992 resultados para Frequency stability
Resumo:
Condensation of (-)-norephedrine with excess formaldehyde under mild conditions leads to formation of the 2:1 condensation product N,N'-methylenebis(4-methyl-5-phenyl)oxazolidine compared with the reaction with 1 mol of formaldehyde, which leads to 4-methyl-5-phenyloxazolidine. H-1 and C-13 NMR spectroscopy was used to monitor the stability of this compound and its decomposition products. The 2:1 condensation product is found to be stable in CDC1(3) but breaks down rapidly in CD3OD to yield a 50:50 mixture of 4-methyl-5-phenyloxazolidine and 3-hydroxymethyl-4-methyl-5-phenyloxazolidine. Upon addition of D2O to this equimolar mixture, the latter compound decomposes to norephedrine and formaldehyde, whereas the former compound is stable. (C) 1997 by John Wiley & Sons, Ltd.
Resumo:
We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.
Resumo:
As nuclear magnetic resonance imaging and spectroscopy move inexorably toward higher field-strength magnets in search of improved signal-to-noise ratio, spectral resolution, and spatial resolution, the way in which radiofrequency (RF) probes are designed changes. At higher frequencies, resonant cavities become the favored RF ''coil'' type and may be built using streamline elements to reduce the inductance of the system. In modeling such systems, the quasi-static approach of assuming that current flows evenly in all conductor cross sections and that adjacent conductors do not affect each other becomes less reasonable. The proximity of RF conductors in resonators typically causes RF eddy currents to flow, whereby the current density in each rung is altered by the RF fields generated by nearby conductors. The proper understanding and prediction of how resonators will perform require a model of the current densities flowing in conducting sections, including all RF eddy current effects. Very few models of this type have been presented in the literature. This article presents an overview of one such model and of how it may be applied to a variety of resonators, both shielded and unshielded, circular, and elliptical, in cross section. Results are presented from a shielded head coil operating at 2 tesla. (C) 1997 John Wiley & Sons, Inc.
Resumo:
Background: Tetralogy of Fallot (TOF) is a congenital conotruncal heart defect commonly found in DiGeorge (DGS) and velocardiofacial (VCFS) syndromes. The deletion of chromosome 22q11 has also been demonstrated in sporadic or familial cases of TOF. The aim of the present study was to investigate the frequency of del22q11 in patients with non-syndromic TOF seen at a tertiary Pediatric Cardiology care center. Method: One hundred and twenty three non-syndromic TOF patients were selected and evaluated by history, physical examination and review of medical records. Venous blood was drawn for genomic DNA extraction after informed consent 22q11 microdeletion diagnosis was conducted through a standardized SNP genotyping assay and consecutive homozygosity mapping. Phenotype-genotype correlations regarding cardiac anatomy were conducted. Results: We evaluated 123 non-syndromic TOF patients for a 22q11 deletion. 105 (85.4%) patients presented pulmonary stenosis and 18 (14.6%) had pulmonary atresia. Eight patients (6.5%) were found to have a deletion. Of the deleted patients, three (37.5%) presented pulmonary atresia. We have verified a tendency towards a higher prevalence of pulmonary atresia when comparing TOF patients with and without 22q11 microdeletion. Conclusions: 22q11.2 deletion in non-syndromic TOF patients is present in approximately 6% of patients. We suggest a tendency towards a higher prevalence of pulmonary atresia in non-syndromic TOF patients with 22q11 microdeletion. Molecular genetic screening of non-syndromic TOF patient may be important for the correct care of these patients and a more specific genetic diagnostic and counseling. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
O-Acyl esters were prepared from salicylic acid and diflunisal by esterification with the appropriate acyl anhydride (in the presence of sulfuric acid at 80 degrees C) or acyl chloride (in the presence of pyridine at 0 degrees C). Synthesis, identification and characterization of these compounds is described. In vitro hydrolysis, solubility and protein binding studies of these O-acyl esters were performed. For the diflunisal esters, the melting points fell as the side chain was increased from ethyl to pentyl. The melting points showed no significant difference as the length of the side chain was increased from pentyl to heptyl. The aspirin analogues showed a similar trend, The relationship between solubility and carbon chain length agreed closely with that for the melting points with carbon chain length. In vitro non-enzymatic hydrolysis studies concluded that: (1) hydrolysis rate constants generally decreased with carbon chain length; (2) the diflunisal esters have shorter half lives compared with their salicylate counterparts; and (3) the in vitro hydrolysis of these compounds was retarded by the presence of bovine serum albumin. Protein binding experiments showed that the strength of binding of the aspirin and diflunisal analogues to bovine serum albumin increased with carbon chain length. (C) 1997 Elsevier Science B.V.
