The efficiency of a new procedure for the digestion of natural waters, based on a microwave-activated photochemical reactor was evaluated in this work. Fluorescence spectra showed a 99% reduction in the emission of a 40 mg L-1 humic acid solution after 15 min of UV irradiation. In the presence of H2O2, only 3 min were necessary to accomplish a reduction of almost 100% in the emission and 6 min to reduce the concentration of dissolved organic carbon by 95%. The copper recovery from synthetic samples containing commercial humic acid, from soil suspensions, as well as from natural waters varied between 91.5 and 106.6%. The digestion of dissolved and unfiltered samples was successfully accomplished in 6 and 12 min, respectively. No contaminations or sample losses were observed. Results of copper speciation in natural waters showed that this metal is predominantly bound to natural ligands. Only 3-6% of the total recoverable copper is present in the labile form.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of factorial design was evaluated for optimization of focused-microwave-assisted digestion of bean samples. Calcium, Fe, Mg, Mn and Zn percentual recoveries were determined in digestates after focused-microwave-assisted digestion according to factorial design procedures. A cavity microwave digestion was carried out to certify the elemental compositions obtained. The accuracy was checked using a standard reference material, the NIST SRM 8433 - Corn Bran. Results are in agreement with certified values at the 95% confidence limit when the Student t-test was used. Volumes of nitric and sulfuric acid, temperature, and the interplay between HNO3 and H2SO4 initial volumes were significant variables according to P-values in the analysis of variance (ANOVA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanism and applications of the Fenton reaction assisted by iron-reducing phenolic compounds (IRPC) is reviewed. The presence of IRPC leads to the formation of a larger number of free radicals. The relationship between the redox potential and the IRPC structure is discussed. The effect of humic substances in the degradation of xenobiotics is also included, since these substances are able to reduce metallic ions. The natural occurrence of Fe3+/H2O2/IRPC in wood biodegradation processes, as well as their application is also discussed. The review concludes with the advantages of the Fe3+/H2O2/IRPC systems and some considerations for further process optimization and their applications at industrial levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La Direcció General d’Indústria té com a principal finalitat el control de les instal•lacions i de diferents activitats de l’àmbit industrial; exerceix aquesta funció mitjançant la tramitació de documentacions tècniques i la inspecció. Com tota Administració Pública, es troba en un entorn molt dinàmic, on només les empreses més competitives poden subsistir i els ciutadans tenen noves necessitats molt diferents de les de fa un temps. Ambdós, empreses i ciutadans, exigeixen serveis de qualitat a un sector públic que no té altra alternativa que caminar en la mateixa direcció. L’objectiu d’aquest treball és planificar una sèrie d’accions estratègiques que permetran la millora dels serveis oferts a fi de complir amb les expectatives de la ciutadania. S’ha realitzat una anàlisi interna i de l’entorn de l’organització, el resultat de la qual ha estat la detecció d’una sèrie de punts de millora. A continuació s’ha definit una pla operatiu de qualitat, emmarcat dins del segon Pla Estratègic de Qualitat del Govern de les Illes Balears, amb tres propostes d’actuació: la separació de funcions, la tramitació ràpida d’expedients i el pla de formació. Les propostes esmentades constitueixen les bases d’una nova unitat orgànica (Oficina de Tramitació Ràpida), el model organitzatiu de la qual queda definit en els diferents apartats del treball. Igualment, s’hi descriu el procés de posada en funcionament dels distints procediments que es vagin adaptant al nou sistema i la planificació dels treballs a dur a terme, que seguiran el cicle de la qualitat de Deming, és a dir, planificar, fer, verificar i actuar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present work was to develop and optimize a method for determination of bioavailable phosphorus in samples of feces and fish feed using ultrasound extraction and subsequent quantification by visible spectrophotometry. Using as extractor solution HNO3 0.50 mol L-1, the great conditions of extraction established were: sample mass - 100 mg, samples granulometry - < 60 µm, sonification time - five cycles of 40 s and ultrasound potency - 136 W. The proposed method was applied in studies of digestibility of this nutrient in different feeds used in diets of juvenile of Nile tilapia.