safety of non-adjuvanted influenza A H1N1/2009 vaccine in patients with juvenile autoimmune rheumatic disease (ARD) and healthy controls, because data are limited to the adult rheumatologic population. Method's. A total of 237 patients with juvenile ARD [juvenile systemic lupus erythematosus (JSLE), juvenile idiopathic arthritis (JIA), juvenile dermatomyositis (JDM), juvenile scleroderma, and vasculitis] and 91 healthy controls were vaccinated. Serology for anti-H1N1 was performed by hemagglutination inhibition assay. Seroprotection rate, seroconversion rate, and factor-increase in geometric mean titer (GMT) were calculated. Adverse events were evaluated. Results. Age was comparable in patients and controls (14.8 +/- 3.0 vs 14.6 +/- 3.7 years, respectively; p = 0.47). Three weeks after immunization, seroprotection rate (81.4% vs 95.6%; p = 0.0007), seroconversion rate (74.3 vs 95.6%; p < 0.0001), and the factor-increase in GMT (12.9 vs 20.3; p = 0.012) were significantly lower in patients with juvenile ARD versus controls. Subgroup analysis revealed reduced seroconversion rates in JSLE (p < 0.0001), JIA (p = 0.008), JDM (p = 0.025), and vasculitis (p = 0.017). Seroprotection (p < 0.0001) and GMT (p < 0.0001) were decreased only in JSLE. Glucocorticoid use and lymphopenia were associated with lower seroconversion rates (60.4 vs 82.9%; p = 0.0001; and 55.6 vs 77.2%; p = 0.012). Multivariate logistic regression including diseases, lymphopenia, glucocorticoid, and immunosuppressants demonstrated that only glucocorticoid use (p = 0.012) remained significant. Conclusion. This is the largest study to demonstrate a reduced but adequate immune response to H1N1 vaccine in patients with juvenile ARD. It identified current glucocorticoid use as the major factor for decreased antibody production. The short-term safety results support its routine recommendation for patients with juvenile ARD. ClinicalTrials.gov; NCT01151644. (First Release Nov 15 2011; J Rheumatol 2012;39:167-73; doi:10.3899/jrheum.110721)
Resumo:
The molecular method is used to obtain nuclear electric quadrupole moment (NQM) values for hafnium through electric field gradients (EFGs) at this nucleus in HfO and HfS. Dirac-Coulomb calculations with the Coupled Cluster approach, DC-CCSD (T) and DC-CCSD-T, were carried out to achieve the most accurate estimates of these EFGs. Higher order corrections are also added. Hence, the most reliable values for 177Hf and 179Hf determined here are 3319(33) and 3750(37) mbarn, respectively, in nice accordance with the best currently accepted NQMs for this element. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The availability and uptake of Cd by lettuce (Lactuca sativa L.) in two common tropical soils (before and after liming) were studied in order to derive human health-based risk soil concentration. Cadmium concentrations ranging from 1 to 12 mg kg(-1) were added to samples from a clayey Oxisol and a sandy-loam Ultisol under glasshouse conditions. After incubation, a soil sample was taken from each pot, the concentration of Cd in the soil was determined, lettuce was grown during 36 d, and the edible parts were harvested and analyzed for Cd. A positive linear correlation was observed between total soil Cd and the Cd concentration in lettuce. The amount of Cd absorbed by lettuce grown in the Ultisol was about twice the amount absorbed in the Oxisol. Liming increased the soil pH and slightly reduced Cd availability and uptake. CaCl2 extraction was better than DTPA to reflect differences in binding strength of Cd between limed and unlimed soils. Risk Cd concentrations in the Ultisol were lower than in the Oxisol, reflecting the greater degree of uptake from the Ultisol. The derived risk Cd values were dependent on soil type and the exposure scenario.
