878 resultados para Capillary Fringe


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented in my thesis addresses the two cornerstones of modern astronomy: Observation and Instrumentation. Part I deals with the observation of two nearby active galaxies, the Seyfert 2 galaxy NGC 1433 and the Seyfert 1 galaxy NGC 1566, both at a distance of $\sim10$ Mpc, which are part of the Nuclei of Galaxies (NUGA) sample. It is well established that every galaxy harbors a super massive black hole (SMBH) at its center. Furthermore, there seems to be a fundamental correlation between the stellar bulge and SMBH masses. Simulations show that massive feedback, e.g., powerful outflows, in Quasi Stellar Objects (QSOs) has an impact on the mutual growth of bulge and SMBH. Nearby galaxies follow this relation but accrete mass at much lower rates. This gives rise to the following questions: Which mechanisms allow feeding of nearby Active Galactic Nuclei (AGN)? Is this feeding triggered by events, e.g., star formation, nuclear spirals, outflows, on $\sim500$ pc scales around the AGN? Does feedback on these scales play a role in quenching the feeding process? Does it have an effect on the star formation close to the nucleus? To answer these questions I have carried out observations with the Spectrograph for INtegral Field Observation in the Near Infrared (SINFONI) at the Very Large Telescope (VLT) situated on Cerro Paranal in Chile. I have reduced and analyzed the recorded data, which contain spatial and spectral information in the H-band ($1.45 \mic-1.85 \mic$) and K-band ($1.95 \mic-2.45 \mic$) on the central $10\arcsec\times10\arcsec$ of the observed galaxies. Additionally, Atacama Large Millimeter/Sub-millimeter Array (ALMA) data at $350$ GHz ($\sim0.87$ mm) as well as optical high resolution Hubble Space Telescope (HST) images are used for the analysis. For NGC 1433 I deduce from comparison of the distributions of gas, dust, and intensity of highly ionized emission lines that the galaxy center lies $\sim70$ pc north-northwest of the prior estimate. A velocity gradient is observed at the new center, which I interpret as a bipolar outflow, a circum nuclear disk, or a combination of both. At least one dust and gas arm leads from a $r\sim200$ pc ring towards the nucleus and might feed the SMBH. Two bright warm H$_2$ gas spots are detected that indicate hidden star formation or a spiral arm-arm interaction. From the stellar velocity dispersion (SVD) I estimate a SMBH mass of $\sim1.74\times10^7$ \msol. For NGC 1566 I observe a nuclear gas disk of $\sim150$ pc in radius with a spiral structure. I estimate the total mass of this disk to be $\sim5.4\times10^7$ \msol. What mechanisms excite the gas in the disk is not clear. Neither can the existence of outflows be proven nor is star formation detected over the whole disk. On one side of the spiral structure I detect a star forming region with an estimated star formation rate of $\sim2.6\times10^{-3}$ \msol\ yr$^{-1}$. From broad Br$\gamma$ emission and SVD I estimate a mean SMBH mass of $\sim5.3\times10^6$ \msol\ with an Eddington ratio of $\sim2\times10^{-3}$. Part II deals with the final tests of the Fringe and Flexure Tracker (FFTS) for LBT INterferometric Camera and the NIR/Visible Adaptive iNterferometer for Astronomy (LINC-NIRVANA) at the Large Binocular Telescope (LBT) in Arizona, USA, which I conducted. The FFTS is the subsystem that combines the two separate beams of the LBT and enables near-infrared interferometry with a significantly large field of view. The FFTS has a cryogenic system and an ambient temperature system which are separated by the baffle system. I redesigned this baffle to guarantee the functionality of the system after the final tests in the Cologne cryostat. The redesign did not affect any scientific performance of LINC-NIRVANA. I show in the final cooldown tests that the baffle fulfills the temperature requirement and stays $<110$ K whereas the moving stages in the ambient system stay $>273$ K, which was not given for the old baffle design. Additionally, I test the tilting flexure of the whole FFTS and show that accurate positioning of the detector and the tracking during observation can be guaranteed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La construction des biosystèmes d’oxydation passive du méthane (BOPM) est une option économique et durable pour réduire les émissions de méthane des sites d’enfouissement de déchets et des effets subséquents du réchauffement climatique. Les BOPM sont constitués de deux