992 resultados para PULMONARY-ARTERY DIAMETERS
Resumo:
We report a technique to palliate hypoplastic left heart syndrome, with no PDA stenting, but with double polytetrafluoroethylene shunt from pulmonary artery to ascending and descending aorta by combined thoracotomies. A 30-day-old female was operated with this technique. Five months after first operation, the child was submitted to Norwood/Glenn operation. Good hemodinamic recovery and initial clinical evolution was observed. The child was extubated in 8th post operatory day and reentubated in the next day due to pulmonary infection. Despite antibiotic treatment, the child died after systemic infectious complications.
Resumo:
Although infective endocarditis (IE) has been described in reports dating from the Renaissance, the diagnosis still challenges and the outcome often surprises. In the course of time, diagnostic criteria have been updated and validated to reduce misdiagnosis. Some risk factors and epidemiology have shown dynamic changes since degenerative valvular disease became more predominant in developed countries, and the mean age of the affected population increased. Despite streptococci have been being well known as etiologic agents, some groups, although rare, have been increasingly reported (e.g., Streptococcus milleri.) Intracardiac complications of IE are common and have a worse prognosis, frequently requiring surgical treatment. We report a case of a middle-aged diabetic man who presented with prolonged fever, weight loss, and ultimately severe dyspnea. IE was diagnosed based on a new valvular regurgitation murmur, a positive blood culture for Streptococcus anginosus, an echocardiographic finding of an aortic valve vegetation, fever, and pulmonary thromboembolism. Despite an appropriate antibiotic regimen, the patient died. Autopsy findings showed vegetation attached to a bicuspid aortic valve with an associated septal abscess and left ventricle and aortic root fistula connecting with the pulmonary artery. A large thrombus was adherent to the pulmonary artery trunk and a pulmonary septic thromboemboli were also identified.
Resumo:
Introdução: A reposição volêmica em pacientes traumatizados tem sido controvérsa. O A.T.L.S. recomenda a infusão de um grande volume de fluidos na fase inicial de tratamento, enquanto outros autores recomendam a administração somente quando do controle da hemorragia. O acesso venoso femoral é contra indicado em pacientes com trauma abdominal por temor de aumento de hemorragia. A solução hipertônica de NaCl a 7,5% (SH) possui benefícios consideráveis de logística e de recuperação hemodinâmica com pequenos volumes de infusão, semelhante as vantagens das soluções padrões isotônicas na fase pré-hospitalar. Objetivos: Criar um modelo de choque hemorrágico induzido por trauma venoso. Avaliar a hemodinâmica e o volume de hemorragia abdominal nos animais submetidos a choque hemorrágico e tratados com SH via acesso femoral e jugular. Métodos: Em 18 porcos da raça landrace, divididos em 3 grupos de 6 animais (Controle, Jugular e Femoral), foi induzido um choque hipovolêmico não controlado pela ruptura da veia cava caudal. Os animais do grupo controle (GC) foram observados por 40 minutos quanto ao seu padrão hemodinâmico de Pressão de Artéria Pulmonar (PAP), Pressão Artérial Média (PAM), Débito Cardíaco (DC) e Fluxo de Veia Porta (FVP), porém sem reposição volêmica. Os animais dos grupos Femoral (GC) e Jugular (GJ) foram tratados com 4 ml/Kg de solução hipertônica de NaCl a 7,5% (SH) aos 20 minutos de experimento. Ao final do experimento, o volume de hemorragia abdominal foi mensurado.Resultados: O grupo controle (GC) apresentou queda dos valores hemodinâmicos aos 10 minutos e estes permaneceram estáveis até o final do experimento. Os animais dos grupos tratamento (GF e GJ) apresentaram melhora da hemodinâmica aos 30 minutos, sem aumento da hemorragia abdominal. Conclusão: A solução hipertônica de NaCl (SH) permitiu a melhora parcial da hemodinâmica no modelo de choque hipovolêmico, sem aumento da hemorragia, independentemente do acesso utilizada para a infusão.
