847 resultados para Interferences Sample
Inversion effect of "old" vs "new" faces, face-like objects, and objects in a healthy student sample
Resumo:
L'objectif de cette étude est d'examiner la structure factorielle et la consistance interne de la TAS-20 sur un échantillon d'adolescents (n = 264), ainsi que de décrire la distribution des caractéristiques alexithymiques dans cet échantillon. La structure à trois facteurs de la TAS-20 a été confirmée par notre analyse factorielle confirmatoire. La consistance interne, mesurée à l'aide d'alpha de Cronbach, est acceptable pour le premier facteur (difficulté à identifier les sentiments (DIF)), bonne pour le second (difficulté à verbaliser les sentiments (DDF)), mais en revanche, faible pour le troisième facteur (pensées orientées vers l'extérieur (EOT)). Les résultats d'une Anova mettent en évidence une tendance linéaire indiquant que plus l'âge augmente plus le niveau d'alexithymie (score total TAS-20), la difficulté à identifier les sentiments et les pensées orientées vers l'extérieur diminuent. En ce qui concerne la prévalence de l'alexithymie, on remarque en effet que 38,5 % des adolescents de moins de 16 ans sont considérés comme alexithymiques, contre 30,1 % des 16-17 ans et 22 % des plus de 17 ans. Notre étude indique donc que la TAS-20 est un instrument adéquat pour évaluer l'alexithymie à l'adolescence, tout en suggérant quelques précautions étant donné l'aspect développemental de cette période.
Resumo:
To assess the associations between alcohol consumption and cytokine levels (interleukin-1beta - IL-1β; interleukin-6 - IL-6 and tumor necrosis factor-α - TNF-α) in a Caucasian population. Population sample of 2884 men and 3201 women aged 35-75. Alcohol consumption was categorized as nondrinkers, low (1-6 drinks/week), moderate (7-13/week) and high (14+/week). No difference in IL-1β levels was found between alcohol consumption categories. Low and moderate alcohol consumption led to lower IL-6 levels: median (interquartile range) 1.47 (0.70-3.51), 1.41 (0.70-3.32), 1.42 (0.66-3.19) and 1.70 (0.83-4.39) pg/ml for nondrinkers, low, moderate and high drinkers, respectively, p<0.01, but this association was no longer significant after multivariate adjustment. Compared to nondrinkers, moderate drinkers had the lowest odds (Odds ratio=0.86 (0.71-1.03)) of being in the highest quartile of IL-6, with a significant (p<0.05) quadratic trend. Low and moderate alcohol consumption led to lower TNF-α levels: 2.92 (1.79-4.63), 2.83 (1.84-4.48), 2.82 (1.76-4.34) and 3.15 (1.91-4.73) pg/ml for nondrinkers, low, moderate and high drinkers, respectively, p<0.02, and this difference remained borderline significant (p=0.06) after multivariate adjustment. Moderate drinkers had a lower odds (0.81 [0.68-0.98]) of being in the highest quartile of TNF-α. No specific alcoholic beverage (wine, beer or spirits) effect was found. Moderate alcohol consumption is associated with lower levels of IL-6 and (to a lesser degree) of TNF-α, irrespective of the type of alcohol consumed. No association was found between IL-1β levels and alcohol consumption.
Resumo:
Little information exists regarding the effect of several obesity markers on blood pressure (BP) levels in youth. Transverse study including 2494 boys and 2589 girls. Height, weight and waist were measured according to the international criteria and body fat (BF) by bioimpedance. BP was measured by an automated device. Hypertension was defined using sex-specific, age-specific and height-specific observation-points. Body mass index (BMI) and waist were positively related with systolic blood pressure (SBP) and diastolic blood pressure (DBP) and heart rate in both sexes, whereas the relationships with BF were less consistent. Stepwise linear regression analysis showed that BMI was positively related with SBP and DBP in both sexes, whereas BF was negatively related with SBP in both sexes and with heart rate in boys only; finally, waist was positively related with SBP in boys and heart rate in girls. Age and heart rate-adjusted values of SBP and DBP increased with BMI: for SBP, 117+/-1, 123+/-1 and 124+/-1 mmHg in normal, overweight and obese boys, respectively; corresponding values for girls were 111+/-1, 114+/-1 and 116+/-2 mmHg (mean+/-SE, P<0.001). Overweight and obese boys had an odds ratio for being hypertensive of 2.26 (95% confidence interval: 1.79-2.86) and 3.36 (2.32-4.87), respectively; corresponding values for girls were 1.58 (confidence interval 1.25-1.99) and 2.31 (1.53-3.50). BMI, not BF or waist, is consistently and independently related to BP levels in children; overweight and obesity considerably increase the risk of hypertension.