couches principales: la couche d'oxydation du méthane (MOL) et la couche de distribution du gaz (GDL). L'oxydation du méthane se produit dans la MOL par les réactions biochimiques des bactéries méthanotrophes, et la GDL est construite sous la MOL pour intercepter et distribuer les émissions fugitives de biogaz à la base de la MOL. Fondamentalement, l'efficacité d'un BOPM est définie en fonction de l'efficacité d'oxydation du méthane dans la MOL. Par conséquent, il est indispensable de fournir des conditions adéquates pour les activités bactériennes des méthanotrophes. En plus des paramètres environnementaux, l'intensité et la distribution du biogaz influencent l'efficacité des BOPM, et ils peuvent rendre le matériau de la MOL - avec une grande capacité d'accueillir les activités bactériennes - inutilisables en termes d'oxydation du méthane sur place. L'effet de barrière capillaire le long de l'interface entre la GDL et la MOL peut provoquer des émissions localisées de méthane, due à la restriction ou la distribution non uniforme de l’écoulement ascendant du biogaz à la base de la MOL. L'objectif principal de cette étude est d'incorporer le comportement hydraulique non saturé des BOPM dans la conception des BOPM, afin d’assurer la facilité et la distribution adéquates de l'écoulement du biogaz à la base de la MOL. Les fonctions de perméabilité à l'air des matériaux utilisés pour construire la MOL des BOPM expérimentaux au site d’enfouissement des déchets de St Nicéphore (Québec, Canada), ainsi que celles d'autres de la littérature technique, ont été étudiés pour évaluer le comportement d'écoulement non saturé du gaz dans les matériaux et pour identifier le seuil de migration sans restriction du gaz. Ce dernier seuil a été introduit en tant que un paramètre de conception avec lequel le critère de conception recommandé ici, c’est à dire la longueur de la migration sans restriction de gaz (LMSG), a été défini. La LMSG est considérée comme la longueur le long de l'interface entre la GDL et la MOL où le biogaz peut migrer à travers la MOL sans restriction. En réalisant des simulations numériques avec SEEP/W, les effets de la pente de l'interface, des paramètres définissant la courbe de rétention d'eau, de la fonction de la conductivité hydraulique du matériau de la MOL sur la valeur de la LMSG (représentant la facilité d'écoulement du biogaz à l'interface) et de la distribution de l'humidité (et par conséquent celle du biogaz) ont été évalués. Selon les résultats des simulations, la conductivité hydraulique saturée et la distribution des tailles de pores du matériau de la MOL sont les paramètres les plus importants sur la distribution de l'humidité le long de l'interface. Ce dernier paramètre influe également sur la valeur du degré de saturation et donc la facilité du biogaz à la base de la MOL. La densité sèche du matériau de MOL est un autre paramètre qui contrôle la facilité d'écoulement ascendant du biogaz. Les limitations principales de la présente étude sont associées au nombre de matériaux de MOL testés et à l'incapacité de SEEP/W de considérer l'évapotranspiration. Toutefois, compte tenu des hypothèses raisonnables dans les simulations et en utilisant les données de la littérature, on a essayé de réduire ces limitations. En utilisant les résultats des expériences et des simulations numériques, des étapes et des considérations de conception pour la sélection du matériau de MOL et de la pente d'interface ont été proposées. En effet,le comportement hydraulique non saturé des matériaux serait intégré dans les nécessités de conception pour un BOPM efficace, de sorte que la capacité maximale possible d'oxydation du méthane du matériau de la MOL soit exploitée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the wide swath of applications where multiphase fluid contact lines exist, there is still no consensus on an accurate and general simulation methodology. Most prior numerical work has imposed one of the many dynamic contact-angle theories at solid walls. Such approaches are inherently limited by the theory accuracy. In fact, when inertial effects are important, the contact angle may be history dependent and, thus, any single mathematical function is inappropriate. Given these limitations, the present work has two primary goals: 1) create a numerical framework that allows the contact angle to evolve naturally with appropriate contact-line physics and 2) develop equations and numerical methods such that contact-line simulations may be performed on coarse computational meshes.

Fluid flows affected by contact lines are dominated by capillary stresses and require accurate curvature calculations. The level set method was chosen to track the fluid interfaces because it is easy to calculate interface curvature accurately. Unfortunately, the level set reinitialization suffers from an ill-posed mathematical problem at contact lines: a ``blind spot'' exists. Standard techniques to handle this deficiency are shown to introduce parasitic velocity currents that artificially deform freely floating (non-prescribed) contact angles. As an alternative, a new relaxation equation reinitialization is proposed to remove these spurious velocity currents and its concept is further explored with level-set extension velocities.

To capture contact-line physics, two classical boundary conditions, the Navier-slip velocity boundary condition and a fixed contact angle, are implemented in direct numerical simulations (DNS). DNS are found to converge only if the slip length is well resolved by the computational mesh. Unfortunately, since the slip length is often very small compared to fluid structures, these simulations are not computationally feasible for large systems. To address the second goal, a new methodology is proposed which relies on the volumetric-filtered Navier-Stokes equations. Two unclosed terms, an average curvature and a viscous shear VS, are proposed to represent the missing microscale physics on a coarse mesh.

All of these components are then combined into a single framework and tested for a water droplet impacting a partially-wetting substrate. Very good agreement is found for the evolution of the contact diameter in time between the experimental measurements and the numerical simulation. Such comparison would not be possible with prior methods, since the Reynolds number Re and capillary number Ca are large. Furthermore, the experimentally approximated slip length ratio is well outside of the range currently achievable by DNS. This framework is a promising first step towards simulating complex physics in capillary-dominated flows at a reasonable computational expense.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, absolute water permeability is estimated from capillary imbibition and pore structure for 15 sedimentary rock types. They present a wide range of petrographic characteristics that provide degrees of connectivity, porosities, pore size distributions, water absorption coefficients by capillarity and water permeabilities. A statistical analysis shows strong correlations among the petrophysical parameters of the studied rocks. Several fundamental properties are fitted into different linear and multiple expressions where water permeability is expressed as a generalized function of the properties. Some practical aspects of these correlations are highlighted in order to use capillary imbibition tests to estimate permeability. The permeability–porosity relation is discussed in the context of the influence of pore connectivity and wettability. As a consequence, we propose a generalized model for permeability that includes information about water fluid rate (water absorption coefficient by capillarity), water properties (density and viscosity), wetting (interfacial tension and contact angle) and pore structure (pore radius and porosity). Its application is examined in terms of the type of pores that contribute to water transport and wettability. The results indicate that the threshold pore radius, in which water percolates through rock, achieves the best description of the pore system. The proposed equation is compared against Carman–Kozeny's and Katz–Thompson's equations. The proposed equation achieves very accurate predictions of the water permeability in the range of 0.01 to 1000 mD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sampling and preconcentration techniques play a critical role in headspace analysis in analytical chemistry. My dissertation presents a novel sampling design, capillary microextraction of volatiles (CMV), that improves the preconcentration of volatiles and semivolatiles in a headspace with high throughput, near quantitative analysis, high recovery and unambiguous identification of compounds when coupled to mass spectrometry. The CMV devices use sol-gel polydimethylsiloxane (PDMS) coated microglass fibers as the sampling/preconcentration sorbent when these fibers are stacked into open-ended capillary tubes. The design allows for dynamic headspace sampling by connecting the device to a hand-held vacuum pump. The inexpensive device can be fitted into a thermal desorption probe for thermal desorption of the extracted volatile compounds into a gas chromatography-mass spectrometer (GC-MS). The performance of the CMV devices was compared with two other existing preconcentration techniques, solid phase microextraction (SPME) and planar solid phase microextraction (PSPME). Compared to SPME fibers, the CMV devices have an improved surface area and phase volume of 5000 times and 80 times, respectively. One (1) minute dynamic CMV air sampling resulted in similar performance as a 30 min static extraction using a SPME fiber. The PSPME devices have been fashioned to easily interface with ion mobility spectrometers (IMS) for explosives or drugs detection. The CMV devices are shown to offer dynamic sampling and can now be coupled to COTS GC-MS instruments. Several compound classes representing explosives have been analyzed with minimum breakthrough even after a 60 min. sampling time. The extracted volatile compounds were retained in the CMV devices when preserved in