932 resultados para Ophthalmic Optics and Devices


Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been observed experimentally [H.R. Xia, C.Y. Ye, and S.Y. Zhu, Phys. Rev. Lett. 77, 1032 (1996)] that quantum interference between two molecular transitions can lead to a suppression or enhancement of spontaneous emission. This is manifest in the fluorescent intensity as a function of the detuning of the driving field from the two-photon resonance condition. Here we present a theory that explains the observed variation of the number of peaks with the mutual polarization of the molecular transition dipole moments. Using master equation techniques we calculate analytically as well as numerically the steady-state fluorescence, and find that the number of peaks depends on the excitation process. If the molecule is driven to the upper levels by a two-photon process, the fluorescent intensity consists of two peaks regardless of the mutual polarization of the transition dipole moments. Lf the excitation process is composed of both a two-step, one-photon process and a one-step, two-photon process, then there are two peaks on transitions with parallel dipole moments and three peaks on transitions with antiparallel dipole moments. This latter case is in excellent agreement with the experiment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We analyze the fidelity of teleportation protocols, as a function of resource entanglement, for three kinds of two-mode oscillator states: states with fixed total photon number, number states entangled at a beam splitter, and the two-mode squeezed vacuum state. We define corresponding teleportation protocols for each case including phase noise to model degraded entanglement of each resource.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The response of a two-level atom in a strong polychromatic field composed of a large number of equidistant frequency components is investigated. We calculate numerically, as well as analytically,:the stationary population inversion and show that the saturation of the atomic transition strongly depends on whether or not there is a central (resonant) frequency component in the driving field. We find that, in the presence of the central component, the atom can remain in the ground state even for a strong Rabi frequency of the driving field. In addition, we find that the inversion is sensitive to the relative phase between the frequency components. When the central component is suppressed, the atomic transition saturates with the Rabi frequency independent of the relative phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate the utility of nonclassical states of simple harmonic oscillators, particularly a superposition of coherent states, for sensitive force detection. We find that like squeezed states, a superposition of coherent states allows displacement measurements at the Heisenberg limit. Entangling many superpositions of coherent states offers a significant advantage over a single-mode superposition state with the same mean photon number.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We are currently in the midst of a second quantum revolution. The first quantum revolution gave us new rules that govern physical reality. The second quantum revolution will take these rules and use them to develop new technologies. In this review we discuss the principles upon which quantum technology is based and the tools required to develop it. We discuss a number of examples of research programs that could deliver quantum technologies in coming decades including: quantum information technology, quantum electromechanical systems, coherent quantum electronics, quantum optics and coherent matter technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate complete characterization of a two-qubit entangling process-a linear optics controlled-NOT gate operating with coincident detection-by quantum process tomography. We use a maximum-likelihood estimation to convert the experimental data into a physical process matrix. The process matrix allows an accurate prediction of the operation of the gate for arbitrary input states and a calculation of gate performance measures such as the average gate fidelity, average purity, and entangling capability of our gate, which are 0.90, 0.83, and 0.73, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We generalize a proposal for detecting single-phonon transitions in a single nanoelectromechanical system (NEMS) to include the intrinsic anharmonicity of each mechanical oscillator. In this scheme two NEMS oscillators are coupled via a term quadratic in the amplitude of oscillation for each oscillator. One NEMS oscillator is driven and strongly damped and becomes a transducer for phonon number in the other measured oscillator. We derive the conditions for this measurement scheme to be quantum limited and find a condition on the size of the anharmonicity. We also derive the relation between the phase diffusion back-action noise due to number measurement and the localization time for the measured system to enter a phonon-number eigenstate. We relate both these time scales to the strength of the measured signal, which is an induced current proportional to the position of the read-out oscillator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we describe the process of teleportation between Alice in an inertial frame, and