Resumo:
The Wechsler Intelligence Scale for Children-fourth edition (i.e. WISC-IV) recognizes a four-factor scoring structure in addition to the Full Scale IQ (FSIQ) score: Verbal Comprehension (VCI), Perceptual Reasoning (PRI), Working Memory (WMI), and Processing Speed (PSI) indices. However, several authors suggested that models based on the Cattell-Horn-Carroll (CHC) theory with 5 or 6 factors provided a better fit to the data than does the current four-factor solution. By comparing the current four-factor structure to CHC-based models, this research aimed to investigate the factorial structure and the constructs underlying the WISC-IV subtest scores with French-speaking Swiss children (N = 249). To deal with this goal, confirmatory factor analyses (CFAs) were conducted. Results showed that a CHC-based model with five factors better fitted the French-Swiss data than did the current WISC-IV scoring structure. All together, these results support the hypothesis of the appropriateness of the CHC model with French-speaking children.
Resumo:
This study investigated the psychometric properties of the Working Alliance Inventory-Client version (WAI-C) and Working Alliance Inventory-Short and revised (WAI-SR) in a career counseling setting. Moreover, it compared the impact of career versus personal counseling settings based on results obtained using the WAI-SR. Subjects were 188 French-speaking career counseling clients and 95 French-speaking personal counseling clients, mainly students. For the career counseling sample, total reliability was .87 for the WAI-C and .76 for the WAI-SR. The shape of the distribution was normal but the variance was significantly lower for the career counseling sample. Exploratory factor analyses (EFAs) and confirmatory factor analyses (CFAs) confirmed the presence of an overall working alliance factor but indicated a clearer hierarchical structure for the WAI- SR than for the WAI-C. The psychometric properties seemed only slightly affected by the counseling setting, suggesting that this inventory is also relevant for career counseling, especially the WAI-SR, which has a more robust factorial structure.
Resumo:
Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.
Resumo:
The nature of this research is to investigate paleoseismic deformation of glacial soft sediments from three sampling sites throughout the Scottish Highlands; Arrat's Mills, Meikleour and Glen Roy. The paleoseismic evidence investigated in this research will provide a basis for applying criteria to soft sediment deformation structures, and the trigger mechanisms that create these structures. Micromorphology is the tool used in this to investigate paleoseismic deformation structures in thin section. Thin section analysis, (micromorphology) of glacial sediments from the three sampling sites is used to determine microscale evidence of past earthquakes that can be correlated to modem-day events and possibly lead to a better understanding of the impact of earthquakes throughout a range of sediment types. The significance of the three sampling locations is their proximity to two major active fault zones that cross Scotland. The fault zones are the Highland Boundary Fault and the Great Glen Fault, these two major faults that parallel each other and divide the country in half Sims (1975) used a set of seven criteria that identified soft sediment deformation structures created by a magnitude six earthquake in Cahfomia. Using criteria set forth by Sims (1975), the paleoseismic evidence can be correlated to the magnitude of the deformation structures found in the glacial sediments. This research determined that the microstructures at Arrat's Mill, Meikleour and Glen Roy are consistent with a seismically induced origin. It has also been demonstrated that, even without the presence of macrostructures, the use of micromorphology techniques in detecting such activity within sediments is of immense value.