Resumo:
In questo lavoro ci siamo posti come obiettivo lo studio della disfunzione atrio-ventricolare mediante tecniche ecocardiografiche avanzate (come il Tissue Doppler Imaging - TDI) in cani affetti da malattia mitralica cronica (MVD). Una prima parte è volta alla valutazione della funzionalità diastolica del ventricolo destro. Ci siamo proposti di analizzare la funzione del ventricolo destro in cani affetti da malattia del cuore sinistro per comprendere se quest’ultima possa condizionare direttamente la performance del settore cardiaco controlaterale. I risultati più importanti che abbiamo riscontrato sono: l’assenza di differenze significative nella disfunzione sisto-diastolica del ventricolo destro in cani con MVD a diverso stadio; la diretta correlazione tra le variabili TDI di funzionalità del ventricolo destro con il grado di disfunzione del ventricolo sinistro, come indicatori di interdipendenza ventricolare; ed infine il riscontro di una maggior tendenza ad alterazioni diastoliche del ventricolo sinistro in cani con ipertensione polmonare. A quest’ultimo proposito, per quanto riguarda le variabili TDI, il rapporto E/e’ dell’anulus mitralico laterale e settale è risultato avere una differenza significativa tra i cani con ipertensione polmonare e quelli privi di ipertensione polmonare (P<0,01). Nel secondo studio abbiamo applicato il TDI per l’analisi della funzione sisto-diastolica dell’atrio sinistro. Il lavoro è stato articolato in una parte di validazione della metodica su cani normali ed una su animali affetti da MDV. I risultati ottenuti mostrano che la valutazione ecocardiografica delle proprietà di deformazione dell’atrio sinistro basata sul TDI è attuabile e riproducibile nel cane. Abbiamo fornito dei valori di normalità per questa specie e confrontato questi dati con quelli ricavati in cani portatori di MVD. Le differenza tra le varie classi di malattia, nei diversi gradi di dilatazione atriale, sono risultate limitate, ma abbiamo individuato delle correlazioni tra i parametri TDI ed alcune variabili di funzionalità atriale.
Resumo:
L'intervento di connessione cavo-polmonare totale (TCPC) nei pazienti portatori di cuore univentricolare, a causa della particolare condizione emodinamica, determina un risentimento a carico di numerosi parenchimi. Scopo della ricerca è di valutare l'entità di questo danno ad un follow-up medio-lungo. Sono stati arruolati 115 pazienti, sottoposti ad intervento presso i centri di Cardiochirurgia Pediatrica di Bologna (52 pz) e Torino (63 pz). Il follow-up medio è stato di 125±2 mesi. I pazienti sono stati sottoposti ad indagine emodinamica (88 pz), test cardiopolmonare (75 pz) e Fibroscan ed ecografia epatica (47 pz). La pressione polmonare media è stata di 11.5±2.6mmHg, ed in 12 pazienti i valori di pressione polmonare erano superiori a 15mmHg. La pressione atriale media era di 6.7±2.3mmHg ed il calcolo delle resistenze vascolari polmonari indicizzate (RVP) era in media di 2±0.99 UW/m2. In 29 pazienti le RVP erano superiori a 2 UW/m2. La VO2 max in media era pari a 28±31 ml/Kg/min, 58±15 % del valore teorico. La frequenza cardiaca massima all'apice dello sforzo era di 151±22 bpm, pari al 74±17% del valore teorico. Il Fibroscan ha fornito un valore medio di 17.01 kPa (8-34.3kPa). Cinque pazienti erano in classe F2, 9 pazienti in classe F3 e 33 pazienti risultavano in classe F4. Nei pazienti con follow-up maggiore di 10 anni il valore di stiffness epatica (19.6±5.2kPa) è risultato significativamente maggiore a quello dei pazienti con follow-up minore di 10 anni (15.1±5.8kPa, p<0.01). La frequenza cardiaca massima raggiunta durante lo sforzo del test cardiopolmonare è risultata significativamente correlata alla morfologia del ventricolo unico, risultando del 67.8±14.4% del valore teorico nei pazienti portatori di ventricolo destro contro il 79.6±8.7% dei portatori di ventricolo sinistro (p=0.006). L'intervento di TCPC determina un risentimento a carico di numerosi parenchimi proporzionale alla lunghezza del follow-up, e necessita pertanto un costante monitoraggio clinico-strumentale multidisciplinare.