Resumo:
Abstract Background The aim of the present study was to investigate the relationship between speed during maximum exercise test (ET) and oxygen consumption (VO2) in control and STZ-diabetic rats, in order to provide a useful method to determine exercise capacity and prescription in researches involving STZ-diabetic rats. Methods Male Wistar rats were divided into two groups: control (CG, n = 10) and diabetic (DG, n = 8). The animals were submitted to ET on treadmill with simultaneous gas analysis through open respirometry system. ET and VO2 were assessed 60 days after diabetes induction (STZ, 50 mg/Kg). Results VO2 maximum was reduced in STZ-diabetic rats (72.5 ± 1 mL/Kg/min-1) compared to CG rats (81.1 ± 1 mL/Kg/min-1). There were positive correlations between ET speed and VO2 (r = 0.87 for CG and r = 0.8 for DG), as well as between ET speed and VO2 reserve (r = 0.77 for CG and r = 0.7 for DG). Positive correlations were also obtained between measured VO2 and VO2 predicted values (r = 0.81 for CG and r = 0.75 for DG) by linear regression equations to CG (VO2 = 1.54 * ET speed + 52.34) and DG (VO2 = 1.16 * ET speed + 51.99). Moreover, we observed that 60% of ET speed corresponded to 72 and 75% of VO2 reserve for CG and DG, respectively. The maximum ET speed was also correlated with VO2 maximum for both groups (CG: r = 0.7 and DG: r = 0.7). Conclusion These results suggest that: a) VO2 and VO2 reserve can be estimated using linear regression equations obtained from correlations with ET speed for each studied group; b) exercise training can be prescribed based on ET in control and diabetic-STZ rats; c) physical capacity can be determined by ET. Therefore, ET, which involves a relatively simple methodology and low cost, can be used as an indicator of cardio-respiratory capacity in future studies that investigate the physiological effect of acute or chronic exercise in control and STZ-diabetic male rats.
Resumo:
Abstract Background To establish the correlation between quantitative analysis based on B-mode ultrasound images of vulnerable carotid plaque and histological examination of the surgically removed plaque, on the basis of a videodensitometric digital texture characterization. Methods Twenty-five patients (18 males, mean age 67 ± 6.9 years) admitted for carotid endarterectomy for extracranial high-grade internal carotid artery stenosis (≥ 70% luminal narrowing) underwent to quantitative ultrasonic tissue characterization of carotid plaque before surgery. A computer software (Carotid Plaque Analysis Software) was developed to perform the videodensitometric analysis. The patients were divided into 2 groups according to symptomatology (group I, 15 symptomatic patients; and group II, 10 patients asymptomatic). Tissue specimens were analysed for lipid, fibromuscular tissue and calcium. Results The first order statistic parameter mean gray level was able to distinguish the groups I and II (p = 0.04). The second order parameter energy also was able to distinguish the groups (p = 0,02). A histological correlation showed a tendency of mean gray level to have progressively greater values from specimens with < 50% to >75% of fibrosis. Conclusion Videodensitometric computer analysis of scan images may be used to identify vulnerable and potentially unstable lipid-rich carotid plaques, which are less echogenic in density than stable or asymptomatic, more densely fibrotic plaques.
Resumo:
Acute promyelocytic leukemia is characterized by gene rearrangements that always involve the retinoic acid receptor alpha on chromosome 15. In the majority of patients t(15;17) is detected, which generates the promyelocytic leukemia gene/retinoic acid receptor alpha rearrangement. This rearrangement interacts with several proteins, including the native promyelocytic leukemia gene, thus causing its delocalization from the nuclear bodies, impairing its function. The immunofluorescence staining technique using the anti-PML antibody may be used to provide a rapid diagnosis and to immediately start therapy using all-trans retinoic acid. The experience of the International Consortium on Acute Promyelocytic Leukemia has demonstrated that early mortality was significantly reduced by adopting the immunofluorescence technique. All-trans retinoic acid combined with chemotherapy is the standard therapy; this promotes complete remission rates greater than 90% and cure rates of nearly 80%. However, early mortality is still an important limitation and hematologists must be aware of the importance of treating newly diagnosed acute promyelocytic leukemia as a medical emergency.
Resumo:
Background: We aimed to establish values and parameters using multislice reconstruction in axial computerized tomography (CT) in order to quantify the erosion of the glenoid cavity in cases of shoulder instability. Methods: We studied two groups using CT. Group I had normal subjects and Group II had patients with shoulder instability. We measured values of the vertical segment, the superior horizontal, medial and inferior segments, and also calculated the ratio of the horizontal superior and inferior segments of the glenoid cavity in both normal subjects and those with shoulder instability. These variables were recorded during arthroscopy for cases with shoulder instability. Results The mean values were 40.87 mm, 17.86 mm, 26.50 mm, 22.86 mm and 0.79 for vertical segment, the superior horizontal, medial and inferior segments, and the ratio between horizontal superior and inferior segments of the glenoid cavity respectively, in normal subjects. For subjects with unstable shoulders the mean values were 37.33 mm, 20.83 mm, 23.07 mm and 0.91 respectively. Arthroscopic measurements yielded an inferior segment value of 24.48 mm with a loss of 2.39 mm (17.57%). The ratio between the superior and inferior segments of the glenoid cavity was 0.79. This value can be used as a normative value for evaluating degree of erosion of the anterior border of the glenoid cavity. However, values found using CT should not be used on a comparative basis with values found during arthroscopy. Conclusions: Computerized tomographic measurements of the glenoid cavity yielded reliable values consistent with those in the literature.
Resumo:
Piezoelectric ceramics, such as PZT, can generate subnanometric displacements, bu t in order to generate multi- micrometric displacements, they should be either driven by high electric voltages (hundreds of volts ), or operate at a mechanical resonant frequency (in narrow band), or have large dimensions (tens of centimeters). A piezoelectric flextensional actuator (PFA) is a device with small dimensions that can be driven by reduced voltages and can operate in the nano- and micro scales. Interferometric techniques are very adequate for the characterization of these devices, because there is no mechanical contact in the measurement process, and it has high sensitivity, bandwidth and dynamic range. A low cost open-loop homodyne Michelson interferometer is utilized in this work to experimentally detect the nanovi brations of PFAs, based on the spectral analysis of the interfero metric signal. By employing the well known J 1 ...J 4 phase demodulation method, a new and improved version is proposed, which presents the following characteristics: is direct, self-consistent, is immune to fading, and does not present phase ambiguity problems. The proposed method has resolution that is similar to the modified J 1 ...J 4 method (0.18 rad); however, differently from the former, its dynamic range is 20% larger, does not demand Bessel functions algebraic sign correction algorithms and there are no singularities when the static phase shift between the interferometer arms is equal to an integer multiple of /2 rad. Electronic noise and random phase drifts due to ambient perturbations are taken into account in the analysis of the method. The PFA nanopositioner characterization was based on the analysis of linearity betw een the applied voltage and the resulting displacement, on the displacement frequency response and determination of main resonance frequencies.
Resumo:
Trabajo realizado por: Maldonado, F.; Packard, T.; Gómez, M.; Santana Rodríguez, J. J
Resumo:
This thesis deals with two important research aspects concerning radio frequency (RF) microresonators and switches. First, a new approach for compact modeling and simulation of these devices is presented. Then, a combined process flow for their simultaneous fabrication on a SOI substrate is proposed. Compact models for microresonators and switches are extracted by applying mathematical model order reduction (MOR) to the devices finite element (FE) description in ANSYS c° . The behaviour of these devices includes forms of nonlinearities. However, an approximation in the creation of the FE model is introduced, which enables the use of linear model order reduction. Microresonators are modeled with the introduction of transducer elements, which allow for direct coupling of the electrical and mechanical domain. The coupled system element matrices are linearized around an operating point and reduced. The resulting macromodel is valid for small signal analysis around the bias point, such as harmonic pre-stressed analysis. This is extremely useful for characterizing the frequency response of resonators. Compact modelling of switches preserves the nonlinearity of the device behaviour. Nonlinear reduced order models are obtained by reducing the number of nonlinearities in the system and handling them as input to the system. In this way, the