918 resultados para CHRONIC ATRIAL FIBRILLATION
Resumo:
BACKGROUND Long-term success rates using ablation for persistent atrial fibrillation (AF) are disappointing and usually do not exceed 60%. OBJECTIVES This study sought to compare arrhythmia-free survival between pulmonary vein isolation (PVI) and a stepwise approach (full defrag) consisting of PVI, ablation of complex fractionated electrograms, and additional linear ablation lines in the setting of atrial tachycardias (AT) in patients with persistent AF after PVI. METHODS From November 2010 to February 2013, 205 patients (151 men; 61.7 ± 10.2 years of age) underwent de novo ablation for persistent AF. Subsequently, patients were prospectively randomized to either PVI alone (n = 78) or full defrag (n = 75), with 52 patients not randomized due to AF termination with the original PVI. The primary endpoint was recurrence of any AT after a blanking period of 3 months. RESULTS During the entire study, 241 ablations were performed (mean: 1.59 in the PVI-alone group, 1.55 in the full-defrag group). With the stepwise approach, termination of AF occurred in 45 (60%) patients. However, arrhythmia-free survival did not differ whether patients underwent single or multiple procedures (p = 0.468). Procedure duration, fluoroscopy time, and radiofrequency duration were significantly longer in the full-defrag group (all p < 0.001). CONCLUSIONS A stepwise approach aimed at AF termination does not seem to provide additional benefit over PVI alone in patients with persistent AF, but it is associated with significantly longer procedural and fluoroscopic duration as well as radiofrequency application time. (The Randomized Catheter Ablation of Persist End Atrial Fibrillation Study [CHASE-AF]; NCT01580124).
Resumo:
OBJECTIVES: Extensive endurance training and arterial hypertension are established risk factors for atrial fibrillation. We aimed to assess the proportion of masked hypertension in endurance athletes and the impact on cardiac remodeling, mechanics, and supraventricular tachycardias (SVT). METHODS: Male participants of a 10-mile race were recruited and included if office blood pressure was normal (<140/90 mmHg). Athletes were stratified into a masked hypertension and normotension group by ambulatory blood pressure. Primary endpoint was diastolic function, expressed as peak early diastolic mitral annulus velocity (E'). Left ventricular global strain, left ventricular mass/volume ratio, left atrial volume index, signal-averaged P-wave duration (SAPWD), and SVT during 24-h Holter monitoring were recorded. RESULTS: From 108 runners recruited, 87 were included in the final analysis. Thirty-three (38%) had masked hypertension. The mean age was 42 +/- 8 years. Groups did not differ with respect to age, body composition, cumulative training hours, and 10-mile race time. Athletes with masked hypertension had a lower E' and a higher left ventricular mass/volume ratio. Left ventricular global strain, left atrial volume index, SAPWD, and SVT showed no significant differences between the groups. In multiple linear regression analysis, masked hypertension was independently associated with E' (beta = -0.270, P = 0.004) and left ventricular mass/volume ratio (beta = 0.206, P = 0.049). Cumulative training hours was the only independent predictor for left atrial volume index (beta = 0.474, P < 0.001) and SAPWD (beta = 0.481, P < 0.001). CONCLUSION: In our study, a relevant proportion of middle-aged athletes had masked hypertension, associated with a lower diastolic function and a higher left ventricular mass/volume ratio, but unrelated to left ventricular systolic function, atrial remodeling, or SVT.
Resumo:
OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).