Resumo:
The effects of sample solvent composition and the injection volume, on the chromatographic peak profiles of two carbamate derivatives, methyl 2-benzimidazolecarbamate (MBC) and 3-butyl-2,4-dioxo[1,2-a]-s-triazinobenzimidazole (STB), were studied using reverse phase high performance liquid chromatograph. The study examined the effects of acetonitrile percentage in the sample solvent from 5 to 50%, effects of methanol percentage from 5 to 50%, effects of pH increase from 4.42 to 9.10, and effect of increasing buffer concentration from ° to 0.12M. The effects were studied at constant and increasing injection mass and at four injection volumes of 10, 50, 100 and 200 uL. The study demonstrated that the amount and the type of the organic solvents, the pH, and the buffer strength of the sample solution can have a pronounced effect on the peak heights, peak widths, and retention times of compounds analysed. MBC, which is capable of intramolecular hydrogen bonding and has no tendency to ionize, showed a predictable increase .in band broadening and a decrease in retention times at higher eluting strengths of the sample solvent. STB, which has a tendency to ionize or to strongly interact with the sample solvent, was influenced in various ways by the changes in ths sample solvent composition. The sample solvent effects became more pronounced as the injection volume increased and as the percentage of organic solvent in the sample solution became greater. The peak height increases for STB at increasing buffer concentrations became much more pronounced at higher analyte concentrations. It was shown that the widely accepted procedure of dissolving samples in the mobile phase does not yield the most efficient chromatograms. For that reason samples should be dissolved in the solutions with higher aqueous content than that of the mobile phase whenever possible. The results strongly recommend that all the samples and standards, regardless whether the standards are external or internal, be analysed at a constant sample composition and a constant injection volume.
Resumo:
This study investigated, retrospectively, whether recidivism in a sample of court-ordered'graduates of an alcohol education and awareness program could be predicted. This alcohol education program was based on adult education principles and was philosophically akin to the thoughts of Drs. Jack Mezirow, Stephen Brookfield, and Patricia Cranton. Data on the sample of 214 Halton IDEA (Impaired Driver Education and Awareness) graduates were entered into a spread sheet. Descriptive statistics were generated. Each of the 214 program graduates had taken several tests during the course of the IDEA program. These tests measured knowledge, attitude about impaired driving, and degree of alcohol involvement. Test scores were analyzed to determine whether those IDEA graduates who recidivated differed in any measurable way from those who had no further criminal convictions after a period of at least three years. Their criminal records were obtained from the Canadian Police Information Centre (CPIC). Those program graduates who reoffended were compared to the vast majority who did not reoffend. Results of the study indicated that there was no way to determine who would recidivate from the data that were collected. Further studies could use a qualitative model. Follow-up interviews could be used to determine what impact, if any, attendance at the IDEA program had on the life of the graduates.
Resumo:
Improvements have been made on the currently available hydride generator system manufactured by SpectraMetrics Incorporated, because the system was found to be unsatisfactory with respect to the following: 1. the drying agent, anhydrous calcium chloride, 2. the special sample tube, 3. the direction of argon flow through the Buchner funnel when it came to dealing with real sample, that is, with reference only to aqueous extracts of soil samples. Changes that were made on the system included the replacement of anhydrous calcium chloride with anhydrous calcium sulphate and the replacement of the special sample tube with a modified one made from silica. Re-directing the flow of argon through the top of the Buchner funnel appeared to make the system compatible with aqueous extracts of soil samples. The interferences from 1000 ~g/mL of nickel(II) , cobalt(II), iron(III), copper(II) have been eliminated with the aid of 1.4 M hydrochloric acid and 1% (weight/volume) L-cystine. Greater than 90% recovery of 0.3 ~g/mL arsenic signal was achieved in each case. Furthermore, 103% of arsenic signal was accomplished in the presence of 1000 ~g/mL cadmium with 5 M Hel. tVhen each of the interferents was present in solution at 1000 ppm, a recovery of 85% was achieved by using 5 M hydrochloric acid and 3% (weight/volume) L-cystine. Without L-cystine and when 1.4 M hydrochloric acid was used, the recoveries were 0% (Ni), 0% (Co), 88% (Fe), 15% (Cu), 18% (Cd). Similarly, a solution containing 1000 ppm of each interferent gave a zero percent recovery of arsenic. The reduction of trivalent and pentavalent arsenic at a pH less than one has also been investigated and shown to be quantitative if peak areas are measured. The reproducibility determination of a 0.3 Vg/mL standard arsenic solution by hydride generation shows a relative standard deviation of 3.4%. The detection limits with and without Porapak Q have been found to be 0.6 ng/mL and 1.0 ng/mL, respectively.
