933 resultados para High Density Urban Form
Resumo:
"AEDC-TR-67-72"
Resumo:
Mode of access: Internet.
Resumo:
"April 15, 1969."
Resumo:
"To investigate and study all aspects of 'four-plus-one' apartment buildings in particular and high-density housing in general."
Resumo:
Aims Fibrates or nicotinic acid are usually recommended for secondary prevention of coronary heart disease in patients with low plasma levels of both low-density tipoprotein cholesterol (LDL-C) less than or equal to140 mg/dL (less than or equal to3.6 mmol/L) and high-density lipoprotein cholesterol (HDL-C) less than or equal to40 mg/dL (less than or equal to1.03 mmol/L). The LIPID trial, a randomised, placebo-controlled trial in 9014 patients at 87 centres in Australia and New Zealand, provided an opportunity to investigate the effects of an HMG-CoA reductase inhibitor in patients with tow LDL-C and tow HDL-C. Methods and results Participants in this post hoc substudy were 2073 patients aged 31-75 years with baseline LDL-C less than or equal to140 mg/dL (less than or equal to3.6 mmoL/L), HDL-C less than or equal to40 mg/dL (less than or equal to1.03 mmol/L), and triglyceride less than or equal to300 mg/dL (less than or equal to3.4 mmol/L). The relative risk reduction with pravastatin treatment was 27% for major coronary events (95% Cl 8-42%), 27% for coronary heart disease mortality (95% CI 0-47%), 21% for all-cause mortality (95% Cl 0-38%), and 51% for stroke (95% CI 24-69%). The number needed to treat to prevent a major coronary event over 6 years was 22. Conclusions Treatment with pravastatin in patients with both low LDL-C and low HDL-C significantly reduced major coronary events, stroke, and all-cause mortality. The level of HDL-C is crucial to the risk of recurrent CHD events and, consequently, the benefit of lowering LDL-C. (C) 2004 Published by Elsevier Ltd on behalf of The European Society of Cardiology.
Resumo:
The thermal degradation of high density polyethylene has been modelled by the random breakage of polymer bonds, using a set of population balance equations. A model was proposed in which the population balances were lumped into representative sizes so that the experimentally determined molecular weight distribution of the original polymer could be used as the initial condition. This model was then compared to two different cases of the unlumped population balance which assumed unimolecular initial distributions of 100 and 500 monomer units, respectively. The model that utilised the experimentally determined molecular weight distribution was found to best describe the experimental data. The model fits suggested a second mechanism in addition to random breakage at slow reaction rates. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The high intensity zone within the Jameson Cell is the downcomer. It is largely external and separated from the flotation tank. This, together with operation of the downcomer under vacuum, rather than at elevated pressure and the absence of moving parts, allows ready access to the high intensity zone for measurement and analysis. Experimentation was conducted allowing measurements of recovery for residence times of between 20 milliseconds and ten seconds within the downcomer of a Jameson Cell. The affect of aeration rate on the recovery of different particle sizes was also studied.
Resumo:
The total thermoplastics pipe market in west Europe is estimated at 900,000 metric tonnes for 1977 and is projected to grow to some 1.3 million tonnes of predominantly PVC and polyolefins pipe by 1985. By that time, polyethylene for gas distribution pipe and fittings will represent some 30% of the total polyethylene pipe market. The performance characteristics of a high density polyethylene are significantly influenced by both molecular weight and type of comonomer; the major influences being in the long-term hoop stress resistance and the environmental stress cracking resistance. Minor amounts of hexene-1 are more effective than comonomers lower in the homologous series, although there is some sacrifice of density related properties. A synergistic improvement is obtained by combining molecular weight increase with copolymerisation. The Long-term design strength of polyethylene copolymers can be determined from hoop stress measurement at elevated temperatures and by means of a separation factor of approximate value 22, extrapolation can be made to room temperature performance for a water environment. A polyethylene of black composition has a sufficiently improved performance over yellow pigmented pipe to cast doubts on the validity of internationally specifying yellow coded pipe for gas distribution service. The chemical environment (condensate formation) that can exist in natural gas distribution networks has a deleterious effect on the pipe performance the reduction amounting to at least two decades in log time. Desorption of such condensate is very slow and the influence of the more aggressive aromatic components is to lead to premature stress cracking. For natural gas distribution purposes, the design stress rating should be 39 Kg/cm2 for polyethylenes in the molecular weight range of 150 - 200,000 and 55 Kg/cm2 for higher molecular weight materials.
Resumo:
The research examines the deposition of airborne particles which contain heavy metals and investigates the methods that can be used to identify their sources. The research focuses on lead and cadmium because these two metals are of growing public and scientific concern on environmental health grounds. The research consists of three distinct parts. The first is the development and evaluation of a new deposition measurement instrument - the deposit cannister - designed specifically for large-scale surveys in urban areas. The deposit cannister is specifically designed to be cheap, robust, and versatile and therefore to permit comprehensive high-density urban surveys. The siting policy reduces contamination from locally resuspended surface-dust. The second part of the research has involved detailed surveys of heavy metal deposition in Walsall, West Midlands, using the new high-density measurement method. The main survey, conducted over a six-week period in November - December 1982, provided 30-day samples of deposition at 250 different sites. The results have been used to examine the magnitude and spatial variability of deposition rates in the case-study area, and to evaluate the performance of the measurement method. The third part of the research has been to conduct a 'source-identification' exercise. The methods used have been Receptor Models - Factor Analysis and Cluster Analysis - and a predictive source-based deposition model. The results indicate that there are six main source processes contributing to deposition of metals in the Walsall area: coal combustion, vehicle emissions, ironfounding, copper refining and two general industrial/urban processes. |A source-based deposition model has been calibrated using facctorscores for one source factor as the dependent variable, rather than metal deposition rates, thus avoiding problems traditionally encountered in calibrating models in complex multi-source areas. Empirical evidence supports the hypothesised associatlon of this factor with emissions of metals from the ironfoundry industry.