895 resultados para Physical Performance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Continuous field mapping has to address two conflicting remote sensing requirements when collecting training data. On one hand, continuous field mapping trains fractional land cover and thus favours mixed training pixels. On the other hand, the spectral signature has to be preferably distinct and thus favours pure training pixels. The aim of this study was to evaluate the sensitivity of training data distribution along fractional and spectral gradients on the resulting mapping performance. We derived four continuous fields (tree, shrubherb, bare, water) from aerial photographs as response variables and processed corresponding spectral signatures from multitemporal Landsat 5 TM data as explanatory variables. Subsequent controlled experiments along fractional cover gradients were then based on generalised linear models. Resulting fractional and spectral distribution differed between single continuous fields, but could be satisfactorily trained and mapped. Pixels with fractional or without respective cover were much more critical than pure full cover pixels. Error distribution of continuous field models was non-uniform with respect to horizontal and vertical spatial distribution of target fields. We conclude that a sampling for continuous field training data should be based on extent and densities in the fractional and spectral, rather than the real spatial space. Consequently, adequate training plots are most probably not systematically distributed in the real spatial space, but cover the gradient and covariate structure of the fractional and spectral space well. (C) 2009 International Society for Photogrammetry and Remote Sensing, Inc. (ISPRS). Published by Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: The aim of this study was to investigate the effect of an acute small ethanol (EtOH) dose (0.5 ml EtOH/kg fat-free mass, combined with carbohydrate) in a drink on endurance performance of trained cyclists. METHODS: Thirteen well-trained male cyclists took part in this study. A 60-min cycling endurance performance test (time trial) was performed in a calorimetric chamber after drinking an EtOH (30 +/- 1.8 ml) or a non-EtOH control (C) drink. RESULTS: Overall, EtOH induced a significant decrease in the average cycling power output (PO) (EtOH: 233 +/- 23 W versus C: 243 +/- 24 W, P < 0.01). The time course of mechanical PO showed an early decrease during the EtOH trial as compared to C (P < 0.01). Due to the lower PO, oxygen consumption, carbon dioxide production and glucose oxidation were significantly lower (P < 0.05) as compared to C. Relative to PO, heart rate response and ratings of perceived exertion (RPE) were increased by EtOH as compared to C (P < 0.05). In contrast, EtOH did not influence gross work efficiency, glycaemia and blood lactate concentration. CONCLUSIONS: These results show that the acute low dose of EtOH decreased endurance performance. An increase of cardio-vascular strain and psychobiological mechanisms may explain this decrease of endurance performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: This study evaluates the effect of front suspension (FS) and dual suspension (DS) mountain-bike on performance and vibrations during off-road uphill riding. METHODS: Thirteen male cyclists (27+/-5 years, 70+/-6 kg, VO(2max)59+/-6 mL.kg(-1).min(-1), mean+/-SD) performed, in a random sequence, at their lactate threshold, an off-road uphill course (1.69 km, 212 m elevation gain) with both type of bicycles. Variable measured: a) VO(2) consumption (K4b2 analyzer, Cosmed), b) power output (SRM) c) gain in altitude and d) 3-D accelerations under the saddle and at the wheel (Physilog, EPFL, Switzerland). Power spectral analy- sis (Fourier) was performed from the vertical acceleration data. RESULTS: Respectively for the FS and DS mountain bike: speed amounted to 7.5+/-0.7 km.h(-1) and 7.4+/-0.8 km.h(-1), (NS), energy expenditure 1.39+/-0.16 kW and 1.38+/-0.18, (NS), gross efficiency 0.161+/-0.013 and 0.159+/-0.013, (NS), peak frequency of vibration under the saddle 4.78+/-2.85 Hz and 2.27+/-0.2 Hz (P<0.01) and median-frequency of vertical displacements of the saddle 9.41+/-1.47 Hz and 5.78+/-2.27 Hz (P<0.01). CONCLUSION: Vibrations at the saddle level of the DS bike are of low frequencies whereas those of the FS bike are mostly of high frequencies. In the DS bike, the torque produced by the cyclist at the pedal level may generate low frequency vibrations. We conclude that the DS bike absorbs more high frequency vibrations, is more comfortable and performs as well as the FS bicycle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Cognitive Performance Scale (CPS) was initially designed to assess cognition in long term care residents. Subsequently, the CPS has also been used among in-home, post-acute, and acute care populations even though CPS' clinimetric performance has not been studied in these settings. This study aimed to determine CPS agreement with the Mini Mental Status Exam (MMSE) and its predictive validity for institutionalization and death in a cohort (N=401) of elderly medical inpatients aged 75 years and over. Medical, physical and mental status were assessed upon admission. The same day, the patient's nurse completed the CPS by interview. Follow-up data were gathered from the central billing system (nursing home stay) and proxies (death). Cognitive impairment was present in 92 (23%) patients according to CPS (score >or= 2). Agreement with MMSE was moderate (kappa 0.52, P<.001). Analysis of discordant results suggested that cognitive impairment was overestimated by the CPS in dependent patients with comorbidities and depressive symptoms, and underestimated in older ones. During follow-up, subjects with abnormal CPS had increased risks of death (adjusted hazard ratio (adjHR) 1.7, 95% CI 1.0-2.8, P=.035) and institutionalization (adjHR 2.7, 95% CI 1.3-5.3, P=.006), independent of demographic, health and functional status. Interestingly, subjects with abnormal CPS were at increased risk of death only if they also had abnormal MMSE. The CPS predicted death and institutionalization during follow-up, but correlated moderately well with the MMSE. Combining CPS and MMSE provided additional predictive information, suggesting that domains other than cognition are assessed by professionals when using the CPS in elderly medical inpatients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of this study were to describe the different modalities of physical activity programs designed for moderate to severe dementia and to identify their impact on functional independence in activities of daily living (ADL). A critical review of randomized controlled trials related to the impact of physical activity programs in moderately to severely demented persons on ADL performance and meta-analysis of the identified studies were performed. Among the 303 identified articles, five responded to the selection criteria. Four out of the five studies demonstrated limited methodological quality. In one high-quality study, physical activity programs significantly delayed deterioration of ADL performance. The program components and ADL assessment tools vary widely across studies. Although the proposed treatments have not proven their efficiency in improving the ADL status of the patients, they were able to limit the decline in ADL functioning. Future research is warranted in order to identify clinically relevant modalities for physical activity programs for people with moderate to severe dementia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use and manufacture of tools have been considered to be cognitively demanding and thus a possible driving factor in the evolution of intelligence. In this study, we tested the hypothesis that enhanced physical cognitive abilities evolved in conjunction with the use of tools, by comparing the performance of naturally tool-using and non-tool-using species in a suite of physical and general learning tasks. We predicted that the habitually tool-using species, New Caledonian crows and Galápagos woodpecker finches, should outperform their non-tool-using relatives, the small tree finches and the carrion crows in a physical problem but not in general learning tasks. We only found a divergence in the predicted direction for corvids. That only one of our comparisons supports the predictions under this hypothesis might be attributable to different complexities of tool-use in the two tool-using species. A critical evaluation is offered of the conceptual and methodological problems inherent in comparative studies on tool-related cognitive abilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This project was undertaken to study the relationships between the performance of locally available asphalts and their physicochemical properties under Iowa conditions with the ultimate objective of development of a locally and performance-based asphalt specification for durable pavements. Physical and physicochemical tests were performed on three sets of asphalt samples including: (a) twelve samples from local asphalt suppliers and their TFOT residues, (b) six core samples of known service records, and (c) a total of 79 asphalts from 10 pavement projects including original, lab aged and recovered asphalts from field mixes, as well as from lab aged mixes. Tests included standard rheological tests, HP-GPC and TMA. Some specific viscoelastic tests (at 5 deg C) were run on b samples and on some a samples. DSC and X-ray diffraction studies were performed on a and b samples. Furthermore, NMR techniques were applied to some a, b and c samples. Efforts were made to identify physicochemical properties which are correlated to physical properties known to affect field performance. The significant physicochemical parameters were used as a basis for an improved performance-based trial specification for Iowa to ensure more durable pavements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Broadcast transmission mode in ad hoc networks is critical to manage multihop routing or providing medium accesscontrol (MAC)-layer fairness. In this paper, it is shown that ahigher capacity to exchange information among neighbors may beobtained through a physical-MAC cross-layer design of the broadcastprotocol exploiting signal separation principles. Coherentdetection and separation of contending nodes is possible throughtraining sequences which are selected at random from a reducedset. Guidelines for the design of this set are derived for a lowimpact on the network performance and the receiver complexity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Our institution (University hospital) is encouraging physical activities for health through various popular sporting events in the city of Lausanne, the biggest