aluminum foils after sampling. Finally, the CMV sampling device were used for several different headspace profiling applications which involved sampling a shipping facility, six illicit drugs, seven military explosives and eighteen different bacteria strains. Successful detection of the target analytes at ng levels of the target signature volatile compounds in these applications suggests that the CMV devices can provide high throughput qualitative and quantitative analysis with high recovery and unambiguous identification of analytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We find ourselves, after the close of the twentieth century, looking back at a mass of responses to the knowledge organization problem. Many institutions, such as the Dewey Decimal Classification (Furner, 2007), have grown up to address it. Increasingly, many diverse discourses are appropriating the problem and crafting a wide variety of responses. This includes many artistic interpretations of the act and products of knowledge organization. These surface as responses to the expressive power or limits of the Library and Information Studies institutions (e.g., DDC) and their often primarily utilitarian gaze.One way to make sense of this diversity is to approach the study from a descriptive stance, inventorying the population of types of KOS. This population perspective approaches the phenomenon of types and boundaries of Knowledge Organization Systems (KOS) as one that develops out of particular discourses, for particular purposes. For example, both DDC and Martianus Capella, a 5th Century encyclopedist, are KOS in this worldview. Both are part of the population of KOS. Approaching the study of KOS from the population perspective allows the researcher a systematic look at the diversity emergent at the constellation of different factors of design and implementation. However, it is not enough to render a model of core types, but we have to also consider the borders of KOS. Fringe types of KOS inform research, specifically to the basic principles of design and implementation used by others outside of the scholarly and professional discourse of Library and Information Studies.Four examples of fringe types of KOS are presented in this paper. Applying a rubric developed in previous papers, our aim here is to show how the conceptual anatomy of these fringe types relates to more established KOS, thereby laying bare the definitions of domain, purpose, structure, and practice. Fringe types, like Beghtol’s examples (2003), are drawn from areas outside of Library and Information Studies proper, and reflect the reinvention of structures to fit particular purposes in particular domains. The four fringe types discussed in this paper are (1) Roland Barthes’ text S/Z which “indexes” a text of an essay with particular “codes” that are meant to expose the literary rhythm of the work; (2) Mary Daly’s Wickedary, a reference work crafted for radical liberation theology – and specifically designed to remove patriarchy from the language used by what the author calls “wild women”; (3) Luigi Serafini’s Codex Seraphinianus a work of book art that plays on the trope of universal encyclopedia and back-of- the book index; and (4) Martinaus Capella – and his Marriage of Mercury and Philology, a fifth century encyclopedia. We compared these using previous analytic taxonomies (Wright, 2008; Tennis, 2006; Tudhope, 2006, Soergel, 2001, Hodge, 2000).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the use of intravascular optical coherence tomography (IVOCT) for carotid artery stenting (CAS) procedures in patients with atherosclerotic stenosis. Examine possible markers that might identify the onset of new cerebral ischemic lesions on MRI. Specifically, attention was drawn to the morphological features of the used dual layer stent, which could be underestimated during traditional CAS procedures. Secondary goals are to compare the safety and efficacy of different CAS techniques and the accuracy of the vessel analysis software’s on pre-operative CTA examination used to quantify ICA stenosis with the gold standard IVOCT. Material and Methods: Ten patients underwent CAS procedure with flow-arrest technique and IVOCT evaluations prior to and following stent deployment, while five matched patients underwent CAS procedure with distal embolic protection device (EPD) technique. All patients underwent 24-hours 3T MRI examination to check for ischemic lesions; all patients were treated with the same dual-layer stent. Results: Patients with new ischemic lesions demonstrated peculiar stent configuration in the distal end, and a strong Spearman’s rank order correlation was found among the volume of new DWI lesions and the stent configuration in its distal end (Rs: 0.81; p <0.001). No statistically significant differences were observed in the total burden of new ischemic lesions for each technique. The vessel analysis software's on CTA comparison demonstrated a higher diagnostic accuracy in the degree of ICA stenosis compared to the gold standard of IVOCT of the specialized software (ROC curve = 0.63; p = 0.06) compared to the general software (ROC curve = 0.57, p = 0.31). Conclusions: Study’s results support the use of IVOCT to allow recognition of potential features that can predict the onset of new cerebral ischemic lesions. Additionally, IVOCT made it possible to evaluate specialized software's increased accuracy in the pre-operative evaluation of ICA atherosclerotic stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydroxyurea (HU), or hydroxycarbamide, is used for the treatment