Resumo:
We read with great interest the large-scale network meta-analysis by Kowalewski et al. comparing clinical outcomes of patients undergoing coronary artery bypass grafting (CABG) operated on using minimal invasive extracorporeal circulation (MiECC) or off-pump (OPCAB) with those undergoing surgery on conventional cardiopulmonary bypass (CPB) [1]. The authors actually integrated into single study two recently published meta-analysis comparing MiECC and OPCAB with conventional CPB, respectively [2, 3] into a single study. According to the results of this study, MiECC and OPCAB are both strongly associated with improved perioperative outcomes following CABG when compared with CABG performed on conventional CPB. The authors conclude that MiECC may represent an attractive compromise between OPCAB and conventional CPB. After carefully reading the whole manuscript, it becomes evident that the role of MiECC is clearly undervalued. Detailed statistical analysis using the surface under the cumulative ranking probabilities indicated that MiECC represented the safer and more effective intervention regarding all-cause mortality and protection from myocardial infarction, cerebral stroke, postoperative atrial fibrillation and renal dysfunction when compared with OPCAB. Even though no significant statistical differences were demonstrated between MiECC and OPCAB, the superiority of MiECC is obvious by the hierarchy of treatments in the probability analysis, which ranked MiECC as the first treatment followed by OPCAB and conventional CPB. Thus, MiECC does not represent a compromise between OPCAB and conventional CPB, but an attractive dominant technique in CABG surgery. These results are consistent with the largest published meta-analysis by Anastasiadis et al. comparing MiECC versus conventional CPB including a total of 2770 patients. A significant decrease in mortality was observed when MiECC was used, which was also associated with reduced risk of postoperative myocardial infarction and neurological events [4]. Similarly, another recent meta-analysis by Benedetto et al. compared MiECC versus OPCAB and resulted in comparable outcomes between these two surgical techniques [5]. As stated in the text, superiority of MiECC observed in the current network meta-analysis, when compared with OPCAB, could be attributed to the fact that MiECC offers the potential for complete revascularization, whereas OPCAB poses a challenge for unexperienced surgeons; especially when distal marginal branches on the lateral and/or posterior wall of the heart need revascularization. This is reflected by a significantly lower number of distal anastomoses performed in OPCAB when compared with conventional CPB. Therefore, taking into consideration the literature published up to date, including the results of the current article, we advocate that MiECC should be integrated in the clinical practice guidelines as a state-of-the-art technique and become a standard practice for perfusion in coronary revascularization surgery.
Resumo:
The clinical and demographic characteristics of patients undergoing TAVI pose unique challenges for developing and implementing optimal antithrombotic therapy. Ischaemic and bleeding events in the periprocedural period and months after TAVI still remain a relevant concern to be faced with optimised antithrombotic therapy. Moreover, the antiplatelet and anticoagulant pharmacopeia has evolved significantly in recent years with new drugs and multiple possible combinations. Dual antiplatelet therapy (DAPT) is currently recommended after TAVI with oral anticoagulation (OAC) restricted for specific indications. However, atrial fibrillation (which is often clinically silent and unrecognised) is common after the procedure and embolic material often thrombin-rich. Recent evidence has therefore questioned this approach, suggesting that DAPT may be futile compared with aspirin alone and that OAC could be a relevant alternative. Future randomised and appropriately powered trials comparing different regimens of antithrombotic therapy, including new antiplatelet and anticoagulant agents, are warranted to increase the available evidence on this topic and create appropriate recommendations for this frail population. Meanwhile, it remains rational to adhere to current guidelines, with routine DAPT and recourse to OAC when specifically indicated, whilst always tailoring therapy on the basis of individual bleeding and thromboembolic risk.
Resumo:
The purpose of this study was to elucidate the relationship between mitral valve prolapse and stroke. A population-based historical cohort investigation was conducted among residents of Olmsted County, Minnesota who had an initial echocardiographic diagnosis of mitral valve prolapse from 1975 through 1989. This cohort (N = 1085) was followed for stroke outcomes using the resources of an operational medical record linkage system. There was an overall two-fold increase in the incidence of stroke among individuals with mitral valve prolapse relative to a standard population (standardized morbidity ratio = 2.12, 95% confidence limits = 1.33-3.21). When the data were partitioned by duration of follow-up from the diagnosis of mitral valve prolapse, or by the calendar years at echocardiographic diagnosis, respectively, the association between mitral valve prolapse and stroke was not modified. Mitral valve prolapse subjects 85 years and older were at highest increased risk of developing strokes relative to the general population (standardized morbidity ratio = 5.47, 95% confidence limits = 2.20-11.24). Coronary heart disease, atrial fibrillation, diabetes mellitus and hypertension, were unlikely to have confounded the association between mitral valve prolapse and stroke.^ The cumulative risk of first stroke among individuals initially diagnosed with mitral valve prolapse age 15 to 64 years, given survival to 15.2 years of follow-up, was 4.0%. The cumulative risk of first stroke among individuals initially diagnosed with mitral valve prolapse age 65 to 74 years, given survival to 11.2 years of follow-up, was 13.2%. The cumulative risk of first stroke among individuals initially diagnosed with mitral valve prolapse age 75 years and older, given survival to 6.7 years of follow-up, was 30.6%.^ Among individuals with mitral valve prolapse, age, diabetes, and atrial fibrillation were associated with an increased risk of stroke. Atrial fibrillation was associated with a four-fold rate of stroke and diabetes associated with a seven-fold rate of stroke.^ Findings from this research support the hypothesis that mitral valvular heart prolapse is linked with a stroke sequela. ^