system can be reduced using linear MOR techniques and nonlinearities are introduced directly in the reduced order model. The reduction of the number of system nonlinearities implies the approximation of all distributed forces in the model with lumped forces. Both for microresonators and switches, a procedure for matrices extraction has been developed so that reduced order models include the effects of electrical and mechanical pre-stress. The extraction process is fast and can be done automatically from ANSYS binary files. The method has been applied for the simulation of several devices both at devices and circuit level. Simulation results have been compared with full model simulations, and, when available, experimental data. Reduced order models have proven to conserve the accuracy of finite element method and to give a good description of the overall device behaviour, despite the introduced approximations. In addition, simulation is very fast, both at device and circuit level. A combined process-flow for the integrated fabrication of microresonators and switches has been defined. For this purpose, two processes that are optimized for the independent fabrication of these devices are merged. The major advantage of this process is the possibility to create on-chip circuit blocks that include both microresonators and switches. An application is, for example, aswitched filter bank for wireless transceiver. The process for microresonators fabrication is characterized by the use of silicon on insulator (SOI) wafers and on a deep reactive ion etching (DRIE) step for the creation of the vibrating structures in single-crystal silicon and the use of a sacrificial oxide layer for the definition of resonator to electrode distance. The fabrication of switches is characterized by the use of two different conductive layers for the definition of the actuation electrodes and by the use of a photoresist as a sacrificial layer for the creation of the suspended structure. Both processes have a gold electroplating step, for the creation of the resonators electrodes, transmission lines and suspended structures. The combined process flow is designed such that it conserves the basic properties of the original processes. Neither the performance of the resonators nor the performance of the switches results affected by the simultaneous fabrication. Moreover, common fabrication steps are shared, which allows for cheaper and faster fabrication.
Resumo:
The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.
Resumo:
[EN]We present a new method to construct a trivariate T-spline representation of complex solids for the application of isogeometric analysis. We take a genus-zero solid as a basis of our study, but at the end of the work we explain the way to generalize the results to any genus solids. The proposed technique only demands a surface triangulation of the solid as input data. The key of this method lies in obtaining a volumetric parameterization between the solid and the parametric domain, the unitary cube. To do that, an adaptive tetrahedral mesh of the parametric domain is isomorphically transformed onto the solid by applying a mesh untangling and smoothing procedure...
Resumo:
Die Synthese funktionalisierter Polyorganosiloxan-µ-Netzwerke (Rh = 5 30 nm) gelingt durch Polycokondensation von Alkoxysilanen. Die entstehenden sphärischen Teilchen sind in unpolaren organischen Lösungsmitteln partikulär dispergierbar. Durch die sequentielle Zugabe der Silanmonomere können Kern-Schale-Partikel mit unterschiedlichen Teilchenarchitekturen realisiert werden. In der vorliegenden Arbeit wird p-Chlormethylphenyltrimethoxysilan als funktionalisiertes Monomer verwendet, um den µ-Netzwerken durch eine anschließende Quaternisierung der Chlorbenzylgruppen mit Dimethylaminoethanol amphiphile Eigenschaften zu verleihen. Durch den Kern-Schale-Aufbau der Partikel sind die hydrophilen Bereiche im Kugelinneren von der hydrophoben äußeren Schale separiert, was unerläßlich für die Verwendung der Partikel zur Verkapselung wasserlöslicher Substanzen ist.So können in den amphiphilen µ-Netzwerken beispielsweise wasserlösliche Farbstoffe verkapselt werden. Diese diffundieren sowohl aus Lösung als auch aus dem Festkörper in das geladene Partikelinnere und werden dort angereichert. Es wird eine Abhängigkeit der Farbstoffbeladung vom Quaternisierungsgrad gefunden, wobei die Anzahl an verkapselten Farbstoffmolekülen mit dem Quaternisierungsgrad zunimmt.Weiterhin können amphiphile µ-Gelpartikel auch als molekulare Nanoreaktoren zur Synthese von Edelmetallkolloiden verwendet werden, die in den Netzwerken topologisch gefangen sind. Hierzu werden zuerst Metallionen im Kugelinneren verkapselt und anschließend reduziert, wobei das Kolloidwachstum durch den wohldefinierten Reaktionsraum gesteuert wird. Neben Gold- und Palladiumkolloiden können auf diese Weise beispielsweise auch Silberkolloide in den Kernen von µ-Netzwerken hergestellt werden.