of some myeloproliferative and neoplastic diseases, and is currently the only drug approved by the FDA for use in sickle cell disease (SCD). Despite the relative success of HU therapy for SCD, a genetic disorder of the hemoglobin β chain that results in red-cell sickling, hemolysis, vascular inflammation and recurrent vasoocclusion, the exact mechanisms by which HU actuates remain unclear. We hypothesized that HU may modulate endothelial angiogenic processes, with important consequences for vascular inflammation. The effects of HU (50-200 μM; 17-24 h) on endothelial cell functions associated with key steps of angiogenesis were evaluated using human umbilical vein endothelial cell (HUVEC) cultures. Expression profiles of the HIF1A gene and the miRNAs 221 and 222, involved in endothelial function, were also determined in HUVECs following HU administration and the direct in vivo antiangiogenic effects of HU were assessed using a mouse Matrigel-plug neovascularization assay. Following incubation with HU, HUVECs exhibited high cell viability, but displayed a significant 75% inhibition in the rate of capillary-like-structure formation, and significant decreases in proliferative and invasive capacities. Furthermore, HU significantly decreased HIF1A expression, and induced the expression of miRNA 221, while downregulating miRNA 222. In vivo, HU reduced vascular endothelial growth factor (VEGF)-induced vascular development in Matrigel implants over 7 days. Findings indicate that HU is able to inhibit vessel assembly, a crucial angiogenic process, both in vitro and in vivo, and suggest that some of HU's therapeutic effects may occur through novel vascular mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As hypoxia-induced inflammatory angiogenesis may contribute to sickle cell disease manifestations, we compared the angiogenic molecular profiles of plasma from sickle cell disease individuals and correlated these with in vitro endothelial cell-mediated angiogenesis-stimulating activity and in vivo neovascularization. Bioplex demonstrated that plasma from steady-state sickle cell anemia patients presented elevated concentrations of pro-angiogenic factors (Angiopoietin-1, basic fibroblast growth factor, vascular endothelial growth factor, vascular endothelial growth factor-D and placental growth factor) and displayed potent pro-angiogenic activity, significantly augmenting endothelial cell proliferation, migration and capillary-like structure formation. In vivo neovascularization of Matrigel plugs was significantly greater in sickle cell disease mice, compared with non-sickle cell disease mice, consistent with an upregulation of angiogenesis in the disease. In plasma from patients with hemoglobin SC disease without proliferative retinopathy, anti-angiogenic endostatin and thrombospondin-2 were significantly elevated. In contrast, plasma from hemoglobin SC individuals with proliferative retinopathy displayed a pro-angiogenic profile and had more significant effects on endothelial cell proliferation and capillary formation than plasma of patients without retinopathy. Hydroxyurea therapy was associated with significant reductions in plasma angiogenic factor profile, in association with an inhibition of endothelial cell-mediated angiogenic mechanisms and neovascularization. Thus, sickle cell anemia and retinopathic hemoglobin SC individuals present a highly angiogenic circulating milieu, capable of stimulating key endothelial cell-mediated angiogenic mechanisms. Combination anti-angiogenic therapy for preventing progression of unregulated neovascularization and associated manifestations in sickle cell disease, such as pulmonary hypertension, may be indicated; furthermore, the benefits and drawbacks of the potent anti-angiogenic effects of hydroxyurea should be clarified.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monolithic stationary phases represent a new generation of chromatographic separation media. These phases consist of a continuous separation bed prepared by in situ polymerization or consolidation inside the column tubing. In recent years, their simple preparation procedure, unique properties and excellent performance have attracted quite remarkable attention in liquid chromatography and capillary electrochromatography. This review summarizes the preparation, characterization and applications of monolithic stationary phases. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different separation modes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a contribution that presents a translation of the work Terminology for Analytical Capillary Electromigration Techniques by Riekkola and collaborators (Pure Appl. Chem., Vol. 76, No. 2, 443-451, 2004) from IUPAC© for the Portuguese Language. Additional terms that had not been defined in native Portuguese were included for the benefit of the local community. Additional notes were also included to clarify some important concepts and to highlight the differences between techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review describes the advantages and disadvantages of using capillary liquid chromatography (CLC), which is considered the newest member in the analytical separation science arsenal. Although CLC has tremendous potential for being the next major innovation in separatory analysis, it has not yet obtained great popularity compared to conventional high performance (and ultra-high performance) liquid chromatography. Comparisons are made between these techniques and some of the reasons that CLC has not yet reached its potential will be advanced.