943 resultados para Electrical Conductivity
Resumo:
Besides its importance in the coffee tree nutrition, there is almost no information relating zinc nutrition and bean quality. This work evaluated the effect of zinc on the coffee yield and bean quality. The experiment was conducted with Coffea arabica L. in "Zona da Mata" region, Minas Gerais, Brazil. Twelve plots were established at random with 4 competitive plants each. Treatments included plants supplemented with zinc (eight plots) and control without zinc supplementation (four plots). Plants were subjected to two treatments: zinc supplementation and control. Yield, number of defective beans, beans attacked by berry borers, bean size, cup quality, beans zinc concentration, potassium leaching, electrical conductivity, color index, total tritable acidity, pH, chlorogenic acids contents and ferric-reducing antioxidant activity of beans were evaluated. Zinc positively affected quality of coffee beans, which presented lower percentage of medium and small beans, lower berry borer incidence, lower potassium leaching and electrical conductivity, higher contents of zinc and chlorogenic acids and higher antioxidant activity in comparison with control beans.
Resumo:
The electrical conductivity of leachates from imbibing seeds has been used as a vigor test for several species. The adaptation of this methodology to different species requires knowledge on the leaching kinetics of electrolytes. For Brazilwood seeds, the classic method was not satisfactory and rapid tests are essential because they have low storage capacity at room temperature. Leaching kinetics during seed imbibition is a function of physiological quality, presence or absence of seed coat, imbibing temperature and the initial moisture content of seed. In this study, the electrolyte leaching rate of six different categories of seeds, from two regions, was evaluated in seeds with and without seed coat and incubated with different moisture contents and at different temperatures. The results showed that the electrolyte leaching rate in Brazilwood seeds is independent of the physiological quality, the presence or absence of seed coat and imbibition temperature, but these factors changed the total amount of electrolytes leached. The leaching rate increased in the first few minutes of imbibition, suggesting that the adjustment of the methodology must consider the reduction in imbibition time, reduction in temperature, use of a controlled and slower pre-imbibition, and replacement of the imbibition solution after the first few minutes.
Resumo:
ABSTRACTThis study aimed to evaluate the influence of foliar fertilizer doses containing Mn of phenological stages of suggested application in RR soybeans, to recover management damages with glyphosate at postemergence application on seed vigor in post-harvest and post six months storage. The seeds originated from a field experiment conducted , which included two applications of glyphosate, concomitant with foliar fertilizer in growth stages V4 and V6, with 0.00, 113.50 and 227.00 mg ha-1doses of Mn2+. Germination, GSI (Germination Speed Index), electrical conductivity tests and the first count of seeds were conducted. The application of Mn did not affect the physiological quality of RR soy in postharvest. However, in post-storage, higher doses of Mn had a negative effect on tests of abnormal seedlings, GSI and electrical conductivity. The applications of Mn, regardless of the developmental stage, did not interfere in the germination and first count tests, with and without storage. The electrical conductivity test showed a higher correlation with the seed germination test in the post-harvest treatment.
Resumo:
Tese de Doutoramento, Geologia (Hidrogeologia), 17 de Dezembro de 2013, Universidade dos Açores.
Resumo:
The magnetic and electrical properties of Ni implanted single crystalline TiO2 rutile were studied for nominal implanted fluences between 0.5 x 10(17) cm(-2) and 2.0 x 10(17) cm(-2) with 150 keV energy, corresponding to maximum atomic concentrations between 9 at% and 27 at% at 65 nm depth, in order to study the formation of metallic oriented aggregates. The results indicate that the as implanted crystals exhibit superparamagnetic behavior for the two higher fluences, which is attributed to the formation of nanosized nickel clusters with an average size related with the implanted concentration, while only paramagnetic behavior is observed for the lowest fluence. Annealing at 1073 K induces the aggregation of the implanted nickel and enhances the magnetization in all samples. The associated anisotropic behavior indicates preferred orientations of the nickel aggregates in the rutile lattice consistent with Rutherford backscattering spectrometry-channelling results. Electrical conductivity displays anisotropic behavior but no magnetoresistive effects were detected. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Throughout the world, epidemiological studies were established to examine the relationship between air pollution and mortality rates and adverse respiratory health effects. However, despite the years of discussion the correlation between adverse health effects and atmospheric pollution remains controversial, partly because these studies are frequently restricted to small and well-monitored areas. Monitoring air pollution is complex due to the large spatial and temporal variations of pollution phenomena, the high costs of recording instruments, and the low sampling density of a purely instrumental approach. Therefore, together with the traditional instrumental monitoring, bioindication techniques allow for the mapping of pollution effects over wide areas with a high sampling density. In this study, instrumental and biomonitoring techniques were integrated to support an epidemiological study that will be developed in an industrial area located in Gijon in the coastal of central Asturias, Spain. Three main objectives were proposed to (i) analyze temporal patterns of PM10 concentrations in order to apportion emissions sources, (ii) investigate spatial patterns of lichen conductivity to identify the impact of the studied industrial area in air quality, and (iii) establish relationships amongst lichen conductivity with some site-specific characteristics. Samples of the epiphytic lichen Parmelia sulcata were transplanted in a grid of 18 by 20 km with an industrial area in the center. Lichens were exposed for a 5-mo period starting in April 2010. After exposure, lichen samples were soaked in 18-MΩ water aimed at determination of water electrical conductivity and, consequently, lichen vitality and cell damage. A marked decreasing gradient of lichens conductivity relative to distance from the emitting sources was observed. Transplants from a sampling site proximal to the industrial area reached values 10-fold higher than levels far from it. This finding showed that lichens reacted physiologically in the polluted industrial area as evidenced by increased conductivity correlated to contamination level. The integration of temporal PM10 measurements and analysis of wind direction corroborated the importance of this industrialized region for air quality measurements and identified the relevance of traffic for the urban area.
Resumo:
Dissertação de Mestrado, Engenharia e Gestão de Sistemas de Água, 30 de Setembro de 2015, Universidade dos Açores.
Resumo:
The temperature dependence of electrical conductivity and the photoconductivity of polycrystalline Cu2ZnSnS4 were investigated. It was found that at high temperatures the electrical conductivity was dominated by band conduction and nearest-neighbour hopping. However, at lower temperatures, both Mott variable-range hopping (VRH) and Efros–Shklovskii VRH were observed. The analysis of electrical transport showed high doping levels and a large compensation ratio, demonstrating large degree of disorder in Cu2ZnSnS4. Photoconductivity studies showed the presence of a persistent photoconductivity effect with decay time increasing with temperature, due to the presence of random local potential fluctuations in the Cu2ZnSnS4 thin film. These random local potential fluctuations cannot be attributed to grain boundaries but to the large disorder in Cu2ZnSnS4.
Resumo:
Following a prescribed fire in a Pinus pinaster forest site located in the north-west Portugal, monitoring of any changes in selected soil characteristics and soil hydrology was undertaken to assess the effects of burning on the following: pH, electrical conductivity, water content, organic carbon and porosity. Thirty plots were established on a regular grid. At each sample plot before and after the fire, samples were collected (disturbed samples from depths of 0-1cm and 1-5cm; undisturbed core samples from 0-5cm). The results indicate that there was no measurable impact on the properties of the soil following this carefully conducted prescribed fire. The fire only affected the litter layer, as intended. Confirmation of this minimal impact on the soil was provided by regrowth of grasses and herbs already occurring two months after the fire. The implication is, therefore, that provided this wildfire-risk reduction strategy is carried out under existing strict guidelines, any impact on soil quality will be minimal.
Resumo:
The prescribed fire is a technique that is often used, it has several advantages. Pedological and hydropedological techniques were tested to assess the prescribed fire changes may cause in soils. This work was performed in Tresminas area (Vila Pouca de Aguiar, Northern Portugal), during February and March 2011. In the present study we applied several techniques. For the field sampling was followed the ISO 10381-1[1], ISO 10381-2[2], and FAO rules [3], as well as were used a grid with 17 points for measuring the soil parameters. During the fire, we have tried to check, with the assistance of the Portuguese Forestry Authority, some important parameters such as, the propagation speed, the size of the flame front and the intensity of energy emitted per unit area. Before the fire, was collected carefully soil disturbed and undisturbed samples for laboratory analysis, and measured soil water content; we also have placed four sets of thermocouples for measuring soil temperature. After the fire, were collected the thermocouples and new soil samples; the water content were measured in the soil and collected ashes. In the laboratory, after preparing and sieving the samples, were determined the soil particle size. The soil pH and electrical conductivity in water was also determined. The total carbon (TC) and inorganic carbon (IC)[4] was measured by a Shimadzu TOC-Vcsn. The water content in soil has not varied significantly before and after the fire, as well as soil pH and soil electrical conductivity. The TC and IC did not change, which was expected, since the fire not overcome the 200° C. Through the various parameters, we determined that the prescribed fire didn’t affect the soil. The low temperature of the fire and its rapid implementation that lead to the possible adverse effects caused by the wild fire didn’t occurred.
Resumo:
Cubic cobalt nitride films were grown onto different single crystalline substrates Al2O3 (0 0 0 1) and (1 1 View the MathML source 0), MgO (1 0 0) and (1 1 0) and TiO2 (1 0 0) and (1 1 0). The films display low atomic densities compared with the bulk material, are ferromagnetic and have metallic electrical conductivity. X-ray diffraction and X-ray absorption fine structure confirm the cubic structure of the films and with RBS results indicate that samples are not homogeneous at the microscopic scale, coexisting Co4+xN nitride with nitrogen rich regions. The magnetization of the films decreases with increase of the nitrogen content, variation that is shown to be due to the decrease of the cobalt density, and not to a decrease of the magnetic moment per cobalt ion. The films are crystalline with a nitrogen deficient stoichiometry and epitaxial with orientation determined by the substrate.
Resumo:
Esta dissertação teve como objetivo fundamental a otimização energética do sistema de refrigeração da máquina de impregnar tela ZELL e, como objetivo adicional, a avaliação da qualidade da água do circuito, justificada pela acentuada degradação dos rolos devido à corrosão provocada pela recirculação da água de arrefecimento. Inicialmente fez-se o levantamento de informações do processo produtivo para caracterizar o funcionamento do sistema de refrigeração, tendo-se selecionado duas telas de poliéster designadas neste estudo por P1 e P2 e, também, uma tela de nylon designada por N. Foram efetuados ensaios, um para cada tela, para a atual temperatura de setpoint da água à saída da torre de arrefecimento (30ºC). Realizou-se outro ensaio para a tela N mas com uma temperatura de setpoint de 37ºC, ao qual se chamou N37. Deste modo, determinou-se as potências térmicas removidas pela água de refrigeração e as potências térmicas perdidas por radiação e por convecção, tendo-se verificado que na generalidade dos rolos as referências P1 e P2 apresentam valores mais elevados. Em termos percentuais, a potência térmica removida pela água de refrigeração nos grupos tratores 1 e 3 e no conjunto de rolos de R1 a R29 corresponde a 48%, 10% e 70%, respetivamente. Com a avaliação às necessidades de arrefecimento da máquina ZELL, confirmou-se que os caudais atuais de refrigeração dos rolos garantem condições, mais que suficientes, de funcionamento dos rolamentos. Assim sendo, fez-se uma análise no sentido da diminuição do caudal total que passou de 10,25 L/s para 7,65 L/s. Considerando esta redução, determinou-se o caudal de ar húmido a ser introduzido na torre de arrefecimento. O valor determinado foi de 4,6 m3ar húmido/s, o que corresponde a uma redução de cerca de 32% em relação ao caudal atual que é de 6,8 m3ar húmido/s. Com os resultados das análises efetuadas à água do circuito de refrigeração, concluiu-se que a água de reposição e a água de recirculação possuem má qualidade para uso na generalidade dos sistemas de refrigeração, principalmente devido aos elevados valores de concentração de ferro e condutividade elétrica, responsáveis pela intensificação da corrosão no interior dos rolos.
Resumo:
O principal objectivo desta dissertação foi avaliar a evolução hidrogeoquímica das águas minerais de Entre‐os‐Rios, para uma melhor compreensão do modelo hidrogeológico conceptual deste sistema hidromineral. Desta forma, foram coligidos diversos dados hidroquímicos, quer das nascentes clássicas (Torre, Curveira, Ardias, Arcos Esquerda e Arcos Direita), quer do furo Barbeitos. Foram compiladas e analisadas oitenta análises hidroquímicas no período 1938‐2012, incluindo características organolépticas (cheiro, cor e turbidez), diversas propriedades físico-químicas (temperatura, pH, condutividade eléctrica, sulfuração, etc), os principais catiões e aniões (bicarbonato, fluoreto, sódio, lítio, etc) e os elementos vestigiários (chumbo, tungsténio, boro, etc). Além disso, foram integrados os dados históricos disponíveis de finais do século XIX e inícios do século XX. Foram igualmente reunidos e discutidos alguns dados isotópicos (oxigénio‐18, deutério e trítio). O recurso hidromineral de Entre‐os‐Rios está condicionado pela litologia e pelas condições tectónicas. As análises químicas revelaram que as águas minerais de Entre‐os‐Rios apresentam uma estabilidade química nos últimos 100 anos. Estas águas são orto‐ a hipertermais, fracamente mineralizadas, de reacção alcalina, sulfídricas, bicarbonatadas sódicas, carbonatadas e muito fluoretadas. Estas características são claramente distintas das águas normais da região. As águas de Entre‐os‐Rios são muito semelhantes às águas minerais de S. Vicente e, em diversos parâmetros, bastante diferentes das águas minerais das Caldas da Saúde. Os dados isotópicos permitiram concluir que as águas de Entre‐os‐Rios têm uma origem meteórica, com um tempo de residência longo no sistema aquífero, e que são, muito provavelmente, submodernas, com uma recarga anterior a 1952. Na região de Entre‐os‐Rios coexistem três sistemas aquíferos, um sistema granítico superficial, livre e um sistema livre a semi‐confinado, ambos com circulação de águas normais, e um sistema aquífero granítico, profundo, confinado, com circulação de água mineral.
Resumo:
The excessive use of pesticides and fertilisers in agriculture has generated a decrease in groundwater and surface water quality in many regions of the EU, constituting a hazard for human health and the environment. Besides, on-site sewage disposal is an important source of groundwater contamination in urban and peri-urban areas. The assessment of groundwater vulnerability to contamination is an important tool to fulfil the demands of EU Directives. The purpose of this study is to assess the groundwater vulnerability to contamination related mainly to agricultural activities in a peri-urban area (Vila do Conde, NW Portugal). The hydrogeological framework is characterised mainly by fissured granitic basement and sedimentary cover. Water samples were collected and analysed for temperature, pH, electrical conductivity, chloride, phosphate, nitrate and nitrite. An evaluation of groundwater vulnerability to contamination was applied (GOD-S, Pesticide DRASTIC-Fm, SINTACS and SI) and the potential nitrate contamination risk was assessed, both on a hydrogeological GIS-based mapping. A principal component analysis was performed to characterised patterns of relationship among groundwater contamination, vulnerability, and the hydrogeological setting assessed. Levels of nitrate above legislation limits were detected in 75 % of the samples analysed. Alluvia units showed the highest nitrate concentrations and also the highest vulnerability and risk. Nitrate contamination is a serious problem affecting groundwater, particularly shallow aquifers, especially due to agriculture activities, livestock and cesspools. GIS-based cartography provided an accurate way to improve knowledge on water circulation models and global functioning of local aquifer systems. Finally, this study highlights the adequacy of an integrated approach, combining hydrogeochemical data, vulnerability assessments and multivariate analysis, to understand groundwater processes in peri-urban areas.
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Mecânica