Resumo:
The g-factor is a constant which connects the magnetic moment $vec{mu}$ of a charged particle, of charge q and mass m, with its angular momentum $vec{J}$. Thus, the magnetic moment can be writen $ vec{mu}_J=g_Jfrac{q}{2m}vec{J}$. The g-factor for a free particle of spin s=1/2 should take the value g=2. But due to quantum electro-dynamical effects it deviates from this value by a small amount, the so called g-factor anomaly $a_e$, which is of the order of $10^{-3}$ for the free electron. This deviation is even bigger if the electron is exposed to high electric fields. Therefore highly charged ions, where electric field strength gets values on the order of $10^{13}-10^{16}$V/cm at the position of the bound electron, are an interesting field of investigations to test QED-calculations. In previous experiments [H"aff00,Ver04] using a single hydrogen-like ion confined in a Penning trap an accuracy of few parts in $10^{-9}$ was obtained. In the present work a new method for precise measurement of magnetic the electronic g-factor of hydrogen-like ions is discussed. Due to the unavoidable magnetic field inhomogeneity in a Penning trap, a very important contribution to the systematic uncertainty in the previous measurements arose from the elevated energy of the ion required for the measurement of its motional frequencies. Then it was necessary to extrapolate the result to vanishing energies. In the new method the energy in the cyclotron degree of freedom is reduced to the minimum attainable energy. This method consist in measuring the reduced cyclotron frequency $nu_{+}$ indirectly by coupling the axial to the reduced cyclotron motion by irradiation of the radio frequency $nu_{coup}=nu_{+}-nu_{ax}+delta$ where $delta$ is, in principle, an unknown detuning that can be obtained from the knowledge of the coupling process. Then the only unknown parameter is the desired value of $nu_+$. As a test, a measurement with, for simplicity, artificially increased axial energy was performed yielding the result $g_{exp}=2.000~047~020~8(24)(44)$. This is in perfect agreement with both the theoretical result $g_{theo}=2.000~047~020~2(6)$ and the previous experimental result $g_{exp1}=2.000~047~025~4(15)(44).$ In the experimental results the second error-bar is due to the uncertainty in the accepted value for the electron's mass. Thus, with the new method a higher accuracy in the g-factor could lead by comparison to the theoretical value to an improved value of the electron's mass. [H"af00] H. H"affner et al., Phys. Rev. Lett. 85 (2000) 5308 [Ver04] J. Verd'u et al., Phys. Rev. Lett. 92 (2004) 093002-1
Resumo:
Im ersten Teil der Arbeit wurde das Bindungsverhalten von Annexin A1 und Annexin A2t an festkörperunterstützte Lipidmembranen aus POPC und POPS untersucht. Für beide Proteine konnte mit Hilfe der Fluoreszenzmikroskopie gezeigt werden, dass irreversible Bindung nur in Anwesenheit von POPS auftritt. Durch rasterkraftmikroskopische Aufnahmen konnte die laterale Organisation der Annexine auf der Lipidmembran dargestellt werden. Beide Proteine lagern sich in Form lateraler Aggregate (zweidimensionale Domänen) auf der Oberfläche an, außerdem ist der Belegungsgrad und die Größe der Domänen von der Membranzusammensetzung und der Calciumkonzentration abhängig. Mit zunehmendem POPS-Gehalt und Calciumkonzentration steigt der Belegungsgrad an und der mittlere Domänenradius wird kleiner. Diese Ergebnisse konnten in Verbindung mit detaillierten Bindungsstudien des Annexins A1 mit der Quarzmikrowaage verwendet werden, um ein Bindungsmodell auf Basis einer heterogenen Oberfläche zu entwickeln. Auf einer POPC-reichen Matrix findet reversible Adsorption statt