Resumo:
La BCPA e’ ormai utilizzata routinariamente come stadio intermedio della palliazione di Fontan nel trattamento dei cuori funzionalmente univentricolari e si conferma intervento a ridotta mortalità e morbilità. La crescita delle arterie polmonari dopo BCPA è abbastanza variabile ed imprevedibile, le dimensioni indicizzate dei rami principali sembrano tendenzialmente ridotte, tranne quelle dell’arteria lobare inferiore destra, la quale beneficerebbe del flusso preferenziale della BCPA. Proprio i pazienti con arterie polmonari più piccole mostrerebbero un maggior incremento di dimensioni delle stesse dopo BPCA. Il ruolo ed i vantaggi del flusso accessorio nella BCPA sono ancora da definire; tuttavia sembrerebbe offrire vantaggi in termini di crescita delle arterie polmonari, soprattutto il ramo lobare sinistro, e di miglior outcome dopo TCPC.
Resumo:
BACKGROUND: Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. MATERIALS AND METHODS: Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after preparation, baseline measurements were taken. At first, 5% of total blood volume was withdrawn, followed by another 5% increment, and then in 10% increments until death. RESULTS: After withdrawal of 5% of estimated blood volume, dPP increased from 6.1% +/- 3.0% to 20.8% +/- 2.7% (P < 0.01). Mean arterial pressure (MAP), mean pulmonary artery pressure (PAP) and pulmonary artery occlusion pressure (PAOP) decreased with a blood loss of 10% (P < 0.01). Cardiac output (CO) changed after a blood loss of 20% (P < 0.05). Tissue oxygen tension in central organs, and blood flow in the jejunal muscularis decreased (P < 0.05) after a blood loss of 20%. Tissue oxygen tension in the skin, and jejunal mucosa blood flow decreased (P < 0.05) after a blood loss of 40% and 50%, respectively. CONCLUSIONS: In this hemorrhagic pig model systemic hemodynamic parameters were more sensitive to detect acute hypovolemia than tissue oxygen tension measurements or jejunal LDF measurements. Acute blood loss was detected first by dPP.
Resumo:
Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.
Resumo:
ABSTRACT : INTRODUCTION : V2-receptor (V2R) stimulation potentially aggravates sepsis-induced vasodilation, fluid accumulation and microvascular thrombosis. Therefore, the present study was performed to determine the effects of a first-line therapy with the selective V2R-antagonist (Propionyl1-D-Tyr(Et)2-Val4-Abu6-Arg8,9)-Vasopressin on cardiopulmonary hemodynamics and organ function vs. the mixed V1aR/V2R-agonist arginine vasopressin (AVP) or placebo in an established ovine model of septic shock. METHODS : After the onset of septic shock, chronically instrumented sheep were randomly assigned to receive first-line treatment with the selective V2R-antagonist (1 g/kg per hour), AVP (0.05 g/kg per hour), or normal saline (placebo, each n = 7). In all groups, open-label norepinephrine was additionally titrated up to 1 g/kg per minute to maintain mean arterial pressure at 70 ± 5 mmHg, if necessary. RESULTS : Compared to AVP- and placebo-treated animals, the selective V2R-antagonist stabilized cardiopulmonary hemodynamics (mean arterial and pulmonary artery pressure, cardiac index) as effectively and increased intravascular volume as suggested by higher cardiac filling pressures. Furthermore, left ventricular stroke work index was higher in the V2R-antagonist group than in the AVP group. Notably, metabolic (pH, base excess, lactate concentrations), liver (transaminases, bilirubin) and renal (creatinine and blood urea nitrogen plasma levels, urinary output, creatinine clearance) dysfunctions were attenuated by the V2R-antagonist when compared with AVP and placebo. The onset of septic shock was associated with an increase in AVP plasma levels as compared to baseline in all groups. Whereas AVP plasma levels remained constant in the placebo group, infusion of AVP increased AVP plasma levels up to 149 ± 21 pg/mL. Notably, treatment with the selective V2R-antagonist led to a significant decrease of AVP plasma levels as compared to shock time (P < 0.001) and to both other groups (P < 0.05 vs. placebo; P < 0.001 vs. AVP). Immunohistochemical analyses of lung tissue revealed higher hemeoxygenase-1 (vs. placebo) and lower 3-nitrotyrosine concentrations (vs. AVP) in the V2R-antagonist group. In addition, the selective V2R-antagonist slightly prolonged survival (14 ± 1 hour) when compared to AVP (11 ± 1 hour, P = 0.007) and placebo (11 ± 1 hour, P = 0.025). CONCLUSIONS : Selective V2R-antagonism may represent an innovative therapeutic approach to attenuate multiple organ dysfunction in early septic shock.
