914 resultados para Mitral Valve


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy. BACKGROUND Since its commercialization in 2007, the number of TAVR procedures has grown exponentially. METHODS The adoption of TAVR was investigated in 11 European countries: Germany, France, Italy, United Kingdom, Spain, the Netherlands, Switzerland, Belgium, Portugal, Denmark, and Ireland. Data were collected from 2 sources: 1) lead physicians submitted nation-specific registry data; and 2) an implantation-based TAVR market tracker. Economic indexes such as healthcare expenditure per capita, sources of healthcare funding, and reimbursement strategies were correlated to TAVR use. Furthermore, we assessed the extent to which TAVR has penetrated its potential patient population. RESULTS Between 2007 and 2011, 34,317 patients underwent TAVR. Considerable variation in TAVR use existed across nations. In 2011, the number of TAVR implants per million individuals ranged from 6.1 in Portugal to 88.7 in Germany (33 ± 25). The annual number of TAVR implants performed per center across nations also varied widely (range 10 to 89). The weighted average TAVR penetration rate was low: 17.9%. Significant correlation was found between TAVR use and healthcare spending per capita (r = 0.80; p = 0.005). TAVR-specific reimbursement systems were associated with higher TAVR use than restricted systems (698 ± 232 vs. 213 ± 112 implants/million individuals ≥ 75 years; p = 0.002). CONCLUSIONS The authors' findings indicate that TAVR is underutilized in high and prohibitive surgical risk patients with severe aortic stenosis. National economic indexes and reimbursement strategies are closely linked with TAVR use and help explain the inequitable adoption of this therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) constitutes a relatively new treatment option for the patients with severe symptomatic aortic stenosis. Evidence from registries and randomized control trials has underscored the value of this treatment in inoperable and high risk populations, while new developments in valve technology and TAVR enabling devices have reduced the risk of complications, simplified the procedure, and broadened the applications of this therapy. The initial promising clinical results and the potential of an effective less invasive treatment of aortic stenosis has not only created high expectations but also the need to address the pitfalls of TAVR technology. The evolving knowledge concerning the groups of patients who would benefit from this treatment, the limited long term follow-up data, the concerns about devices' long term durability, and the severity of complications remain important caveats which restrict the widespread clinical adoption of TAVR. The aim of this review article is to present the recent advances, highlight the limitations of TAVR technology, and discuss the future perspectives in this rapidly evolving field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peri-procedural bleeding complications are feared adverse events in patients undergoing transcatheter aortic valve implantation (TAVI). Little is known about the implications of peri-procedural bleeding on clinical outcome. In a prospective single-center registry of consecutive patients undergoing TAVI, we investigated incidence, predictors and clinical consequences of life-threatening and major bleeding as defined by the Valve Academic Research Consortium. Among 389 consecutive patients undergoing TAVI by a transfemoral (79.2%), transapical (19.6%) or trans-subclavian (1.3%) approach between July 2007 and October 2011, life-threatening or major peri-procedural bleeding events occurred in 64 (16.4%) and 125 patients (32.1%), respectively. Patients with peri-procedural bleeding events had a higher logistic EuroSCORE, more advanced renal disease, and were more symptomatic as assessed by New York Heart Association functional class at baseline as compared to patients with no bleeding. Life-threatening bleeding was associated with a higher all-cause (17.2 vs. 5.6 vs. 3.0%, p < 0.001) and cardiovascular mortality (10.9 vs. 5.6 vs. 2.5%, p = 0.02) at 30 days compared to patients with major bleeding or no bleeding. Multivariate analysis identified transapical access (OR 2.6, 95% CI 1.4-4.8; p = 0.002), glomerular filtration rate <30 ml/min (OR 2.3, 95% CI 1.1-4.7, p = 0.031), and diabetes (OR 1.8, 95% CI 1.001-3.2, p = 0.049) as independent predictors of life-threatening, peri-procedural bleeding. Life-threatening bleeding complications in patients undergoing TAVI are associated with increased mortality. Renal impairment, diabetes, and transapical approach were identified as independent risk factors for life-threatening bleeding events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate the accuracy and reproducibility of aortic annulus sizing using a multislice computed tomography (MSCT) based aortic root reconstruction tool compared with conventional imaging among patients evaluated for transcatheter aortic valve replacement (TAVR). Methods and results: Patients referred for TAVR underwent standard preprocedural assessment of aortic annulus parameters using MSCT, angiography and transoesophageal echocardiography (TEE). Three-dimensional (3-D) reconstruction of MSCT images of the aortic root was performed using 3mensio (3mensio Medical Imaging BV, Bilthoven, The Netherlands), allowing for semi-automated delineation of the annular plane and assessment of annulus perimeter, area, maximum, minimum and virtual diameters derived from area and perimeter (aVD and pVD). A total of 177 patients were enrolled. We observed a good inter-observer variability of 3-D reconstruction assessments with concordance coefficients for agreement of 0.91 (95% CI: 0.87-0.93) and 0.91 (0.88-0.94) for annulus perimeter and area assessments, respectively. 3-D derived pVD and aVD correlated very closely with a concordance coefficient of 0.97 (0.96-0.98) with a mean difference of 0.5±0.3 mm (pVD-aVD). 3-D derived pVD showed the best, but moderate concordance with diameters obtained from coronal MSCT (0.67, 0.56-0.75; 0.3±1.8 mm), and the lowest concordance with diameters obtained from TEE (0.42, 0.31-0.52; 1.9±1.9 mm). Conclusions: MSCT-based 3-D reconstruction of the aortic annulus using the 3mensio software enables accurate and reproducible assessment of aortic annulus dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS Our aim was to evaluate the invasive haemodynamic indices of high-risk symptomatic patients presenting with 'paradoxical' low-flow, low-gradient, severe aortic stenosis (AS) (PLF-LG) and low-flow, low-gradient severe AS (LEF-LG) and to compare clinical outcomes following transcatheter aortic valve implantation (TAVI) among these challenging AS subgroups. METHODS AND RESULTS Of 534 symptomatic patients undergoing TAVI, 385 had a full pre-procedural right and left heart catheterization. A total of 208 patients had high-gradient severe AS [HGAS; mean gradient (MG) ≥40 mmHg], 85 had PLF-LG [MG ≤ 40 mmHg, indexed aortic valve area [iAVA] ≤0.6 cm(2) m(-2), stroke volume index ≤35 mL/m(2), ejection fraction (EF) ≥50%], and 61 had LEF-LG (MG ≤ 40 mmHg, iAVA ≤0.6 cm(2) m(-2), EF ≤40%). Compared with HGAS, PLF-LG and LEF-LG had higher systemic vascular resistances (HGAS: 1912 ± 654 vs. PLF-LG 2006 ± 586 vs. LEF-LG 2216 ± 765 dyne s m(-5), P = 0.007) but lower valvulo-arterial impedances (HGAS: 7.8 ± 2.7 vs. PLF-LG 6.9 ± 1.9 vs. LEF-LG 7.7 ± 2.5 mmHg mL(-1) m(-2), P = 0.027). At 30 days, no differences in cardiac death (6.5 vs. 4.9 vs. 6.6%, P = 0.90) or death (8.4 vs. 6.1 vs. 6.6%, P = 0.88) were observed among HGAS, PLF-LG, and LEF-LG groups, respectively. At 1 year, New York Heart Association functional improvement occurred in most surviving patients (HGAS: 69.2% vs. PLF-LG 71.7% vs. LEF-LG 89.3%, P = 0.09) and no significant differences in overall mortality were observed (17.6 vs. 20.5 vs. 24.5%, P = 0.67). Compared with HGAS, LEF-LG had a higher 1 year cardiac mortality (adjusted hazard ratio 2.45, 95% confidence interval 1.04-5.75, P = 0.04). CONCLUSION TAVI in PLF-LG or LEF-LG patients is associated with overall mortality rates comparable with HGAS patients and all groups profit symptomatically to a similar extent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a disruptive technology as it satisfies a previously unmet need which is associated with a profound therapeutic benefit. In randomized clinical trials, TAVI has been shown to improve survival compared with medical treatment among patients considered not suitable candidates for surgical aortic valve replacement (SAVR), and to provide similar outcomes as SAVR in selected high-risk patients. Currently, TAVI is limited to selected elderly patients with symptomatic severe aortic stenosis. As this patient population frequently suffers from comorbid conditions, which may influence outcomes, the selection of patients to undergo TAVI underlies a complex decision process. Several clinical risk score algorithms are routinely used, although they fall short to fully appreciate the true risk among patients currently referred for TAVI. Beyond traditional risk scores, the clinical assessment by an interdisciplinary Heart Team as well as detailed imaging of the aortic valve, aortic root, descending and abdominal aorta as well as peripheral vasculature are important prerequisites to plan a successful procedure. This review will familiarize the reader with the concepts of the interdisciplinary Heart team, risk scores as well as the most important imaging algorithms suited to select appropriate TAVI patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a widely accepted alternative to surgical aortic valve replacement (SAVR) among non-operable patients