und auf POPS-reichen Domänen irreversible Adsorption. Durch die Anpassung von dynamischen Monte Carlo-Simulationen basierend auf einer zweidimensionalen zufälligen sequentiellen Adsorption konnten Erkenntnisse über die Membranstruktur und die kinetischen Ratenkonstanten in Abhängigkeit von der Calciumkonzentration und der Inkubationszeit des Proteins gewonnen werden. Die irreversible Bindung ist in allen Calciumkonzentrationsbereichen schneller als die reversible. Außerdem zeigt die irreversible Adsorption eine deutlich stärkere Abhängigkeit von der Calciumkonzentration. Ein kleinerer Belegungsgrad bei niedrigen Ca2+-Gehalten ist hauptsächlich durch die Abnahme der verfügbaren Bindungsplätze auf der Oberfläche zu erklären. Die gute Übereinstimmung der aus den Monte Carlo-Simulationen erhaltenen Domänenstrukturen mit den rasterkraftmikroskopischen Aufnahmen und die Tatsache, dass sich die simulierten Resonanzfrequenzverläufe problemlos an die experimentellen Kurven aus den QCM-Messungen anpassen ließen, zeigt die gute Anwendbarkeit des entwickelten Simulationsprogramms auf die Adsorption von Annexin A1. Die Extraktion der kinetischen Parameter aus dem zweidimensionalen RSA-Modell ist mit Sicherheit einem einfachen Langmuir-Ansatz überlegen. Bei einem Langmuir-Modell erfolgt eine integrale Erfassung einer einzelnen makroskopischen Geschwindigkeitskonstante, während durch das RSA-Modell eine differenzierte Betrachtung des reversiblen und irreversiblen Bindungsprozesses möglich ist. Zusätzlich lassen sich mikroskopische Informationen über die Oberflächenbeschaffenheit gewinnen. Im zweiten Teil der Arbeit wurde das thermotrope Phasenverhalten von festkörperunterstützten Phospholipidbilayern untersucht. Dazu wurden mikrostrukturierte, frei stehende Membranstreifen präpariert und mit Hilfe der bildgebenden Ellipsometrie untersucht. Dadurch konnten die temperaturabhängigen Verläufe der Schichtdicke und der lateralen Membranausdehnung parallel beobachtet werden. Die ermittelten Phasenübergangstemperaturen von DMPC, diC15PC und DPPC lagen 2 - 3 °C oberhalb der Literaturwerte für vesikuläre Systeme. Außerdem wurde eine deutliche Verringerung der Kooperativität der Phasenumwandlung gefunden, was auf einen großen Einfluss des Substrats bei den festkörperunterstützten Lipidmembranen schließen lässt. Zusätzlich wurde ein nicht systematischer Zusammenhang der Ergebnisse von der Oberflächenpräparation gefunden, der es unabdingbar macht, bei Untersuchungen von festkörperunterstützten Substraten einen internen Standard einzuführen. Bei der Analyse des thermotropen Phasenübergangsverhaltens von DMPC/Cholesterol - Gemischen wurde daher die individuelle Adressierbarkeit der strukturierten Lipidmembranen ausgenutzt und ein Lipidstreifen aus reinem DMPC als Standard verwendet. Auf diese Weise konnte gezeigt werden, dass das für Phospholipide typische Phasenübergangsverhalten ab 30 mol% Cholesterol in der Membran nicht mehr vorhanden ist. Dies ist auf die Bildung einer nur durch höhere Sterole induzierten fluiden Phase mit hoch geordneten Acylketten zurückzuführen. Abschließend konnte durch die Zugabe von Ethanol zu einer mikrostrukturierten DMPC-Membran die Bildung eines interdigitierten Bilayers nachgewiesen werden. Die bildgebende Ellipsometrie ist eine sehr gute Methode zur Untersuchung festkörperunterstützter Lipidmembranen, da sie über ein sehr gutes vertikales und ein ausreichendes laterales Auflösungsvermögen besitzt. Sie ist darin zwar einem Rasterkraftmikroskop noch unterlegen, besitzt dafür aber eine einfachere Handhabung beim Umgang mit Flüssigkeiten und in der Temperierung, eine schnellere Bildgebung und ist als optische Methode nicht-invasiv.