Resumo:
Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.
Resumo:
We hypothesized that fluid administration may increase regional splanchnic perfusion after abdominal surgery-even in the absence of a cardiac stroke volume (SV) increase and independent of accompanying endotoxemia. Sixteen anesthetized pigs underwent abdominal surgery with flow probe fitting around splanchnic vessels and carotid arteries. They were randomized to continuous placebo or endotoxin infusion, and when clinical signs of hypovolemia (mean arterial pressure, <60 mmHg; heart rate, >100 beats · min(-1); urine production, <0.5 mL · kg(-1) · h(-1); arterial lactate concentration, >2 mmol · L(-1)) and/or low pulmonary artery occlusion pressure (target 5-8 mmHg) were present, they received repeated boli of colloids (50 mL) as long as SV increased 10% or greater. Stroke volume and regional blood flows were monitored 2 min before and 30 min after fluid challenges. Of 132 fluid challenges, 45 (34%) resulted in an SV increase of 10% or greater, whereas 82 (62%) resulted in an increase of 10% or greater in one or more of the abdominal flows (P < 0.001). During blood flow redistribution, celiac trunk (19% of all measurements) and hepatic artery flow (15%) most often decreased, whereas portal vein (10%) and carotid artery (7%) flow decreased less frequently (P = 0.015, between regions). In control animals, celiac trunk (30% vs. 9%, P = 0.004) and hepatic artery (25% vs. 11%, P = 0.040) flow decreased more often than in endotoxin-infused pigs. Accordingly, blood flow redistribution is a common phenomenon in the postoperative period and is only marginally influenced by endotoxemia. Fluid management based on SV changes may not be useful for improving regional abdominal perfusion.
Resumo:
Purpose:To determine the potential of minimally invasive postmortem computed tomographic (CT) angiography combined with image-guided tissue biopsy of the myocardium and lungs in decedents who were thought to have died of acute chest disease and to compare this method with conventional autopsy as the reference standard.Materials and Methods:The responsible justice department and ethics committee approved this study. Twenty corpses (four female corpses and 16 male corpses; age range, 15-80 years), all of whom were reported to have had antemortem acute chest pain, were imaged with postmortem whole-body CT angiography and underwent standardized image-guided biopsy. The standard included three biopsies of the myocardium and a single biopsy of bilateral central lung tissue. Additional biopsies of pulmonary clots for differentiation of pulmonary embolism and postmortem organized thrombus were performed after initial analysis of the cross-sectional images. Subsequent traditional autopsy with sampling of histologic specimens was performed in all cases. Thereafter, conventional histologic and autopsy reports were compared with postmortem CT angiography and CT-guided biopsy findings. A Cohen k coefficient analysis was performed to explore the effect of the clustered nature of the data.Results:In 19 of the 20 cadavers, findings at postmortem CT angiography in combination with CT-guided biopsy validated the cause of death found at traditional autopsy. In one cadaver, early myocardial infarction of the papillary muscles had been missed. The Cohen κ coefficient was 0.94. There were four instances of pulmonary embolism, three aortic dissections (Stanford type A), three myocardial infarctions, three instances of fresh coronary thrombosis, three cases of obstructive coronary artery disease, one ruptured ulcer of the ascending aorta, one ruptured aneurysm of the right subclavian artery, one case of myocarditis, and one pulmonary malignancy with pulmonary artery erosion. In seven of 20 cadavers, CT-guided biopsy provided additional histopathologic information that substantiated the final diagnosis of the cause of death.Conclusion:Postmortem CT angiography combined with image-guided biopsy, because of their minimally invasive nature, have a potential role in the detection of the cause of death after acute chest pain.© RSNA, 2012.