Resumo:
Analytical methods for the determination of trace amounts of germanium, tin and arsenic were established using hydride generation coupled with direct current plasma atomic emission spectrometry. A continuous gas flowing batch system for the hydride generation was investigated and was applied to the determination of germanium(Ge), tin(Sn), antimony(Sb) and lead(Pb) (Preliminary results suggest that it is also applicable to arsenic)As) ). With this system, the reproducibility of signals was improved and the determination was speeded up, compared with the conventional batch type hydride generation system. Each determination was complete within one minute. Interferences from a number of transition metal ions, especially from Pd(II), Pt(IV), Ni(II), Cu(II), Co(II), and Fe(II, III), have proven to be very serious under normal conditions, in the determination of germanium, tin, and arsenic. These interference effects were eliminated or significantly reduced in the presence of L-cystine or L-cysteine. Thus, a 10-1000 fold excess of Ni(II), Cu(II), Co(II), Fe(II), Pt(IV), Pd(II), etc. can be tolerated without interference, In the presence of L-cystine or L-cysteine, compared with absence of interference reducing agent. The methods for the determination of Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of standard reference materials gave excellent results of As and Sn contents in agreement with the certified values, showing there was no systematic interference. The detection limits for both germanium and tin were 20 pg ml- I . Preliminary studies were carried out for the determination of antimony and lead. Antimony was found to react with NaBH4, remaInIng from the previous determinations, giving an analytical signal. A reversed injection manner, i.e., injection of the NaBH4 solution prior to the analyte solution was used to avoid uncertainty caused by residual NaBH4 present and to ensure that an excess of NaB H4 was available. A solution of 0.4% L-cysteine was found to reduce the interference from selected transition metal ions, Co(II), Cu(II), Ni(II) and Pt(IV). Hydrochloric acid - hydrogen peroxide, nitric acid - ammonium persulphate, and potassium dichromate malic acid reaction systems for lead hydride generation were compared. The potassium dichromate - malic acid reaction medium proved to be the best with respect to reproducibility and minimal interference. Cu(II), Ni(II), and Fe(II) caused strong interference In lead determinations, which was not reduced by L-cysteine or Lcystine. Sodium citrate, ascorbic acid, dithizone, thiosemicarbazide and penicillamine reduced interferences to some extent. Further interference reduction studies were carried out uSIng a number of amino acids, glycine, alanine, valine, leucine and histidine, as possible interference reducing agents in the determination of germanium. From glycine, alanine, valine to leucine, the interference reduction effect in germanium determinations decreased. Histidine II was found to be very promising In the reduction of interference. In fact, histidine proved more efficient than L-cystine and L-cysteine In the reduction of interference from Ni(II) in the determination of germanium. Signal enhancement by easily ionized elements (EIEs), usually regarded as an interference effect in analysis by DCP-AES, was studied and successfully applied to advantage in improving the sensitivity and detection limit in the determination of As, Ge, Sn, Sb, and Pb. The effect of alkali and alkaline-earth elements on the determination of the above five hydride forming elements was studied. With the appropriate EIE, a signal enhancement of 40-115% was achieved. Linear calibration and good reproducibility were also obtained in the presence of EIEs. III
Resumo:
This study sought to compare the results of the Motivation Assessment Scale (MAS; Durand & Crimmins, 1988), Questions About Behavior Function Scale (QABF; Matson & Vollmer, 1996) and Functional Analysis Screening Tool (FAST; Iwata & Deleon, 1996), when completed by parent informants in a sample of children and youth with autism spectrum disorders (ASD) who display challenging behaviour. Results indicated that there was low agreement between the functional hypotheses derived from each of three measures. In addition, correlations between functionally analogous scales were substantially lower than expected, while correlations between non-analogous subscales were stronger than anticipated. As indicated by this study, clinicians choosing to use FBA questionnaires to assess behavioural function, may not obtain accurate functional hypotheses, potentially resulting in ineffective intervention plans. The current study underscores the caution that must be taken when asking parents to complete these questionnaires to determine the function(s) of challenging behaviour for children/youth with ASD.