Resumo:
DsbA, a 21-kDa protein from Escherichia coli, is a potent oxidizing disulfide catalyst required for disulfide bond formation in secreted proteins. The active site of DsbA is similar to that of mammalian protein disulfide isomerases, and includes a reversible disulfide bond formed from cysteines separated by two residues (Cys3O-Pro31-His32-Cys33). Unlike most protein disulfides, the active-site disulfide of DsbA is highly reactive and the oxidized form of DsbA is much less stable than the reduced form at physiological pH. His32, one of the two residues between the active-site cysteines, is critical to the oxidizing power of DsbA and to the relative instability of the protein in the oxidized form. Mutation of this single residue to tyrosine, serine, or leucine results in a significant increase in stability (of similar to 5-7 kcal/mol) of the oxidized His32 variants relative to the oxidized wild-type protein. Despite the dramatic changes in stability, the structures of all three oxidized DsbA His32 Variants are very similar to the wild-type oxidized structure, including conservation of solvent atoms near the active-site residue, Cys3O. These results show that the His32 residue does not exert a conformational effect on the structure of DsbA. The destabilizing effect of His32 on oxidized DsbA is therefore most likely electrostatic in nature.
Resumo:
The popular Newmark algorithm, used for implicit direct integration of structural dynamics, is extended by means of a nodal partition to permit use of different timesteps in different regions of a structural model. The algorithm developed has as a special case an explicit-explicit subcycling algorithm previously reported by Belytschko, Yen and Mullen. That algorithm has been shown, in the absence of damping or other energy dissipation, to exhibit instability over narrow timestep ranges that become narrower as the number of degrees of freedom increases, making them unlikely to be encountered in practice. The present algorithm avoids such instabilities in the case of a one to two timestep ratio (two subcycles), achieving unconditional stability in an exponential sense for a linear problem. However, with three or more subcycles, the trapezoidal rule exhibits stability that becomes conditional, falling towards that of the central difference method as the number of subcycles increases. Instabilities over narrow timestep ranges, that become narrower as the model size increases, also appear with three or more subcycles. However by moving the partition between timesteps one row of elements into the region suitable for integration with the larger timestep these the unstable timestep ranges become extremely narrow, even in simple systems with a few degrees of freedom. As well, accuracy is improved. Use of a version of the Newmark algorithm that dissipates high frequencies minimises or eliminates these narrow bands of instability. Viscous damping is also shown to remove these instabilities, at the expense of having more effect on the low frequency response.
Resumo:
We consider solutions to the second-harmonic generation equations in two-and three-dimensional dispersive media in the form of solitons localized in space and time. As is known, collapse does not take place in these models, which is why the solitons may be stable. The general solution is obtained in an approximate analytical form by means of a variational approach, which also allows the stability of the solutions to be predicted. Then, we directly simulate the two-dimensional case, taking the initial configuration as suggested by the variational approximation. We thus demonstrate that spatiotemporal solitons indeed exist and are stable. Furthermore, they are not, in the general case, equivalent to the previously known cylindrical spatial solitons. Direct simulations generate solitons with some internal oscillations. However, these oscillations neither grow nor do they exhibit any significant radiative damping. Numerical solutions of the stationary version of the equations produce the same solitons in their unperturbed form, i.e., without internal oscillations. Strictly stable solitons exist only if the system has anomalous dispersion at both the fundamental harmonic and second harmonic (SH), including the case of zero dispersion at SH. Quasistationary solitons, decaying extremely slowly into radiation, are found in the presence of weak normal dispersion at the second-harmonic frequency.
Resumo:
Background: Concurrent autoimmune disorders (CAIDs) have been shown to occur in 22% to 34% of the patients with autoimmune hepatitis (AIH). Their presence has been linked to female gender, older age, and to certain HLA antigens, namely HLA-A11. DRB1*04, and DRB4*01. Aims: To assess the frequency and nature of CAID in Brazilian patients with AIH types 1 (AIH-1) and 2 (AIH-2) and to investigate the influence of age, gender, and genetic background in their occurrence. Patients and Methods: The presence and nature of CAID was studied in 143 patients [117 females, median age 11 (1.3 to 69)] with AIH-1 (n = 125) and AIH-2 (n = 28). HLA typing and tumor necrosis factor a gene promoter and exon I cytotoxic T lymphocyte associated antigen 4 (CTLA-4) gene polymorphisms were determined by polymerase chain reaction-based techniques. Results: The frequency of CAID was similar in patients with AIH-1 (14%) and AIH-2 (18%), but their nature was shown to vary. Arthritis was seen in half of the patients (n = 8) with CAID and AIH-1 and in none of those with AIH-2. Subjects with AIH-1 and CAID were shown to be older [24 (1.3 to 6 1) vs. 11 (1.3 to 69) y P = 0.02] and to have more often circulating antinuclear antibody (76% vs. 40%, P = 0.008) and less frequently antiactin antibodies (33% vs. 75%, P = 0.008) when compared with their counterparts without CAID. No particular HLA-DR and DQ alleles, as well as tumor necrosis factor a and CTLA-4 genotypes, were associated with CAID. Conclusions: The nature, but not the frequency, of CAID was shown to vary in AIH-1 and AIH-2. In subjects with AIH-1, CAID was linked to older subjects and to the presence of antinuclear antibody. No predisposition to CAID was associated to HLA-DRB1*04 or DDB4*01 alleles. The observed lower frequency of CAID could be attributed to the lower age of disease onset in Brazilians and to differences in HLA-encoded susceptibility to AIH-1 observed in South America.
Resumo:
In order to separate the effects of experience from other characteristics of word frequency (e.g., orthographic distinctiveness), computer science and psychology students rated their experience with computer science technical items and nontechnical items from a wide range of word frequencies prior to being tested for recognition memory of the rated items. For nontechnical items, there was a curvilinear relationship between recognition accuracy and word frequency for both groups of students. The usual superiority of low-frequency words was demonstrated and high-frequency words were recognized least well. For technical items, a similar curvilinear relationship was evident for the psychology students, but for the computer science students, recognition accuracy was inversely related to word frequency. The ratings data showed that subjective experience rather than background word frequency was the better predictor of recognition accuracy.
Resumo:
to test the ability of frequency-doubling technology (FDT) perimetry to detect dysthyroid optic neuropathy (DON). Fifteen eyes of 15 patients with DON and 15 healthy control eyes were studied. Eligible eyes had a diagnosis of DON based on visual field abnormalities on standard automated perimetry and had visual acuity better than 20/30. FDT testing was performed using both the C-20-5 screening test and the C-20 full-threshold test. Normal and DON eyes were compared with regard to FDT mean sensitivity. Sensitivity ranges were 40.0%-86.7% for the screening test, and 53.3%-100.0% (total deviation) and 20.0-93.3 (pattern deviation) for the C-20 threshold test. The corresponding specificity ranges were 86.7-100.0, 33.3-93.3, and 26.7-100.0, respectively. The best sensitivity/specificity ratios were for one abnormal point depressed < 5% in the screening test (86.7%/86.7%), one point depressed < 1% in the total deviation analysis (80.0%/86.7%), and one point depressed < 2% in the pattern deviation analysis (80.0%/86.7%). DON eyes presented significantly lower than normal average sensitivity in the central, pericentral, and peripheral areas. FDT perimetry is a useful screening tool for DON in eyes with normal or only slightly reduced visual acuity.
