974 resultados para Electronic detector readout concepts (gas, liquid)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes preliminary work on the generation of synthesis gas from water electrolysis using graphite electrodes without the separation of the generated gases. This is an innovative process, that has no similar work been done earlier. Preliminary tests allowed to establish correlations between the applied current to the electrolyser and flow rate and composition of the generated syngas, as well as a characterisation of generated carbon nanoparticles. The obtained syngas can further be used to produce synthetic liquid fuels, for example, methane, methanol or DME (dimethyl ether) in a catalytic reactor, in further stages of a present ongoing project, using the ELECTROFUEL® concept. The main competitive advantage of this project lies in the built-in of an innovative technology product, from RE (renewable energy) power in remote locations, for example, islands, villages in mountains as an alternative for energy storage for mobility constraints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presented at Faculdade de Ciências e Tecnologias, Universidade de Lisboa, to obtain the Master Degree in Conservation and Restoration of Textiles

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Física

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation to obtain the Doctoral degree in Physics Engineering

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cryogen-free superconducting magnet systems have become popular during the last two decades for the simple reason that with the use of liquid helium is rather cumbersome and is a scarce resource. Some available CFMS uses a mechanical cryocooler as cold source of the superconductor magnet. However, the cooling of the sample holder is still made through an open circuit of helium. A thermal management of a completely cryogen-free system is possible to be implemented by using a controlled gas gap heat switch (GGHS) between the cryocooler and the variable temperature insert (VTI). This way it would eliminate the helium open circuit. Heat switches are devices that allow to toggle between two distinct thermal states (ON and OFF state). Several cryogenic applications need good thermal contact and a good thermal insulation at different stages of operation. A versatile GGHS was designed and built with a 100 mm gap and tested with helium as exchange gas. An analytic thermal model was developed and a good agreement with the experimental data was obtained. The device was tested on a crycooler at 4 to 80 K ranges. A 285 mW/K thermal conductance was measured at ON state and 0.09 mW/K at OFF. 3000 ON/OFF thermal conductance ratio was obtained at 4 K with helium.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work presented in this thesis aims at developing a new separation process based on the application of supported magnetic ionic liquid membranes, SMILMs, using magnetic ionic liquids, MILs. MILs have attracted growing interest due to their ability to change their physicochemical characteristics when exposed to variable magnetic field conditions. The magnetic responsive behavior of MILs is thus expected to contribute for the development of more efficient separation processes, such as supported liquid membranes, where MILs may be used as a selective carrier. Driven by the MILs behavior, these membranes are expected to switch reversibly their permeability and selectivity by in situ and non-invasive adjustment of the conditions (e.g. intensity, direction vector and uniformity) of an external applied magnetic field. The development of these magnetic responsive membrane processes were anticipated by studies, performed along the first stage of this PhD work, aiming at getting a deep knowledge on the influence of magnetic field on MILs properties. The influence of the magnetic field on the molecular dynamics and structural rearrangement of MILs ionic network was assessed through a 1H-NMR technique. Through the 1H-NMR relaxometry analysis it was possible to estimate the self-diffusion profiles of two different model MILs, [Aliquat][FeCl4] and [P66614][FeCl4]. A comparative analysis was established between the behavior of magnetic and non-magnetic ionic liquids, MILs and ILs, to facilitate the perception of the magnetic field impact on MILs properties. In contrast to ILs, MILs show a specific relaxation mechanism, characterized by the magnetic dependence of their self-diffusion coefficients. MILs self-diffusion coefficients increased in the presence of magnetic field whereas ILs self-diffusion was not affected. In order to understand the reasons underlying the magnetic dependence of MILs self-diffusion, studies were performed to investigate the influence of the magnetic field on MILs’ viscosity. It was observed that the MIL´s viscosity decreases with the increase of the magnetic field, explaining the increase of MILs self-diffusion according to the modified Stokes- Einstein equation. Different gas and liquid transport studies were therefore performed aiming to determine the influence of the magnetic behavior of MILs on solute transport through SMILMs. Gas permeation studies were performed using pure CO2 andN2 gas streams and air, using a series of phosphonium cation based MILs, containing different paramagnetic anions. Transport studies were conducted in the presence and absence of magnetic field at a maximum intensity of 1.5T. The results revealed that gas permeability increased in the presence of the magnetic field, however, without affecting the membrane selectivity. The increase of gas permeability through SMILMs was related to the decrease of the MILs viscosity under magnetic field conditions.(...)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