Resumo:
La fibrilación auricular es la taquiarritmia más frecuente en la población general. La frecuencia de dicha arritmia aumenta con la edad, presentándose en un 1.5% de los 50 a 59 años a 8-10% de los 80 a 89 años. La fibrilación auricular incrementa el riesgo de sufrir un evento cerebrovascular isquémico cardioembólico en 5 veces y causa el 15% de todos los accidentes cerebrovasculares isquémicos. El manejo de la fibrilación auricular se enfoca, principalmente, en la prevención de los fenómenos tromboembólicos y en el control de la frecuencia y ritmo cardiaco. La anticoagulación, ha demostrado ser la principal herramienta en la prevención de eventos cardioembólicos. Aunque las complicaciones hemorrágicas por el tratamiento son esperables, y aumentan con la edad, sobrepasa por mucho, el beneficio de usar anticoagulación, al riesgo de sangrados. Precisamente debido a la heterogeneidad clínica de esta arritmia y a la dificultad de establecer un tratamiento adecuado para cada caso en particular, el American College of Cardiology, la American Heart Association, la European Society of Cardiology y el American College of Chest Physicians han establecido unas guías para mejorar el manejo de los pacientes. La revisión de esta patología y de estas directrices propuestas pueden facilitar y mejorar notablemente el tratamiento de los pacientes con fibrilación auricular.
Resumo:
In this paper, a new method is presented to ensure automatic synchronization of intracardiac ECG data, yielding a three-stage algorithm. We first compute a robust estimate of the derivative of the data to remove low-frequency perturbations. Then we provide a grouped-sparse representation of the data, by means of the Group LASSO, to ensure that all the electrical spikes are simultaneously detected. Finally, a post-processing step, based on a variance analysis, is performed to discard false alarms. Preliminary results on real data for sinus rhythm and atrial fibrillation show the potential of this approach.
Resumo:
La Ingeniería Biomédica surgió en la década de 1950 como una fascinante mezcla interdisciplinaria, en la cual la ingeniería, la biología y la medicina aunaban esfuerzos para analizar y comprender distintas enfermedades. Las señales existentes en este área deben ser analizadas e interpretadas, más allá de las capacidades limitadas de la simple vista y la experiencia humana. Aquí es donde el procesamiento digital de la señal se postula como una herramienta indispensable para extraer la información relevante oculta en dichas señales. La electrocardiografía fue una de las primeras áreas en las que se aplicó el procesado digital de señales hace más de 50 años. Las señales electrocardiográficas continúan siendo, a día de hoy, objeto de estudio por parte de cardiólogos e ingenieros. En esta área, las técnicas de procesamiento de señal han ayudado a encontrar información oculta a simple vista que ha cambiado la forma de tratar ciertas enfermedades que fueron ya diagnosticadas previamente. Desde entonces, se han desarrollado numerosas técnicas de procesado de señales electrocardiográficas, pudiéndose resumir estas en tres grandes categorías: análisis tiempo-frecuencia, análisis de organización espacio-temporal y separación de la actividad atrial del ruido y las interferencias. Este proyecto se enmarca dentro de la primera categoría, análisis tiempo-frecuencia, y en concreto dentro de lo que se conoce como análisis de frecuencia dominante, la cual se va a aplicar al análisis de señales de fibrilación auricular. El proyecto incluye una parte teórica de análisis y desarrollo de algoritmos de procesado de señal, y una parte práctica, de programación y simulación con Matlab. Matlab es una de las herramientas fundamentales para el procesamiento digital de señales por ordenador, la cual presenta importantes funciones y utilidades para el desarrollo de proyectos en este campo. Por ello, se ha elegido dicho software como herramienta para la implementación del proyecto. ABSTRACT. Biomedical Engineering emerged in the 1950s as a fascinating interdisciplinary blend, in which engineering, biology and medicine pooled efforts to analyze and understand different diseases. Existing signals in this area should be analyzed and interpreted, beyond the limited capabilities of the naked eye and the human experience. This is where the digital signal processing is postulated as an indispensable tool to extract the relevant information hidden in these signals. Electrocardiography was one of the first areas where digital signal processing was applied over 50 years ago. Electrocardiographic signals remain, even today, the subject of close study by cardiologists and engineers. In this area, signal processing techniques have helped to find hidden information that has changed the way of treating certain diseases that were already previously diagnosed. Since then, numerous techniques have been developed for processing electrocardiographic signals. These methods can be summarized into three categories: time-frequency analysis, analysis of spatio-temporal organization and separation of atrial activity from noise and interferences. This project belongs to the first category, time-frequency analysis, and specifically to what is known as dominant frequency analysis, which is one of the fundamental tools applied in the analysis of atrial fibrillation signals. The project includes a theoretical part, related to the analysis and development of signal processing algorithms, and a practical part, related to programming and simulation using Matlab. Matlab is one of the fundamental tools for digital signal processing, presenting significant functions and advantages for the development of projects in this field. Therefore, we have chosen this software as a tool for project implementation.