Resumo:
The present research focused on the pathways through which the symptoms of posttraumatic stress disorder (PTSD) may negatively impact intimacy. Previous research has confirmed a link between self-reported PTSD symptoms and intimacy; however, a thorough examination of mediating paths, partner effects, and secondary traumatization has not yet been realized. With a sample of 297 heterosexual couples, intraindividual and dyadic models were developed to explain the relationships between PTSD symptoms and intimacy in the context of interdependence theory, attachment theory, and models of selfpreservation (e.g., fight-or-flight). The current study replicated the findings of others and has supported a process in which affective (alexithymia, negative affect, positive affect) and communication (demand-withdraw behaviour, self-concealment, and constructive communication) pathways mediate the intraindividual and dyadic relationships between PTSD symptoms and intimacy. Moreover, it also found that the PTSD symptoms of each partner were significantly related; however, this was only the case for those dyads in which the partners had disclosed most everything about their traumatic experiences. As such, secondary traumatization was supported. Finally, although the overall pattern of results suggest a total negative effect of PTSD symptoms on intimacy, a sex difference was evident such that the direct effect of the woman's PTSD symptoms were positively associated with both her and her partner's intimacy. I t is possible that the Tend-andBefriend model of threat response, wherein women are said to foster social bonds in the face of distress, may account for this sex difference. Overall, however, it is clear that PTSD symptoms were negatively associated with relationship quality and attention to this impact in the development of diagnostic criteria and treatment protocols is necessary.
Resumo:
Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in quadrupole based inductively coupled plasma mass spectrometry (ICP-MS) applications. A study was conducted to develop an accurate method for the determination of vanadium in lake sediment samples by ICP-MS, coupled with a dynamic reaction cell (DRC), using two differenvchemical resolution strategies: a) direct removal of interfering C10+ and b) vanadium oxidation to VO+. The performance of three reaction gases that are suitable for handling vanadium interference in the dynamic reaction cell was systematically studied and evaluated: ammonia for C10+ removal and oxygen and nitrous oxide for oxidation. Although it was able to produce comparable results for vanadium to those using oxygen and nitrous oxide, NH3 did not completely eliminate a matrix effect, caused by the presence of chloride, and required large scale dilutions (and a concomitant increase in variance) when the sample and/or the digestion medium contained large amounts of chloride. Among the three candidate reaction gases at their optimized Eonditions, creation of VO+ with oxygen gas delivered the best analyte sensitivity and the lowest detection limit (2.7 ng L-1). Vanadium results obtained from fourteen lake sediment samples and a certified reference material (CRM031-040-1), using two different analytelinterference separation strategies, suggested that the vanadium mono-oxidation offers advantageous performance over the conventional method using NH3 for ultra-trace vanadium determination by ICP-DRC-MS and can be readily employed in relevant environmental chemistry applications that deal with ultra-trace contaminants.Part II: Validation of a modified oxidation approach for the quantification of total arsenic and selenium in complex environmental matrices Spectroscopic interference problems of arsenic and selenium in ICP-MS practices were investigated in detail. Preliminary literature review suggested that oxygen could serve as an effective candidate reaction gas for analysis of the two elements in dynamic reaction cell coupled ICP-MS. An accurate method was developed for the determination of As and Se in complex environmental samples, based on a series of modifications on an oxidation approach for As and Se previously reported. Rhodium was used as internal standard in this study to help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se isotope, 80Se, selenium was determined by a second most abundant isotope, 78Se, in the form of 78Se160. Upon careful selection of oxygen gas flow rate and optimization ofRPq value, previous isobaric threats caused by Zr and Mo were reduced to background levels whereas another potential atomic isobar, 96Ru+, became completely harmless to the new selenium analyte. The new method underwent a strict validation procedure where the recovery of a suitable certified reference material was examined and the obtained sample data were compared with those produced by a credible external laboratory who analyzed the same set of samples using a standardized HG-ICP-AES method. The validation results were satisfactory. The resultant limits of detection for arsenic and selenium were 5 ng L-1 and 60 ng L-1, respectively.