tThis work is devoted to the investigation of zirconium oxynitride (ZrOxNy) films with varied opticalresponses prompted by the variations in their compositional and structural properties. The films wereprepared by dc reactive magnetron sputtering of Zr, using Ar and a reactive gas mixture of N2+ O2(17:3).The colour of the films changed from metallic-like, very bright yellow-pale and golden yellow, for low gasflows to red-brownish for intermediate gas flows. Associated to this colour change there was a significantdecrease of brightness. With further increase of the reactive gas flow, the colour of the samples changedfrom red-brownish to dark blue or even to interference colourations. The variations in composition dis-closed the existence of four different zones, which were found to be closely related with the variationsin the crystalline structure. XRD analysis revealed the change from a B1 NaCl face-centred cubic zirco-nium nitride-type phase for films prepared with low reactive gas flows, towards a poorly crystallizedover-stoichiometric nitride phase, which may be similar to that of Zr3N4with some probable oxygeninclusions within nitrogen positions, for films prepared with intermediate reactive gas flows. For highreactive gas flows, the films developed an oxynitride-type phase, similar to that of -Zr2ON2with someoxygen atoms occupying some of the nitrogen positions, evolving to a ZrO2monoclinic type structurewithin the zone where films were prepared with relatively high reactive gas flows. The analysis carriedout by reflected electron energy loss spectroscopy (REELS) revealed a continuous depopulation of thed-band and an opening of an energy gap between the valence band (2p) and the Fermi level close to 5 eV.The ZrN-based coatings (zone I and II) presented intrinsic colourations, with a decrease in brightness anda colour change from bright yellow to golden yellow, red brownish and dark blue. Associated to thesechanges, there was also a shift of the reflectivity minimum to lower energies, with the increase of thenon-metallic content. The samples lying in the two last zones (zone III, oxynitride and zone IV, oxide films)revealed a typical semi-transparent-optical behaviour showing interference-like colourations only dueto the complete depopulation of the d band at the Fermi level. The samples lying in these zones presentedalso an increase of the optical bandgap from 2 to 3.6 eV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT Objectives To compare and discuss the objects of awareness in Alzheimer’s disease (AD): awareness of cognitive deficits, of functional activities, of social-emotional functioning and behavioral impairment. Methods A search in the PsycINFo, Pilots, PubMed/Medline and ISI electronic databases according to Prisma methodology was performed. We included studies about awareness in people with AD published between 2010 and 2015, with the combination of keywords: “Alzheimer AND awareness of deficits”, “Alzheimer AND anosognosia”, “Alzheimer AND insight”, “dementia AND awareness of deficits”, “dementia AND anosognosia”, “dementia AND insight”. The articles were categorized according to the specific object of awareness. Results Seven hundred and ten records were identified and, after application of the exclusion criteria, 191 studies were retrieved for potential use. After excluding the duplicates, 46 studies were included. Most studies assessed the cognitive domain of awareness, followed by the functional, social-emotional, and behavioral impairment domains. Memory deficits were not sufficient to explain impaired awareness in AD. Longitudinal studies did not find discrepancies between patients and caregivers’ reports, indicating that awareness is not related to cognition. Conflicting findings were observed, including the relation between awareness, mood, severity of disease, and personal characteristics. Conclusions The studies show lack of conceptual consensus and significant methodological differences. The inclusion of samples without differentiation of dementia etiology is associated to symptomatic differences, which affect awareness domains. Awareness in AD is a complex and multidimensional construct. Different objects elicit different levels of awareness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Liquid separation efficiency, liquid penetration, modeling, arrays of temperature, distribution, fluidized bed, two-phase-nozzle

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recerca realitzada durant el periode Gener 2006-Abril 2007, a la Facultat de Farmàcia de la Universitat de Barcelona sota la direcció de la Dra. M. Carmen López Sabater. La nutrició durant els primers anys de vida té una enorme importància, amb repercussions en el creixement i desenvolupament del nen i en les possibles malalties futures. Tenint en compte que la llet materna és l’aliment ideal per al nadó durant els primers sis mesos de vida, és important conéixer la composició nutricional de la mateixa i la seva evolució al llarg de la lactància (calostre, llet de transició i madura). La llet conté nutrients majoritaris (proteïnes, carbohidrats i lípids) i nutrients minoritaris, com vitamines i minerals. S'ha desenvolupat i validat un mètode per a la determinació d'àcids grassos (AG) i Àcid Linoleic Conjugat (CLA) en llet materna per Cromatografia de Gasos "fast" (fast-GC), permetent reduir el temps d'anàlisi considerablement en comparació amb els mètodes utilitzats fins el moment. La repetibilitat i reproducibilitat trobades han estat bones, amb coeficients de variació inferiors al 10% en tots els casos. L'aplicació a 6 mostres de llet materna ha demostrat que es tracta d'un mètode senzill, ràpid, eficient i pràctic per a l'anàlisi rutinari d'un elevat nombre de mostres. També s'ha començat a desenvolupar un mètode per a l'anàlisi dels anàlegs de tocoferol de la llet materna, degut a l'interès de la vitamina E com a antioxidant natural. És un mètode per Cromatografia Líquida d'Ultra Resolució (UPLC) amb detecció per Fluorescència (FD) i per Photodiode Array (PDA) que permet treballar amb quantitats de mostra petites mantenint o inclús millorant la sensibilitat i reduint el temps d’anàlisi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Durant les darreres dècades, i degut, principalment, a un canvi en els hàbits alimentaris, hi ha hagut un augment a nivell mundial de malalties cròniques (l’obesitat, malalties cardiovasculars, etc.). En els països mediterranis hi ha menys incidència d’aquestes malalties i sembla ser que això es deu a l’anomenada dieta mediterrània. La dieta mediterrània es caracteritza per una combinació d’oli d’oliva com a grassa principal, verdures, hortalisses i fruites en abundància, lleguminoses, fruits secs, formatges i iogurt, peix, pa, pasta, cereals i els seus derivats i un consum moderat de vi i carns. Aquest model alimentari, ric en tocoferols, fitosterols i fitoestanols que ajuden a reduir el contingut de colesterol en sang, fa que en les poblacions mediterrànies hi hagi menys incidència de malalties cardiovasculars. Aquests compostos inhibeixen el deteriorament oxidatiu dels olis, actuen com agent antipolimerització per olis de fregir. Tenen capacitat de reduir els nivells de colesterol, evitant la incidència de malalties cardiovasculars. Els fitoesterols y fitoestanols es poden trobar en forma lliure o esterificada amb àcids grassos, àcids fenòlics i glucosa. Els objectius d’ aquest treball han estat, primer en el desenvolupament de mètodes d'anàlisi ràpids, fiables i robusts dels tocoferols, fitoesterols i fitoestanols i la seva aplicació en fruits sec, oli de segó, oli de pinyol de raïm i productes que els continguin. El primer mètode va estar basat en la cromatografía líquida (HPLC-DAD) amb extracció en fase sòlida (SPE) com tècnica alternativa a la saponificació para la determinació de fitoesterols lliures. Aquest mètode va estar aplicada a mostres de bombons que contenia fitoesterols. El segon mètode va estar basat en la cromatografia de gasos (GCFID) amb aponificació i SPE per quantificar fitoesterols i fitoestanols lliures, esterificats i totals. En els documents annexos es descriuen a profunditat els mètodes desenvolupats.