998 resultados para Heinämaa, Sara


Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objectivo deste estudo é apresentar os resultados de uma análise diagnóstica da atuação institucional relativamente às situações de violência infanto-juvenil em três territórios de um concelho da períferia de Lisboa(Portugal)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copyright: © 2014 Rodrigues et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Myocardial Perfusion Imaging (MPI) is a very important tool in the assessment of Coronary Artery Disease ( CAD ) patient s and worldwide data demonstrate an increasingly wider use and clinical acceptance. Nevertheless, it is a complex process and it is quite vulnerable concerning the amount and type of possible artefacts, some of them affecting seriously the overall quality and the clinical utility of the obtained data. One of the most in convenient artefacts , but relatively frequent ( 20% of the cases ) , is relate d with patient motion during image acquisition . Mostly, in those situations, specific data is evaluated and a decisi on is made between A) accept the results as they are , consider ing that t he “noise” so introduced does not affect too seriously the final clinical information, or B) to repeat the acquisition process . Another possib ility could be to use the “ Motion Correcti on Software” provided within the software package included in any actual gamma camera. The aim of this study is to compare the quality of the final images , obtained after the application of motion correction software and after the repetition of image acqui sition. Material and Methods Thirty cases of MPI affected by Motion Artefacts and repeated , were used. A group of three, independent (blinded for the differences of origin) expert Nuclear Medicine Clinicians had been invited to evaluate the 30 sets of thre e images - one set for each patient - being ( A) original image , motion uncorrected , (B) original image, motion corrected, and (C) second acquisition image, without motion . The results so obtained were statistically analysed . Results and Conclusion Results obtained demonstrate that the use of the Motion Correction Software is useful essentiall y if the amplitude of movement is not too important (with this specific quantification found hard to define precisely , due to discrepancies between clinicians and other factors , namely between one to another brand); when that is not the case and the amplitude of movement is too important , the n the percentage of agreement between clinicians is much higher and the repetition of the examination is unanimously considered ind ispensable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: 188Re is a promising radionuclide for metabolic therapy because of the emission of high energy beta-particles. The development of watersoluble bone-seeking polymers such as PEI-MP (polyethyleneimine, functionalised with methylphosphonate-groups) that might be labeled with 188Re are recent approaches, with a strong potential for bone cancer treatment. The aim of this study was to evaluate the efficacy of 188Re-PEI-MP, as therapeutic agent for osteosarcoma, through in vitro and in vivo models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Analisar a mortalidade intra-hospitalar dos recém-nascidos de muito baixo peso, considerando a evolução clínica e os fatores associados à mortalidade. MÉTODOS: Estudo longitudinal que incluiu 360 recém-nascidos com peso entre 500 e 1.500g, em Londrina, Paraná, de 1/1/2002 a 30/6/2004. Os dados foram coletados por meio de entrevistas com as mães, análise dos prontuários e acompanhamento dos recém-nascidos. Para determinação de associação entre as variáveis utilizou-se o teste do qui-quadrado e análise de regressão logística com modelo hierarquizado, com nível de significância de 5%. RESULTADOS: A taxa de mortalidade foi de 32,5%. Na análise bivariada, as variáveis associadas ao óbito oram: não uso de corticosteróide antenatal, ausência de hipertensão arterial/pré-eclampsia, presença de trabalho de parto, parto normal, apresentação não cefálica, Apgar < 3 no primeiro e quinto minutos, Clinical Risk Index for Babies > 5, reanimação na sala de parto, sexo masculino, idade gestacional < 28 semanas, peso < 750g, síndrome do desconforto respiratório, pneumotórax, hemorragia intracraniana e ventilação mecânica. Após regressão logística, permaneceram como fatores de risco: baixa renda per capita, não uso de corticosteróide antenatal e não uso de pressão positiva contínua de vias aéreas. CONCLUSÕES: Mesmo com o uso de tecnologias, a mortalidade observada nos recém-nascidos de muito baixo peso foi alta quando comparada com os países desenvolvidos. A maior utilização do corticosteróide antenatal poderá diminuir a morbidade e mortalidade de recém-nascidos de muito baixo peso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Educação de Lisboa para a obtenção do grau de Mestre em Ciências da Educação, especialização em Educação Social e Intervenção Comunitária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Interpretação Consecutiva consiste em ―écouter une information, à se l’approprier mentalement et à la rendre pour un auditoire donné ‖.(LEDERER, 1981:99) Como é evidente, esta operação pressupõe um domínio perfeito e total das línguas utilizadas, mas as operações mentais e cognitivas envolvidas exigem uma formação especial adequada, da qual o conhecimento das línguas é apenas uma parte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente artigo consagra-se à redescoberta de alguns dos textos que, na Europa do passado, foram fazendo a pedagogia da morte cristã, propondo atitudes normativas, morais como orações, culpas e arrependimentos, asceses como espiritualidades, ensinando verdadeiramente a bem morrer. Conhecidos desde o período medieval, alguns desses textos mais frequentados haveriam de cristalizar-se numa ars moriendi em que se oferecia, desde o período quatrocentista, um texto muitas vezes procurado, compulsado e copiado, mas intimamente ligado a uma iconografia que parecia mesmo sobrepujar essas lições fixadas pela ―arte de morrer‖.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado em Psicologia da Educação, especialidade em Contextos Educativos.