981 resultados para Heart Valve Diseases, Pulmonary Embolism
Resumo:
QUESTIONS UNDER STUDY: We assessed the occurrence and aetiology of chest pain in primary care practice. These features differ between primary and emergency care settings, where most previous studies have been performed. METHODS: 59 GPs in western Switzerland recorded all consecutive cases presenting with chest pain. Clinical characteristics, laboratory tests and other investigations as well as the diagnoses remaining after 12 months of follow-up were systematically registered. RESULTS: Among 24,620 patients examined during a total duration of 300 weeks of observation, 672 (2.7%) presented with chest pain (52% female, mean age 55 +/- 19(SD)). Most cases, 442 (1.8%), presented new symptoms and in 356 (1.4%) it was the reason for consulting. Over 40 ailments were diagnosed: musculoskeletal chest pain (including chest wall syndrome) (49%), cardiovascular (16%), psychogenic (11%), respiratory (10%), digestive (8%), miscellaneous (2%) and without diagnosis (3%). The three most prevalent diseases were: chest wall syndrome (43%), coronary artery disease (12%) and anxiety (7%). Unstable angina (6), myocardial infarction (4) and pulmonary embolism (2) were uncommon (1.8%). Potentially serious conditions including cardiac, respiratory and neoplasic diseases accounted for 20% of cases. A large number of laboratory tests (42%), referral to a specialist (16%) or hospitalisation (5%) were performed. Twentyfive patients died during follow-up, of which twelve were for a reason directly associated with thoracic pain [cancer (7) and cardiac causes (5)]. CONCLUSIONS: Thoracic pain was present in 2.7% of primary care consultations. Chest wall syndrome pain was the main aetiology. Cardio - vascular emergencies were uncommon. However chest pain deserves full consideration because of the occurrence of potentially serious conditions.
Resumo:
BACKGROUND: In patients with acute venous thromboembolism and renal insufficiency, initial therapy with unfractionated heparin may have some advantages over low-molecular-weight heparin. METHODS: We used the Registro Informatizado de la Enfermedad TromboEmbólica (RIETE) Registry data to evaluate the 15-day outcome in 38,531 recruited patients. We used propensity score matching to compare patients treated with unfractionated heparin with those treated with low-molecular-weight heparin in 3 groups stratified by creatinine clearance levels at baseline: >60 mL/min, 30 to 60 mL/min, or <30 mL/min. RESULTS: Patients initially receiving unfractionated heparin therapy (n = 2167) more likely had underlying diseases than those receiving low-molecular-weight heparin (n = 34,665). Propensity score-matched groups of patients with creatinine clearance levels >60 mL/min (n = 1598 matched pairs), 30 to 60 mL/min (n = 277 matched pairs), and <30 mL/min (n = 210 matched pairs) showed an increased 15-day mortality for unfractionated heparin compared with low-molecular-weight heparin (4.5% vs 2.4% [P = .001], 5.4% vs 5.8% [P = not significant], and 15% vs 8.1% [P = .02], respectively), an increased rate of fatal pulmonary embolism (2.8% vs 1.2% [P = .001], 3.2% vs 2.5% [P = not significant], and 5.7% vs 2.4% [P = .02], respectively), and a similar rate of fatal bleeding (0.3% vs 0.3%, 0.7% vs 0.7%, and 0.5% vs 0.0%, respectively). Multivariate analysis confirmed that patients treated with unfractionated heparin were at increased risk for all-cause death (odds ratio, 1.8; 95% confidence interval, 1.3-2.4) and fatal pulmonary embolism (odds ratio, 2.3; 95% confidence interval, 1.5-3.6). CONCLUSIONS: In comparison with low-molecular-weight heparin, initial therapy with unfractionated heparin was associated with a higher mortality and higher rate of fatal pulmonary embolism in patients with creatinine clearance levels >60 mL/min or <30 mL/min, but not in those with levels between 30 and 60 mL/min.
Resumo:
The transapical transcatheter aortic valve implantation (TA-TAVI) in degenerated aortic bioprosthesis is an emerging therapy for surgically non-amenable patients. However, the presence of different types of aortic bioprostheses (stented and stentless), available in different sizes (19-27 mm), can be at the origin of important mismatches between the malfunctioning, degenerated aortic valves and the inner stent-valves implanted through transapical accesses (23 and 26 mm Edwards Sapien transcatheter stent-valves). We report an emergency TA-TAVI treatment of a severely regurgitant degenerated 23 mm Mitroflow aortic bioprosthesis (Sorin Group, Milano, Italy) implanted seven years earlier in an 80-year-old lady, and we reviewed the current available literature about transapical 'valve-in-valve' procedures to analyze the hemodynamic results and the ideal 'prosthesis-to-prosthesis' match.