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biofuel was prepared from acid aqueous fraction (pH = 2) of bio-oil produced by fast pyrolysis (Bioware Technology) of lignocellulosic biomass (sugar cane residue) and tested in blends (2, 5, 10 e 20% v/v) with gasoline type C (common) marketed in Brazil. The specification tests made in the Refinery President Getúlio Vargas (PETROBRAS) showed increasing in the octane number (MON) and antiknock index (AKI) with reduction in the residue generation during the combustion. The physicochemical characteristics of the biofuel were similar that combustible alcohol allowing its use as gasoline additive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the optimization of the microwave-assisted hydrothermal synthesis of [Zn(BDC)(H2O)2]n . The reactions were carried out at the fixed temperature of 120 ºC for 10, 20, 30 and 40 min. Pure crystalline [Zn(BDC)(H2O)2]n was obtained in high yield (ca. 90%) with a reaction time of 10 min. The phase obtained and its purity was confirmed by Rietveld refinement, with a final value for Rwp/Rexp equal to 1.48. Increased reaction times (20, 30 and 40 min) favored the formation of unwanted by products, resulting in mixtures of several crystalline phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid ultra-performance liquid chromatographic method for determination of oseltamivir in capsules was developed and validated. The mobile phase consisted of 5 mmol/L triethylammonium buffer (pH 3.0) and acetonitrile (70:30, v/v). Separation was performed in a Hypersil Gold® column, with octylsilil as stationary phase (100 x 2.1 mm, p.d. 1.9 µm). Chromatography run time was 1.2 min. The method presented adequate specificity, linearity, precision, ruggedness and accuracy and was adequate for determination of oseltamivir in capsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave synthesis is considered a breakthrough in the field of chemistry due to its benefits over conventional heating methods. We describe, for the first time, the total synthesis of phenytoin adapted for a microwave reactor, proposed as an experiment for undergraduate courses. When carried out with microwaves, the synthetic route provided phenytoin in 6 min and 30 s, while for conventional heating the total time was 170 min. The experiment also involves rapid identification of compounds by TLC, ¹H NMR, FT-IR and melting points determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast analytical method for determination of hydroquinone in pharmaceutical formulations employing batch injection analysis (BIA) with amperometric detection using a boron-doped diamond electrode is described. The supporting electrolyte was a 0.1 mol L-1 H2SO4 solution (the single reagent used for analysis). The method showed good repeatability (RSD of 0.45%, n=20), wide linear range (from 10 to 2000 µmol L-1, R=0.9999), low detection limit (0.016 µmol L-1) and satisfactory recovery values (91-96%). Accuracy of the method was evaluated by comparative analyses using high-performance liquid-chromatography. The ability to replace the electronic pipette by disposable syringes (injection procedure) in BIA systems was also shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compulsory in Brazil, toy certification aims to prevent possible risks in toy use. The Brazilian National Institute of Metrology (INMETRO) establishes the maximum concentration of toxic elements (TE) that may be present in toys. This study evaluates the presence of TE in different crayons, gouache and modeling clays using X-ray fluorescence. This technique is fast, has low operating cost and minimum sample pretreatment, resulting in a clean procedure without reagent consumption and waste generation. Bromine (in gouache) and Barium (in crayons) were the only potentially TE identified in the samples studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports a practical case based on the use of microwave-assisted derivatization and GC-MS for the analysis of glucose. Using two different methods for derivatization, one reference compound and the calculated dipole moment, all the isomers of glucose were identified. Identification was corroborated for the assignment of structures using the mass spectra. With this work, students are expected to associate different types of information to solve the complex problem of the analysis of glucose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure for ultrasound-assisted extraction and colorimetric determination of iron in soil samples was developed. The iron concentration in the analyzed samples was determined by the colorimetric method and the results compared with inductively coupled plasma mass spectrometry (ICP-MS). Fifteen soil samples were analyzed and the iron concentration results compared with those obtained by ICP-MS using microwave-assisted sample digestion. The proposed procedure showed good efficiency for iron extraction and the results obtained by colorimetric determination exhibited good agreement with ICP-MS. Moreover, ultrasound-assisted extraction and colorimetric determination is a simple, fast and low-cost procedure for application in routine analysis.