Resumo:
Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014
Resumo:
- Réalisé au centre de recherche de l'hospital du Sacré-Coeur de Montréal. - Programme conjoint entre Université de Montréal et École Polytechnique de Montréal.
Resumo:
BACKGROUND: Despite stroke's high prevalence in the elderly, intravenous thrombolysis is licensed in Europe only for patients younger than 80 years old. We aimed to compare the functional outcomes and complication rates in patients older versus younger than 80 years old treated with intravenous thrombolysis. METHODS: A retrospective observational study of patients who received intravenous thrombolysis in a stroke unit between January 1, 2009, and June 30, 2012, was conducted. Variables were compared between 2 subgroups (≤80 and >80 years). RESULTS: Overall, 512 patients underwent intravenous thrombolysis, of which 13.1% were over 80 years. The mean age was 65.4 years in the younger subgroup and 82.9 years in the older subgroup. Prior independence rates did not differ between the subgroups. Prevalence of atrial fibrillation and cardioembolic stroke was higher in the older subgroup (P = .004 and .026). Only 3% of the elderly with atrial fibrillation were taking oral anticoagulants. Symptoms-to-needle time was lower in the older subgroup (P = .048). Stroke severity was higher in patients over 80 years (P = .026). There was significant improvement in the National Institutes of Health Stroke Scale score 7 days after intravenous thrombolysis (P < .001) in both subgroups. The proportion of patients with 3 months' favorable outcome and independence, hemorrhagic transformation, and mortality rates were similar in both subgroups. CONCLUSIONS: Elderly patients' benefits and outcomes from intravenous thrombolysis treatment were identical to the younger subgroup without excess hemorrhagic transformation or mortality. These results favor the use of intravenous thrombolysis in patients over 80 years.
Resumo:
AIMS Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologist's supervision. METHODS AND RESULTS Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.
Resumo:
Permanent destruction of abnormal cardiac tissue responsible for cardiac arrhythmogenesis whilst avoiding collateral tissue injury forms the cornerstone of catheter ablation therapy. As the acceptance and performance of catheter ablation increases worldwide, limitations in current technology are becoming increasingly apparent in the treatment of complex arrhythmias such as atrial fibrillation. This review will discuss the role of new technologies aimed to improve lesion formation with the ultimate goal of improving arrhythmia-free survival of patients undergoing catheter ablation of atrial arrhythmias.
Resumo:
Objective: To evaluate contractile reserve (CR) determined by exercise echocardiography in predicting clinical outcome and left ventricular (LV) function in asymptomatic severe mitral regurgitation (MR). Design: Cohort study. Setting: Regional cardiac centre. Patients and outcome measures: LV volumes and ejection fraction (EF) were measured at rest and after stress in 71 patients with isolated MR. During follow up (mean (SD) 3 (1) years), EF and functional capacity were serially assessed and cardiac events ( cardiac death, heart failure, and new atrial fibrillation) were documented. Results: CR was present in 45 patients (CR+) and absent in 26 patients (CR-). Age, resting LV dimensions, EF, and MR severity were similar in both groups. Mitral surgery was performed in 19 of 45 (42%) CR+ patients and 22 of 26 (85%) CR2 patients. In patients undergoing surgery, CR was an independent predictor of follow up EF (p = 0.006) and postoperative LV dysfunction (EF < 50%) persisted in five patients, all in the CR2 group. Event-free survival was lower in surgically treated patients without CR (p = 0.03). In medically treated patients, follow up EF was preserved in those with intact CR but progressively deteriorated in patients without CR, in whom functional capacity also deteriorated. Conclusions: Evaluation of CR by exercise echocardiography may be useful for risk stratification and may help to optimise the timing of surgery in asymptomatic severe MR.