Resumo:
Atrial septal defect (ASD) typically is asymptomatic in infancy and early childhood and elective defect closure usually is performed at an age between 4 - 6 years. Severe pulmonary hypertension (PHT) complicating an ASD is seen in adulthood and has only occasionally been reported in small children. A retrospective study was undertaken to evaluate the incidence of severe PHT complicating an isolated ASD and requiring early surgical correction in the fi rst year of life. 355 pediatric patients underwent treatment for an isolated ASD either surgically or by catheter intervention during a 10 year period (1996 - 2006) at two tertiary referral centers. 297 patients had secundum ASD and 58 primum ASD with mild to moderate mitral regurgitation. 8 infants were found with isolated ASD (six with secundum and two with primum ASD) associated with signifi cant PHT, accounting for 2.2% of all ASD patients in our centers. These 8 infants had invasively measured pulmonary artery pressures between 50 and 100% of systemic pressure. Median size of the ASD at the time of surgery was 14mm (7 - 20). They were operated in the fi rst year of life and had complicated postoperative courses requiring specifi c treatment for PHT for up to 16 weeks (median 12) postoperatively. Compared to ASD patients without PHT these infants had prolonged postoperative ICU stay of 5 - 9 days (median 8) and prolonged perioperative overall hospital stay of 8 - 32 days (median 15). Ultimate outcome in all 8 infants was good with persistent normalization of pulmonary pressures during mid-term follow-up of between 8 to 60 months (median 28). All other ASD patients had normal pulmonary pressures and mean age at defect closure was higher being 6.2 years for secundum ASD and 3.2 years for primum ASD. In conclusion, ASD is rarely associated with signifi cant PHT in infancy but then requires early surgery to normalize the prognosis of the patients.
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
BACKGROUND: Aortoplasty has been advocated for moderate dilatation of the ascending aorta associated with aortic valve disease. We report our results with this conservative approach. METHODS: Seventeen consecutive patients with unsupported aortoplasty were reviewed. Twelve patients had aortic valve regurgitation and 5 had stenosis. The aortic wall was analyzed histologically in 14 patients. Follow-up was complete, with a mean time of 6 years (range, 2.3 to 10.5 years). RESULTS: Two patients among the 15 hospital survivors died during follow-up of causes unrelated to aortic pathology. Survival at 7 years was 86.7% (+/- 8.8%). Recurring aortic aneurysms developed in 4 patients after a mean time of 63 months, with an event-free survival at 7 years of 41% (+/- 21%). All of these 4 patients had aortic valve regurgitation and cystic medial necrosis. CONCLUSIONS: The recurrence rate of aneurysms after unsupported aortoplasty and aortic valve replacement is high in patients with aortic regurgitation. This strongly suggests that in these patients, the aortic dilatation is related to an underlying wall deficiency, associated with the aortic valve pathology, rather than to the hemodynamic stress imposed by the aortic valve disease.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.
Resumo:
IMPORTANCE: There are limited prospective, controlled data evaluating survival in patients receiving early surgery vs medical therapy for prosthetic valve endocarditis (PVE). OBJECTIVE: To determine the in-hospital and 1-year mortality in patients with PVE who undergo valve replacement during index hospitalization compared with patients who receive medical therapy alone, after controlling for survival and treatment selection bias. DESIGN, SETTING, AND PARTICIPANTS: Participants were enrolled between June 2000 and December 2006 in the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), a prospective, multinational, observational cohort of patients with infective endocarditis. Patients hospitalized with definite right- or left-sided PVE were included in the analysis. We evaluated the effect of treatment assignment on mortality, after adjusting for biases using a Cox proportional hazards model that included inverse probability of treatment weighting and surgery as a time-dependent covariate. The cohort was stratified by probability (propensity) for surgery, and outcomes were compared between the treatment groups within each stratum. INTERVENTIONS: Valve replacement during index hospitalization (early surgery) vs medical therapy. MAIN OUTCOMES AND MEASURES: In-hospital and 1-year mortality. RESULTS: Of the 1025 patients with PVE, 490 patients (47.8%) underwent early surgery and 535 individuals (52.2%) received medical therapy alone. Compared with medical therapy, early surgery was associated with lower in-hospital mortality in the unadjusted analysis and after controlling for treatment selection bias (in-hospital mortality: hazard ratio [HR], 0.44 [95% CI, 0.38-0.52] and lower 1-year mortality: HR, 0.57 [95% CI, 0.49-0.67]). The lower mortality associated with surgery did not persist after adjustment for survivor bias (in-hospital mortality: HR, 0.90 [95% CI, 0.76-1.07] and 1-year mortality: HR, 1.04 [95% CI, 0.89-1.23]). Subgroup analysis indicated a lower in-hospital mortality with early surgery in the highest surgical propensity quintile (21.2% vs 37.5%; P = .03). At 1-year follow-up, the reduced mortality with surgery was observed in the fourth (24.8% vs 42.9%; P = .007) and fifth (27.9% vs 50.0%; P = .007) quintiles of surgical propensity. CONCLUSIONS AND RELEVANCE: Prosthetic valve endocarditis remains associated with a high 1-year mortality rate. After adjustment for differences in clinical characteristics and survival bias, early valve replacement was not associated with lower mortality compared with medical therapy in the overall cohort. Further studies are needed to define the effect and timing of surgery in patients with PVE who have indications for surgery.