Cross-cultural adaptation and validation of a Brazilian Portuguese version of the chronic pain grade
Resumo:
To verify the reliability and validity of a Brazilian Portuguese version of the chronic pain grade (CPG-Br). Cultural adaptation was made in accordance with established guidelines, with modifications aiming at improving this process. Adaptations were made based on interviews with 45 chronic pain patients from So Paulo city. Validation was studied by concurrent application of the short-form-36 health survey (SF-36) and other questionnaires to 283 participants with chronic pain from the general population. Temporal stability was verified by a second application to 131 individuals. Factor analysis resulted in a two-factor solution with factors named characteristic pain intensity and activity limitation due to pain. Alpha coefficients of 0.78 and 0.70 and intraclass correlation coefficients of 0.76 and 0.72 for each factor indicated good internal consistency and temporal stability. Significant correlations between CPG-Br and SF-36, Roland-Morris disability questionnaire and neck disability index scores were noted. A consistent linear trend was also observed between pain grades and SF-36 scores. Frequency of use of pain medications and of pain-related medical visits increased with pain grade. This Brazilian Portuguese version of the chronic pain grade, tested on a sample of the Brazilian population, demonstrated good reliability and validity.
Resumo:
Olm MA, Kogler JE Jr, Macchione M, Shoemark A, Saldiva PH, Rodrigues JC. Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images. J Appl Physiol 111: 295-302, 2011. First published May 5, 2011; doi:10.1152/japplphysiol.00629.2010.-Ciliary beat frequency (CBF) measurements provide valuable information for diagnosing of primary ciliary dyskinesia (PCD). We developed a system for measuring CBF, used it in association with electron microscopy to diagnose PCD, and then analyzed characteristics of PCD patients. 1 The CBF measurement system was based on power spectra measured through digital imaging. Twenty-four patients suspected of having PCD (age 1-19 yr) were selected from a group of 75 children and adolescents with pneumopathies of unknown causes. Ten healthy, nonsmoking volunteers (age >= 17 yr) served as a control group. Nasal brush samples were collected, and CBF and electron microscopy were performed. PCD was diagnosed in 12 patients: 5 had radial spoke defects, 3 showed absent central microtubule pairs with transposition, 2 had outer dynein arm defects, 1 had a shortened outer dynein arm, and 1 had a normal ultrastructure. Previous studies have reported that the most common cilia defects are in the dynein arm. As expected, the mean CBF was higher in the control group (P < 0.001) and patients with normal ultrastructure (P < 0.002), than in those diagnosed with cilia ultrastructural defects (i.e., PCD patients). An obstructive ventilatory pattern was observed in 70% of the PCD patients who underwent pulmonary function tests. All PCD patients presented bronchial wall thickening on chest computed tomography scans. The protocol and diagnostic techniques employed allowed us to diagnose PCD in 16% of patients in this study.
Resumo:
To evaluate the effects of frequency and inspiratory plateau pressure (Pplat) during recruitment manoeuvres (RMs) on lung and distal organs in acute lung injury (ALI). We studied paraquat-induced ALI rats. At 24 h, rats were anesthetized and RMs were applied using continuous positive airway pressure (CPAP, 40 cmH(2)O/40 s) or three-different sigh strategies: (a) 180 sighs/h and Pplat = 40 cmH(2)O (S180/40), (b) 10 sighs/h and Pplat = 40 cmH(2)O (S10/40), and (c) 10 sighs/h and Pplat = 20 cmH(2)O (S10/20). S180/40 yielded alveolar hyperinflation and increased lung and kidney epithelial cell apoptosis as well as type III procollagen (PCIII) mRNA expression. S10/40 resulted in a reduction in epithelial cell apoptosis and PCIII expression. Static elastance and alveolar collapse were higher in S10/20 than S10/40. The reduction in sigh frequency led to a protective effect on lung and distal organs, while the combination with reduced Pplat worsened lung mechanics and histology.