Rob who is in uniform acceleration with respect to Alice. The fidelity of the teleportation is reduced due to Davies-Unruh radiation in Rob's frame. In so far as teleportation is a measure of entanglement, our results suggest that quantum entanglement is degraded in non-inertial frames. We discuss this reduction in fidelity for both bosonic and fermionic resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The objective of this pilot study was to evaluate the efficacy and safety of 5% imiquimod cream in the treatment of periocular basal cell carcinoma (BCC) through the analysis of a case series. Methods: Eight subjects with primary nodular BCC of the eyelid were recruited. Treatment lasted 10 to 16 weeks. The average follow-up time was 11.7 months. Results: Of a total of 10 lesions, 80% resolved clinically and histologically and have remained asymptomatic since. Conclusion: Imiquimod cream 5% was shown to be an attractive alternative to surgical treatment of periocular BCC. Future studies with larger samples and longer follow-up periods are expected to provide more accurate information on the efficacy and safety of the drug.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Essential blepharospasm is an idiopathic disorder that consists of spontaneous, spasmodic, and involuntary eyelid closure in the absence of ocular disease. Some patients develop an inability to open their eyelids in the absence of orbicularis spasms. These patients have essential blepharospasm combined with apraxia of eyelid opening. Botulinum toxin injections are the treatment of choice for blepharospasm but results may be insufficient, especially in cases associated with apraxia. Apraxia can be treated surgically by levator aponeurosis advancement, frontalis suspension, and upper myectomy. The authors report the first browlift using polypropylene suture to manage eyelid apraxia associated with blepharospasm as an alternative and minimally invasive procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the use of orbital polyacrylamide gel injection for the correction of anophthalmic enophthalmos. Methods: Noncontrolled clinical trial of 21 patients (14 with ocular implants, 5 with phthisis bulbi, and 2 with dermis-fat graft). Orbital CT was performed to estimate the volume of polyacrylamide gel needed to restore orbital volume. Polyacrylamide gel was injected using a 22-gauge (30 x 0.7 min) needle transcutaneously inserted in the lateral third of the lower eyelid, directed to the orbital muscle cone. A second injection was administered 15 days later. if necessary. CT was repeated 30 days after the last procedure. Exophthalmometry was performed before Bind 90 days after file procedure. Results: The mean total volume injected per orbit was 2.4 +/- 0.7 ml (range 1-3.5 ml). The volume of the enophthalmic orbit increased front 26.9 +/- 5.0 ml to 29.3 +/- 4.9 ml (p < 0.001). The mean difference in exophthalmometry readings was 3.3 +/- 1.6 mm (range, 1.5-8.0 mm) before the procedure and 1.0 +/- 0.9 mm (range, 0.0-3.0 mm) after 3 months (p < 0.001). Adjustment of the ocular prosthesis or fabrication of a new one was necessary in 11 patients (52.4%), and the mean volume of the ocular prosthesis was reduced front 2.0 +/- 0.6 ml to 1.6 +/- 0.6 ml (p = 0.003). All patients were satisfied with the aesthetic results. No serious adverse events were observed. The initial results were maintained 1 year after the procedure. Conclusions: Polyacrylamide gel injection in the orbital space effectively reduces enophthalmos in ocular prosthesis wearers.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare the level of sedation of oral administration of diazepam or midazolam associated or not with clonidine and their effects on upper eyelid margin position, heart rate, arterial pressure, and oxygen saturation. Methods: Seventy consecutive healthy patients American Society of Anesthesiologists (ASA) grade I-II scheduled for lower eyelid blepharoplasty were randomized into 4 groups according to the oral sedative agent used (group 1, diazepam 10 mg; group 2, diazepam 10 mg plus clonidine 0.15 mg; group 3, midazolam 15 mg; group 4, midazolam plus clonidine 0.15 mg). For all patients, the midpupil-to-upper eyelid margin distance, the heart rate, systolic and diastolic blood pressure, and oxygen saturation were recorded before and 1 hour after the administration of oral medication. The level of sedation at the time of surgery was measured with the Michigan University scale. Results: The depth of sedation was significantly more pronounced with midazolam (median score = 2) than with diazepam (median score = 1). Clonidine slightly increased the level of sedation of both diazepam and midazolam. The diastolic arterial blood pressure drop with midazolam associated or not with clonidine was significantly greater than with diazepam. The mean upper eyelid margin position shift (-1.42 mm) verified when clonidine was associated with midazolam was also significantly greater than with diazepam. Discussion: Oral sedation with diazepam or midazolam associated or not with clonidine is safe for ASA grade I-II patients. The systemic effects of diazepam and midazolam were small and very similar. The sedation induced by midazolam was clearly greater than that induced by diazepam. However, this higher level of sedation was accompanied by a more important shift in upper eyelid margin position.