or selected high-risk patients with degenerative, severe aortic stenosis. TAVI is considered less invasive when compared with SAVR; however, there remain significant differences between different TAVI access routes. The transfemoral approach is considered the least invasive access route, and can be performed as a fully percutaneous procedure in a spontaneously breathing patient under local anaesthesia and mild sedation only. Moreover, transfemoral TAVI patients are typically transferred to coronary care rather than to an intensive care unit after the procedure, and benefit from early ambulation and a reduction in overall length of hospital stay. Considering these patient-specific and health-economic advantages, several TAVI centres follow the least invasive strategy for their patients and have implemented the transfemoral access route as the default access in their institutions. This article provides an overview on the prerequisites for a successful transfemoral TAVI procedure, describes the procedural advantages compared to alternative access routes, and highlights differences in clinical outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of an 84-year-old male presenting with syncope and dynamic ST-T wave changes due to decompensated severe valvular aortic stenosis undergoing successful emergency transcatheter aortic valve implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Heart valve diseases are common with an estimated prevalence of 2.5% in the Western world. The number is rising due to an ageing population. Once symptomatic, heart valve diseases are potentially lethal, and heavily influence daily living and quality of life. Surgical treatment, either valve replacement or repair, remains the treatment of choice. However, post surgery, the transition to daily living may become a physical, mental and social challenge. We hypothesise that a comprehensive cardiac rehabilitation programme can improve physical capacity and self-assessed mental health and reduce hospitalisation and healthcare costs after heart valve surgery. Methods A randomised clinical trial, CopenHeartVR, aims to investigate whether cardiac rehabilitation in addition to usual care is superior to treatment as usual after heart valve surgery. The trial will randomly allocate 210 patients, 1:1 intervention to control group, using central randomisation, and blinded outcome assessment and statistical analyses. The intervention consists of 12 weeks of physical exercise, and a psycho-educational intervention comprising five consultations. Primary outcome is peak oxygen uptake (VO2 peak) measured by cardiopulmonary exercise testing with ventilatory gas analysis. Secondary outcome is self-assessed mental health measured by the standardised questionnaire Short Form 36. Also, long-term healthcare utilisation and mortality as well as biochemistry, echocardiography and cost-benefit will be assessed. A mixed-method design is used to evaluate qualitative and quantitative findings encompassing a survey-based study before the trial and a qualitative pre- and post-intervention study. Discussion The study is approved by the local regional Research Ethics Committee (H-1-2011-157), and the Danish Data Protection Agency (j.nr. 2007-58-0015).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Resternotomy for aortic valve replacement in patients with previous coronary artery bypass grafting and an internal mammary artery graft may be a surgical problem. Thus, we are exploring the effect of using rapid prototyping techniques for surgical planning and intraoperative orientation during aortic valve replacement after previous coronary artery bypass grafting (CABG). DESCRIPTION As a proof of concept, we studied a patient who had undergone CABG 5 years earlier. At that time the patient received a left internal mammary artery graft to the left anterior descending artery and a venous graft to the right coronary artery. Now the patient required aortic valve replacement due to symptomatic aortic valve stenosis. The left internal mammary artery bypass and the right coronary artery bypass were patent and showed good flow in the angiography. The patient was examined by 128-slice computed tomography. The image data were visualized and reconstructed. Afterwards, a replica showing the anatomic structures was fabricated using a rapid prototyping machine. EVALUATION Using data derived from 128-slice computed tomography angiography linked to proprietary software, we were able to create three-dimensional reconstructions of the vascular anatomy after the previous CABG. The models were sterilized and taken to the operating theatre for orientation during the surgical procedure. CONCLUSIONS Stereolithographic replicas are helpful for choosing treatment strategies in surgical planning and for intraoperative orientation during reoperations of patients with previous CABG.