Resumo:
Background: Inflammatory bowel disease (IBD) patients have an increased risk of venous thromboembolic complications (VTEC) such as deep vein thrombosis (DVT) and pulmonary embolism when compared to the non-IBD population. However, studies assessing VTEC prevalence in IBD as well as analyses of VTEC associated risk factors are scarce. We aimed to assess VTEC prevalence in IBD patients and to identify associated risk factors. Methods: Data from patients enrolled in the Swiss IBD Cohort Study (SIBDCS) were analyzed. Since 2006 the SIBDCS collects data on a large sample of IBD patients from hospitals and private practices across Switzerland. Results: A total of 90/2284 (3.94%) IBD patients suffered from VTEC. Of these, 45/1324 (3.4% overall; 2.42% with DVT, 1.51% with PE) had CD, and 45/960 (4.7% overall; 3.23% with DVT, 2.40% with PE) presented with UC.
Resumo:
During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.
Resumo:
BACKGROUND: No studies have identified which patients with upper-extremity deep vein thrombosis (DVT) are at low risk for adverse events within the first week of therapy. METHODS: We used data from Registro Informatizado de la Enfermedad TromboEmbólica to explore in patients with upper-extremity DVT a prognostic score that correctly identified patients with lower limb DVT at low risk for pulmonary embolism, major bleeding, or death within the first week. RESULTS: As of December 2014, 1135 outpatients with upper-extremity DVT were recruited. Of these, 515 (45%) were treated at home. During the first week, three patients (0.26%) experienced pulmonary embolism, two (0.18%) had major bleeding, and four (0.35%) died. We assigned 1 point to patients with chronic heart failure, creatinine clearance levels 30-60 mL min(-1) , recent bleeding, abnormal platelet count, recent immobility, or cancer without metastases; 2 points to those with metastatic cancer; and 3 points to those with creatinine clearance levels < 30 mL min(-1) . Overall, 759 (67%) patients scored ≤ 1 point and were considered to be at low risk. The rate of the composite outcome within the first week was 0.26% (95% confidence interval [CI] 0.004-0.87) in patients at low risk and 1.86% (95% CI 0.81-3.68) in the remaining patients. C-statistics was 0.73 (95% CI 0.57-0.88). Net reclassification improvement was 22%, and integrated discrimination improvement was 0.0055. CONCLUSIONS: Using six easily available variables, we identified outpatients with upper-extremity DVT at low risk for adverse events within the first week. These data may help to safely treat more patients at home.
Resumo:
INTRODUCTION: Venous thromboembolism (VTE) carries a considerable risk of recurrence and anticoagulants should be administered for a minimum of three months. Since little is known about real life management of VTE, we aimed to describe current practice in the secondary prevention of VTE. MATERIALS AND METHODS: Using the database of an international, prospective registry on patients treated for VTE, RIETE, information was collected on risk factors for VTE and bleeding, anticoagulant treatment, and clinical outcomes during follow up. Multivariate analysis using logistic regression was performed to identify predictors of treatment duration. RESULTS: Of 6944 patients with a first episode of VTE 41.1% had unprovoked VTE, 31.8% had transient risk factors, 27.1% had cancer. After the exclusion of patients who died during the first year of observation, the rate of patients treated for >12 months was 55.1%, 41.9%, and 43.2%, respectively (p<0.001). Pulmonary embolism at presentation, recurrence while on treatment, chronic heart failure and age >65 years were independently associated with treatment for >12 months. Body weight <75 kg, anemia, cancer, and the presence of transient risk factors were associated with treatment for 12 months or less. Major bleeding occurred more frequently than recurrent VTE in patients with VTE secondary to transient risk factors and cancer; fatal bleeding was more frequent than fatal recurrent PE in all subgroups. CONCLUSIONS: We observed heterogeneous duration of anticoagulant treatment for the secondary prevention of VTE. A substantial proportion of patients, in particular those with VTE secondary to transient risk factors, may be exposed to a possibly unnecessary risk of bleeding.
Resumo:
Abstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations.