993 resultados para Catalyst-free


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2’-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The Anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented proposal favored Ab/Ag affinity. The immunosensor design was evaluated by Quartz-Crystal microbalance with Dissipation, Atomic Force Microscopy, Electrochemical Impedance Spectroscopy (EIS) and Square-Wave Voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charged transfer resistance across the electrochemical sep-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from Glucose, Urea and Creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased levels of plasma oxLDL, which is the oxidized fraction of Low Density Lipoprotein (LDL), are associated with atherosclerosis, an inflammatory disease, and the subsequent development of severe cardiovascular diseases that are today a major cause of death in modern countries. It is therefore important to find a reliable and fast assay to determine oxLDL in serum. A new immunosensor employing three monoclonal antibodies (mAbs) against oxLDL is proposed in this work as a quick and effective way to monitor oxLDL. The oxLDL was first employed to produce anti-oxLDL monoclonal antibodies by hybridoma cells that were previously obtained. The immunosensor was set-up by selfassembling cysteamine (Cyst) on a gold (Au) layer (4 mm diameter) of a disposable screen-printed electrode. Three mAbs were allowed to react with N-hydroxysuccinimide (NHS) and ethyl(dimethylaminopropyl)carbodiimide (EDAC), and subsequently incubated in the Au/Cys. Albumin from bovine serum (BSA) was immobilized further to ensure that other molecules apart from oxLDL could not bind to the electrode surface. All steps were followed by various characterization techniques such as electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The analytical operation of the immunosensor was obtained by incubating the sensing layer of the device in oxLDL for 15 minutes, prior to EIS and SWV. This was done by using standard oxLDL solutions prepared in foetal calf serum, in order to simulate patient's plasma with circulating oxLDL. A sensitive response was observed from 0.5 to 18.0 mg mL 1 . The device was successfully applied to determine the oxLDL fraction in real serum, without prior dilution or necessary chemical treatment. The use of multiple monoclonal antibodies on a biosensing platform seemed to be a successful approach to produce a specific response towards a complex multi-analyte target, correlating well with the level of oxLDL within atherosclerosis disease, in a simple, fast and cheap way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A label-free DNA aptamer-based impedance biosensor for the detection of E. coli outer membrane proteins (OMPs) was developed. Two single stranded DNA sequences were tested as recognition elements and compared. The aptamer capture probes were immobilized, with and without 6-mercapto-1-hexanol (MCH) on a gold electrode. Each step of the modification process was characterized by Faradaic impedance spectroscopy (FIS). A linear relationship between the electron-transfer resistance (Ret) and E. coli OMPs concentration was demonstrated in a dynamic detection range of 1 × 10−7–2 × 10−6 M. Moreover, the aptasensor showed selectivity despite the presence of other possible water contaminates and could be regenerated under low pH condition. The developed biosensor shows great potential to be incorporated in a biochip and used for in situ detection of E. coli OMPs in water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microcystin-LR (MC-LR) is a dangerous toxin found in environmental waters, quantified by high performance liquid chromatography and/or enzyme-linked immunosorbent assays. Quick, low cost and on-site analysis is thus required to ensure human safety and wide screening programs. This work proposes label-free potentiometric sensors made of solid-contact electrodes coated with a surface imprinted polymer on the surface of Multi-Walled Carbon NanoTubes (CNTs) incorporated in a polyvinyl chloride membrane. The imprinting effect was checked by using non-imprinted materials. The MC-LR sensitive sensors were evaluated, characterized and applied successfully in spiked environmental waters. The presented method offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cases of extensive damage to the foot, with significant bone loss, it is generally accepted that reconstruction must include bone flaps or grafts either in the emergency setting or subsequently. In this report, we describe the case of an 18-year-old student with an avulsion injury of the dorsum of his right foot. Consequently, he lost most of the soft tissue over the dorsum of the foot and the cuboid, navicular, and cuneiform bones. A latissimus dorsi free flap was used to reconstruct the defect. A functional pseudoarthrosis developed between the remaining bones of the foot, and the patient experienced satisfactory foot function after rehabilitation. For this reason, no additional reconstructive procedure was undertaken. This case suggests that it might be adequate to use the latissimus dorsi muscle flap more liberally than previously reported in the reconstruction of extensive defects of the dorsum of the foot, including cases with significant bone loss. This option could avoid the morbidity and inconvenience of a second surgery and the need to harvest a bone flap or graft.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: Inclusion of antioxidants in topical formulations can contribute to minimize oxidative stress in the skin, which has been associated with photoaging, several dermatosis and cancer. Objective: A Castanea sativa leaf extract with established antioxidant activity was incorporated into a semisolid surfactant-free formulation. The objective of this study was to perform a comprehensive characterization of this formulation. Materials and methods: Physical, microbiological and functional stability were evaluated during 6 months storage at 20 °C and 40 °C. Microstructure elucidation (cryo-SEM), in vitro release and in vivo moisturizing effect (Corneometer® CM 825) were also assessed. Results and discussion: Minor changes were observed in the textural and rheological properties of the formulation when stored at 20 °C for 6 months and the antioxidant activity of the plant extract remained constant throughout the storage period. Microbiological quality was confirmed at the end of the study. Under accelerated conditions, higher modifications of the evaluated parameters were observed. Cryo-SEM analysis revealed the presence of oil droplets dispersed into a gelified external phase. The release rate of the antioxidant compounds (610 ± 70 µgh−0.5) followed Higuchi model. A significant in vivo moisturizing effect was demonstrated, that lasted at least 4 h after product’s application. Conclusion: The physical, functional and microbiological stability of the antioxidant formulation was established. Specific storage conditions should be recommended considering the influence of temperature on the stability. A skin hydration effect and good skin tolerance were also found which suggests that this preparation can be useful in the prevention or treatment of oxidative stress-mediated dysfunctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artigo pretende fazer uma revisão de uma das últimas e inovadoras alternativas cirúrgicas viáveis para a cura da incontinência urinária de esforço feminina, com um sucesso superior a 86%. É uma cirurgia mini invasiva e que induz um suporte da uretra média livre de tensão, muito eficaz. Tem vantagens, poucas complicações, curto tempo operatório e benefícios para a doente no pós-operatório imediato e tardio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A contínua subida dos preços dos combustíveis fósseis tradicionais aliada à crescente pressão por parte de várias instituições mundiais para uma política “verde” no que diz respeito aos combustíveis, levam a um aumento da procura dos biocombustíveis e é neste contexto que surge o biodiesel como um dos principais intervenientes. O biodiesel pode ser definido como um derivado éster monoalquílico de ácidos gordos de cadeia longa proveniente de fontes renováveis como óleos vegetais ou gorduras animais e que apresenta características semelhantes ao diesel de petróleo, podendo ser utilizado sem qualquer problema em motores de ignição por compressão. Este trabalho apresenta como principal objetivo o estudo da aplicação da tecnologia de ultrassons na produção de biodiesel. Foi utilizado neste trabalho como matéria-prima um óleo doméstico usado. Este óleo foi previamente filtrado sendo depois analisado o seu índice de acidez para avaliar o seu teor em ácidos gordos livres. O valor obtido para o índice de acidez do óleo foi de 1,91 mg KOH/g, um valor relativamente baixo permitindo a sua utilização sem ser necessário um tratamento inicial via esterificação para diminuir a acidez do mesmo. Foram realizados três ensaios de reação independentes, o primeiro recorrendo ao método tradicional de produção de biodiesel através de transesterificação e recorrendo a agitação mecânica e aquecimento, o segundo utilizando uma sonda de ultrassons com a potência de 500 W e um terceiro ensaio de reação utilizando uma sonda de ultrassons de 2000 W. Em todas as reações foi utilizada uma proporção de 1:5 de óleo usado e metanol e 0,5 % (em relação á massa de óleo utilizada) de catalisador metilato de sódio. Todas as alíquotas recolhidas durante os ensaios foram analisadas através de cromatografia gasosa de modo a determinar o conteúdo em ésteres presente em cada uma delas. A reação convencional teve uma duração total de 150 minutos e decorreu a uma temperatura de 65ºC e a agitação constante de 500 rpm. Ao longo da reação foram retiradas alíquotas de cerca de 25 ml, que foram tratadas de imediato e posteriormente analisadas de modo a estudar-se o comportamento da reação ao longo do tempo. A percentagem de ésteres metílicos no biodiesel obtida ao fim de 90 minutos foi de 81,3%. Em seguida realizou-se uma reação utilizando uma sonda de ultrassons de 500 W de potência mergulhada num recipiente reacional devidamente isolado com uma rolha de cortiça de modo a minimizar as perdas de metanol por evaporação. O tempo total de reação foi de 90 minutos e foram-se retirando alíquotas de cerca de 25 ml para acompanhar o desenrolar da reação, tendo-se obtido uma percentagem de ésteres metílicos de 85,9% ao fim dos 90 minutos. Foi realizada por fim um terceiro ensaio de reação utilizando uma sonda de 2000 W com uma duração total de 90 minutos, tendo-se obtido resultados pouco satisfatórios (77,7%), provavelmente devido a algum problema operacional relacionado com a sonda de ultrassons utilizada ou devido a uma geometria do reator pouco eficiente. Os produtos resultantes da reação convencional e da reação utilizando a sonda de ultrassons de 500 W, assim como o óleo utilizado como matéria-prima foram caracterizados em termos de índice de acidez, densidade a 15ºC e viscosidade a 40ºC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARYThe survey was carried out to investigate the presence of potentially pathogenic free-living amoebae (FLA) during flood in Chiang Mai, Thailand in 2011. From different crisis flood areas, seven water samples were collected and tested for the presence of amoebae using culture and molecular methods. By monoxenic culture, FLA were detected from all samples at 37 °C incubation. The FLA growing at 37 °C were morphologically identified as Acanthamoeba spp., Naegleria spp. and some unidentified amoebae. Only three samples (42.8%), defined as thermotolerant FLA, continued to grow at 42 °C. By molecular methods, two non-thermotolerant FlA were shown to have 99% identity to Acanthamoeba sp. and 98% identity to Hartmannella vermiformis while the two thermotolerant FLA were identified as Echinamoeba exundans (100% identity) and Hartmannella sp. (99% identity). This first report of the occurrence of FLA in water during the flood disaster will provide information to the public to be aware of potentially pathogenic FLA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 This study aimed to assess the exposure of free-living jaguars (Panthera onca) to Leptospira spp. and Brucella abortus in two conservation units in the Pantanal of Mato Grosso, Brazil. The presence of antibodies in blood samples of eleven jaguars was investigated using autochthonous antigens isolated in Brazil added to reference antigen collection applied to diagnosis of leptospirosis by Microscopic Agglutination Test (MAT). The Rose Bengal test was applied for B. abortus antibodies. Two (18.2%) jaguars were seroreactive for the Leptospira spp. antigen and the serovar considered as most infective in both animals was a Brazilian isolate of serovar Canicola (L01). All jaguars were seronegative for B. abortus. These data indicate that the inclusion of autochthonous antigens in serological studies can significantly increase the number of reactive animals, as well as modify the epidemiological profile of Leptospira spp. infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonhuman primates are considered as the natural hosts of Hepatitis A virus (HAV), as well as other pathogens, and can serve as natural sentinels to investigate epizootics and endemic diseases that are of public health importance. During this study, blood samples were collected from 112 Neotropical primates (NTPs) (Sapajus nigritus and S. cay, n = 75; Alouatta caraya, n = 37) trap-captured at the Paraná River basin, Brazil, located between the States of Paraná and Mato Grosso do Sul. Anti-HAV IgG antibodies were detected in 4.5% (5/112) of NTPs, specifically in 6.7% (5/75) of Sapajus spp. and 0% (0/37) of A. caraya. In addition, all samples were negative for the presence of IgM anti-HAV antibodies. These results suggest that free-ranging NTPs were exposed to HAV within the geographical regions evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Submitted in partial fulfillment of the requirements for the degree of Doctor of Philosophy in Electrical and Computer Engineering of the Faculdade de Ciências e Tecnologia of Universidade Nova de Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Nanotecnologias e Nanociências

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics