945 resultados para Apulian platform
Resumo:
The report is a summary based on information received by ECLAC from the eight English-speaking Caribbean countries of Barbados, Belize, the Cayman Islands, the Commonwealth of Dominica, Jamaica, Suriname, Saint Vincent and the Grenadines and Trinidad and Tobago in response to the questionnaire to governments on the Implementation of the Beijing Declaration and Platform for Action (1995) and the Outcome of the Twenty-Third Special Session of the General Assembly (2000). The report is therefore set in the context of the regional review and appraisals of the fifteenth anniversary of the adoption of the Beijing Declaration and Platform for Action in 2010. This Executive Summary highlights the achievements and the challenges for the Caribbean subregion in the progress towards implementation of the Beijing Platform of Action.
Resumo:
The Caribbean sub-regional synthesis report, covering 12 countries, assesses progress towards the gender equality goals articulated in the 1995 World Conference on Women, which produced the Beijing Platform for Action (BPfA). The process leading to the preparation of the report has involved a series of national, regional and global consultations that will culminate in the Beijing + 20 Review. The process has also led to the formulation of the Caribbean Joint Statement on Gender Equality and the Post-2015, as well as the SIDS Agenda, both of which express Caribbean perspectives and expectations regarding gender equality.
Resumo:
Após a glaciação do final do Criogeniano, a região central do Brasil foi palco de extensa deposição de carbonatos plataformais do Grupo Araras. Este grupo inclui na sua base uma seqüência de capa carbonática sucedida por depósitos transgressivos de calcilutitos betuminosos e folhelhos de plataforma profunda. Dados de fácies e estratigráficos combinados com análises isotópicas de carbono e oxigênio da seção mais completa desses depósitos transgressivos, expostos no sinclinal da Guia, foram empregados para avaliar o paleambiente deposicional e para testar a correlação desses depósitos ao longo da faixa e também com outras unidades de outros continentes. A sucessão estudada consiste de 150 m de espessura de camadas tabulares de calcilutitos e folhelhos cinza a pretos com valores de d13CPDB negativos, entre -2,5 e -1 . O perfil de d13CPDB do sinclinal da Guia mostra clara correlação com a porção superior da Formação Guia da região de Cáceres, 200 km a sudoeste. O perfil de d13CPDB do Grupo Araras é comparável aos perfis de d13CPDB de outras unidades ediacaranas da parte sul da Faixa Paraguai, oeste do Canadá, e crátons do Congo e do Kalahari. Além disso, a distribuição de fácies, estratigrafia e o perfil isotópico do Grupo Araras são equiparáveis à porção média do Subgrupo Tsumeb na Namíbia, o que reforça a atribuição de idade Ediacarana para o Grupo Araras.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
The aim of this study was to evaluate stress distribution on the pen-implant bone, simulating the influence of Nobel Select implants with straight or angulated abutments on regular and switching platform in the anterior maxilla, by means of 3-dimensional finite element analysis. Four mathematical models of a central incisor supported by external hexagon implant (13 mm x 5 mm) were created varying the platform (R, regular or S. switching) and the abutments (S, straight or A, angulated 15 degrees). The models were created by using Mimics 13 and Solid Works 2010 software programs. The numerical analysis was performed using ANSYS Workbench 10.0. Oblique forces (100 N) were applied to the palatine surface of the central incisor. The bone/implant interface was considered perfectly integrated. Maximum (sigma(max)) and minimum (sigma(min)) principal stress values were obtained. For the cortical bone the highest stress values (sigma(max)) were observed in the RA (regular platform and angulated abutment, 51 MPa), followed by SA (platform switching and angulated abutment, 44.8 MPa), RS (regular platform and straight abutment, 38.6 MPa) and SS (platform switching and straight abutment, 36.5 MPa). For the trabecular bone, the highest stress values (sigma(max)) were observed in the RA (6.55 MPa), followed by RS (5.88 MPa), SA (5.60 MPa), and SS (4.82 MPa). The regular platform generated higher stress in the cervical periimplant region on the cortical and trabecular bone than the platform switching, irrespective of the abutment used (straight or angulated).
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.
Resumo:
The concept of switching platform is the use of an implant by platform wider than the abutment. Recently, researches have shown that this type of dental implant design tends to offer a higher preservation of crestal bone when compared to the traditional pattern of bone loss. The present study aims to perform a critical review on the switching platform concept establishing possible advantages of the technique. A search was performed on Medline/Pubmed about the topic “dental implant” and “platform switching”, and after applying inclusion criteria 40 studies were selected. The literature on longevity present prospective studies that show less bone loss, studies in biomechanics exhibit better or similar stress distribution around the bone crest, however, is not yet defined the role of the biological width. Thus, studies of longevity, and randomized prospective studies are of a great relevance to be performed in order to confirm the benefits of this technique and to establish a protocol indication. It is possible, based on this literature review, to conclude that longitudinal and randomized studies show that the platform switching implants have longevity and less bone loss. Biomechanically, the technique is possible.