Resumo:
In idiopathic portal hypertension (IPH) typical vascular lesions are present in the branches of the portal vein or in the perisinusoidal area of the liver. Similar histological alterations have been reported in the pulmonary vasculature of patients with idiopathic pulmonary artery hypertension (IPAH). As IPAH is associated with mutations of the bone morphogenetic protein receptor 2 (BMPR2) gene, the aim of this study was to investigate whether this association might also be found in patients with IPH. Twenty-three samples belonging to 21 unrelated caucasian patients with IPH followed in the hepatic haemodynamic laboratory of the Hospital Clinic in Barcelona were included in the study. All patients were studied for the entire open reading frame and splice site of the BMPR2 gene by direct sequencing and multiple ligation probe amplification (MLPA) in order to detect large deletions/duplications. None of the 23 patients had pulmonary artery hypertension. Four patients presented one single nucleotide polymorphism (SNP) in intron 5, four patients had a SNP in exon 12 and a SNP in exon 1 was found in two cases. Two patients had both intron 5 and exon 12 polymorphisms. All SNPs were previously described. Except for these three SNPs, neither mutations nor rearrangements have been identified in the BMPR2 gene in this population. We did not detect mutations or rearrangements in the coding region of the BMPR2 gene in our patients with IPH. These findings suggest that, in contrast to IPAH, mutations in BMPR2 are not involved in the pathogenesis of IPH.
Resumo:
Recent outstanding clinical advances with new mechanical circulatory systems (MCS) have led to additional strategies in the treatment of end stage heart failure (HF). Heart transplantation (HTx) can be postponed and for certain patients even replaced by smaller implantable left ventricular assist devices (LVAD). Mechanical support of the failing left ventricle enables appropriate hemodynamic stabilisation and recovery of secondary organ failure, often seen in these severely ill patients. These new devices may be of great help to bridge patients until a suitable cardiac allograft is available but are also discussed as definitive treatment for patients who do not qualify for transplantation. Main indications for LVAD implantation are bridge to recovery, bridge to transplantation or destination therapy. LVAD may be an important tool for patients with an expected prolonged period on the waiting list, for instance those with blood group 0 or B, with a body weight over 90 kg and those with potentially reversible secondary organ failure and pulmonary artery hypertension. However, LVAD implantation means an additional heart operation with inherent peri-operative risks and complications during the waiting period. Finally, cardiac transplantation in patients with prior implantation of a LVAD represents a surgical challenge. This review summarises the current knowledge about LVAD and continuous flow devices especially since the latter have been increasingly used worldwide in the most recent years. The review is also based on the institutional experience at Berne University Hospital between 2000 and 2012. Apart from short-term devices (Impella, Cardiac Assist, Deltastream and ECMO) which were used in approximately 150 cases, 85 pulsatile long-term LVAD, RVAD or bi-VAD and 44 non-pulsatile LVAD (mainly HeartMateII and HeartWare) were implanted. After an initial learning curve, one-year mortality dropped to 10.4% in the last 58 patients.
Resumo:
We assessed changes in intravascular volume monitored by difference in pulse pressure (dPP%) after stepwise hemorrhage in an experimental pig model. Six pigs (23-25 kg) were anesthetized (isoflurane 1.5 vol%) and mechanically ventilated to keep end-tidal CO2 (etCO2) at 35 mmHg. A PA-catheter and an arterial catheter were placed via femoral access. During and after surgery, animals received lactated Ringer's solution as long as they were considered volume responders (dPP>13%). Then animals were allowed to stabilize from the induction of anesthesia and insertion of catheters for 30 min. After stabilization, baseline measurements were taken. Five percent of blood volume was withdrawn, followed by another 5%, and then in 10%-increments until death from exsanguination occurred. After withdrawal of 5% of blood volume, all pigs were considered volume responders (dPP>13%); dPP rose significantly from 6.1+/-3.3% to 19.4+/-4.2%. The regression analysis of stepwise hemorrhage revealed a linear relation between blood loss (hemorrhage in %) and dPP (y=0.99*x+14; R2=0.7764; P<.0001). In addition, dPP was the only parameter that changed significantly between baseline and a blood loss of 5% (P<0.01), whereas cardiac output, stroke volume, heart rate, MAP, central venous pressure, pulmonary artery occlusion pressure, and systemic vascular resistance, respectively, remained unchanged. We conclude that in an experimental hypovolemic pig model, dPP correlates well with blood loss.