of which is a road race of 2, 4, 10 and 20km. Objective To create an efficient and sustainable training program in preparation of the race for a group of motivated hospital employees without any prior experience with structured training and to identifying the benefits and limitations encountered.. Methods Subjects of various fitness levels were recruited by add and agreed to undergo lab and field testing before a 12-week 3 times/week running program, based on maximal aerobic speed (MAS-30/30 sec intervals), running technique exercises and endurance training. The interval session was the only one supervised. Their goal was the 10km (11 subjects) and the 20km (6 subjects). Results A group of 17 subjects (7 male and 10 female), mean age 36.6±7.3 years, VO2max 44.0±5.5 ml/kg/min, filed test interval MAS 15.1±2.4 km/h started the program. 2 were lost because of injury (while skiing). Adherence to interval sessions was excellent, although 3 weekly training sessions proved to be difficult for most of the subjects. Performance in the race was satisfying for all of them, 6/7 subjects having improved their running time from the previous year, the others participated for the first time and 7/8 completed the race satisfyingly, one DNF-ed because of sinusitis. Repeat MAS field test was available for 6 subjects, who improved by 5.9% (p<0.01). Subjectively, all of the participants were very satisfied with improvement, interaction with colleagues from various professions, and with self achievement and confidence. Conclusions Implementation of a structured training program for recreational or non-athletes can be very successful in creating a better self-confidence, a better working environment inside a hospital facility and obviously in improvement of physical fitness and athletic performance. Above all, it can only encourage health institutions to promote the health of their own employees through physical activity, which can allow people to connect through sports. As a result, subjects in this study tend to encourage other employees to be more active and are hungry for more advice and continued offers for physical activities benefiting both them and the institution through better efficiency at work and less absenteeism common to more active people.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El principal objectiu d'aquest treball és implementar i exposar una descripció teòrica per a diferents esquemes de Physical Layer Network Coding. Utilitzant un esquema bàsic com a punt de partida, el projecte presenta la construcció i l'anàlisis de diferents esquemes de comunicació on la complexitat va augmentant a mesura que anem avançant en el projecte. El treball està estructurat en diferents parts: primer, es presenta una introducció a Physical Layer Network Coding i a Lattice Network Codes. A continuació, s'introdueixen les eines matemàtiques necessàries per entendre el CF System. Després, s'analitza i implementa el primer esquema bàsic. A partir del qual, implementem una versió vectorial del CF System i una versió codificada amb un Hamming q-ari. Finalment, s'estudien i implementen diferents estratègies per millorar la matriu de coeficients A.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gas-liquid mass transfer is an important issue in the design and operation of many chemical unit operations. Despite its importance, the evaluation of gas-liquid mass transfer is not straightforward due to the complex nature of the phenomena involved. In this thesis gas-liquid mass transfer was evaluated in three different gas-liquid reactors in a traditional way by measuring the volumetric mass transfer coefficient (kLa). The studied reactors were a bubble column with a T-junction two-phase nozzle for gas dispersion, an industrial scale bubble column reactor for the oxidation of tetrahydroanthrahydroquinone and a concurrent downflow structured bed.The main drawback of this approach is that the obtained correlations give only the average volumetric mass transfer coefficient, which is dependent on average conditions. Moreover, the obtained correlations are valid only for the studied geometry and for the chemical system used in the measurements. In principle, a more fundamental approach is to estimate the interfacial area available for mass transfer from bubble size distributions obtained by solution of population balance equations. This approach has been used in this thesis by developing a population balance model for a bubble column together with phenomenological models for bubble breakage and coalescence. The parameters of the bubble breakage rate and coalescence rate models were estimated by comparing the measured and calculated bubble sizes. The coalescence models always have at least one experimental parameter. This is because the bubble coalescence depends on liquid composition in a way which is difficult to evaluate using known physical properties. The coalescence properties of some model solutions were evaluated by measuring the time that a bubble rests at the free liquid-gas interface before coalescing (the so-calledpersistence time or rest time). The measured persistence times range from 10 msup to 15 s depending on the solution. The coalescence was never found to be instantaneous. The bubble oscillates up and down at the interface at least a coupleof times before coalescence takes place. The measured persistence times were compared to coalescence times obtained by parameter fitting using measured bubble size distributions in a bubble column and a bubble column population balance model. For short persistence times, the persistence and coalescence times are in good agreement. For longer persistence times, however, the persistence times are at least an order of magnitude longer than the corresponding coalescence times from parameter fitting. This discrepancy may be attributed to the uncertainties concerning the estimation of energy dissipation rates, collision rates and mechanisms and contact times of the bubbles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli kehittää kolmannen sukupolven fyysistä protokollakerrosta matkapuhelimen ohjelmistoarkkitehtuurille. Kolmannen sukupolven matkapuhelinjärjestelmät ovat aikaisempia järjestelmiä monimutkaisempia. Ohjelmiston koon ja monimutkaisuuden sekä aikataulujen kiireellisyyden vuoksi on tullut tarve ottaa käyttöön formaaleja menetelmiä ohjelmiston kehitystyöhön. Formaalit kuvauskielet mahdollistavat tarkan, yksiselitteisen ja simuloitavissa olevan järjestelmäkuvauksen muodostamisen. Fyysinen protokollakerros tarjoaa tiedon siirtoa ylemmille protokollakerroksille. Tämän tiedonsiirron hallinta vaatii protokollakerrosten välistä viestinvälitystä. Formaaleja kuvauskieliä käyttämällä voidaan viestinvälityksen toteutusta automatisoida ja siinä tarvittavaa logiikkaa havainnollistaa. Työssä suunniteltiin, toteutettiin ja testattiin ylempien protokollakerrosten kanssa kommunikoivaa osaa fyysisestä protokollakerroksesta. Tuloksena saatiin solunvalintatoiminnallisuuden vaatiman kommunikoinnin ja tilakoneen toteutus ohjelmistoarkkitehtuurissa. Ohjelmistonkehityksen alkuvaiheiden havaittiin olevan fyysisen kerroksen suorituskyvyn kannalta merkittävässä asemassa, koska tällöin viestinvälityksen optimointi on helpointa. Formaalit kuvauskielet eivät ole sellaisenaan täysin soveltuvia tarkoin määritellyn ohjelmistoarkkitehtuurin osien kehitykseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Actualment un típic embedded system (ex. telèfon mòbil) requereix alta qualitat per portar a terme tasques com codificar/descodificar a temps real; han de consumir poc energia per funcionar hores o dies utilitzant bateries lleugeres; han de ser el suficientment flexibles per integrar múltiples aplicacions i estàndards en un sol aparell; han de ser dissenyats i verificats en un període de temps curt tot i l’augment de la complexitat. Els dissenyadors lluiten contra aquestes adversitats, que demanen noves innovacions en arquitectures i metodologies de disseny. Coarse-grained reconfigurable architectures (CGRAs) estan emergent com a candidats potencials per superar totes aquestes dificultats. Diferents tipus d’arquitectures han estat presentades en els últims anys. L’alta granularitat redueix molt el retard, l’àrea, el consum i el temps de configuració comparant amb les FPGAs. D’altra banda, en comparació amb els tradicionals processadors coarse-grained programables, els alts recursos computacionals els permet d’assolir un alt nivell de paral•lelisme i eficiència. No obstant, els CGRAs existents no estant sent aplicats principalment per les grans dificultats en la programació per arquitectures complexes. ADRES és una nova CGRA dissenyada per I’Interuniversity Micro-Electronics Center (IMEC). Combina un processador very-long instruction word (VLIW) i un coarse-grained array per tenir dues opcions diferents en un mateix dispositiu físic. Entre els seus avantatges destaquen l’alta qualitat, poca redundància en les comunicacions i la facilitat de programació. Finalment ADRES és un patró enlloc d’una arquitectura concreta. Amb l’ajuda del compilador DRESC (Dynamically Reconfigurable Embedded System Compile), és possible trobar millors arquitectures o arquitectures específiques segons l’aplicació. Aquest treball presenta la implementació d’un codificador MPEG-4 per l’ADRES. Mostra l’evolució del codi per obtenir una bona implementació per una arquitectura donada. També es presenten les característiques principals d’ADRES i el seu compilador (DRESC). Els objectius són de reduir al màxim el nombre de cicles (temps) per implementar el codificador de MPEG-4 i veure les diferents dificultats de treballar en l’entorn ADRES. Els resultats mostren que els cícles es redueixen en un 67% comparant el codi inicial i final en el mode VLIW i un 84% comparant el codi inicial en VLIW i el final en mode CGA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the development of an alternative acetate bath for the electrochemical codeposition of Ni-Cu-Fe electrodes at low pH that is stable for several weeks and produces electrodes with good performance for chlor-alkali electrolysis. Physical characterization of the electrode surface was made using X ray absorption spectroscopy (XAS), scanning electron microscopy (SEM) and energy dispersive analysis (EDX). The evaluation of the material as electrocatalyst for the hydrogen evolution reaction (her) was carried out in brine solution (160 g L-1 NaCl + 150 g L-1 NaOH) at different temperatures through steady-state polarization curves. The Ni-Cu-Fe electrodes obtained with this bath have shown low overpotentials for the her, around 0.150 V at 353 K, and good stability under continuous long-term operation for 260 hours. One positive aspect of this cathode is that the polarization behavior of the material shows only one Tafel slope over the temperature range of 298 - 353 K.